Kirisun TR850 User Manual

TR850 DMR Repeater Instruction Manual
II
TR850 DMR Repeater Instruction Manual
Instruction Manual
TR850
DMR Repeater
We are very grateful for your purchasing TR850 produced by Kirisun Communications
Co., Ltd. We believe TR850 can bring great convenience to your life and work.
TR850 DMR repeater which always incorporates the advanced technology and
exquisite craft, we hope that the quality and function of this product could make you
feel satisfied.
II
TR850 Digital Repeater
III
TR850 DMR Repeater Instruction Manual
Notice to User
Please read this Instruction Manual carefully before any operation to this product.
When you start to use the product, we deem that you have read this manual carefully.
Please save this Instruction Manual in a safe place for inference in need.
In order to preserve your rights and interests, please fill in the Warranty Card
seriously and actually when you purchase this product, and ask for the valid purchasing
certificate.
Kirisun and the authorized parties own the related intellectual property of all the
product parts include accessories. Any design and materials may not be modified, copied,
extracted or translated without the authorization of Kirisun or its authorized parties.
Due to the update or modification of the product, Kirisun owns the right to change the
specifications of software and hardware described in this manual without further notice.
Specifications and information contained in this manual are for reference only.
All described information in this manual are verified, if any missing or mistakes,
Kirisun reserves the rights to the interpretation of this manual.
II
TR850 DMR Repeater Instruction Manual
Safety Information
In order to use the indoor digital repeater effectively, please read the following
information.
This product can only be maintained by the professional technicians. Do not
disassemble the radio by yourself.
The repeater setting and mounting must be approved by the local Radio Management
Departments.
Installing the antenna of repeater must be do well of lightning protection, otherwise life
or property damage may be occurred.
Please use the qualified power, antenna, lightning protection device, power divider and
corresponding accessories and make sure they are installed correctly, otherwise
repeater damage will be occurred.
III
TR850 DMR Repeater Instruction Manual
Contents
1 Unpacking and checking.......................................................................................... 1
1.1 Standard Accessories.............................................................................................. 1
2 Radio Overview .......................................................................................................3
2.1 Power On/Off Button................................................................................................ 5
2.2 ACCY Connector .....................................................................................................5
2.2.1 Pin Instruction .......................................................................................................... 5
2.2.2 External Connector Instruction................................................................................. 7
2.3 LED Indicators ......................................................................................................... 8
3 Basic Operations .....................................................................................................9
3.1 Powering On/Off ...................................................................................................... 9
3.2 Voice and Data Transfer .......................................................................................... 9
3.3 IP Connecting .......................................................................................................... 9
3.4 Warning .................................................................................................................10
3.5 Programming Software ..........................................................................................10
3.5.1 File Menu ............................................................................................................... 10
3.5.2 Model Menu ........................................................................................................... 11
3.5.3 Edit Menu............................................................................................................... 11
4 Program Menu ....................................................................................................... 15
5 Installation Guide (refit guide) ................................................................................18
6 Frequently Asked Questions (FAQ) .......................................................................22
7 Recommend Duplexer Parameters........................................................................ 23
I
TR850 DMR Repeater Instruction Manual
1 Unpacking and Checking
Please unpack carefully and check all the items listed in the following table before discarding the
packing material. If any damage or loss occurs during shipment, please contact your dealer.
1.1 Standard Accessories
Item Quantity
Repeater 1
Foot pad4 pcs
1
Instruction Manual 1
1
TR850 DMR Repeater Instruction Manual
2
TR850 DMR Repeater Instruction Manual
2 Radio Overview
3
TR850 DMR Repeater Instruction Manual
No. Part Name
1 Handles
2 Frond Panel LED Indicators
3 Power Switch
4 GPS Antenna Connector
5 ACCY Connector
6 Network Connector(IP)
7 100-240V AC Cable Connector
8 GND Screw
9 Tx Connector
10 Fan
11 Cooler
12 RX Connector
13 13.6V DC Connector
4
TR850 DMR Repeater Instruction Manual
2.1 Power On/Off Button
Power on/off the repeater.
2.2 ACCY Connector
9
18
26
2.2.1 Pin Instruction
Pin Instruction
PIN1 Undefined
PIN2 Undefined
1
10
19
5
TR850 DMR Repeater Instruction Manual
PIN3 Undefined
PIN4 GND
PIN5 ACC_MAP_ID2: It is used for test.
