Kingston Technology Kingston Fast EtheRx KNS1650/R, KNS3250/R, KNS2450/R User Manual

KINGSTON TECHNOLOGY FAST ETHERX 16-PORT,
24-PORT & 32-PORT 10/100TX RACK-MOUNTABLE
FAST ETHERNET SWITCH USER’S GUIDE
MODEL(S): KNS1650/R KNS2450/R KNS3250/R
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
i
Kingston Technology’s
Fast EtheRx 16-Port,
24-Port, & 32-Port
10/100BASE-TX
Rack-Mountable
Fast Ethernet Switch
User’s Guide
Part No. 4460186-001.A00
Kingston Technology Company
17600 Newhope
Fountain Valley, CA 92708
(714)435-2600
www.kingston.com
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
ii
Important Safety Instructions
1. Read all these instructions.
2. Save these instructions for later use.
3. Follow all warnings and instructions marked on the product.
4. Do not use this product near water.
5. This product should be operated from the type of power source indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company.
6. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous voltage points or other risk. Refer all servicing to service
personnel.
Wichtige Sicherheitshinweise
1. Diese Hinweise sollten vollständig durchgelesen werden.
2. Diese Hinweise für einen späteren Gebrauch aufbewahren.
3. Allen auf dem Gerät angebrachten Warnungen und Hinweisen folgen.
4. Das Gerät nicht in der Nähe von Wasser verwenden.
5. Das Gerät nur mit dem Aufkleber bezeichneten Netzspannung betreiben. Bei Fragen über die Art der Netzspannung sollte der Händler oder dasEnergieversorgungsunternehmen zu rate
gezogen werden.
6. Nicht versuchen das Produkt selbst zu reparieren. In allen Produkten existieren gefährliche elektrische Spannugen.
Nicht das Gehäuse öffnen.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
iii
TABLE OF CONTENTS
Introduction......................................................................................................1
Special Features .................................................................................2
Package Contents ...............................................................................3
Design Features..................................................................................4
Hardware Installation.......................................................................................6
Front Panel .........................................................................................6
Rear Panel ..........................................................................................7
Software Installation ........................................................................................8
Switch Conguration Utility............................................................................8
Device Conguration Main Screen....................................................8
Device Conguration Properties......................................................11
System ................................................................................11
Port .....................................................................................13
Trunk Assignment ..............................................................15
VLAN.................................................................................19
Explicit Address Table........................................................22
Using the Switch Conguration Utility .........................................................24
Editing a Conguration File.............................................................24
Sending the Current Conguration to the Switch ............................25
Assigning Trunks and Setting VLAN Groups .................................27
Troubleshooting ............................................................................................33
Appendices
Appendix A Pin Assignments...........................................................36
Appendix B Cabling Guidelines ......................................................37
Appendix C Specications...............................................................40
Appendix D Fiber FX Modules and Installation..............................42
Appendix E Mounting Templates ....................................................44
Appendix F Product Warranties and Notices ...................................45
Limited Warranty Statement...............................................45
Duration of Warranty..........................................................45
Free Technical Support.......................................................46
Disclaimers.........................................................................46
F.C.C. Certication.............................................................47
CE Notice ...........................................................................47
C-Tick Certication............................................................47
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
iv
KNS3250/R User’s Guide - Rev. A00 Kingston Technology Company
Introduction 1
Introduction
Intended Audience: This manual assumes that the user has a general working knowledge of networking principles and architecture and is familiar with network systems in general.
Congratulations on the purchase of your new Kingston Fast EtheRx 10/100BASE-TX Rack-Mountable Fast Ethernet Switch. There are three models available, the KNS1650/R, the KNS2450/R and the KNS3250/R, 16-ports, 24-ports and 32-ports, respectively. The Fast EtheRx Switch is a high-performance 10/100BASE-TX switch ideal for the small-to-medium businesses. The Fast EtheRx Switch has sixteen (16), twenty-four (24) or thirty-two (32) UTP ports (depending on model) that auto-negotiate speed detection for 10/100BASE-TX and half-duplex / full-duplex mode operation. The Kingston Fast EtheRx Switch allows standard 10BASE-T Ethernet networks to communicate with 100BASE-TX Fast Ethernet networks and to segment both 10Mbps and 100Mbps networks. The KNS1650/R, KNS2450/R, and KNS3250/R switches also provide additional features such as VLAN, link trunking, broadcast storm control, secure mode trafc ltering and ow control. The Fast EtheRx Switch complies with IEEE802.3u 100BASE-TX, IEEE802.3i 10BASE-T, IEEE 802.3x and IEEE802.3 CSMA/CD Ethernet Standards.
The Fast EtheRx Switch may be used in both standard desktop and 19” rack­mount installations (using the mounting brackets provided with the unit). For easy recognition of network status and troubleshooting, the front panel includes a variety of diagnostic LEDs including Power, 100TX Speed Detection, Link, Receive, Transmit, Collision, and Full-Duplex status.
For the remainder of this manual, the KNS1650/R, KNS2450/R, and KNS3250/R will be referred to collectively as the Fast EtheRx Switch.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
2 Model Types
Model Types
KNS3250/R
LINK / ACT
LINK / ACT
FDX/ COL
POWER
FDX/ COL
Fast EtheRx 10/100TX
32-Port VLAN/TrunkingSwitch
2/FX2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
1/FX1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
100 Mbps 10 Mbps FDX COL
FX Module
2/FX2 4 6 8
1/FX1 3 5 7
10 12 14 16
9 11 13 15
18 20 22 24
17 19 21 23
26 28 30 32
25 27 29 31
2/FX2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24
1/FX1 3 5 7
Fast EtheRx 10/100TX
24-Port VLAN/TrunkingSwitch
KNS2450/R
LINK / ACT
FDX/ COL
POWER
LINK / ACT
FDX/ COL
2/FX2 4 6 8 10 12 14 16 18 20 22 24
1/FX1 3 5 7 9 11 13 15 17 19 21 23
100 Mbps 10 Mbps
FDX COL
FX Module
Fast EtheRx 10/100TX
16-Port VLAN/TrunkingSwitch
KNS1650/R
LINK / ACT
FDX/ COL
POWER
1/FX1 2/FX2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
100 Mbps FDX
LINK / ACT= FDX/ COL =
10 Mbps COL
FX Module
5 6 7 8 9 10 11 12 13 14 15 161/FX1 2/FX2 3 4
Fig.1 - KNS1650/R, KNS2450/R, & KNS3250/R
Special Features
• Provides automatic switching function between 100BASE-TX and 10BASE-T networks.
