Kingston Technology KNE16TP, KNE24TP, KNE16RS, KNE24RS User Manual

Kingston Technology EtheRx Pro-Series 19” Rack-Mount Stackable 10BASE-T Ethernet Hubs User’s Guide
Models: KNE16TP/RS KNE24TP/RS
Kingston Technology’s
EtheRx Pro-Series
16-Port and 24-Port
Stackable 19-inch Rack-Mount
10BASE-T Ethernet Hubs
User’s Guide
Part No. 4460053-001.A01
Kingston Technology Company
17600 Newhope
Fountain Valley, CA 92708
(714) 435-2600
KNE24TP/RS User’s Guide - Rev. A01 Kingston Technology Company
Important Safety Instructions
1. Read all these instructions.
2. Save these instructions for later use.
3. Follow all warnings and instructions marked on the product.
4. Do not use this product near water.
5. This product should be operated from the type of power source indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company.
6. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous voltage points or other risk. Refer all servicing to service personnel.
Wichtige Sicherheitshinweise
1. Diese Hinweise sollten vollständig durchgelesen werden.
2. Diese Hinweise für einen späteren Gebrauch aufbewahren.
3. Allen auf dem Gerät angebrachten Warnungen und Hinweisen folgen.
4. Das Gerät nicht in der Nähe von Wasser verwenden.
5. Das Gerät nur mit dem Aufkleber bezeichneten Netzspannung betreiben. Bei Fragen über die Art der Netzspannung sollte der Händler oder das Energieversorgungsunternehmen zu rate gezogen werden.
6. Nicht versuchen das Produkt selbst zu reparieren. In allen Produkten
existieren gefährliche elektrische Spannugen. Nicht das Gehäuse öffnen.
Kingston Technology Company KNE24TP/RS User’s Guide - Rev. A01
i
TABLE OF CONTENTS
Introduction
Special Features............................................................................2
Package Contents .........................................................................2
Design Features
Repeater Functions .......................................................................3
Jabber Lock-up Protection.............................................................3
Fragment Extension.......................................................................3
Collision-Handling..........................................................................3
Automatic Partitioning/Reconnection.............................................4
Link Test ........................................................................................4
Hardware Installation
Front Panel ....................................................................................5
Power LED ....................................................................5
Utilization LEDs .............................................................5
Collision LEDs ...............................................................5
AUI LED.........................................................................6
BNC LED .......................................................................6
UTP Port LEDs ..............................................................6
Cascade Switch.............................................................7
Rear Panel.....................................................................................8
Power Switch.................................................................8
KNE24TP/RS User’s Guide - Rev. A01 Kingston Technology Company
ii
AC Power Connector .................................................... 8
AUI Port ........................................................................ 8
BNC Port....................................................................... 8
Stacking Ports............................................................... 8
Stacking EtheRx Hubs .................................................................. 9
Network Configurations
Ethernet 5-4-3 Rule..................................................................... 10
Ethernet Star Network................................................................. 10
Linear Bus Network..................................................................... 11
Horizontal Cascading.................................................................. 11
Cascading with Stacked Hubs .................................................... 12
Appendices
Appendix A Pin Assignments................................................... 14
Appendix B Cabling Guidelines ............................................... 16
Appendix C Specifications ....................................................... 19
Appendix D Mounting Templates............................................. 21
Appendix E Product Warranties and Notices........................... 22
Limited Warranty Statement ....................................... 22
Duration of Warranty................................................... 23
Free Technical Support .............................................. 23
Disclaimers ................................................................. 23
FCC Certification / CE Notice ..................................... 24
Kingston Technology Company KNE24TP/RS User’s Guide - Rev. A01
General Information 1
Introduction
Intended Audience: This manual assumes that the user has a general working knowledge of networking principles and architecture and is familiar with network systems in general.
Congratulations on the purchase of your new Kingston Pro-Series® 19-inch rack-mount, stackable 10BASE-T Ethernet Hub. There are two models: the KNE16TP/RS and KNE24TP/RS, 16-Port and 24-Port Ethernet hubs, respectively. The Pro-Series models offer several new enhancements. The
Stack-n-Play
ID switches. The Hot-Stack down. The Smart Monitor bar-graph LED display.
The EtheRx hubs provide sixteen (16) or twenty-four (24) UTP (Unshielded Twisted-Pair) ports for 10BASE-T Ethernet connections, one BNC port for 10BASE2 thin Ethernet connection, and one AUI (Attachment Unit Interface) port for either 10BASE2 Cheapernet, 10BASE5 thick Ethernet, 10BASE-T, 10BASE-FL, or FOIRL (Fiber Optic Inter Repeater Link) segment using a proper external transceiver. The last UTP port (i.e., Port 16 or Port 24) uses a cascade switch to support both crossover and straight-thru cable wiring for uplinking to another 10BASE-T hub.
