Kingsman OFP42N, OFP42LP, OFP42NS, OFP42LPS Operation And Installation Manual

OUTDOOR FIREPLACE MANUAL
Models: OFP42N, OFP42LP, OFP42NS, OFP42LPS
Certified For USA & Canada
Standards: CSA 4.96 US 2nd Edition, CGA CR97-003, CGA 2.17-M91
Outdoor Gas Fireplaces
Owner’s Operation and Installation Manual
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference
IMPORTANT: Read all instructions
carefully before starting installation. Failure to follow these installation instructions may result in a possible fire hazard and will void the warranty.
Warning
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
-An LP-cylinder not connected for use shall not be stored in the vicinity or this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your
building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
-Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
This manual must be used for installation and retained by the homeowner for operation and maintenance. Save this manual for future reference. Please contact your dealer for any questions or concerns.
2340 Logan Ave., Winnipeg, MB, Canada, Phone: (204) 632-1962 –Printed in Canada- PART #42OFP-MAN Oct. 10/08
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
DO NOT LEAVE FIREPLACE UNATTENDED WHEN IN USE
FOR OUTDOOR USE
DO NOT USE FOR
COOKING.
The OFP42N and OFP42LP Fireplace are to be used only with the Logs/Rock Kits as specified in this manual. Do not burn wood or other materials in this appliance.
Warning
Warning
Warning
ONLY.
Warning
Warning
Table of Contents
SECTION PAGE
Table of Contents…………………………………………………………………………………………. 2
Introduction………………………………………………………………………………………………… 3
Pre-Installation Questions and Answers……………………………………………………………….. 4
Fireplace Dimensions and Framing Specifications………………………………………………........ 5
Installation Clearances……………………………………………………………………………..…….. 6
Screened Porch Installation……………………………………………………………………………… 6
Gas Line Installation and Gas Specifications……………………………………………………......... 7
Brick Panel Installation …………………………………………………………………….…………….. 8
Curtain and Hood Installation………………………………………………………………..…….…….. 8
Installing Stainless Steel Surround……………………………………………………………………… 9
Log Placement…………………………………………………………………………………….………. 10
MQ Rock Setup…………………………………………………………………………………………… 11
MQ Rock and Glass Setup…………………………………………………………….………………… 12
Lighting Instructions…………………….………………………………………………………………… 13
Gas Conversion -Valve-……………………………….………………………………………………… 14
Gas Conversion –Burner and Pilot-..…………………………………………………………………… 15
Troubleshooting…………………………………………………………………………………………… 16
Cleaning……………………………………………………………………………………………………. 16
Electronic Spark Assist…………………………………………………………………………………… 17
Weather Cover Installation………………………………………………………………………………. 18
Parts List …………………………………………………………………………………………………... 19
Warranty…………………………………………………………………………………………………… 20
2
OFP42N/OFP42LP Introduction
Models OFP42N/OFP42LP are for outdoor use only. This appliance MUST NOT be used for cooking.
WARNING: This appliance shall be used ONLY outdoors in a well-ventilated space and shall NOT be used inside a building, garage, or any other enclosed area.
WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
The installation must conform with local codes or in the absence of local codes, to the National Fuel Gas Code ANSI Z223.1/NFPA 54, the Natural Gas and Propane Installation Code, CSA B149.1, or International Fuel Gas Code.
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of ½ psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).
For the state of Massachusetts a T-handle gas shut-off valve must be used on a gas appliance. This T-handle gas shut-off valve must be listed and approved by the state of Massachusetts.
This is in reference to the State of Massachusetts state code
Always keep the appliance clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
Do not locate appliance where it can
get excessively wet. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which gas been under water.
Children and adults should be alerted to the
hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the area of the appliance.
CMR238.
Warning
Clothing or other flammable materials should not
be hung from the appliance or placed on or near the appliance.
Any guard or other protective device removed for
servicing the appliance must be replaced prior to operating the appliance.
Installation and repair should be done by a
qualified service person. The appliance should be inspected by a qualified service person. More frequent cleaning may be required as necessary. It is imperative that control compartment, burners and circulating air passageways of the appliance be kept clean.
Inspect the fuel supply connection (including the
hose for LP models) before each use of the appliance. See p11-Lighting Instructions for removal of Access Panel.
If it is evident there is excessive abrasion or wear,
or the hose is damaged, it must be replaced prior to the appliance being put into operation.
The LP gas supply cylinder used with LP models
must be constructed and marked in accordance with the Specifications for LP-Gas Cylinders of the US Department of Transportation (D.O.T.), or the
Standard for Cylinders, Spheres, and Tubes for Transportation of Dangerous Goods and Commission, CAN/CSA-B339* as applicable.
Cylinders must be stored outdoors in a well
ventilated area out of the reach of children. Disconnected cylinders must have threaded valve plugs tightly installed and must not be stored in a building, garage or any other enclosed area.
Storage of this appliance indoors is permissible
only if it has been disconnected from its fuel supply (natural gas line or LP gas cylinder).
The LP gas cylinder supply system must be
arranged for vapor withdraws.
The LP gas cylinder used must include a collar to
protect the cylinder valve.
When an LP model is not in use, the LP gas must
be turned off at the supply cylinder.
3
OFP42N/OFP42LP Pre-Installation Questions and Answers
4
OFP42N/OFP42LP Framing Specifications
-Fireplace and Framing Dimensions-
*Attention: Top & Rear Standoffs must be folded into position & fastened with Screws before installation.
(Dimensions allow for ½” in front of framing tabs for finishing materials.)
Framing Clearances to Fireplace and Standoffs(Unless otherwise noted): Bottom: 0”/ Sides: 0” /
Adjacent side wall: 3-1/2” /Floor of fireplace to ceiling: 7’ /Low Profile Enclosure: 43-1/2”Minimum. Back: 0” / Top: 0”.
5
,
OFP42N/OFP42LP Installation Clearances
Mantel Clearances
Notice
A qualified service person must install firebox. Follow all local codes.
Warning
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
Installation Clearances
Carefully follow the instructions below. This will ensure safe installation.
Minimum Clearances- Side Walls
Minimum Wall and Ceiling Clearances
A. Clearances from the firebox to adjacent wall should not
be less than 3-1/2 inches.
B. Clearance from the top of the fireplace front to the ceiling
should not be less than 47 inches.
C. Clearance from the bottom of the firebox to the floor is 0
inches.
D. Clearance from the side of the fireplace to the enclosure
is 0 inches.
E. Clearance from the top of the fireplace standoffs is 0
inches.
Warning
Ensure the minimum clearances shown are maintained.
Left and right clearances are determined when facing the
Warning
Maintain the minimum clearances. If you can, provide greater
clearances from the floor
ceiling, and adjoining wall.
OFP42N / OFP42LP Screened Porch Installation
Minimum porch area………………………..….….. 96sq. feet
Minimum ceiling height ……………………….…….92” inches
A minimum of two (2) walls can be screened, but must be open to outside ventilation, with a minimum screen area of 64
sq. feet, and a minimum side wall height of 78” inches.
The OFP42N and OFP42LP can be installed safely in a screened porch area within the following guidelines:
6