Kino Flo VistaBeam 600, VistaBeam 300 Operation Manual

Operation Manual
VistaBeam 600 & 300
Part No. 3100041 Rev C 01-07-2008
VIS-6C-120
VistaBeam 600 Center Mount, 120VAC
VIS-6C-230
VistaBeam 600 Center Mount, 230VAC
VIS-3C-120
VistaBeam 300 Center Mount, 120VAC
VIS-3C-230
VistaBeam 300 Center Mount, 230VAC
LVR-V690
VistaBeam 600 Louver–Honeycomb 90° (Included)
LVR-V390
VistaBeam 300 Louver-Honeycomb 90° (Included)
GFR-V6
VistaBeam 600 Gel Frame (Included)
GFR-V3
VistaBeam 300 Gel Frame (Included)
LVR-V690
VistaBeam 600 Louver–Honeycomb 90°(Included)
LVR-V390
VistaBeam 300 Louver-Honeycomb 90° (Included)
GFR-V6
VistaBeam 600 Gel Frame (Included)
GFR-V3
VistaBeam 300 Gel Frame (Included)
VIS-6Y-120
VistaBeam 600 Yoke Mount, 120VAC
VIS-6Y-230
VistaBeam 600 Yoke Mount, 230VAC
VIS-3Y-120
VistaBeam 300 Yoke Mount, 120VAC
VIS-3Y-230
VistaBeam 300 Yoke Mount, 230VAC
KIT-V6C-120 VistaBeam 600 Center Kit, 120VAC
KIT-V6C-230 VistaBeam 600 Center Kit, 230VAC
Kit Contents:
1 VistaBeam 600 w/ Center Mount 1 VistaBeam Louver 90° 1 Ship Case
Dimensions
41.5 x 15.5 x 44" (105.5 x 39.5 x 112cm)
Weight 140lb (63kg)
KIT-V6C-120/2 VistaBeam 600 Center Mount Kit, 120VAC (2-Unit)
KIT-V6C-230/2 VistaBeam 600 Center Mount Kit, 230VAC (2-Unit)
Kit Contents:
2 VistaBeam 600 w/ Center Mount 2 VistaBeam Louver 90° 1 Ship Case
Dimensions
41 x 27 x 44" (102.5 x 67.5 x 112cm)
Weight 205lb (93kg)
KIT-V3C-120 VistaBeam 300 Center Kit, 120VAC
KIT-V3C-230 VistaBeam 300 Center Kit, 230VAC
Kit Contents:
1 VistaBeam 300 w/ Center Mount 1 VistaBeam Louver 90° 1 Ship Case
Dimensions
42 x 14.5 x 25.5" (107 x 37 x 65cm)
Weight
82.3lb (37kg)
1. 2.
3. 4.
1) Open the two hinged reflector panels. 2 & 3) Insert the lamp base into the lamp connector. 4) Insert the lamp tip into the lamp clip. Close the reflector panels.
Align the pins of the Gel Frame with the inner (closest to lamps) holes of the Accessory Holder. Pull back the pins and release into the holes to secure the gel frame.
(A) (B)
A) The Gel Frame comes with Gel Clips. Cut the gel to size and
use the Clips to fasten the gel to the Frame.
B)
Another method is to apply transfer tape directly to the gel
frame. The clips are not necessary when taping the gel.
Align the pins of the louver with the outer (farthest from lamps) receptacle holes on the Accessory Holder. Pull back the pins and release into the hole to secure the louver.
The large holes on the Accessory Holder can be used as rigging points; for example a 4 point rope hang.
Loading...