Kingsman ZDV3624, ZDV3628, ZDV3632, ZDV3624B Installation Instructions Manual

Installation Instructions
Listed Certified for USA. and Canada
The ZDV3624NB, ZDV3624LPB, ZDV3628N, ZDV3628LP, ZDV3632N, ZDV3632LP
Model Numbers ZDV3624, ZDV3624B, ZDV3628, ZDV3632
Stock #’s: ZDV3624N, ZDV3624LP
are Certified to: ANSI Z21.50a-2000, CSA 2.22a-2000,
CGA 2.17-M91
, CSA P.4.1-02
are Certified to: ANSI Z21.88b-2003, CSA-2.33b-2003, CGA 2.17-M91, CSA P.4.1-02
KINGSMAN INDUSTRIES
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962
Printed in Canada 22/12/04 Part # 3600-MAN
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
FOR YOUR SAFETY
Warning: Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Refer to this manual. Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
What
To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbour’s phone.
If you can not reach your gas supplier, call the fire department.
WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
“Zero Clearance”
Direct Vent Gas Fireplace
2
Why does my fireplace or stove give off odour?
It is normal for your fireplace to give off some odour. This is due to the curing of the paint, adhesives, silicones and any undetected oil from the manufacturing process as well as the finishing materials used with the installations (e.g. marble, tile and the adhesives used to adhere this product to the walls can react with heat and cause odours).
It is recommended that you burn your gas fireplace or stove for a minimum of four hours at a time with the fan off after the curing of the paint has been completed. These odours can last upward to 40 hours of burn time, keep burning at a minimum of four hours per use until odours dissipate.
About curing of the paint
Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature sili­cone components, the paint will cure when heat is applied to the appliance as it is first used. The following information applies to the curing process to get the paint fully hard and durable.
Fire the appliance four successive times for 10 minutes each firing and a 5 minute cool down between each. Be aware during log and firebox paint curing that a white deposit may be developing on the inside of the glass doors. It is important to remove this white deposit from the glass doors with an appropriate cleaner to prevent build-up (such as Windex or a commercial fireplace glass cleaner).
• Babies, small children, pregnant women and pets should leave the area during the cure phase.
• Ventilate well, open doors and windows.
• Do not touch during curing.
Noise coming from the fireplace?
• Noise caused by metal expanding and contracting as it heats up and cools down, similar to the sound produced by a furnace or heating duct. This noise does not affect the operation or longevi­ty of your fireplace.
PRE-INSTALLATION QUESTIONS and ANSWERS
Mobile Home/Manufactured Housing Installation . . . . . . . .4
Installation and operation . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Locating your appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Framing your gas fireplace . . . . . . . . . . . . . . . . . . . . . . . . .7,8
Mantels and Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Gas Line Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
General glass information . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Log Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Log Placement Guides . . . . . . . . . . . . . . . . . . . . . . . . . . .11-21
Fan kit installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Millivolt system, lighting, & burner control . . . . . . . . . . . . .23
Vent termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Venting graph . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
General vent installation information . . . . . . . . . . . . . . . . . .26
Installation of side wall venting . . . . . . . . . . . . . . . . . . . . . .26
Venting vertical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Back Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Repair parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Valve System Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Kingsman Fireplace part numbers &
specifications Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Kingsman Fireplace accessories . . . . . . . . . . . . . . . . . . . . . .31
Kingsman Fireplace options . . . . . . . . . . . . . . . . . . . . . . . . .31
Trouble shooting the gas control system . . . . . . . . . . . . . . . .32
Kingsman Industries Gas Fireplace – Limited Warranty . . .33
Table of Contents
4
Mobile Home/Manufactured Housing Installation
This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
THE ZDV3624NB, ZDV3624LPB, ZDV3628N, ZDV3628LP, ZDV3632N and ZDV3632LP MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE IN THE USA. IN CANADA THE ZDV3628N, ZDV3628LP, ZDV3632N AND ZDV3632LP MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES.
Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada.
An appliance must be grounded to the steel chassis of the home with 8 ga. copper wire using a serrated or star washer to penetrate paint or protective coating to insure grounding.
Use carriage bolt at the attachment point (see diagram above) to secure the appliance to the floor.
Warning: Do not compromise the structural integrity of the manufactured home wall, floor or ceiling, during installation of appliance or venting.
