INSTALLATION INSTRUCTIONS
IMPORTANT:
Save for local electrical inspector's use.
IMPORTANT :
À conserver pour consultation par l'inspecteur local des installations électriques.
24" (61 CM), 27" (68.6 CM), AND 30" (76.2 CM)
INDOOR/OUTDOOR ELECTRIC WARMING DRAWER
INSTRUCTIONS D'INSTALLATION
TIROIR-RÉCHAUD ÉLECTRIQUE POUR USAGE
INTÉRIEUR/EXTÉRIEUR DE 24" (61 CM),
27" (68,6 CM), ET 30" (76,2 CM)
Table of Contents/Table des matières
WARMING DRAWER SAFETY ......................................................2
INSTALLATION REQUIREMENTS................................................3
Tools and Parts ............................................................................3
Location Requirements................................................................3
Electrical Requirements ...............................................................6
INSTALLATION INSTRUCTIONS..................................................6
Install Warming Drawer................................................................6
Complete Installation ...................................................................7
CUSTOM DRAWER FRONT INSTALLATION
INSTRUCTIONS FOR WARMING DRAWERS..............................7
Tools and Parts ............................................................................7
Install Custom Drawer Front Panel ..............................................7
SÉCURITÉ DU TIROIR-RÉCHAUD ...............................................9
EXIGENCES D’INSTALLATION...................................................10
Outillage et pièces......................................................................10
Exigences d’emplacement.........................................................10
Spécifications électriques ..........................................................13
INSTRUCTIONS D'INSTALLATION.............................................13
Installation du tiroir-réchaud ......................................................13
Achever l'installation ..................................................................14
INSTRUCTIONS D'INSTALLATION DE LA FAÇADE
DU TIROIR PERSONNALISÉ POUR TIROIR-RÉCHAUD..........14
Outillage et pièces......................................................................14
Installation du panneau de la façade du tiroir personnalisé......14
WARMING DRAWER SAFETY
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
2
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools Needed
■ Phillips screwdriver
■ Flat-blade screwdriver
■ Measuring tape
■ Level
■ Drill
■ 1³⁄₈" (3.5 cm) hole saw
Parts Supplied
■ Two #8–18 x ¹⁄₂" screws
■ Lens (for panel ready models)
Check local codes. Check existing electrical supply. See
“Electrical Requirements.”
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
■ Cutout dimensions that are shown must be used. Given
dimensions provide minimum clearance with warming drawer.
■ Recessed installation area must provide complete enclosure
around the recessed portion of the warming drawer.
■ Grounded electrical supply is required. See “Electrical
Requirements” section.
■ Electrical supply outlet should be located in the rear wall on
the upper right-hand side of the cutout or in an adjacent
cabinet. The outlet must be recessed. If the electrical outlet is
located in an adjacent cabinet, a 1³⁄₈" (3.5 cm) minimum
diameter hole should have been drilled in the back of the
cutout or support surface to pass the power supply cord
through to the outlet.
■ Warming drawer support surface must be solid, level and flush
with bottom of cabinet cutout.
■ Warming drawers with oiled bronze, black glass, and white
glass panels are approved for indoor use only.
■ Support surface must be solid, level, and flush with the
bottom of the cabinet cutout.
■ 24" (61 cm) minimum cabinet depth.
For best performance results make sure the warming drawer is
leveled before completing installation. There is no way to level the
warming drawer after it has been installed. If the installation is not
level, the door may slide open or not seal tightly, allowing heat to
escape.
NOTE: If installing the warming drawer below another product,
refer to that product’s literature for any installation requirements.
