IMPORTANT:
Installer: Leave lnstallalion Instructions with the homeowner. Homeowner: Keep Installation Instructions for future reference. Save Installation Instructions for local electrical inspector’s use.
I,
.\
Part No. 3181199
For new Installations:
‘Note: 24” min. vhn
I
11111
Before you start...
Proper installation is your responsibility. Make sure you have everyihing necessary
lor correct installation. II is Ihe responsibility 01 the installer lo comply wiih Ihe installation clearance specilied on Ihe serial/rating plate. The serialfraling plate is located on the bolrom ol (he cooktop.
Check locatlon where cooktop will be inslalled. The location should be away lrom strong dratt areas, such as windows, doors
and slrong heating vents or tans. The cooklop should be located for convenienl use in the kitchen.
ALL OPENINGS IN THE WALL OR FLOOR
WHERE COOKTOP IS TO BE INSTALLED
MUST BE SEALED.
Grounded electrlcal outlet is required.
See Electrical requirements.
Counterlop openlng dlmenslons thal are
shown musl be used. Given dimensions are
minimum clearances and provide required
0” clearance.
NOTE: Clearances specilied are for
combustzble walls and materials that have a
densitv of 20 or more oounds oer cubic 1001.
No evaluation 01 clearances his been made lor installalions adjacent lo malerials lhal
are less lhan 20 pounds per cu. Ii. or lo
plastic liles and sheetmg. New lnslallallons - Follow minimum
dimensions given.
Replacement lnslallalions - Be sure lhal lront edge 01 cooklop is at least l-112” back horn Iron! edge of counleriop.
IMPORTANT: Observe all governing codes and ordinances. Failure to meet codes and ordinances could lead lo fire or
eleclrlcal shock.
30” min. base cabinet Is required. II cabinet has a drawer, a 3’deplh clearance Irom lhe counlerlop lo Ihe top of the drawer (or other
obslruclion) in base cabinet is required.
ElectrIcal Shock Hazard It IS the cuslomer’s responslblllly: . To contact a qualllled eleclrlcal Installer. . To assure that the elecLrlcal lnslallatlon
Is adequate and In conlormance wllh Nallonal Elecirlcal Code, ANSUNFPA 70-latest edlllon”, and all local codes and ordinances.
Failure lo do so could result In eleclrlcal shock or other personal Injury.
Cabinet storage above Ihe cooklng surface
should be avolded. If cablnels are already Insialled, reduce the hazard of reaching over a heated cooking surlace by Installing a range hood.
The range hood should exlend a minlmum of 5 Inches out trom the bottom from 01 the cabinels.
Reaching over a heated cooking surlace could result In a serious burn.
Copies of the slandards listed may be obtained from:
‘* Nallonal Fire Prolecllon As~oclallon
Personal Injury Hazard
Banerymarch Park Qulncy, Massachusetts 02269