• Sixteen (16), twenty-four (24), or thirty-two (32) auto-negotiating ports for 10/100Mbps operation.
• Trunking capabilities,
• Supports 16, 24, or 32 port-based VLANs.
• 16, 24, or 32 UTP ports that auto-negotiate 10/100Mbps operation.
• Auto-negotiates full- or half-duplex operation.
• Store-and-Forward switching approach to minimize re-transmission of faulty packets.
• Filtering/Forwarding rate of 148,800 packets per second at 100Mbps.
• Filtering/Forwarding rate of 14,880 packets per second at 10Mbps.
• 1K active address entry table per device with self-learning and table aging.
• 2 MB packet buffer per eight ports.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Package Contents 3
Package Contents
Your Fast EtheRx package should contain the following items:
q One of the following model Fast EtheRx switches:
• KNS1650/R
• KNS2450/R
• KNS3250/R
q AC Power Cord
q Kingston Switch Conguration Utility oppy diskette
q Conguration Cable
q Mounting kit including:
(2) Angle Brackets
(4) Mounting Bracket Screws
(4) 10/32” Rack-Mount thumb screws
(4) Rubber Feet
q User’s Guide
If any of the items are missing or damaged, please contact your Kingston dealer for a replacement. Be sure the items you receive are genuine Kingston Technology products. If the Kingston name and logo are not on the front panel of your unit, it’s not a genuine Kingston product.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
4 Design Features
Design Features
VLAN
VLAN is short for Virtual Local Area Network, and is generally dened as a broadcast domain. It can be viewed as a group of end nodes which can communicate with each other even though they may be located on different physical network segments.
The Fast EtheRx switch provides a simple solution to protect your network against broadcast storming by creating segments based on Layer 2 Ethernet information. As a result, each group of stations connected to a seperate segmented port form an isolated Broadcast Domain. In a switched network environment, a broadcast packet or an unknown destination MAC address packet will broadcast to ALL ports, which can decrease the entire network system performance dramatically. By grouping ports into VLANs, broadcast packets will only be sent to the ports within the same VLAN without effecting the trafc of the ports outside of the VLAN. Broadcast sharing ports can be used to connect servers and other common services, such as Internet access, that are used by all the stations connected to the different segmented ports.
Typically users are grouped according to similar characteristics such as a common business function or a common protocol. A single switch may have several independent VLANs within it.
Link Trunking
Link trunking is basically a method of treating multiple physical links as a single logical link. By grouping ports into a trunk, you can increase the available bandwidth between switches or servers. Multiple lower speed links can be grouped into a single higher speed link. For example, four full-duplex 100Mbps link, such as ports 1 through 4, can be grouped as a single 800Mbps link as Trunk 1.
Switching Function
The Fast EtheRx Switch is basically designed to bridge Standard 10BASE-T Ethernet networks to 100BASE-TX Fast Ethernet networks and to segment
10Mbps or 100Mbps network segments.
Auto-Negotiation
Auto-Negotiation provides the means of automatically establishing a link by detecting the link capabilities of the connected device on the network to select the best operational mode available (i.e. 100BASE-TX/10BASE-T selection, half- /
full-duplex mode operation, etc.)
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Design Features 5
Full-Duplex
Full-Duplex transmission means that dedicated inbound and outbound channels are established for bi-directional transmission of data. This allows the collision detection mechanism (CSMA/CD) to be by-passed, thus decreasing transmission delay normally caused by listening, collisions, and packet resends when operating
in half-duplex mode.
Store-and-Forward Switching
The Fast EtheRx Switch uses a packet-forwarding method called Store-and­Forward, which minimizes the re-transmission of faulty data packets. This means that the Fast EtheRx Switch can store the incoming frame in an internal buffer and check the packet for errors before sending it out to the destination port. If the
frame does contain errors, it will be discarded and then retransmitted.
Flow Control
In half-duplex mode the Fast EtheRx Switch implements a collision-based backpressure ow control mechanism that reduces the risk of data loss at congested ports. This is accomplished by forcing a collision with the data frames on all ports once the free-buffer queue has reached the pre-set minimum.
In full-duplex mode the Fast EtheRx Switch implements the IEEE 802.3x ow control mechanism. This is accomplished by sending a PAUSE packet on a port
when the number of buffers allocated to this port exceeds the pre-set minimum.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
6 Hardware Installation
Hardware Installation
Before you begin installing network cables, please take a few moments to familiarize yourself with Fast EtheRx Switch. The functions on the front and rear
panels are illustrated in the following sections.
Front Panel
KNS3250/R
LINK / ACT
LINK / ACT
FDX/ COL
POWER
FDX/ COL
FastEtheRx 10/100TX
32-PortVLAN/Trunking Switch
2/FX2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
1/FX1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
100 Mbps 10 Mbps FDX COL
FXModule
2/FX2 4 6 8
1/FX1 3 5 7
10 12 14 16
9 11 13 15
18 20 22 24
17 19 21 23
26 28 30 32
25 27 29 31
Power LED
Full Duplex /Collision LEDs
Link /Activity LEDs
Fiber FX Module (Optional)
10/100BASE-TX
UTP Ports
Fig. 2 KNS2450/R Front Panel
Power LED
The PWR LED indicates the power status of the Fast EtheRx Switch. The LED will light up steady green when the AC power cord is connected to the unit from
a power source.
Link / Activity LED
The LINK/ACT LED uses a single LED to display two functions. A steady green light indicates that a good link has been established, and a ashing green light indicates when data is being received or transmitted. If the LED does not display solid green indicating a good link, check the following:
1. Make sure that the power is turned on for both the Fast EtheRx Switch and the attached device.
2. Verify that the drivers for the network adapter have been loaded on the PC. Some network adapters require that the driver be loaded before establishing a proper link.
3. Make sure the cable is wired properly and connected on both ends.
4. Make sure the correct cable type has been selected.
5. If steps 1 through 4 are correct, please check the cable, as it may be defective or wired incorrectly. Replace the cable and try again. Please refer to Appendix A for Pin Assignments and Appendix B for Cabling Guidelines.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Hardware Installation 7
Full Duplex and Collision LED
The FDX/COLL LED uses a single color LED to display two functions. A solid green light indicates that Full-Duplex operation has been detected. A ashing amber light indicates that a collision has occurred in half-duplex mode. Full­Duplex mode is auto-negotiated on all UTP ports.