PIN6 ACC_MAP_ID1: It is used for test.
PIN7 Undefined
PIN8 GND
PIN9 +SPEAKER
PIN10 -SPEAKER
PIN11 MIC
PIN12 GND
PIN13 Undefined
PIN14 Undefined
PIN15 Undefined
PIN16 GND
PIN17
PIN18 GND
PIN19 Undefined
PIN20 Undefined
PIN21 Undefined
External PTTHigh level is effective
6
TR850 DMR Repeater Instruction Manual
PIN22 PRGM_IO_7, External high level signal input
PIN23 Undefined
PIN24 Undefined
PIN25 Undefined
2.2.2 External Connector Instruction
The method to activate external PTT
Short connect the Pin17 with Pin22 of VGA to activate external PTT. It can test the transmitting
signal of repeater.
Test Analog Receiving
Short connect Pin5 with Pin22 of VGA.
Reset IP address
Short connect PIN6 with PIN22 of VGA to reset the IP and gateway address to the IP address on
the label, but it will not change data of IP address and gateway address, The IP address and
gateway address will recover to configure address after restart.
7
TR850 DMR Repeater Instruction Manual
2.3 LED Indicators
No.
1 TX-A Slot 1 transmitting indicator
2 RX-A Slot 1 receiving indicator
3 TX-B Slot 2 transmitting indicator
4 RX-B Slot 2 receiving indicator
5
6
Indicator Description
Repeater signal indicator
Analog mode indicator
7
8
9
Digital mode indicator
Alarm indicator
Power indicator
8
TR850 DMR Repeater Instruction Manual
3 Basic Operations
3.1 Powering On/Off
When the repeater is turned off, press the power switch " " to power on the repeater. Then the
light "
present working mode. Press
3.2 Voice and Data Transfer
The receiving and transmitting frequency are different on the repeater. Repeater will turn the weak
receiving signal into strong transmitting signal and transmit on the same channel. When
transmitting, the light
flashes. The receiving and transmitting frequency and CDCSS/CTCSS can be set by CPS.
An analog channel or a smart analog/digital detecting channel can be programmed with one group
of CDCSS/CTCSS encoding and decoding list. When receiving CDCSS/CTCSS on the channel,
repeater will transmit according to preprogrammed CDCSS/CTCSS encoding and decoding list.
3.3 IP Connecting
Default IP address192.168.1.100. Application update, parameters configuration and second
"is on. After the system working normally, the light " "、" " indicates the
to power off the repeater.
is on. If it is analog signal, flashes, if it is digital signal,
9
TR850 DMR Repeater Instruction Manual
development can be made through this port.
3.4 Warning
When unusual situation happens, warning indicator light will be enlightened. For example, when
Receiving Frequency unlocks, the warning light will flash once one second; Transmitting
frequency unlocks, the warning light will flash once two seconds; When both transmitting and
receiving frequency unlock, the alarm indicator will stay light on. When the repeater occurs
unusual situation, please let the related professional to check and recover the repeater.
3.5 Programming Software
IP connecting status should be checked before programming. Make sure that the network button
in the tools bar is pressed down, (If the button is not pressed down, the IP address bar will be grey,
disabled), also need to make sure the connect button is pressed down (the default status of
connect and network buttons are pressed down), under the status of connect button pressed
down, the software will connect to the repeater by the IP in the address bar. While the connectivity
is successfully built, the status bar will show “Network is OK”, or the address bar will show
“Network XX”. If other programming software connects to the repeater, the late connect software
will show“Repeater is busy”, then the connect button will pop up automatically, and need to press
the connect button to re-connect.
3.5.1 File Menu
10
TR850 DMR Repeater Instruction Manual
NewAdd new channel information, repeater will create new channel configuration files, a default
analog channel, and set the default configurations,
Open: Open a configuration file that saved in the storage device.
Save: Save the current channel configuration, in order to open the file conveniently next time.
If a new created channel or a channel read from the repeater, when saving them, you need to
select a new save path (similar with “save as”).
Save as: Select a new path to save the current configuration file.
Exit: Exit the software, if the configuration file has not been saved, software will ask user to save it.
3.5.2 Model Menu
Model Type: to select a model type, which includes the frequencies of 136MHz-174MHz,
400MHz-470MHz or custom frequency. The custom frequency cannot exceed the range of the
frequencies the repeater provides.