The EtheRx models can also be stacked up to five hubs using the stacking cable (provided) expanding your network to a maximum of 80 or 120 UTP ports (depending on the model) as a single repeater unit. The EtheRx hubs can be used on desktop or 19-inch rack-mount installations (mounting hardware included). The front panel includes pull handles for rack-mounting and a variety of diagnostic LEDs including: Power, five levels of Utilization and Collision status, AUI, BNC, and UTP port LEDs which display Link, Activity and Partition status.
®
feature allows for easy installation without the need to configure
®
feature allows adding new hubs without powering
®
feature offers network traffic monitoring through a
7865
Stackable Ethernet Hub
UTIL %
PWR
COLL %
Stackable Ethernet Hub
UTIL %
PWR
COLL %
AUI BNC
AUI BNC
KNE16TP/RS
LINK / ACT / PARTITION
1 2 3 4
9 10 11 12
KNE24TP/RS
LINK / ACT / PARTITION
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
5 6 7 8
13 14 15 16
3421
1112109
3421
786511
15161413 19201817
109
21 22 23 24
CABLE TYPE
CASCADE
15161413
12
CABLE TYPE
CASCADE
Models KNE16TP/RS and KNE24TP/RS
KNE24TP/RS User’s Guide - Rev. A01 Kingston Technology Company
2 General Information
Special Features
Stack-n-Play™ ports connect up to five EtheRx hubs as a
single repeater unit
Hot-Stack™ additional hubs without powering down
Smart Monitor
16 or 24 UTP ports for 10BASE-T connections
1 BNC port for 10BASE2 thin Ethernet connection
1 AUI port for backbone or mixed media connection
Cascade switch on last UTP port
UTP Link, Activity, and Partition Status LEDs for easy troubleshooting
BNC Activity and Partition LED
AUI Activity and Partition LED
5 Utilization LEDs to monitor network traffic
5 Collision LEDs to monitor data collision
Automatic partition and reconnection
Internal auto-sensing power supply operating at 110VAC or 240VAC
Complies with IEEE 802.3 and 802.3i Ethernet standards
19-inch rack mountable (mounting kit included)
bar-graph LEDs for network traffic monitoring
Package Contents
Your EtheRx package should contain the following items:
ο KNE16TP/RS or KNE24TP/RS Ethernet Hub ο 5.5” shielded stacking cable
ο AC power cord ο BNC T-connector
ο Mounting kit includes:
(2) Angle brackets (8) Bracket mounting screws (4) 10/32” Rack-mount screws (4) Rubber Feet
ο User's Guide
If any of the items are missing or damaged, please contact your Kingston dealer for a replacement. Be sure the items you receive are genuine Kingston Technology products. If of your unit, it’s not a genuine Kingston product.
the Kingston name and logo are not on the front panel
Kingston Technology Company KNE24TP/RS User’s Guide - Rev. A01
Design Features 3
Design Features
The EtheRx Pro-Series hubs comply with the full set of repeater functions as defined by IEEE802.3 CSMA/CD and IEEE 802.3i 10BASE-T Ethernet standard. These functions include all Repeater Functions, Signal Regeneration, Jabber Lockup Protection, Fragment Extension, Collision-Handling, Auto Partitioning/Reconnection and Link Test. These functions are usually transparent to all network activities and are summarized below.
Repeater Functions
If any single port senses the start of a valid packet on its receiving line, the EtheRx hub will re-transmit the received data to all other ports on the network. The re-transmission of packets complies with the IEEE 802.3 specification in terms of preamble structure, voltage amplitude, and timing characteristics. These timing regenerations prevent cumulative signal loss, jitter, and distortion caused by the network cabling, and allow the EtheRx hubs to be cascaded to other Ethernet hubs.
Jabber Lock-up Protection
The EtheRx hubs implement a built-in jabber protection scheme to ensure that the network is not disabled due to transmission of excessively long data packets. This protection scheme will automatically interrupt the reception of abnormally long streams of data to prevent jabber lock-up.
Fragment Extension
If the total packet length received by the EtheRx hub is less than 96 bits, including preamble, then the hub will automatically extend the repeated packet length to 96 bits by appending a jam sequence to the original fragment. The extension of a fragmented packet allows the reliable detection of a collision by all stations attached to the network.
Collision-Handling
The EtheRx hubs will perform collision detection and respond to collision conditions as defined in the IEEE 802.3 specifications.
KNE24TP/RS User’s Guide - Rev. A01 Kingston Technology Company
Loading...
+ 21 hidden pages