Fiber FX module port (optional)
The ber FX module port can be used with an optional MT-RJ, ST, or SC ber module. Port 1 & 2 on the switch are associated with this module. If the optional module is used, then port 1 & 2 on the switch can not be used. For more details on the modules and instructions on installing them, please refer to Appendix D - Fiber FX Modules and installation.
10/100TX UTP Ports
The Fast EtheRx Switch has 16, 24, or 32 (depending on model) UTP ports that auto-negotiate both 100BASE-TX and 10BASE-T connections, as well as half- or full-duplex operation.
Rear Panel
100-240VAC 50-60Hz .07A MAX
CONFIGURATION PORT
Configuration Port
AC Power Connector
Fig.3 - Rear Panel
AC Power Connector
The Fast EtheRx Switch uses a 100-240VAC internal power supply. Connect the AC power cord from the back of the unit to an AC electrical outlet.
Conguration Port
The Fast EtheRx Switch can be managed using the Kingston Switch Conguration Utility by connecting the conguration cable from the Conguration Port to the parallel port on the back of your host computer.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
8 Software Installation
Software Installation
The Fast EtheRx Switch has several advanced features which can be congured from a Windows 95, 98, NT or 2000 workstation using the provided conguration cable. The software utility allows for VLAN, link trunking, broadcast storm control, secure mode trafc ltering and ow control conguration. The switch conguration software can only be installed on a Windows 95, 98, NT or 2000 system. To install the software, follow the directions below:
1. Insert the Switch Conguration Utility diskette into the oppy disk drive.
2. Go to the Start menu and select Run.
3. Type in A:\SETUP and click OK.
4. Follow the on-screen prompts to complete the installation process.
Switch Conguration Utility
Upon launch, the Device Conguration main screen contains will appear as shown below.
Device Conguration Main Screen
File
This option brings up the default conguration settings for the currently selected device type.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Kingston Switch Conguration Utility 9
Use this option to open a previously saved conguration le.
Save the current conguration to a switch conguration le.
Save the current conguration with another le name.
Device Type
Choose the type of device that is connected for conguration. There are six types which can be selected, the 16, 24 and 32 port models, with or without the ber option.
Printer Port I/O Address
This option should be used to select the Input /Output Range associated with the printer port on your computer. To nd out what the setting should be follow the procedure below:
1. Go to Start, Settings and select Control Panel.
2. Double click on the System icon.
3. Go to the Device Manager.
4. Open up the Ports (COM & LPT) heading by click on the plus sign next to the heading.
5. Highlight the Printer Port (LPT1) and click on the Properties button.
6. Go to the Resources tab and the Input/Output Range should be displayed. This is the value which needs to be selected in the Switch Conguration Utility.
Use the properties button to begin conguration settings. A window with 5 different conguration tabs will be brought up. After modifying the switch conguration, the settings can be written to the device if desired. Conguration data can also be viewed by selecting this option after selecting Read.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
10 Kingston Switch Conguration Utility
Use this button to save the current conguration data to the device. After a successful write operation, the device automatically resets and initializes the new conguration.
If the write operation fails, check the following:
• Verify the conguration cable is well connected.
• Ensure that the conguration cable is connected directly from the PC to the Switch. If any other devices are connected to the PC’s printer port, please disconnect them before attempting the conguration of the switch.
• Check the host PC to verify that the drivers for the Printer Port (LPT1) are installed correctly.
• Make sure the I/O address selected in the Printer Port I/O Address eld matches the actual setting on the host PC.
Use this button to read the conguration data from the device. If the operation is successful, the current conguration will become _Inside_Device_Conguration.
This button will write the factory default settings to the switch.
Use this button to quit the Switch Conguration Utility.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Kingston Switch Conguration Utility 11
Device Conguration Properties
System
Parameters adjusted in this window will control overall system performance.
SuperMAC
Enable: When a collision occurs, the port on which the collision occurs will perform a more aggressive back off algorithm of up to 3 slots.
Disable: This is the default setting, when a collision occurs, the device will perform the IEEE802.3 standard exponential backoff algorithm.
Aging Control
Enable: By default this option is enabled and set with an aging time of 255 seconds. When enabled, learned MAC addresses are discarded after the aging time has been reached. The aging time can be set between 1 and 510 seconds.
Disable: The Fast EtheRx Switch will retain the learned source MAC addresses for each port.
Only dynamically learned addresses will be aged. No explicit (static) entries will be aged out.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
12 Kingston Switch Conguration Utility
Aging Time
The address-aging timer is built in to the table aging process. The minimum time is 1 second and the maximum is 510 seconds. 255 is the default value, if the number exceeds 255 it must be an even number.
Broadcast Storm Control Threshold
The Broadcast storm control function limits the number of consecutive broadast packets for each port that has Broadcast Storm Control enabled. The broadcast packets are stored in the buffer and sent to the other ports one by one. In the buffer, when the number of stored broadcast packets exceeds the specied threshold, the device will discard the consecutive incoming broadcast packets until the number of stored broadcast packets is below the threshold. The assignable values are 16, 32, 48 and 64 with 64 being the default.
Description
This is basically a comment section for notes by the user. Up to 2048 characters can be written. This description can only be saved and read from the disk le, the information is not stored on the device itself.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Kingston Switch Conguration Utility 13
Port
Individual port parameters are congured from this window. Select the port from the window on the left hand side and then modify the parameters on the right. Use the Apply to Other Ports button to assign the same setting to other ports.
Port Selection
Designates the port to be congured.
Security
Enable: Packets which result in security violations at the designated port will be discarded. Security violations would happen if a packet is received from an unknown source MAC address or a source MAC address learned previously from another port. Once enabled, the device will disable address learning and the aging process for this port. Users should add the MAC address of the workstation connected to this port to the address table if they do not want the packets to be discarded.
Disable: The forwarding decision made about packets received from the port will not involve source MAC address checking. This is the default option.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
14 Kingston Switch Conguration Utility
Address Learning
Enable: This option is enabled by default, which will cause the MAC address of the source of a packet to be learned.
Disable: When disabled, the MAC address of the source of a packet from this port will not be learned.
Broadcast Storm Control
Enable: If the accumulated consecutive broadcast packets in the input buffer of a port is over the threshold specied by the value of the Broadcast Storm Control Threshold on the System Page, new incoming broadcast packets will be discarded until the number has been reduced below the threshold.