3.5.3 Edit Menu
General Setting
Device ID:Sets an individual ID that uniquely identifies the radio. In the Multiple Site IP system,
this ID is used to uniquely the different repeater.
Working Mode:Now, it only supports working in the single site.
11
TR850 DMR Repeater Instruction Manual
Work AloneWork as single repeater, not networking with other repeaters. Connect Working ModeIf exceed one single repeater’s coverage, this mode enables the
repeater to connect with other repeaters to expand the coverage.
Group Call Hang TimeWhen a terminal radio initiates a group call, and no PTT presses,
repeater shall hang on for a period of time. During this time, the channel is being taken up, and
communication is regarded still going, no accept to other signal relay. If any presses PTT, then the
hang time recounts. Once the hang time is over, this communication is over too, channel will be
released.
Value Range: 0~7000ms, the step is 500ms, the default value is 4000ms. Individual Call Hang Time: When a terminal radio initiates an individual call and no PTT presses,
repeater shall hang on for a period of time. During this time, the channel is being taken up, and
communication is regarded still going, no accept to other signal relay. If any presses PTT, then the
hang time recounts. Once the hang time is over, this communication is over too, channel will be
released.
Value Range: 0~7000ms, stepping is 500ms, the default value is 4000ms. Emergency Call Hang Time: When a terminal radio initiates an emergency call and no PTT
presses, repeater shall hang on for a period of time. During this time, the channel is being taken
up, and communication is regarded still going, no accept to other signal relay. If any presses PTT,
then the hang time recounts. Once the hang time is over, this communication is over too, channel
will be released.
12
TR850 DMR Repeater Instruction Manual
Value Range0~7000ms, stepping is 500ms, the default value is 4000ms. Calling Hang Time: When a call ends, the repeater will hang on for a period of time, during this
time, when a terminal radio presses the PTT, no need to build connect again, just communicate
directly.
Value Range: 0~7000ms, the stepping is 500ms, the default value is 4000ms. Network Setting: When networking, different repeaters can address to build a connecting by
setting the network parameters.
Local IP: The IP address of repeater, like 192.168.1.100. Local Port: The repeaters use the UDP local port to connect to the server. The range of the port
is 0~65535.
Server IP: When networking, the IP of the server that repeater connects to. Server Port: The repeater uses TCP server, TCP server connects needs a specific server port.
The range value of the port is from 0~65535.
Gateway IPWhen networking, the gateway IP that repeaters interconnect to each other. Transmit Frequency: To set the transmit frequency in the current channel. The range cannot
exceed what the repeater limits.
Receive Frequency: To set the receive frequency in the current channel. The range cannot
exceed what the repeater limits.
Power: To select current channel’s RF power level Fan Control: User can set the Fan Work Threshold, Power Amplifier Protect Threshold and
13
TR850 DMR Repeater Instruction Manual
Standing Wave Ratio.
Power Amplifier Protect Threshold: As long as the temperature is higher than the threshold
value, it stops working , the default threshold value is 80 Fan Work Threshold: As long as the temperature is higher the threshold value, the fan starts
working. The default threshold value is 45℃. Fan Stop Work ThresholdAs long as the temperature is higher the threshold value, the fan
stops working. The default threshold value is 35℃. Standing Wave Ratio: It is used to shows if it’s the antenna match with the radio. The default
value is 3.0
Bandwidth: It’s used to select the channel spacing of the current channel. Options are, 12.5 kHz,
20 kHz, 25 kHz, the default option is 12.5 kHz.
Colour Code: It is used to select the colour code of the current channel. As long as the radios
with same colour code in the same frequency can communicate with each other.
Value Range: 0~15, default value is 1. Squelch Type: It is used to select the receive mode of current channel. Options: CSQ, CTCSS, CDCSS, -CDCSS.
Default Option: CSQ
Squelch Level: It is used to set the squelch electrical level. CTCSS: If select this option, needs to select a CTCSS value, or the transmitter and receiver
14
TR850 DMR Repeater Instruction Manual
cannot communicate with each other.
Value Range: The CTCSS ranges from 0~254.1Hz, the stepping is 0.1 Hz, default value is 67 Hz. CDCSS: If select CDCSS or –CDCSS, needs to select a CDCSS value, or the transmitter and
receiver cannot communicate with each other.
Value Range: 0~777(octal number), the stepping is 1, the default value is 023.
