King Pigeon S3526 User Manual

Send SMS Text Message to your Mobile Phone when alarm occurrence!
GSM Alarm System
User Manual
S3526 Ver 1.20
Date Issued: 2009-06-07 All rights reserved by King Pigeon Hi-Tech.Co.,Ltd.
www.GSMalarmsystem.com
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
Table of contents
1. Brief introduction ------------------------------------2
2. Safety Directions ------------------------------------2
3. Standard Packing list ------------------------------3
4. Physical Layout -------------------------------------3
5. Features ----------------------------------------------5
6. Settings -----------------------------------------------6
7. Operating Instructions ---------------------------- 8
8. Installation -------------------------------------------10
9. Add wireless sensors -----------------------------14
10. Technical specifications --------------------------16
11. Important information -----------------------------17
12. Maintenance-----------------------------------------17
13. Quality Warranty -----------------------------------18
14. Learning Wireless Sensor For S3526-------- 19
This handbook has been designed as a guide to the installation and operation of S3526 GSM SMS Security Alarm System. Statements contained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products. We recommend that the advice of a registered electrician be sought before any Installation work commences. King Pigeon Hi-Tech.Co., Ltd, its employees and distributors, accept no liability for any loss or damage including consequential damage due to reliance on any material contained in this handbook. King Pigeon Hi-Tech.Co., Ltd, its employees and distributors, accept no liability for GSM Network upgrading or SIMCard upgrading due to the technology specifications contained in this handbook.
King Pigeon Hi-Tech. Co., Ltd. Page of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
1. Brief introduction
The GSM Alarm System S3526 is a new security protection solution special for home, house and office and other applications. It based on Wireless GSM Communication network. When any sensor activated, it will Call&Send SMS to owners telephone immediately.
The GSM Alarm System S3526 can setup by SMS easiler.
What you need is a SIMCard which supports Call ID function.
2.Safety Directions
Safe Startup
Do not use GSM Alarm System when using GSM equipment is prohibited or might bring disturbance or danger.
Interference
All wireless equipment might interfere network signals of GSM Alarm System and influence its performance.
Avoid Use at Gas Station
Do not use GSM Alarm System at a gas station. Power off GSM Alarm System it near fuels or chemicals.
Power it off near Blasting Places
Please follow relevant restrictive regulations. Avoid using the device in blasting places.
Reasonable Use
Please install the product at suitable places as described in the product documentation. Avoid signal screening by covering the mainframe.
King Pigeon Hi-Tech. Co., Ltd. Page of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer.
Waterproofness
The product is not waterproof. Please install it at dry places and keep it dry.
3. Standard Packing List
Control Unit X1 Wireless Magnetic Door Sensor X1 Wireless Remote Controls X 2 Wireless PIR Motion Sensor X1 Wired Mini Siren(110dB) X1 GSM ANT X 1 Regulated 12vDC Power Supply X1 User Manual X1
Optional Accessories: (Wired or Wireless Sensors)
PIR Motion Sensors Glass Break Sensors
Magnetic Window Sensors Magnetic Steel Scrolling Door Sensor
Temperature Sensors and Other Sensors.
4. Physical Layout
4.1 Control Unit physical layout
Power Status
King Pigeon Hi-Tech. Co., Ltd. Page of 21 Ver 1.2 File No.: 35260011
External 12VDC Power Status LED,power on will on. Arm Status LED,in armed mode, it flashs green, always green is disarmed.
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
Busy
Always red color means the mainframe calling out or sending SMS out or triggered,normally, it flashs.
Run
GSM Network Led, flash 1 time per 1 second, means searching and registering GSM network. Flash 1 second and off 3 seconds, means the gsm netwok was registered, always on means under the communication.Otherwise,means the SIMCard hasn’t been fixed well or GSM network signal is weakness.
Alarm
Out
Monitor
Charge
Alarming it will on and the buzzer will make a sound. Relay output closed it will on, otherwise it is off. Microphone working, will on,otherwise it is off. Under charge the internal backup battery,it will on, otherwise, it is off.
4.2 8Pin connector definition
Interface
PIN 1 PIN 2 PIN 3
GND Siren positive electrode 12VDC Power Output Source, can use it for any device or sensors that need 12VDC to work.