For required venting components see venting installation in appropriate section of this manual.
Certified for installation in a bedroom or bedsitting room. In Canada must be installed with listed milli volt thermostat. In USA see local codes.
APPLIANCE MUST BE SECURED TO STRUCTURE USING SUPPLIED NAIL TABS AND OR FASTEN TO FLOOR
USE EXISTING HOLE OR REMOVE EXISTING SCREW TO MOUNT GROUND WIRE
(FAN MOUNT HOLE OR OUTER WRAP SCREW)
GROUND WIRE FROM APPLIANCE TO STEEL CHASSIS OF MOBILE HOME. USE 8 GA COPPER WIRE.
SERRATED OR STAR WASHER
5
Installation and Operation
Installation Regulations
This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CGA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1 when installed in the United States.
This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the national Electrical Code; ANSI/NFPA 70-1987 when installed in the United States.
FOR SAFE INSTALLATION AND OPERATION OF YOUR GAS FIREPLACE PLEASE NOTE THE FOLLOWING:
1. This appliance gives off high temperatures and should be located out of heavy traffic areas and away from furniture and draperies.
2. Children and adults should be alerted to the hazards of the high surface temperatures of this appliance and should stay away to avoid burns or ignition of clothing.
3. Children should be carefully supervised when they are in the same room as your fireplace appliance.
4. Under no circumstances should this appliance be modified. Any parts that have to be removed for servicing should be replaced prior to operating this appliance.
5. Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More
frequent cleaning may be required due to excessive lint from carpeting, bedding material, et cetera. It is imperative that control compartments, burners and circulating air pas­sageways of the appliance be kept clean.
6. Control compartments, burners and air passages in this appliance should be kept clean and free of dust and lint. Make sure that the gas valve and pilot light are turned off before you attempt to clean this unit.
7. The venting system (chimney) of this appliance should be inspected at least once a year and if needed, your venting system should be cleaned.
8. Clothing or other flammable material should not be placed
on or near the appliance.
This appliance should not be used as a drying rack for clothing nor should Christmas stockings or decorations be hung from it.
9. Under no circumstances should any solid fuels (wood, paper) be used in this appliance.
10. For safe operation, glass doors must be closed.
11. Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.
12. WARNING: Do not operate appliance with the glass front
removed, cracked or broken. Replacement of glass should be done by a licenced or qualified service person.
13. Do not operate appliance unless completely installed as per installation instructions.
This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CGA ­B149 (.1 or .2) installation codes for Gas Burning Appliances and Equipment.
Never use your gas fireplace as a cooking device.
The Burner/Log Assembly has been engineered and permanently adjusted for proper flame control.
Periodically remove the logs from the grate assembly and vacuum any loose particles from the grate and burner areas.
See log Placement on Pages 11-20 to remove logs, vacuum burner parts and replace logs.
Note: It is normal for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process.
Please ensure that your room is well ventilated - open all windows.
It is recommended that you burn your gas fireplace for at least four (4) hours the first time you use it without the fan on.
Make adequate accessibility clearances for servicing and proper operation.
This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance.
Be sure that the flow of combustion and ventilation air is not obstructed.
Warning: When purging the gas line, the glass front must be removed.
Do not alter gas orifice.
Vertical Venting in Cold Climates
In cold climate conditions where temperatures go below -10 degrees Celsius or 14 degrees Fahrenheit, we recommend that the chase be insu­lated and where the vent pipe enters into the attic space that the pipe be wrapped with an insulated mylar sleeve. This will increase the tempera­ture of the vent and help the appliance to vent properly in cold weather conditions.
It is also important in vertical vented direct vent appliances that the appli­ance be operated daily during the winter months as this will help stop the Termination from freezing up. We recommend using a thermostat set at room temperature to allow the unit to cycle.
6
Locating your Appliance
(above or below grade)
Installing with Top Vent
(above grade)
Installing with Back Vent
Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet (6.1 m). When you install your fireplace as in position ‘B’, ‘D’ or ‘E’, a minimum of 6 inches (153mm) clearance must be maintained from the perpendicular wall and the front of the appliance.