Notes:
1. Squelch level only use for analog channel.
2. Mix channel cannot select CSQ, must select CTCSS, CDCSS or –CDCSS.
4 Program Menu
Read DataRead data from the repeater
When reading data, a bar pops up and shows the reading process. When finish reading, software
will pop up a dialog box, shows “Read data successfully”.
When you try to read data, tick the option “Exit after finish”, when finish reading data, the dialog
box will exit automatically. If not tick this option, users have to press “Exit” manually to close the
box.
Write Data: Write the configurations into the repeaters.
When writing data, a bar pops up and shows the writing process. When finish writing, software will
15
TR850 DMR Repeater Instruction Manual
pop up a dialog box, shows“ Write data successfully”.
When you try to write data, tick the option “Exit after finish”, when finish writing data, the dialog box
will exit automatically. If not tick this option, users have to press “Exit” manually to close the box.
Notes
(1) When try to read data, have to check the network, make sure the program menu tick the
“Network” option, make sure the IP on the tools bar is the IP of the repeater you are going to
program.
(2) When the connectivity is successful, the top of the dialog box of “Reading data” and status bar
will show “Network is OK”, otherwise will be shown “Network XX”.
Upgrade software: the main function is to download different function modules from PC to the
repeater, then set the main parameters on them.
Under the “Program” menu, find “Program Download”, then you can upgrade. But before
upgrading, you should select the path of the update package. If is a standard update package,
after select the path, each update file’s paths will be auto filled. Upgrade Boot Loader
1Before upgrading, repeater should be power off, boot mode select 0101, select “Download
boot loader” and find the correct serial port between PC and repeater. If necessary, select the boot
loader file and uboot file.
2Press “Download” button, then a upgrade dialog box pops up, select “Yes”.
3When the control program shows “Wait for boot me……” the interface power on (Note: if the
16
TR850 DMR Repeater Instruction Manual
below interface flashes back, maybe fail to open the serial port. Please check the serial port
connectivity, or other program takes up the serial port.
4if the update is finished, software will note that. Please don’t forget to switch the boot mode
back to 1000. Upgrading the System
1Boot mode should be 1000 while upgrading. Choose the system programs to be downloaded,
and remove unnecessary components according to needs. (For example: if the repeater could
work normally and connecting the PC network before upgrade, then you could remove the hook
behind the environment variable).
2Click “download” button to proceed. When upgrading, there is a progress bar to show the
upgrading status. And there will be a prompt message after the process is finished. Upgrading the system
1Boot mode should be 1000 while upgrading. Choose the system programs to be downloaded,
and remove unnecessary components according to needs.
2Click “download” button to proceed. When upgrading, there is a progress bar to show the
upgrading status. And there will be a prompt message after the process is finished.
17
TR850 DMR Repeater Instruction Manual
5 Installation Guide (refit guide)
Duplexer Installation
1DisassemblyAs the figure below, take off the 4 screws and 6 screws of two sides of the top
cover, and then slightly open the top cover.
18
TR850 DMR Repeater Instruction Manual
2Take off the two screws of duplexer baffle, remove the duplexer.
19
TR850 DMR Repeater Instruction Manual
3Slightly loosen the two screws of fixed duplexer bracket on installed clapboard to the bracket,
and do not too loosen. Refer to following figure.
20
TR850 DMR Repeater Instruction Manual
4Fixed the duplexer tail screws to the duplexer bracket. Push the duplexer to the end three
duplexer connection holes until the duplexer is locked. Then fasten the duplexer bracket and
install screw. Refer to following figure.
21
TR850 DMR Repeater Instruction Manual
6 Frequently Asked Questions (FAQ)
Can’t connect to the PC programming software
The IP of repeater input is error in the programming software. Or the user forgets the IP of
repeater.
Can’t transfer
Please confirm the frequency and the working mode of the radio is the same with the repeater.
22
TR850 DMR Repeater Instruction Manual
7 Recommend Duplexer Parameters
Model SGQ-450 A / D
Frequency Range(MHz)
BandwidthKHz
Frequency Spacing(MHz)
Insertion Loss(dB)
Isolation (dB) >80
Suppression(dB) >80
V.S.W.R <1.3
NormaI lmpedance
Max Power Input(W)
Standard Termination N/BNC
Dimensionsmm
WeightKG
380~520
±400
10
<1.0
50
30 / 50
223×154×31.5
223×191×39
1.2 / 2.0
23
TR850 DMR Repeater Instruction Manual
24
Loading...