PIN 4
Output relay negative electrode (Relate Voltage:2A/250VAC)
PIN 5
Output relay positive electrode (Relate Voltage:2A/250VAC)
King Pigeon Hi-Tech. Co., Ltd. Page of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
PIN 6 PIN 7 PIN 8
GND Wired sensor input 1 (e.g.: Temperature sensor.) Wired sensor input 2(e.g.: Photoelectric Beams Sensor.)
Tips:
1. The Output relay is similar the Power Switch, you can use it to control the light, gate,DVR and other applications. Its drived by 5VDC, related voltage is 2A/250VAC,<40W, when you use high vlotage applications, please note the cables.
5. Features
1) GSM Frequency: Dual-Band(900/1800MHz), Quad-Band is optional(850/900/1800/1900Mhz) ;
2) Supports armed, disarmed by SMS or remote control or telephone;
3) Supports start or stop the siren by telephone or SMS command;
4) Supports Swith On or Off the output relay by telephone or SMS command;
5) Automaticed send SMS Alert and dial to the pre-set cellphone when any sensor triggered;
6) Equips with 2 Wired Zones,NC/NO, and Zone Name is editable;
7) Equips with 8 Wireless Zones, Zone Name is editable;
8) Supports 3 SMS alarm cellphones and 5 dial alarm telephone numbers;
9) Equips with 1 relay output, it likes a switch, use for driving DVR, light, gate or other electric appliances once the system activated;
10) Reserved 12VDC power source from the control unit for wired sensors;
11) Supports external power failure&recovery alert function;
12) Supports wiretap through internal Mircophone;
13) Supports wired and wireless siren;
14) Supports alert user by SMS when the remote control has been used to control the system; this function can enable or disable by user;
King Pigeon Hi-Tech. Co., Ltd. Page of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
15) Standby internal rechargeable battery which can last 12 hours;
16) Based on the GSM communication network and Voice Operation Menu technology, apply to wide range situations.
6. Settings
The S3526 designed for easiler setup, all the setup can be done by SMS commands. Also, you can setup it by call, the commands are the same as the SMS Commands.
Before the setting, please read the user manual carefully. Then insert the SIMCard and fix it well, then power on the mainframe, the control unit will search and register the GSM Network automatically, once the Run Led flashs 1 second and off 3 seconds, means the gsm netwok was registered,then you can start to set it. Also, you can set the system by SMS after it finished GSM Network registration. Please setup it following the follow table:
Notice:
1) Please use SMS command to set at least one SMS Alarm Phone nu mber firstly after you reset the system, otherwise, you don’t know if the sensors learned to the system successfully;
2) When set the system by SMS, if success, will return one SMS to confirm, otherwise, means the setting failure;
3) The relay will be switched on for 3 minutes when you use phone to control it or the system triggered, or use SMS commands to switched on it.
4) If you need to reset the system to factory deflaut, then please press the Reset Button, then power on the system, once you heard “Di” sound then release the button. The button near the SIMCard Socket.
5) When set the Control Unit by phone, the system will request you input p as sw ord to enter the system. Please enter the password slowly. Otherwise, you should enter many times. if success, will make a long Di sound to confirm, if it makes didi sound, means the setting failure.The operation commands please see tables.
King Pigeon Hi-Tech. Co., Ltd. Page of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
6) Depending on the infrastructure, the SMS Command C ontrol functions may not work in all countries.
Telephone and SMS Commands For GSM Alarm System
Setup Basic Functions
Com. Functions&Descriptions
11# 11*
12#
12*
21#
21*
31#
Set the control unit when triggered, The siren will sound.(Default) When the control unit triggered, the siren will not sound. Enable to alert user by SMS when use remote control to Arm or Disarm the system; Disable to alert user by SMS when use remote control to Arm or Disarm the system;(Deflaut) Set wired zone as NC type. Set wired zone as NO type. (Default) Modify password. The original password is 1234.
Setup SMS Alert Telephone numbers
Com. Functions&Descriptions
40#
Inquire the preset SMS Alert telephone numbers. (Can’t inquire it by telephone,only by SMS.)
41# Set the 1st SMS Alert telephone Number. 42# Set the 2nd SMS Alert telephone Number 43# Set the 3rd SMS Alert telephone Number.
Setup Call Alert Telephone numbers
Com. Functions&Descriptions
50#
Inquire the preset Dial phone number. (Can’t inquire it by phone, only by SMS.)