Disable: Disabled by default, this option ensures the broadcast packet will not be throttled.
Full Duplex Flow Control
Enable: Enabled by default, this option allows the 802.3x full duplex ow control mechanism.
Disable: When disabled, the 802.3x ow control mechanism is not used in full duplex mode.
Auto-Negotiation
Enable: Enabled by default, this option allows the port to determine the Data Rate and Duplex Mode of the attached device.
Disable: Disabling this option allows the user to specify the Data Rate and Duplex Mode settings manually.
Note: If using the port with the ber (FX) interface, this option is disabled.
Data Rate
The user may specify the data transmission rate for the selected port.
Note: If using the port with the ber (FX) interface, this option is xed at 100Mbps.
Duplex Mode
The user may specify full duplex or half duplex mode for this port.
Apply to Other Ports
When the Apply to Other Ports button is selected, a popup window will appear allowing you to select any other ports that you wish to have the same conguration as the currently selected port.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Kingston Switch Conguration Utility 15
Trunk Assignment
The Kingston KNS1650R, KNS2450R, and KNS3250R switches support link aggregation/trunking. Trunking is a method of grouping multiple physical links as a single logical link. The benet is to be able to group multiple lower speed links into one high speed link for bandwidth aggregation. For instance, four full duplex 100Mbps links, such as port 1-4, could be grouped into one 800Mbps link for Trunk 1. Trunking is most commonly used between the switch and server or between two switches.
See the chart below for the maximum number of trunks per switch:
Switch Model Number of Trunks
KNS1650/R 16 Port Switch Up to 4 Trunks
KNS2450/R 24 Port Switch Up to 6 Trunks
KNS3250/R 32 Port Switch Up to 8 Trunks
Each port based trunk can have between 2-4 trunk ports as members of the trunk. MAC Address based trunks must have 4 trunk ports per trunk.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
16 Kingston Switch Conguration Utility
Load Balancing Method
In a multiple link trunk, the links within a trunk should have an equal amount of trafc in order to achieve maximum efciency. Thus, some sort of load balancing amongst the links of a trunk must be deployed. The Kingston KNS1650/R, 2450/R, and 3250/R switches support MAC address based and port based balancing methods. Using these methods, any packet with a trunk destination received by the switch can be forwarded to a proper trunk port. After choosing one method, the user must specify the relative load-balancing mapping to complete the conguration of the trunk port load balancing.
Trunk Selection, Trunk Port Assignment
Place checkmarks in the boxes of the desired trunk and check the desired trunk port assignments per trunk.
Trunk: A Trunk is a group of Trunk Ports grouped together.
Port Based Trunk: Each Port Based Trunk may have 2, 3, or 4 Trunk Ports.
MAC Address Based Trunk: Each MAC Address Based Trunk must contain 4 Ports.
Trunk Ports: A port assigned to a Trunk. The Trunk Ports are setup in groups of 4 and must be selected based on the groups. For example, Trunk 1 can only contain Trunk Ports 1, 2, 3, or 4.
Load Balancing Mapping - MAC Address Based
When the switch receives a packet with a trunk destination, it will automatically forward the packet to a trunk port based on the source MAC address (SA) and destination MAC address (DA) of the packet. The device uses two bits from SA and DA to map to four trunk ports.
The user can select which two bits should be used for mapping:
[1:0] Uses bit 1 and 0 for mapping.
[3:2] Uses bit 3 and 2 for mapping.
[5:4] Uses bit 5 and 4 for mapping.
[7:6] Uses bit 7 and 6 for mapping.
Each MAC Address contains 6 bytes of data, the last byte is taken from the source MAC address (SA) and the last byte from the destination MAC address (DA). Each byte contains 8 bits of data and the user can determine which two bits of the last byte are used to map the trunk port. See the example on the following page:
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Kingston Switch Conguration Utility 17
Sample source MAC address Sample destination MAC address
00:C0:F0:1C:23:48 00:C0:F0:22:32:51
The byte is in hexadecimal format, the chart below shows the binary value and the bit numbers:
Byte = Bit Data
Bit Number: 7 6 5 4 3 2 1 0
Last byte of source MAC address (SA) 48 0 1 0 0 1 0 0 0
Last byte of destination MAC address (DA) 51 0 1 0 1 0 0 0 1
The mapping rule is described below:
1. The two bits selected by the user for mapping will result in an odd or even value assignment.
Exclusive Or (XOR) Values
Bit 1 Bit 2 Bits Selected Value
0 0 0 XOR 0 = 0 [Even]
0 1 0 XOR 1 = 1 [Odd]
1 0 1 XOR 0 = 1 [Odd]
1 1 1 XOR 1 = 0 [Even]
2. Four combinations of the result are mapped to four trunk ports:
Source Address Destination Address Trunk Port
Odd Odd Trunk Port 1
Odd Even Trunk Port 2
Even Odd Trunk Port 3
Even Even Trunk Port 4
For example, if the user species bit 1 and 0 for mapping and Trunk 2 is assigned, the packets would be sent to the third Trunk Port of Trunk 2 (which would be Port
7).
Last Byte
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
18 Kingston Switch Conguration Utility
Load Balancing Mapping – Port Based
The port-based load balancing method is an explicit port assignment scheme. It requires that all other ports are assigned to a specic link (trunk port) in the trunk. When the switch receives a packet with a trunk destination, it will automatically forward the packet to a trunk port based on the port it came from.
First select a trunk, then click its Port Based button on the right hand side of the screen under Load Balancing Mapping. The Port Based Trunk Port Mapping for Trunk x window will appear as shown below.
Click the radio buttons to map each port to one of the trunk ports. All assignments must be completed before it will allow you to close the window. After that, the status will display ‘ok’ on the right side of the Port Based button. If the status ‘not yet’ is displayed, then the load-balancing mapping has not been completed.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Kingston Switch Conguration Utility 19
VLAN
This window allows users to dene VLAN membership by groups of device ports. Any individual port or trunk can be a member of a VLAN group. A VLAN group is basically a broadcast domain, but any port/trunk is not limited to belonging to only one VLAN group. The forwarding rule is that packets from the source port/trunk will only be forwarded to a destination port/trunk within the same VLAN group. That is, a broadcast/multicast packet will be forwarded to all ports/trunks within the same VLAN group(s) of the source port/trunk except the source port/trunk itself. Unicast packets will be forwarded to the destination port/trunk only if the destination port/trunk is in the same VLAN group as the source port/trunk.
