Kingsman FP2085, CR97-003, FP2085N, FP2085LP, FP2785LP Owner's Operation And Installation Manual

...
August 10, 2011 PART # 27FP-MAN
2
3
TABLE OF CONTENTS
1.0 INTRODUCTION ………………………………………………………………………… 4
2.0 ASSEMBLY AND INSTALLATION …………………………………………………… 5
4.0 INSTALLING RECTANGLE FIRE PIT INTO A WOOD ENCLOSURE ……………… 8
5.0 INSTALLING WALL CLEARANCE SHIELD ………………………………………… 9
6.0 FP2085 FIRE PIT ASSEMBLY…………………………………………………………… 10
7.0 FP2785 BURNER ASSEMBLY ………………………………………………………… 11
8.0 FP2785 FIREBOX & COVER ASSEMBLY …………………………………………… 12
9.0 LOG PLACEMENT INSTRUCTIONS…………………………………………………… 13
10.0 OPERATING INSTRUCTIONS ………………………………………………………… 14
11.0 MAINTENANCE INSTRUCTIONS …………………………………………………… 14
12.0 HIGH ELEVATION INSTALLATION …………………………………………………… 14
13.0 SAFETY INFORMATION AND LIGHTING INSTRUCTIONS ……………………… 15
14.0 REPLACEMENT PARTS ………………………………………………………………… 16
PRODUCT NUMBERS…………………………………………………………………… 16
LIMITED WARRANTY POLICY ……………………………………………………… 17
4
Models FP2085/FP2785 are Decorative Gas Log Set for outdoor use only. This appliance MUST NOT be used for cooking.
WARNING: This appliance shall be used ONLY outdoors in a well-ventilated space and shall NOT be used inside a building, garage, or any other enclosed area.
WARNING: This log set must NOT be installed in an unvented appliance.
WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
The installation must conform with Local codes ore in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1 or CAN/CGA-B149.1, National Gas Installation Code or CAN/CGA-B149.2, Propane installation Code.
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1/2 psig (3.5kPa).
This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa).
The following clearances to combustible construction must be maintained: Bottom - 0 inches Sides (all around)-24 inches (610 mm), and Top-7 feet (2.12 m).
Always keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
Do not locate appliance where it can get excessively wet. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been underwater.
• Children and adults should be alerted to the hazards of high surface temperatures and should
stay away to avoid burns or clothing ignition.
• Young children should be carefully supervised when they are in the area of the appliance.
• Clothing or other flammable materials should not be hung from the appliance, or placed on or near the appliance.
• Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the appliance.
• Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative the control compartment, burners and circulating air passageways of the appliance be kept clean.
• Inspect the fuel supply connection (including the hose for LP models) before each use of the appliance.
• If it is evident there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the appliance being put into operation.
• The pressure regulator and hose assembly supplied with LP models must be used. Replacement pressure regulators and hose assemblies must be those specified in this manual.
• The LP gas supply cylinder used with LP models must be constructed and marked in accordance with the specifications for LP-gas cylinders of the U.S. Department of Transportation (DOT).
• Cylinders must be stored outdoors in a well­ventilated area out of the reach of children. Disconnected cylinders must have threaded valve plugs tightly installed and must not be stored in a building, garage or any other enclosed area.
• Storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply (natural gas line or LP gas cylinder).
• The LP gas cylinder supply system must be arranged for vapor withdraws
• The LP -gas cylinder used must include a collar to protect the cylinder valve.
• When an LP model is not in use, the LP-gas must be turned off at the supply cylinder.
1.0 INTRODUCTION
For the state of Massachusetts a T-handle gas shut-off valve
must be used on a gas appliance. This T-handle gas shut-off
valve must be listed and approved by the state of Massachusetts.
This is in reference to the state of Massachusetts state code
CMR238.
5
The log set (LOGC85) and the burner assembly are shipped separately.
A. Remove the gas log set and burner assembly and
check for damage. DO NOT install damaged components. The logs are fragile use care when handling.
B. Place the burner assembly on a flat, stable surface in
an outdoor location such as a patio or a deck. This location must be adjacent to the gas supply line (natural gas) or LP-gas supply cylinder. NOTE: Minimum clearances to combustible construction must be maintained.
Remember, you must have easy access to the gas valve control knob AFTER the appliance is installed and connected to the gas supply.
THE ON/OFF GAS VALVE IS USED TO TURN THE BURNER ON AND OFF.
C. NATURAL GAS MODELS: Connect the incoming
gas supply line to the on/off gas valve of the appliance (Figure 1). Make certain ALL gas connections are tight, turn the on/off valve at the unit slowly to the on position and use soap water to test for leaks. DO NOT USE AN OPEN FLAME.