51# Set the 1st dial phone number. 52# Set the 2nd dial phone number. 53# Set the 3rd dial phone number. 54# Set the 4th dial phone number.
King Pigeon Hi-Tech. Co., Ltd. Page of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
55# Set the 5th dial phone number.
Setup SMS Alert Contents
Com. Functions&Descriptions
70#
Inquire the Wired zone Name.(Can’t inquire it by phone)
71# Set the the1st wired zone name. (Max. 23 letters) 72# Set the 2nd wireld zone name. (Max. 23 letters) 80#
Inquire the wireless zone names. (Can’t inquire it by phone)
81# Set the 1st wireless zone name. (Max. 23 letters) 82# Set the 2nd wireless zone name. (Max. 23 letters) 83# Set the 3rd wireless zone name. (Max. 23 letters) 84# Set the 4th wireless zone name. (Max. 23 letters) 85# Set the 5th wireless zone name. (Max. 23 letters) 86# Set the 6th wireless zone name. (Max. 23 letters) 87# Set the 7th wireless zone name. (Max. 23 letters) 88# Set the 8th wireless zone name. (Max. 23 letters)
Tips!
1) Send 1234#01# to arm the system, or call into the system, then enter 1234# 01#
to arm it.
2) Change the password: send 1234#31#1111#, Or call into the system, then enter
1234#31#1111#. Means change the password 1234 to 1111.
3) Set the first dial phone Number 20202020:
Send SMS 1234#51#20202020# to the system or call the system, then enter
1234#51#20202020#.
4) Delete the preset alarm number:
Send SMS 1234#51## or call the sytsem, then enter 1234#51##. Will delete the first dial phone number, the same format to delete the other alarm phone numbers and SMS alert numbers.Send SMS 1234#41## or call the system, then enter
1234#41## to delete the first SMS alert number.
5) Change the zone name: (The zone names should less than 12 letters. ) Send
1234#81#door# to change the wireless zone 1 name to door.
6)
Please help to setup the first SMS Alert Number firstly, so that you can receive all the confirmation SMS.
King Pigeon Hi-Tech. Co., Ltd. Page of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
7. Operating Instructions
7.1 Arm or Disarm and Emergency Alarm by remote controls
Wireless ANT
Arm Button Disarm Button This Button Useless) Emergency Button
Press the button “
” on the remote control, the Control Unit enters arm status. under this status, any sensor triggered, the control unit will alarm and the siren will sound 90S.
Press the button “
” on the remote control, the Control Unit disarms immediately. under this status, any sensor triggered, the control unit will not alarm and the siren will not sound, except the Emergency Button.
Press Emergency button” ” on the remote control or Press any Emergency button.The Control Unit will enter emergency alarm status. The siren will not sound, but will alert the pre-set phone number immediately.
7.2 Arm or Disarm by SMS and Telephone.
There’re two way to operate it. Method 1: Send SMS to Arm or Disarm; 2: Call to the Control unit. In order to operate it easier, we designed simply commands, as below:
King Pigeon Hi-Tech. Co., Ltd. Page of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
SMS & Call Operation Instructions
XXXX#01#---Arm XXXX#01*---Disarm XXXX#02#--- Switch ON the relay output for 3 minutes. XXXX#02* --- Switch OFF the relay output. XXXX#03# --- Switch ON the siren for 3minutes XXXX#03* --- Switch OFF the siren immediately.
(XXXX Stands for the password.)
7.3 External AC power failure alarm
When the system detects a power cut in external AC power for longer then two seconds it will send SMS to the SMS Alert target cell phones.when the AC power restored, it will send SMS to you, without calling.
7.4 Handling the received alarm
If the Control Unit receives any alarm signal from any sensors, will start the siren intermittently for 90Seconds and switch on the relay output for 3 minutes. At the same time,dial the Call alert telephone numbers one by one. If programmed, it will also send SMS to SMS Alert Target cell phones, the SMS content will include the zone name. If answered the alarm calling, you can listen into sounds from the alarm system area. After answered the call, press XXXX# to enter the system, then press 01# to arm, press 01* to disarm. (XXXX stand for Password) If the user hangs up, the Control Unit will stop alarm and call other alarm telephones, until answered.
7.5 Arm/disarm and wiretap through telephone
You can use any telephon e to call the Control Unit, after detecting 15 seconds will make click sounds, waiting for you to enter the password. if the entered password is correct, you can arm or disarm it and listen in the control unit area.