Flood Control
Within a VLAN, the ood control function is provided to decide what to do with incoming unicast packets with unknown destination MAC addresses.
Enable: Packets received with an unknown unicast destination address (DA) will be forwarded to the specied out-link in the same VLAN group. But if the source port (trunk) belongs to more than one VLAN group, then the packet will only be forwarded to one of the out­ links.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
20 Kingston Switch Conguration Utility
Disable: This option is selected by default. Packets received with an unknown unicast destination address (DA) will be forwarded to all ports (except the receiving port) within the same VLAN groups that the received port (trunk) belongs to.
Flood control is available only when at least one VLAN group is assigned. And the out-link port must be assigned when ood control is enabled for proper operation.
When ood control is enabled, each VLAN group must choose a member as its out-link. If some VLAN groups have overlapped members, one of these members should be chosen as the out-link. If a port (or trunk) belongs to more than one VLAN group, packets that it receives with an unknown destination address (DA) will only be forwarded to one of the out-links of those VLAN groups that it belongs to.
VLAN Group
The list box shows all dened VLAN groups of the system, and each row is a group. Any individual port or trunk can be a member of a VLAN group, and each group comprises at least two members. One of the members is to be chosen as its out-link. If ood control is disabled, the Out-link column will not appear.
To remove the current highlighted group, press the Delete button. Press the Add button to add a new group. To modify settings, select the Modify button or double click the current highlighted group to modify its content. While adding or modifying a VLAN group, the dialog Modify the VLAN Group (or Add a New VLAN Group) as below will popup for user to specify its content.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Kingston Switch Conguration Utility 21
The group count is not limited. Users can specify n VLAN groups or even more groups for any n (n=number of ports on your switch) port switch. But note that after writing to the device, only the information of the rst n/2 added VLAN groups can be read back from the device of n port switch.
Note: Once at least one VLAN group has been added, the system will automatically gather all un-selected members as an implicit VLAN group. Users are recommended to explicitly assign all groups they need, although they know that there exists an implicit VLAN group.
Group Name: Create a group name up to 8 characters long.
Individual Port / Trunk: Both individual ports and trunks can be the members of
a VLAN group. All light checkboxes are qualied members of a VLAN. At least two members must be selected to create a VLAN group.
Out-link Selection: If ood control is enabled, one port or trunk should be chosen as the out-link of this VLAN group. Click on the button to the right of ‘Out-Link Selection’ to bring up the popup window.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
22 Kingston Switch Conguration Utility
Explicit Address Table Page
The address table of the switch uses address learning (dynamic) or manual entry (static). Static entries are added to the address table of the device in this window. Static address entries are not aged or updated by the switch’s address learning.
Explicit Address Table
The list box displays all explicit (static) entries for the address table. Each row is an entry for a MAC address to an individual port or a trunk. There are a total of 10 static addresses that can be assigned to Port 1 – 8, Port 9-16, Port 17 – 24, and Port 25 – 32 group, respectively.
Pressing the Delete button will remove the entry which is currently highlighted, or press the Add button to add a new entry.
Note: Normally, the device has a static entry capacity of 10 per each group. Each group consists of 8 consecutive ports and 2 trunks, that is, Port 1-8 and Trunk 1-2 belong to a group, Port 9-16 and Trunk 3-4 belong to another group, ...etc. However, if a static address is assigned for Trunk 3-8, it will occupy an entry for all groups, not just the group it belongs to. That is, if there is any static address assigned for Trunk 3-8, it will reduce the entry capacity of each group. In the Add a new entry of Explicit Address Table window, ports and trunks are grayed out when there is no capacity to place a static entry for them.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Kingston Switch Conguration Utility 23
In this window, input the MAC address of a workstation, and choose an individual port or a trunk to which the workstation is connected.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
24 Kingston Switch Conguration Utility
Using the Switch Conguration Utility
Editing a Conguration File
1. Go to the Start menu, highlight Programs, Kingston Switch Conguration, and click on the Switch Conguration item.
2. In the main window, choose the switch model from the Device Type pulldown menu.
3. Select the I/O address used by the printer port of the host computer attached to the switch from the Printer Port I/O Address pulldown menu.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Kingston Switch Conguration Utility 25
4. Click the button Open to open an existing conguration le, if necessary.
5. Click the button Properties to invoke the Properties Window to start or modify conguration settings.
6. Click OK to leave this window, if nished these settings.
7. Click the button Save or Save As to save current settings as a conguration disk le.
Sending the Current Conguration to the Switch
1. Connect the Conguration Cable directly to the printer port of your host PC and to the Conguration Port on the switch.
2. Power on the switch.
3. Go to the Start menu, highlight Programs, Kingston Switch Conguration, and click on the Switch Conguration item.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
26 Kingston Switch Conguration Utility
4. In the main window, choose the switch model from the Device Type pulldown menu.
5. Select the I/O address used by the printer port of the host computer attached to the switch from the Printer Port I/O Address pulldown menu.
6. Click the Open button to open an existing conguration le if necessary.
7. Click the Write button to write the current conguration data to the switch via the conguration cable.
8. If the data is written successfully, the switch will be auto reset immediately and the current conguration will be initialized.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Kingston Switch Conguration Utility 27
Assigning Trunks and Setting VLAN Groups
Fast EtheRx 10/100TX
24-Port VLAN/Trunking Switch
KNS2450/R
LINK / ACT
FDX / COL
POWER
LINK / ACT
FDX / COL
2/FX2 4 6 8 10 12 14 16 18 20 22 24
1/FX1 3 5 7 9 11 13 15 17 19 21 23
2/FX2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24
1/FX1 3 5 7
100Mbps 10Mbps
FDX COL
FX Module
Fig. 4 - VLAN example
Here we give an example to show how to assign trunks and set VLAN groups. From the gure above, the user plans to congure a 24 port switch into two VLAN groups, one for Engineering and the other for Sales/Marketing. There are four stations connected to Port 5 to Port 8 respectively used by engineers, and a server shared by them which is connected to Trunk 1 by using four trunk ports. On the other side, there are three stations connected to Port 9 to Port 11 respectively used by Sales/Marketing department, and a server shared by them which is connected to Trunk 6 by using two trunk ports.