A - Flat on a wall D - As a room divider B - Across the corner E - Flat on wall corner C - As an island F - Exterior wall
7"
4"
16
3
4"
16
1
4"
6"
3329⁄32"
16
3
4"
Top Vent Back Vent
339⁄
32"
36"
3329⁄32"
171⁄16"
231⁄2"
301⁄4"
18”
237⁄16"
163⁄8"
181⁄8"
ZDV3624B
7
Framing for your Gas Fireplace
42"
MINIMUM
34"
17"
33"
Framing Specifications
1. Cold climate installation recommendation: When installing this fireplace against non insulated exterior wall or chase, it is recommended that the outer walls be insulated to conform to applicable insulation codes. Drywall should be installed over insulation to prevent contact of insulation and unit.
2. Choose fireplace location and frame in accordance with the fireplace framing dimensions specified (See Framing Diagrams). Bend nailing tabs forward on left and right of unit and place fireplace into framed enclosure. This allows for 1/2” in front of framing tabs for finishing materials.
3. Drywall or other material can extend flush with the appliance on the bottom, sides and top of fireplace.
4. When installing horizontal with a 90 degree bend maintain a minimum of two and a half (2.5”) inches above the bend in enclosures.
5. Hearth is not mandatory but is recommended for aesthetic purposes. Combustible floors cannot raise above the bottom of the fireplace.
We recommend a non-combustible hearth projecting out 12” (305mm) or more in front of the fireplace.
34"
363⁄8"
17"
821⁄32" DIA. 11"
34"
17"
275⁄8"
MINIMUM OF 1" CLEARANCE TO COMBUSTIBLES FROM VENT PIPE TO WALL
MINIMUM FROM BASE TO CENTER OF TERMINATION
177⁄
8
125⁄8"
391⁄
16
"
9
7
16
"
36"
36
3
⁄8"
55
1
4
"
NAILING
TABS
1/2" For Gyprock
Facing
ON VERTICAL VENTING “MUST” MAINTAIN 1" CLEARANCE TO COMBUSTIBLES
11"
TOP VIEW
Top Vent
Back Vent
36
Back Vent Model Only
On horizontal venting, 1/4” rise per foot up to 3ft, over 3ft up to the 5ft maximum horizontal run 1 1/2” rise per foot is needed.
It is recommended for Propane Horizontal Installations that the venting should be a minimum of one foot vertical off the flue before the elbow on any horizontal runs of one foot or greater. This allows for cleaner combustion and greatly reduces carboning and cleaning of glass. (Does not apply to Back Flue Models).
323⁄16
141⁄64
141⁄64
451⁄2
NAILING
TABS
4” minimum to 45
371⁄2”
231⁄2”
8
Mantels
Depending on the depth of the fireplace mantel, it may be installed higher or lower from the top of the fireplace opening. See drawings for proper installation height of your combustible mantel. Non-combustible mantels may be installed at any height above the fireplace opening.
Non combustible materials such as brick, tile, etc. can extend up to or over the front face of the fireplace (NO PORTION OF GRILLAREA OR DOOR AREAS CAN BE COVERED).
Combustible material can extend flush to unit up to the top, bottom and sides of fireplace to stand-offs.
If slim line brass surround is used, brick, tiles or other NON-COMBUSTIBLE materials may extend past the front of unit giving a recessed appearance. For COMBUSTIBLE materials extending in front of fireplace consult (Mantel and Mantel Leg Drawings).
If wide brass surround is used finish materials must be flush with front of unit.
Note: When using paint or lacquer to finish the mantel, such paint or lacquer must be heat resistant (250˚F) to prevent discoloration.
Warning: Combustible objects must not be
placed on a non-combustible mantel unless the non-combustible mantel meets the minimum height and width requirements for a combustible mantel.
Mantel Leg Clearances
Mantels
Clearance to Combustibles
Back (from Standoffs) 0 inches/0 mm
Side (from standoffs) 0 inches/0 mm
Floor 0 inches/0 mm
Top (from standoffs) 0 inches/0 mm
Top of 90 degree bend in Minimum Enclosure of 42 inches 51/2
inches/140 mm / Kingsman Vent Systems
Top of 90 degree bend in Enclosure over 42 inches 21/2 inches/64 mm / Kingsman Vent Systems
Top of Horizontal Pipe 11/2 inches/38 mm / Kingsman Vent Systems
Side & Bottom of Horizontal Pipe 1 inch/25.5mm / Kingsman Vent Systems
Vertical Vent Pipe 1 inch/25.5mm / Kingsman Vent Systems
Vertical Vent Pipe 11/4 inch/32mm / Simpson Duravent Systems
(NOTE -Floor) if installing the appliance directly on carpeting or other combustible materials other than wood flooring, the appliance shall be installed on a metal or wood panel, the full width and depth of the appliance. Carpet may extend 1/2 inch above the floor of appliance.