8. Installation
King Pigeon Hi-Tech. Co., Ltd. Page 10 of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
Before installing the control unit and sensors and sirens, please help to test the system firstly, including wireless sensor, wired sensor, power supply, gsm signal, etc.
8.1 Insert SIM into Control Unit
In the backside of the control unit, please install the GSM SIM
card
.
8.2
Install the Magnetic door/window sensors
Magnetic door/window sensors signal the Control Unit when the two parts separate by more than between 1.5 to 3.0cm.
King Pigeon Hi-Tech. Co., Ltd. Page 11 of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
In some circumstances an Infrared beam fence is more appropriate than magnetic sensors. i.e. veranda, picture window balcony, boundary wall e.t.c.
Wired or wireless glass break sensor can also be used (see below)
For a Scrolling Steel Door, a special Wireless Scroll Steel Door magnetic sensor, must be used due to interference of the wireless signal caused by the steel door.
Installation: attach the larger half to the floor and attach (rivet or glue) the smaller half to the scroll steel door. An alarm is triggered when the halves
King Pigeon Hi-Tech. Co., Ltd. Page 12 of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
are separated by more than three to 5.00 cm.
Scroll Steel Door
8.3 Install the wireless PIR Motion Sensor
The PIR sensor will detect a person since human temperature is different to ambient temperature. When triggered, the PIR will signal the Control Unit. Apply the detection area illustration below when installing.
Wireless curtain sensor, detection area illustration below:
King Pigeon Hi-Tech. Co., Ltd. Page 13 of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
8.4 Install other sensors
For smoke, you can use wireless smoke sensor, for gas leakage detection, you can install gas leakage sensor below
8.5
Install the Control Unit
In order to avoid destruction of the Control Unit by intruders, please install it in a concealed location, convenient to the operator. If applicable, ensure that an uninterruptible AC power outlet is available near the Control Unit. First connect accessories to the Control Unit then the AC adapter.
8.6 Install Siren
Connect the Siren and the Speaker to the Control Unit and fix them in appropriate locations .
Strobe Siren Siren Linght Siren
King Pigeon Hi-Tech. Co., Ltd. Page 14 of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
8.7 Install Other Wired Sensors
Connect the sensors’t two cable to the interface 2 is ok, the S3022 can supports 4 Wired Sensors, so you can add Wired Photoelectric Beams sensors for outter, install temperature sensors, water leakage sensors, wired smoke sensor, wired Panic Button, Wired PIR Motion Sensors and so on.
9. Add Wi reless Sensors to the Control Unit
The Wireless sensors in the package box are pre-coded prior to shipping. Add additional wireless sensors to the control units, please help to see below:
1) Open the back cover of the Wireless sensor carefully;
2) Locate the IC boards black jumpers, labelled A0-A7 and D0-D3.
3) The A0-A7 , 3X8 PIN connectors,are the Wireless Address bits code
area, and the D0-D3 are 3X4 PIN connectors, are Wireless data bits code area;
4) Also, you can see the H, N, and L letters besides the 3X8 PIN and 3X4
PIN connectors, like below;
5) Connect L and N is means 0, and connect H and N is means 1,
connect neither L and N nor H and N is means 2 ;
6) According to below table, select the Zone and set the 3X4 PIN
Wireless data bits code area according to selected zone.
7) According to the wireless sensors in the Standard package, set all
wireless sensors’ Wireless Address bits the same. Then install the cover carefully.
8) Turn off the sensors’ power before setting .
9) Trigger the wireless sensor and test the setting result. If the wireless
sensors do not work, please check the jumpers again.
10) You can set many sensors in the same zone.
Notice:
After you restored the system to factory deflaut(By press the Reset Button), you should learn the wireless senors to the control units again. The method
King Pigeon Hi-Tech. Co., Ltd. Page 15 of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
is below:
Step 1: Power on the Control Units and waiting it registered successful; Step 2: Press the Reset button in the backside of the control unit, nearby
the Simcard Solt;the Busy LED will turn Red Color, trigger any wireless sensor, the Busy Led will flash and make “Di” Sound to confirm the operation. If the control unit doesn’t makes “Di” sound, means the learning failure, please try again.