To achieve the goal above, just follow steps below:
1. Click the Properties button to open the Properties window.
VLAN #1:
Engineering
VLAN #2:
Sales/Marketing
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
28 Kingston Switch Conguration Utility
2. Select the Trunk Assignment tab to begin assigning trunks.
3. Click the checkboxes to select Trunk 1 and Trunk 6, and assign their trunk ports. Click the relative Port Based buttons 1 and 6 to begin port-based trunk port mapping.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Kingston Switch Conguration Utility 29
4. Click the radio boxes to assign trunk port mappings for Trunk 1. For Ports 5 to 24, map them to different trunk ports.
5. Click the radio boxes to assign trunk port mappings for Trunk 6. From Ports 1 to 22, map them to both trunk ports evenly.
6. After completing the trunk port mappings, OK should appear beside the relative Port Based buttons. Now, all trunk assignments are nished. Click the VLAN page to start VLAN settings.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
30 Kingston Switch Conguration Utility
7. Press the Add button to add a VLAN group.
8. Give the name ‘Engineer’ in the edit box and select Trunk 1 and Ports 5 through 8 to be members of this group.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Kingston Switch Conguration Utility 31
9. Press Add button to add another VLAN group.
10. Type in ‘SalesMkt’ in the edit box and select Trunk 6, click Ports 9 through 11 to be members of this group.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
32 Kingston Switch Conguration Utility
11. Two VLAN groups have been created, click OK to leave the Properties Window.
12. To retain the settings after powering off the unit, click the Save button to save current conguration as a le, and press the Write button to save the settings to the device itself.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Troubleshooting 33
Troubleshooting
Data cannot be read from or written to the device.
1. Make sure the switch is powered on.
2. Make sure the Conguration Cable is well connected. It should be connected to the PC’s printer port directly. If there is any device, such as key-pro or printer buffer attached on the printer port, please remove it before connecting the Conguration Cable.
3. On the host PC verify that the drivers for Printer Port (LPT) are installed correctly. Go to the Start menu, highlight settings, and select Control Panel. Double click the system icon and go to the Device Manager tab. Make sure Printer Port exists under the submenu Ports (Com & LPT). If it does not exist, the LPT drivers need to be installed. If it exists, check the properties. Go to the Resource tab and check to make sure the Input/Output Range is 0378-037F, 0278-027F, or 03BC-03BF
4. Check the Parallel Port Mode in the host PC’s BIOS settings, if it is SPP, please change it into EPP or ECP mode.
5. Make sure the correct Printer Port I/O Address is selected in the Switch Conguration Utility’s main menu.
6. Verify that the correct Device Type is selected in the Switch Conguration Utility.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
34
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Appendices 35
Appendices
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
36 Appendix A - Pin Assignments
Appendix A Pin Assignments
UTP Port Pin Assignments
UTP Ports use RJ-45 Unshielded Twisted Pair (UTP) cabling. RJ-45 modular plugs and their pin numbers and wiring assignments are listed below. Twisted­Pair cables can be wired with either Straight-Through or Crossover pin assign­ments. Both wiring schemes are mentioned in “Appendix B Cabling Guidelines” for reference in creating a twisted-pair cable.
Fig. A-1 RJ-45 Connector Pin Numbers
Table A-1 UTP Pin Assignments
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Appendix B - Cabling Guidelines 37
Appendix B Cabling Guidelines
UTP Cable Type
When installing network cables, the following table shows appropriate cabling guidelines for 100BASE-TX Fast Ethernet architecture.
Table B-1 Network Cable Guidelines
(NOTE: All UTP cables come in both solid and stranded lament. Solid lament cables are more rigid and usually intended for trunk cabling. Stranded lament cables are more pliable and generally targeted for patch cables. For proper termination, use the correct RJ-45 connector, as they differ for each type of cable.)
UTP Cable Wiring
UTP cables are wired based on one of two standard pin congurations: Straight­Through and Cross-Over. 100BASE-TX uses only Category-5 UTP cables with
four pairs of wire as illustrated below in Tables B-2 and B-3.
Straight-Through Cross-Over Conguration Conguration
Table B-2 Straight-Through Wiring Table B-3 Cross-Over Wiring
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
38 Appendix B - Cabling Guidelines
UTP Cable Wiring Standards
There are two governmental agencies: the Electronic Industry Association (EIA) and the Telecommunications Industry Association (TIA), which set the standard for all cable wiring requirements for commercial buildings.
With the advent of 100Mb/s networking products, it is best to use higher quality CAT 5 cables like Belden or Helix as well as CAT 5-compliant patch panels, patch cables, and connectors while following the EIA/TIA wiring standards. 100 W UTP CAT 5 type cables use 4-pair UTP wiring.
Refer to the illustrations below for 4-pair wiring using either T568A (Fig. B-1) or T568B (Fig. B-2) wiring standards. Both T568A and T568B wiring is compatible with 10BASE-T and 100BASE-TX and require no special congurations, but for premise wiring, stick to one wiring standard. Mixing T568A and T568B wiring schemes may cause or lead to potential problems.
Fig. B-1 4-Pair T568A Wiring Fig. B-2 4-Pair T568B Wiring
Table B-4 4-Pair T568A Wiring Table B-5 4-Pair T568B Wiring
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8
Pair 3 Pair 3 Pair 2 Pair 1 Pair 1 Pair 2 Pair 4 Pair 4
Blue
Orange
Black
Red Green Yellow Brown
White
White/Green Green/White White/Orange Blue/White White/Blue Orange/White White/Brown Brown/White
T568A Pairs Strand Solid
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8
Pair 2 Pair 2 Pair 3 Pair 1 Pair 1 Pair 3 Pair 4 Pair 4
Black
Yellow
Blue
Red Green
Orange
Brown
White
White/Orange Orange/White White/Green Blue/White White/Blue Green/White White/Brown Brown/White
T568B Pairs Strand Solid
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Appendix B - Cabling Guidelines 39
UTP Cable Rating Codes
UTP cables meet different UL-NEC requirements based on cable-jacket quality. Below is an explanation of the rating codes for each cable type.
UL – The National Electrical Code (NEC), published by the National Fire Protection Association (NFPA), details advisory safety considerations for electrical wiring. NEC Article 800 Communications Cables are manufactured to meet these different cable types.
1. CMP – Cables meeting type CMP requirements are suitable for installation in ducts and plenums without the use of conduit. These cables are designed for re resistance and low-smoke producing characteristics.
2. CMR – Riser type cables are engineered to prevent the spread of re from oor to oor and are suitable for vertical shaft applications.
3. CM – Cables for general building wiring. CM cables are used in areas other than plenums and risers. These cables are resistant to the spread of re and pass the UL 1581Vertical Tray Flame Test.