LP-GAS MODELS:
1. Make sure tank valve is in its full off position. (Turn clockwise to stop).
2. Check tank valve features to ensure it has proper external mating threads. (Tank Valve Marked: USE WITH TYPE 1 )
3. Inspect hose shipped with the unit for damage. Never attempt to use damaged or plugged equipment. See your local LP Gas Dealer for repairs.
4. After inspecting the LP hose shipped with the unit, connect the end with the female fitting on the hose to the male fitting on the on/off gas valve at the end of the flex tube and make sure it is tight.
5. When connecting regulator assembly to the tank valve, hand tighten nut clockwise to a positive stop. DO NOT use a wrench to ti
ghten. Use of a wrench may damage quick closing coupling nut and result in a hazardous condition.
6. Locate the hose out of pathways where people may trip over it or in areas where the hose may be subject to accidental damage.
7. Open tank valve fully (counter-clockwise). Turn the on/off valve at the unit slowly to the on position and use a soapy water solution to check all connections for leaks before attempting to light the appliance. If a leak is found, turn tank valve off and do not use the appliance until repairs can be made by a local LP Gas Dealer. DO NOT attem
pt to make repairs yourself.
8. Never attempt to use this appliance or any
components that have been damaged or exposed to an accidental fire.
D. ENCLOSURES FOR LP-GAS SUPPLY
SYSTEMS.
If you build an enclosure for an LP gas cylinder. follow these recommended specifications. You must also follow local codes.
Enclosures for LP-gas supply cylinders shall be ventilated by openings at the level of the cylinder valve and at floor level. The effectiveness of the opening(s) for purposes of ventilation shall be determined with the LP-gas supply cylinder(s) in place. This shall be accomplished by one of the following:
a.
One side of the enclosure shall be completely open; or
b. For an enclosure having four sides, a top and bottom:
1. At least two ventilation openings at cylinder valve level shall be provided in the side wail, equally sized, spaced at 180 degrees (3.14 rad), and unobstructed. Each opening shall have a total free area of not less than 1/ 2 square inch per pound (3.2 sq. cm/kg) of stored fuel capacity and not less than a total free area of 10 square inches (64.5 sq. cm).
2. Ventilation opening(s) shall be provided at floor level and shall have a total free area of not less than 1/2 square inch per pound (3.2 sq. cm/kg) of stored fuel capacity and not less than a total free area of 10 square inches (64.5 sq. cm). If ventilation openings at floor level are in a side wall, there shall be at least two openings. The bottom of the openings shall be at floor level and the upper edge no more than 5 inches (127 mm) above the floor. The openings shall be equally sized, spaced at 180 degrees (3.14 rad) and unobstructed.
3. Every opening shall have minimum dimensions so as
2.0 ASSEMBLY AND INSTALLATION
6
to permit the entrance of a 1/8-inch (3.2 mm) diameter
rod.
Cylinder valves shall be readily accessible for hand operation. A door on the enclosure to gain access to the cylinder valves is acceptable, provided it is non-locking and can be opened without the use of tools.
There shall be a minimum clearance of 2 inches (50.8 mm) between the lower surface of the floor of the LP-gas supply cylinder enclosure and the ground.
The design of the enclosure shall be such that (1) the LP­gas supply cylinder(s) can be connected, disconnected and the connections inspected and tested outside the cylinder enclosure; and (2) those connections which could be disturbed when installing the cylinder(s) in the enclosure can be leak tested inside the enclosure.
Be certain to mount or set the LP-gas cylinder on a flat stable surface and retain it to prevent it from tipping.
E. Purge the gas supply line of any trapped air prior to
the first firing of the unit.
WARNING: During the initial purging and subsequent lightings, NEVER allow gas valve to remain "OPEN" position without first placing a burning match on the top of the burner.
F. Place the logs on the burner assembly. See log
placement instructions.
G. Test fire the unit after referring to the SAFETY
INFORMATION and LIGHTING INSTRUCTIONS found in Section 13 of this
manual.
H. Do not leave the burner on with the cover on.
Figure 1
GAS SPECIFICATIONS
FP2085N FP2085LP FP2785N FP2785LP
Fuel Natural Gas Liquid Propane
Maximum Supply Pressure 10 IN. W.C./2.47 KPa 13 IN. W.C./3.24 KPa
I. If LP-Gas outdoor firepits are used continuously
after a couple of hours, you could see the possibility of the flame decreasing in size. If this happens, turn off the control valve and the tank valve and wait a couple of hours before lighting again or switch propane tanks. The propane tank is freezing up due to the volume of gas being taken out of the tank.
Warning
DO NOT LEAVE FIREPIT
UNATTENDED WHEN IN USE