Appendix: Zone Setting Table
Serial No. Deflaut Zone Name
Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8
SOS Alarm
Wireless Zone Activated Wireless Zone Activated Wireless Zone Activated Wireless Zone Activated Wireless Zone Activated Wireless Zone Activated Wireless Zone Activated Wireless Zone Activated Emergency Alarm
Wireless data bits
D0 D1 D2 D3
0 1 0 1 1 1 0 1 0 0 1 1 1 0 1 1 0 1 1 1 1 1 1 1 1 0 0 1 1 0 1 0 0 0 1 0
Notice:
1. All the Zone Names can be edited by user through SMS Commands;
King Pigeon Hi-Tech. Co., Ltd. Page 16 of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
10. Technical specifications of Control Unit
Rated Voltage: 12VDC 1.5A Working temperature: -10~+60
Storage temperature: -20~+60
Relative humidity: 10-90%, No condensation
Work frequency: GSM900,1800Mhz Communication protocol: GSM PHASE 2/2+ (include data service)
Wireless sensor receiving frequency: 433+/-0.5MHz
Wired Zones: 2 Wireless Zones: 8
Related Voltage of the Output Relay: 2A/250V AC Effective distance of wireless transmission: 100 m (Open area) Battery: Built-in lithium-ion battery: 1000mAh 7.2V Standby time Approx. 12hours (dep ending on the network
condition)
Net Weight: 0.80Kg
11. Important information
1) Please read the User Manual carefully before you install the Control
Unit and set the Control Unit.
2) Do not install the system in close vicinity with objects that generate
strong interference, such as TV set and computer.
3) Install the system in a hidden place.
4) Avoid getting water into the Control Unit.
5) Have a secure connection to the main power supply.
6) This product was designed for the indoor use.
7) Opening the control unit cover will void the warranty.
King Pigeon Hi-Tech. Co., Ltd. Page 17 of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
12. Maintenance
1) In case of failure, please contact the distributor or manufacturer.
2) If the Control Unit works, while the remote control and other sensors fail, please check and change the battery.
3) If the remote control works, but the ,Control Unit fails to send SMS texts, switch the power of Control Unit off and switch it on after one minute. Test this system after another minute, or check the settings are correct and the GSM Signals are strong enough.
4) If the Control Unit can run and sensors work, but cannot send SMS texts, please change SIM Card to check it.
5) If the problem cannot be solved, please contact the distributor or manufacturer.
13. Warranty
1) This system is warranted to be free of defects in material and workmanship for one year from the date of purchase.
2) This warranty does not extend to any defect, malfunction or failure caused by abuse or misuse by the Operating Instructions. In no event shall the manufacturer be liable for any alarm system altered by purchasers.
The End!
Any questions please help to contact us feel free.
Email Us: Sales@Kingpigeon.com.cn
Http://www.GSMalarmsystem.com
Http://www.Kingpigeon.com.cn
King Pigeon Hi-Tech. Co., Ltd. Page 18 of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
Learning Wireless Sensor For S3526
When you want to clear all settings, then you can reset the system. After reset it, all the sensors and remote controls can’t work with the mainframe. Need learn all of them again. Learning Sensors Method:
1. Press the Reset Button, then Busy Led will change into Red color, then press any button of the remote control once, the Busy Led will flash and the mainframe make a di sound. If no any sound response, means the learning failure, please try again.
2. Power on the Mainframe and wait a moment, when the mainframe enter into normally status;
3. Setup a SMS Number, then use the remote control to try it. (if not setup SMS number, can not know if the remote control learned successful or not.)
4. Set the other remote controls as the same connection with the learned one(Need to open the remote control cover to see the PCB.) and get the wireless code, as below mentioned A0~A7 is 11020220.
5. If you want to plus other wireless sensor to this panel, then open the cover of the sensor, Setup the DIP switch A0~A7 the same as the remote control. And the D0~D3 is for setting the zone, please see the user manual page 16 table, if you want to setup this wireless sensor to zone 1, then please setup D0~D3=0101, See below:
King Pigeon Hi-Tech. Co., Ltd. Page 19 of 21 Ver 1.2 File No.: 35260011
A Top Safety and Protection Solution In The Worldwide! www.GSMalarmsystem.com
6. Also, please note the 1.5M,3.3M,4.7M three DIP Switch you have choose the 4.7M. see below:
King Pigeon Hi-Tech. Co., Ltd. Page 20 of 21 Ver 1.2 File No.: 35260011
Loading...