4. MP, MPR & MPP – Within Article 800, the Multi-purpose Cables Category allows conditional substitutions between different cable types & are restricted by number, AWG size and stranding of the cable conductors.
Terms You Should Be Familiar With
1. BACKBONE WIRING – The physical/electrical interconnections between telecommunications closets and equipment rooms.
2. COMPLIANCE – A wiring device that meets all characteristics of a standard is said to be in compliance with that standard.
3. PREMISE WIRING – The entire wiring system on the premises especially the supporting wiring that connects the communications outlets to the network interface jack.
4. NEAR-END CROSSTALK (NEXT) – In wires packed together within a cable, the signals generated at one end of the link can ush out the weaker signals coming back from the recipient.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
40 Appendix C - Specications
Appendix C - Specications
Compliance: IEEE 802.3i 10BASE-T Standard IEEE 802.3u 100BASE-TX Standard IEEE 802.3 CSMA/CD Ethernet Standard
Media Interface: KNS1650/R 16 auto negotiating 10/100 Mbps UTP ports KNS2450/R 24 auto negotiating 10/100 Mbps UTP ports KNS3250/R 32 auto negotiating 10/100 Mbps UTP ports
10BASE-T / 100BASE-TX: Auto-Negotiation
Half / Full-duplex mode: Auto-Negotiation
Diagnostic LEDs: 1 LED for Power indicator (steady green)
KNS1650/R 16 LEDs for Link/Activity detection Link = steady green 100 Mbps activity = ashing green 10 Mbps activity = ashing amber
16 LEDs for Full Duplex/Collision detection Full Duplex = steady green Collision = ashing amber
KNS2450/R 24 LEDs for Link/Activity detection Link = steady green 100 Mbps activity = ashing green 10 Mbps activity = ashing amber
24 LEDs for Full Duplex/Collision detection Full Duplex = steady green Collision = ashing amber
KNS3250/R 32 LEDs for Link/Activity detection Link = steady green 100 Mbps activity = ashing green 10 Mbps activity = ashing amber
32 LEDs for Full Duplex/Collision detection Full Duplex = steady green Collision = ashing amber
Switching Approach: Store-and-Forward
Flow Control: Half-duplex – Collision-based Backpressure Full-duplex – IEEE 802.3x
MAC Address Support: 1K MAC addresses
Filtering/Forwarding Rate (min. packet size): 100BASE-TX 148,800 packets/second 10BASE-T 14,880 packets/second
Latency (min. packet size): KNS1650/R 100BASE-TX 100 Mbps to 100 Mbps 11.6 ms 10BASE-T 10 Mbps to 10 Mbps 70.5 ms
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Appendix C - Specications 41
KNS2450/R 100BASE-TX 100 Mbps to 100 Mbps 13.6 ms 10BASE-T 10 Mbps to 10 Mbps 76.6 ms
KNS3250/R 100BASE-TX 100 Mbps to 100 Mbps 17.8 ms 10BASE-T 10 Mbps to 10 Mbps 76.9 ms
Max. Segment Length: 100 meters (328 feet)
Connector Type: Female RJ45
Cable Type: UTP 26 to 22 AWG
Cable Grade: 100BASE-TX CAT 5 or better 10BASE-T CAT 3, 4, 5 or better
Optional Fiber Support: MTRJ Interface 2-port FX module ST Interface 1-port FX module SC Interface 1-port FX module
Parallel Conguration Port: Supports VLAN & Trunking switch congurations
Environmental:
Operating Temperature: 0ºC to 45ºC (32ºF to 113ºF) Storage Temperature: -20ºC to 60ºC (-4ºF to 140ºF) Relative Humidity: 10% to 90% non-condensing
Electrical:
Input AC Voltage: 100VAC to 240VAC, 50/60 Hz, Auto-sensing Output DC Voltage: 3.3VDC/6A and 5.0VDC/0.5A
Power Consumption: KNS1650/R 14 Watts max.
KNS2450/R 16 Watts max.
KNS3250/R 18 Watts max.
Physical:
Dimension (HxWxD): 1.69” x 17.32” x 7.88” (43.3 mm x 443.4 mm x 201.7 mm) Weight:
KNS1650/R 5.5 lbs. (2.5 kg)
KNS2450/R 5.8 lbs. (2.6 kg)
KNS3250/R 6.0 lbs. (2.7 kg)
Certication:
EMI Standards: FCC Class A, CE CISPR A, C-Tick EMC Standards: EN55022, IEC801-2. IEC801-3, IEC801-4 Low Voltage Directive: EN60950 Safety Standards: UL, cUL, TUV
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
42 Appendix D - Fiber FX Modules & Installation
Appendix D Fiber FX Modules & Installation
There are three different optional ber modules available for use with your Fast EtheRx Switch.
KNS150FX/MTRJ
The KNS150FX/MTRJ module
KNS150FX/SC
The KNS150FX/SC module
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Appendix D - Fiber FX Modules & Installation 43
KNS150FX/ST
The KNS150FX/ST module
Installing the ber module
1. Remove the screws holding the metal plate cover located over the Fiber FX Module Port and remove the metal plate cover.
2. Carefully slide the KNS150FX module into the Fiber FX Module Port as shown below.
K
N
S
3
2
5
0
/
R
L
I
N
K
/
A
C
T
L
I
N
K
/
A
C
T
F
D
X
/
C
O
L
P
O
W
E
R
F
D
X
/
C
O
L
F
a
s
t
E
t
h
e
R
x
1
0
/
1
0
0
T
X
3
2
-
P
o
r
t
V
L
A
N
/
T
r
u
n
k
i
n
g
S
w
i
t
c
h
2
/
F
X
2
4 6
8
1
0
1
2
1
4
1
6
1
8
2
0
2
2 2
4
2
6
2
8
3
0
3
2
1
/
F
X
1
3 5
7 9
1
1
1
3
1
5
1
7
1
9
2
1 2
3
2
5
2
7
2
9
3
1
100
M
bps
10 Mbps
FD
X
CO
L
F
X
M
o
d
u
l
e
2/FX
2
4
1/FX
1 3
3. Tighten both screws to secure the KNS150FX module within the Fast EtheRx Switch.
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
44 Appendix E - Mounting Templates
Appendix E Mounting Templates
The Fast EtheRx dual-speed hubs can be stationed on a at surface using the four rubber feet provided, or mounted in a standard 19” rack by using the mounting
brackets and thumb screws provided with the unit.
