Kipor Sinemaster IG3000 Operation Manual

PREFACE
Thank you for purchasing a Kipor Generator.
This manual covers the operation and preventive maintenance of the IG3000 generator with EPA and r
California Air Resources Board (CARB) certification if so designated.
printing.
We reserve the right to make changes at any time without notice and without incurring any obligation.
No part of this publication may be reproduced without written permission.
This manual should be considered a permanent part of the generator and should remain with it if it is
resold.
Pay special attention to statements preceded by the following words:
Failure to properly follow these precautions can result in property damage,
serious injury or DEATH!
Read all labels and the owner's manual before operating this generator.
Generators produce carbon monoxide, a poisonous, colorless, odorless gas that can cause death or
serious injury.
Indoor use of a generator can kill quickly. Generators should be used outdoors only.
Generators should be used outdoors only and away from garages and open windows and protected
from rain and snow.
Always stop engine before refueling. Wait 5 minutes before restarting.
Keep any source of ignition away from the fuel tank at all times.
The portable generator is not meant to be used as a permanent back-up power system for the home. A
permanently installed stationary generator is designed to be safely used for this specific purpose.
Indicates a strong possibility of severe personal injury or death if instructions are
not followed.
Indicates a possibility of personal injury or equipment damage if instructions are
not followed.
NOTE Gives helpful information.
If a problem should arise, or if you have any questions about the generator, consult an authorized
dealer or service center.
Our generators are designed to give safe and dependable service if operated
according to the instructions. Read and understand the Owner's Manual before
operating the generator. Failure to do so could result in personal injury or
equipment damage.
CONTENTS
1. SAFETY INSTRUCTIONS ··································································································1
2. COMPONENT LOCATIONS ······························································································· 3
2.1 Outside View·················································································································· 3
2.2 Control Panel ·················································································································4
2.3 Serial Number Location ·································································································4
3. PRE-OPERATION CHECK ································································································· 5
3.1 Engine Oil ······················································································································ 5
3.1 Fuel································································································································ 6
3.3 Air Cleaner····················································································································· 7
4. STARTING THE ENGINE ··································································································· 8
4.1 Starting Procedure········································································································· 8
4.2 High Altitude Operation ······························································································· 10
4.3 Ambient Temperature··································································································10
5. GENERATOR USE ···········································································································11
5.1 Warnings and Cautions······························································································· 11
5.2 AC Power Applications································································································12
5.3 Output and Overload Indicators ·················································································· 12
5.4 Overload Reset Switch ································································································ 15
5.5 Smart Throttle ·············································································································· 14
5.6 Air Conditioning Operation ··························································································14
5.7 DC Power Operation ··································································································· 15
5.8 Low Oil Alarm System ································································································· 16
6. STOPPING THE ENGINE································································································· 17
6.1 Normal Shutdown········································································································17
6.2 Emergency Stop··········································································································17
7. MAINTENANCE ················································································································18
7.1 Emission Control System ························································································· 18
7.2 Maintenance Schedule································································································20
7.3 Changing Oil················································································································20
7.4 Air Cleaner Service······································································································ 21
7.5 Spark Plug Service······································································································22
7.6 Spark Arrestor Maintenance························································································ 23
8. TRANSPORTING/STORAGE ··························································································· 24
8.1 Transporting················································································································· 24
8.2 Extended Storage ········································································································24
8.3 Fuel Treatment and Generator Exercise····································································· 24
9. TROUBLESHOOTING ······································································································ 25
10. SPECIFICATIONS ·········································································································· 27
11. WIRING DIAGRAM ·········································································································28
12. WHEEL KIT INSTALLATION ··························································································29
13. WARRANTY ···················································································································· 30
13.1 Limited Warranty- Kipor Power Products ································································30
13.2 Emission Control Warranty ······················································································ 31
13.2 California Emissions Control Warranty Statement··················································33
14. EMISSION CONTROL SYSTEM···················································································· 34
1
1. SAFETY INSTRUCTIONS
Our generators are designed to give safe and dependable service if
operated according to these instructions.
Read and understand the owner's manual before operating the
generator. Failure to do so could result in personal injury or
equipment damage.
Exhaust gas contains poisonous carbon monoxide.
Never run the generator in an enclosed area.
Be sure to provide adequate ventilation.
The muffler becomes very hot during operation and remains hot for
several minutes after stopping the engine.
Be careful not to touch the muffler while it is hot.
Let the engine cool before storing the generator indoors.
The engine exhaust system will be heated during operation and
remain hot immediately after stopping the engine.
To prevent scalding, pay attention to the warning marks attached to
the generator.
The generator must be operated outside with adequate ventilation. It
cannot be operated in an enclosed compartment of any vehicle or
garage area.
2
To ensure safe operation:
Gasoline is extremely flammable and explosive under certain
conditions. Refuel in a well ventilated area with the engine stopped.
Keep away from smoking materials, sparks and other sources of
combustion when refueling the generator. Always refuel in a
well-ventilated location.
Wipe up spilled gasoline at once.
Restrict application of generator in high-hazard risk to causing fire area.