Product Dimensions
WARMING
DRAWER
SIZE
24"
(61 cm)
27"
(68.6 cm)
30"
(76.2 cm)
OVEN
DEPTH (A)
23¹⁄₈"
(58.7 cm)
23¹⁄₈"
(58.7 cm)
23¹⁄₈"
(58.7 cm)
RECESSED
WIDTH (B)
22¹⁄₄"
(56.5 cm)
25¹⁄₄"
(64.1 cm)
28¹⁄₄"
(71.8 cm)
RECESSED
HEIGHT (C)
9"
(22.9 cm)
9"
(22.9 cm)
9"
(22.9 cm)
OVERALL
WIDTH (D)
23³⁄₄"
(60.3 cm)
26³⁄₄"
(67.9 cm)
29³⁄₄"
(75.6 cm)
DRAWER
FRONT
HEIGHT (E)
10¹⁄₄"
(26.1 cm)
10¹⁄₄"
(26.1 cm)
10¹⁄₄"
(26.1 cm)
3
Clearance Dimensions
E
D
Toe
kick
Warming
drawer
cutouts
120 volt
grounded
outlet
(or located
in adjacent
cabinet)
A
A
B
B
C
Front view
WARMING
DRAWER SIZE
MINIMUM
BETWEEN
CUTOUT
HEIGHT (B)
CUTOUTS (A)
24" (61 cm) 2¹⁄₂" (6.4 cm) 9¹⁄₈" (23.2 cm) 1" (2.5 cm)/
27" (68.6 cm) 2¹⁄₂" (6.4 cm) 9¹⁄₈" (23.2 cm) 1" (2.5 cm)/
30" (76.2 cm) 2¹⁄₂" (6.4 cm) 9¹⁄₈" (23.2 cm) 1" (2.5 cm)/
Warming drawer can be installed as an indoor single or double
installation or installed under a single oven. Two warming drawers
under a single oven are shown.
NOTE: The warming drawer cannot be leveled after being
installed.
For outdoor installation, follow the cutout dimensions above.
Install the outdoor warming drawer in a permanent fixture.
MINIMUM/
RECOMMENDED (C)
CUTOUT
WIDTH (D)
MINIMUM
CABINET
WIDTH (E)
22¹⁄₂" (57.1 cm) 24" (61 cm)
4¹⁄₄" (10.8 cm)
25¹⁄₂" (64.8 cm) 27" (68.6 cm)
4¹⁄₄" (10.8 cm)
28¹⁄₂" (72.4 cm) 30" (76.2 cm)
4¹⁄₄" (10.8 cm)
Custom Wood Drawer Front
If you plan to install a custom wood panel to match your
cabinets, we recommend consulting a qualified cabinetmaker or
carpenter. The back of the wood panel must be sealed to avoid
moisture damage.
4
Clearance Dimensions - Flush Installation
e
A
B
C
D
1" (25 mm)
Side Cleats*
⁷⁄₈” (22 mm)
Platform*
Front View
F
Side Cleat*
1⁵⁄₈" (4.1 cm)
Top View
E
Side View
Cabinet
Back
F
27" Models 30" Models
A Width of flush inset cutout (minimum) 27¹⁄₄" (69.2 cm) 30¹⁄₄" (76.8 cm)
B Height between cutouts (minimum) 2¹⁄₂" (6.4 cm) 2¹⁄₂" (6.4 cm)
C Height of flush inset cutout (minimum) 10³⁄₄" (27.3 cm) 10³⁄₄" (27.3 cm)
Bottom of cutout to floor (recommended) 8¹⁄₄" (21.0 cm) 8¹⁄₄" (21.0 cm)
D
Bottom of cutout to floor (minimum) 5" (12.7 cm) 5" (12.7 cm)
E Width of opening (minimum) 25¹⁄₄" (64.1 cm) 28¹⁄₄" (71.8 cm)
F Depth of cutout (minimum) 25³⁄₈" (64.5 cm) 25³⁄₈" (64.5 cm)
e Recommended outlet location
Flush Installation Requirements
A 25³⁄₈" (64.5 cm) minimum cutout depth is required.
These dimensions will result in a ¹⁄₄" (6 mm) reveal on all sides of the warming drawer.
The front face of the cleats and platforms will be visible and should be treated as a finished surface.
5