30 0011110 40 0101000 50 0110010 60 0111100
31 0011111 41 0101001 51 0110011 … ………
32 0100000 42 0101010 52 0110100 … ………
33 0100001 43 0101011 53 0110101 127 1111111
34 0100010 44 0101100 54 0110110 note:1=ON,0=OFF
explain:DIP switch to digital is "OFF",The corresponding number is
0,Dial “ON”, The corresponding number is 1。
7 DIP switch is address code switch, adopt binary coding, can setting 128
different address code, 9 is low, 3 is high, encode according from low to high
Address calculation method:( Below is the switch “ON” the state of the value in)
switch: 3 4 5 6 7 8 9
value: 64 32 16 8 4 2 1
1, select the mann yards agreement, the address code number starting from 0,
the maximum set to 128, which corresponds to the matrix decoder addresses
the camera 1 to 0; when the system is used in more than 64 decoder should
use the code distributor to achieve expansion.
2, Shanghai Chenova system for all agreements and KODICOM system
KRE-301 protocol address encoded as 16 hex mode, the system address is
"10", the actual address of the corresponding decoder 16.
3, part of the system, PELCO P / HY protocol address is 1, the software is set to
1, corresponding to the address decoder is set to 2.
9、Auto recognition agreements list:
agreements name Adaptive System agreements name Adaptive System
Pelco D DVR ST-832 HDD SYSTEM
Pelco P DVR Pelco D WX HDD SYSTEM
CS850 DVR HIKVISION DVR
1、Feature
Special Designed Camera, IR LED Partition Ray System, Without
Glisten Phenomenon.
Used the powerful IR LED from Taiwan, Qualified Disperse Heat
solution to avoid part warm up.
Constant power supply to ensure the IR LED for long time working.
IR LED Board has the Windy Circle system; Once the LED on, it
works.
When long distance watching, the IR field can be adjusted.
Powerful power supply, stable electricity and pressure suitable for
long time working.
Double Anti-sunshine structure, weatherproof for out door/ In door
using.
Acrylics Optics Housing, No distortion.
2、Attentions:
☆ Don't be installed in the indoor of the equipment exposed to rain or
moisture
☆ Don't be put inside the device objects, which could cause a
short-circuit and damaged equipment or system;
☆ Avoid installation in flammable and explosive gas or corrosive gas
exists;
☆ Don't remove pan-tilt internal components and parts and repair itself;
☆ Don't exceed the environment temperature, humidity standards;
☆ AC24V power supply for pan-tilt, DC12V power supply for infrared
lamp, Please confirm by strict specifications, higher than the voltage
access the voltage specification access will cause equipment burn。
3
10