Kipor Sinemaster IG2600, Sinemaster IG2600h Operation Manual

SINEMASTER
DIGITAL INVERTER GENERATOR
IG2600 IG2600h
WUXI KIPOR POWER CO., LTD.
12. SKETCH MAP
IG2600h movement state IG2600h placed state
PREFACE
Thank you for purchasing our generators.
This manual covers operation and maintenance of the IG2600, IG2600h generator.
All information in this publication is based on the latest product information available at the time of approval for printing.
We reserve the right to make changes at any time without notice and without incurring any obligation.
No part of this publication may be reproduced without written permission.
This manual should be considered a permanent part of the generator and should remain with it if it is resold.
Pay special attention to statements preceded by the following words;
Failure to properly follow these precautions can result in property damage, serious injury or DEATH! Read all labels and the owner's manual before operating this generator. Operate only in well ventilated areas. Exhaust gas contains poisonous carbon monoxide, and can be deadly. Always stop engine before refueling. Wait 5 minutes before restarting. Check for spilled fuel or leaks. Clean and/or repair before use. Keep any sources of ignition away from fuel tank, at all times.
Indicates a strong possibility of severe personal injury or death if instructions are not followed.
Indicates a possibility of personal injury or equipment damage if instructions are not followed.
NOTE: Gives helpful information.
If a problem should arise, or if you have any questions about the generator, consult an authorized dealer.
Our generators are designed to give safe and dependable service if operated according to instructions. Read and understand the Owner's Manual before operating the gen­erator. Failure to do so could result in personal injury or equipment damage.
The illustration may vary according to the type.
WARNING
CAUTION
WARNING
WARNING
11. SPECIFICATIONS
DC output
DC voltage
Electric circuit breaker
No. of Phase
12V-8.3A
Available
Single phase
Model
IG2600/IG2600h
Rated frequency (Hz)
Rated voltage (V)
Rated current (A)
Rated speed (rpm)
Rated output (kVA)
Max output (kVA)
50
230
10
3600
2.3
2.6
60
240
9.6
Engine
Model Type
KG171
Type
Displacement (Bore Stroke)
Compression ratio
Rated power (kW)
Rated rotation speed (rpm)
Ignition system
Spark plug
Starting system
Fuel
Fuel consumption (g /kW.h)
Lube oil
Single cylinder, 4 stroke, vertical, air-cooled, OHV, gasoline engine
171ml (66 55mm)
8.5:1
3.5/3600
3600
T. C. I
R6-388
Recoil starter
Automotive unleaded gasoline
450
SAE 10W30 (above CC grade)
Fuel tank capacity (L)
Continuous running time (hr) (at rated output)
Noise level(zero load~ full load) [dB(A)/7m]
Overall dimension (L W H) [mm(in)]
4.8
2.5
58-63 *
Dry weight [kg(lbs)]
IG2600: 26 (57.2) IG2600h: 27.5 (60.5)
IG2600: 564 317 453(22.20 12.48 17.83) IG2600h: 590 330 480 (23.23 12.99 18.90)
60
120
19.5
CONTENTS
1. Safety Instructions
2. Safety Label Locations
3. Component Indentificaction
4. Pre-operation Check
5. Starting the Engine
High altitude operation
6. Generator Use
7. Stopping the Engine
8. Maintenance
9. Transporting/Storage
10. Troubleshooting
11. Specifications
12. Sketch Map
1
3
4
7
10
12
13
21
23
29
31
33
34
*: The declared values shall consider uncertainties due to production variation and measurement procedures.
Is the overload indicator light ON?
Appliance does not operate:
Is the output indicator light ON?
NO
NO
YES
YES
YES
NO
Take the generator to an authorized dealer.
Take the generator to an authorized dealer.
Check the electrical appli­ance or equipment for any defects.
Replace the electrical
appliance or equipment
Take the electrical appli­ance or equipment to an electrical shop for repair
Push the reset button.
YES
No electricity at the DC receptacle:
Is DC circuit breaker tripped?