Rubber Feet for Desktops
The Fast EtheRx dual-speed hubs come with rubber feet that may be applied to the bottom of the unit for desktop surface installations. The 4 rubber feet have peel­off adhesive backing. Remove the backing and attach the feet to the bottom of the
switch.
Brackets for Rack Mounting
The Fast EtheRx dual-speed hubs can also be mounted in a standard 19” rack using the brackets included with the unit. A rack mount installation uses a standard 19” dimension. Align the holes in the brackets with the holes on each side of the unit. Use the screws provided to secure the brackets to the Fast EtheRx dual-speed hub. See Figure E-1 below:
Fig. E-1 Attaching the Mounting Brackets
Important Note: Although the bracket has four holes, only 2 holes are used.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Appendix F - Warranties & Notices 45
Appendix F Warranties and Notices
Limited Warranty Statement
KINGSTON TECHNOLOGY COMPANY (“Kingston”) warrants that this product is free from defects in material and workmanship. Subject to the conditions and limitations set forth below, Kingston will, at its option, either repair or replace any part of this product which proves defective by reason of improper workmanship or materials. Repair parts or replacement products will be provided by Kingston on an exchange basis, and will either be new or refurbished to be functionally equivalent to new.
This warranty does not cover any damage to this product that results from accident, abuse, misuse, natural or personal disaster, or any unauthorized disassembly, repair or modication.
Duration of Warranty
Lifetime Warranty: The following Kingston products are covered by this warranty for life: memory modules and expansion boards, networking adapters, networking hubs without cooling fans (excluding the power supply), and microprocessor upgrade products.
Seven Year Warranty: The following Kingston products are covered by this warranty for a period of seven years from the date of original retail purchase: all core storage enclosures (including the power supply), cables, terminators, and related accessories. Under certain agreements where core products are slightly modied (e.g. paint, handle, etc.) by Kingston at the customer’s request, the product will be covered for a period of seven years for repair only. Storage products that are custom designed and /or incorporate component-level modication by Kingston in order to meet specic customer requests, will be negotiated with the applicable customer on a per case basis.
Five Year Warranty: The following Kingston products are covered by this warranty for a period of ve years from the date of original retail purchase: the power supply in networking hubs without cooling fans; Flash memory cards (e.g. CompactFlash, ATA Flash, and Linear Flash); solid state PC Card (PCMCIA) adapters, PC Card Readers and all other Kingston products (other than those products covered by a three-year, two-year, or one-year warranty, as provided below).
Three Year Warranty: The following Kingston products are covered by this warranty for a period of three years from the date of original retail purchase: networking hubs with cooling fans (including the power supply).
Two Year Warranty: The following Kingston products are covered by this warranty for a period of two years from the date of original retail purchase: Solid State Floppy Disk Cards (SSFDC), and Winchester hard disk drives in a 2.5 inch, 3.5 inch or 5.25 inch form factor.
One Year Warranty: The following Kingston products are covered by this warranty for a period of one year from the date of original retail purchase: Winchester hard disk drives in a 1.8 inch form factor, optical storage products, and magnetic tape storage products. Rev. 3/99
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
46 Appendix F - Warranties & Notices
Warranty Claim Requirements
To obtain warranty service, return the defective product, freight prepaid and insured, to your local authorized Kingston dealer or distributor, or to the Kingston factory service center located at 17600 Newhope Street, Fountain Valley, California 92708, U.S.A. You must include the product serial number (if applicable) and a detailed description of the problem you are experiencing. You must also include proof of the date of original retail purchase as evidence that the product is within the applicable warranty period. If you return the product directly to the Kingston factory, you must rst obtain a Return Material Authorization (“RMA”) number by calling Kingston Customer Service at (714) 438-1810, and include the RMA number prominently displayed on the outside of your package. Products must be properly packaged to prevent damage in transit.
Free Technical Support
Kingston provides free technical support. If you experience any difculty during the installation or subsequent use of a Kingston product, please contact Kingston’s Technical Support department prior to servicing your system.
Kingston Technical Support can be reached in the U.S. at (714) 435-2639 or toll­free at (800) 435-0640 (U.S. and Canada only). Kingston European Technical Support can be reached from within Europe at 00800 8888 0101 or by fax at 00800 8823 8823.
This warranty covers only repair or replacement of defective Kingston products, as provided above. Kingston is not liable for, and does not cover under warranty, any costs associated with servicing and/or the installation of Kingston products.
Disclaimers
The foregoing is the complete warranty for Kingston products and supersedes all other warranties and representations, whether oral or written. Except as expressly set forth above, no other warranties are made with respect to Kingston products and Kingston expressly disclaims all warranties not stated herein, including, to the extent permitted by applicable law, any implied warranty of merchantability or tness for a particular purpose. In no event will Kingston be liable to the purchaser, or to any user of the Kingston product, for any damages, expenses, lost revenues, lost savings, lost prots, or any other incidental or consequential damages arising from the purchase, use or inability to use the Kingston product, even if Kingston has been advised of the possibility of such damages.
Rev. 3/99
Copyright © 2000 Kingston Technology Company. All rights reserved. Printed in Taiwan. Kingston Technology and the Kingston logo are trademarks of Kingston Technology Company. All other logos and trademarks are properties of their respective companies.
KNS3250/R Users Guide - Rev. A00 Kingston Technology Company
Appendix F - Warranties & Notices 47
F.C.C. Certication
This device has been tested and found to comply with limits for Class A digital device, pursuant to Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received; including interference that may cause undesired operation.
CE Notice
The ofcial CE symbol indicates compliance of this Kingston Technology product to the EMC directive of the European Community. The CE symbol indicates that this Kingston product meets or exceeds the following standards:
q EN50081-1 “Electromagnetic Compatibility-generic emissions standard”
EN55022: “Limits and methods of measurement of radio interference characteristics.”
q EN50082-1 “Electromagnetic Compatibility-generic immunity standard”
IEC 801-2: “Electrostatic discharge requirements”
IEC 801-3: “Radiated immunity requirements”
IEC 801-4: “Electrical fast transient requirements”
q EN60950 “Low Voltage Directive (LVD)”
q Declaration of CE Conformity in accordance with the above standards has
been made and is on le at Kingston Technology.
C-Tick Certication
q AS/NZS 3548 “Information Technology Equipment”
q Declaration of C-Tick Conformity in accordance with the above standards
has been made and is on le at Kingston Technology.
N1298