Note: See Mantel Chart
9
Gas Line Installation
This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CGA - B149.1 or .2 installation codes for Gas Burning appliances and equipment in Canada and the National Fuel Gas Code ANSI Z223 in the U.S.A.
1. The gas pipeline can be brought in through either the right or the left side of the appli­ance. A knockout is provided at either location to allow for the gas pipe installation and testing of any gas connection.
2. The gas control inlet is 3/8” NPT. Typical installation layout for rigid pipe is shown at right.
3. When using copper or flex connector, use only approved fittings. Always provide a union so that gas line can be easily disconnected for burner or fan servicing. See gas specification for pressure details and ratings.
4. When a vertical section of gas pipe is required for the installation, a condensation trap is needed. See CAN/CGA-B149.1 or .2 for code details.
5. For natural gas, a minimum of 3/8” iron pipe with gas minimum pressure of 4.5” w.c. must be used for supply from the gas meter. Consult with the local gas utility if any ques­tions arise concerning pipe sizes.
6. A 1/8” NPT plugged tappings are accessible for test gauge connection both on the inlet and outlet of the gas valve.
7. Turn the gas supply ON and check for leaks. DO NOT USE OPEN FLAME FOR THIS PURPOSE. Use an approved leak testing solution.
8. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 KPa).
9. The appliance must be isolated from the gas supply piping system by closing its individ­ual shutoff valve during any pressure testing of the gas supply piping system at test pres­sures equal to or less than 1/2 PSIG (3.5 KPa).
Note: The gas line connection may be made of 1/2” rigid pipe, 1/2” copper pipe or an approved flex connector. Since some municipalities have addi­tional local codes, it is always best to consult your local authorities and the current CAN/CGA - B149.1 or .2 installation code in Canada or the National Fuel Gas code ANSI Z223.1 in the U.S.A.
Gas Specifications
Top Flue Top Flue Back Flue Back Flue
Models ZDV3624N ZDV3624LP ZDV3624NB ZDV3624LPB ZDV3628N ZDV3628LP ZDV3632N ZDV3632LP
Fuel Natural Propane Natural Propane Natural Propane Natural Propane
Gas Control Millivolt adjustable Millivolt adjustable Millivolt adjustable Millivolt adjustable Millivolt adjustable Millivolt adjustable Millivolt adjustable Millivolt adjustable
Maximum 24,000 BTU High 22,000 BTU High 24,000 BTU High 22,000 BTU High 28,000 BTU High 26,000 BTU High 30,500 BTU High 29,200 BTU High
Input 14,000 BTU Low 15,000 BTU Low 14,000 BTU Low 15,000 BTU Low 20,000 BTU Low 19,000 BTU Low 20,600 BTU Low 22,200 BTU Low
Maximum n/a n/a 17,040 BTU 15,620 BTU 21,000 BTU High 19,500 BTU High 22,900 BTU 21,900 BTU
Output
Orifice Size #42 #53 #42 #53 #37 #52 #36 #51
(0 - 4500 ft)
Air Shutter 1/8” Fully Open .188 Fully Open .25”/.218” Open 5/8”/Fully Open .187 .312
Gas Inlet Size S.I.T. 820 Nova, 3/8” NPT
Gas Supply Pressure Minimum Normal Maximum
Natural Gas 5.5” 7” 9”
Liquid Propane 11” 11” 12”
Manifold Pressure Natural Gas Liquid Propane
Manifold Pressure High 3.5 IN. W.C./.87 KPa 10 IN. W.C./2.61 KPa
Manifold Pressure Low 1.6 IN. W.C./.40 KPa 6.3 IN. W.C./1.57 KPa
Important: Always check for gas leaks with a soap and water solution. Do not use open flame for leak testing.
For the state of Massachusetts a T-handle gas
shut-off valve must be used on a gas
appliance. This T-handle gas shut-off valve
must be listed and approved by the state of
Massachusetts. This is in reference to the state
of Massachusetts state code CMR238.