Connections for standby power to a building's electrical system must
be made by a qualified electrician and must comply with all applicable
laws and electrical codes. Improper connections can allow electrical
current from the generator to back feed into the utility lines. Such
back feed may electrocute utility company workers or others who
contact the lines during a power outage, and when utility power is
restored, the generator may explode, burn, or cause fires in the
building's electrical system. This generator is not designed to be
connected to an automatic transfer switch. Serious damage to the
engine and inverter module may result.
Always make a pre-operation inspection before you start the engine.
Place the generator at least three feet or one meter away from
buildings or other equipment during operation.
Operate the generator on a level surface to prevent fuel spillage or oil
starvation.
Know how to stop the generator quickly and understand operation of
all the controls. Never permit anyone to operate the generator
without proper instructions. Keep children and pets away from the
generator when it is in operation.
Never operate the generator with the door open or any panels
removed. Do not operate in any enclosure such as an RV
compartment.
Keep away from rotating parts while the generator is running.
The generator is a potential source of electrical shocks when
misused; do not operate with wet hands.
Do not operate the generator in rain or snow or let it get wet.
3
2. COMPONENT LOCATIONS
2.1 Outside view
Carbon Canister
Spark plug
Oil dipstick
Service
door
Battery
Air filter
Air intake
Control panel
Fuel level indicator
Fuel filler cap
Air quality index
Air exhaust
Muffler warning
Starter grip
4
2.2 Control panel
2.3 Serial Number and Bar Code Location:
The engine serial number is stamped on the engine block to the left of the oil drain plug. In most cases
the battery will have to be removed to view it clearly. Refer to this number when ordering parts or
making technical inquiries.
Engine serial number
Please record this information below and keep this manual in a safe place along with the bill of sale.
Serial Number __________________________________
Date of Purchase ________________________________
Place of Purchase ________________________________
SMART throttle switch
DC receptacle
Ignition Module
Engine switch
Choke knob
Fuel valve lever
Ground terminal
AC receptacle
Overload protection device
Engine serial number
Overload Reset Switch
5
3. PRE-OPERATION CHECK
Be sure to check the generator on a level surface with the engine stopped. Under no circumstances
can this generator be installed in an enclosed compartment.
3.1 Engine Oil Level
Using non-detergent oil or 2-stroke engine oil could shorten the
engine's service life.
Use a high-detergent, premium quality 4-stroke engine oil, certified to
meet or exceed U.S. automobile manufacturer's requirements for API
Service Classification SG/SF.
Select the appropriate viscosity for the average temperature in your
area.
SAE Viscosity Grades
Open the left maintenance cover. Remove and wipe the oil dipstick with a clean rag. Check the oil level by
inserting the dipstick in the filler hole, tighten the dipstick and screw it out. If the oil level is below the end of
the dipstick, refill with recommended oil to the top of the oil filler neck.
Single
viscosity
Multi-
viscosity
Ambient Temperature
Upper limit
Lower limit
Dipstick
6
Running the engine with insufficient oil can cause serious engine
damage.
The Low Oil Alarm System will automatically stop the engine before
the oil level falls below a safe limit. However, to avoid the
inconvenience of an unexpected shutdown, it is still advisable to
visually inspect the oil level regularly.
3.2 Fuel
Fuel tank capacity- 3.1 gal (11.6 L)
Use unleaded 87 octane regular grade automotive gasoline.
If the fuel level is low, refill to the shoulder of the fuel strainer, see fig.4.
Never use an oil/gasoline mixture or dirty gasoline.
Avoid getting dirt, dust or water in the fuel tank.
After refueling, tighten the fuel filler cap securely.
Gasoline is extremely flammable and is explosive under certain
conditions.
Refuel in a well-ventilated area with the engine stopped. Keep all
smoking materials, sparks, and any other source of combustion away
from the generator during refueling.
Do not overfill the fuel tank (there should be no fuel in the filler
neck). After refueling, make sure the fuel filler cap is closed
properly and securely.
Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor
may ignite. If any fuel is spilled, make sure the area is dry before
starting the engine.
Avoid repeated or prolonged contact with skin or breathing of vapor.
KEEP OUT OF REACH OF CHILDREN.
Fuel surface
Fuel surface
Strainer
Fuel filler cap
7
Gasoline containing alternate fuels:
If you decide to use a gasoline containing ethanol, be sure its octane rating is no lower than the
specification. Do not use a blend that contains more than 10% ethanol. Do not use any gasoline
containing methanol.
3.3 Air Cleaner
Check the air cleaner element to be sure it is clean and in good condition.
Open the left side maintenance cover. Remove the air cleaner cover, remove the paper element from
the air cleaner cover, and check the element, Replace the element if dirty or the filter paper is torn.
Never run the engine without the air cleaner. Rapid engine wear will
result from contaminants such as dust and dirt being drawn through
the carburetor into the engine.
Air cleaner base
Air cleaner element
Air cleaner cover
8
4. STARTING THE ENGINE
When starting the generator after adding fuel for the first time or after
long term storage, or after running out of fuel, turn the fuel valve lever
to the "ON" position, then wait for 10 to 20 seconds before starting
the engine.
4.1 Starting Procedure
4.1(a) Turn the fuel valve lever to the ON position.
Fig.6
4.1(b) Pull the choke knob out to the CLOSED position
Do not use the choke if the engine is already warm or the ambient air temperature is high.
Fig.7
Fuel valve lever
Choke knob