Take the generator to an authorized dealer.
NO
1. SAFETY INSTRUCTIONS
WARNING
WARNING
WARNING
Exhaust gas contains poisonous carbon monoxide.
Never run the generator in an enclosed area.
The muffler becomes very hot during operation and
remains hot for a while after stopping the engine. Be careful not to touch the muffler while it is hot. Let the engine cool before storing the generator indoors. The engine exhaust system will be heated during op­eration and remain hot immediately after stopping the engine. To prevent scalding, pay attention to the warning marks attached to the generator.
Our generators are designed to give safe anddepend-
able service if operated according to instructions. Read and understand the Owner's Manual before op­erating the generator. Failure to do so could result in personal injury or equipment damage.
Be sure to provide adequate ventilation. When installed in ventilated protection are to be observed.
To ensure safe operation--
WARNING
WARNING
WARNING
Gasoline is extremely flammable and explosive under certain conditions. Refuel in a well ventilated area with the engine stopped.
Keep away from cigarette, smoke and sparks when re-
fueling the generator. Always refuel in a well-ventilated location.
Wipe up spilled gasoline at once.
Connections for standby power to a building's electrical
system must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Im­proper connections can allow electrical current from the generator to back feed into the utility lines. Such back feed may electrocute utility company workers or others who contact the lines during a power outage, and when utility power is restored, the generator may explode,burn or cause fires in the building's electrical system.
Always make a pre-operation inspection before you start the engine. You may prevent an accident or equipment damage.
Place the generator at least 1m(3ft) away from build-
ings or other equipment during operation.
Operate the generator on a level surface.
If the generator is tiled, fuel spillage may result.
Know how to stop the generator quickly and understand
operation of all the controls.Never permit anyone to op­erate the generator without proper instructions.
Keep children and pets away from the generator when
it is in operation.
Keep away from rotating parts while the generator is
running.
The generator is a potential source of electrical shocks
when misused; do not operate with wet hands.
Do not operate the generator in rain or snow and do not
let it get wet.
10.TROUBLESHOOTING
When the engine will not start:
Is there fuel in the tank?
Is the engine switch on?
YES
YES
YES
Is there enough oil in the engine?
Is there a spark from the spark plug?
NO
NO
NO
NO
Refill the fuel tank.
Turn the engine switch on.
Add the recommended oil.
Still no spark
Replace the spark plug.
Take the generator to an authorized dealer.
WARNING
If the engine still does not start, take the generator to an authorized dealer.
Be sure there is no spilled fuel around the spark pulg.
Spilled fuel may ignite.
To check:
1)Remove the spark plug cap and clean any dirt from around the spark plug.
2)Remove the spark plug and install the spark plug in the plug cap.
3)Set the plug side electrode on the cylin­der head to ground.
4)Pull the recoil starter, sparks should jump across the gap.
Oil level
Choke lever
Engine switch
Model
Hot caution
Drain Screw
Starter Grip
2. SAFETY LABEL LOCATIONS
These lables warn you of potential hazards that can cause serious injury. Read the labels and safety notes and precautions described in this manual carefully. If a label comes off or becomes hard to read, contact you dealer for a replace ­ment.
a. Drain all gasoline from the fuel tank into an approved gasoline container. b. Turn the engine switch ON, and loosen the carburetor drain screw and drain the gasoline from the carburetor into a suitable container. c. With the drain screw loosened remove the spark plug cap, and pull the starter grip 3 to 4 times to drain the gasoline from the fuel pump. d. Turn the engine switch to the OFF position, and tighten the drain screw securely.
5.Slowly pull the starter grip until resistance is felt. At this point, the piston is coming
3. Change the engine oil.
4. Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder.
Crank the engine several revolutions to distribute the oil, then reinstall the spark plug.
up on its compression stroke and both the intake and exhaust valves are closed. Storing the engine in this position will help to protect it from internal corrosion.
Safety caution
Loading...
+ 13 hidden pages