![](/html/69/6935/6935edf1d19f4c9f7325805fff8b272dec5788b1f616a5545178f73f6d94d88a/bg1.png)
PORTABLE OXYGEN CONCENTRATOR
# P2
No: DO-P2-01 Version No:A/0,software version:KNMed_P2_18_08_v3.1.01
![](/html/69/6935/6935edf1d19f4c9f7325805fff8b272dec5788b1f616a5545178f73f6d94d88a/bg3.png)
CONTENTS
Ⅰ.USE INTENTION ,CONTRAINDICATIONS AND GENERAL PRECAUTION.............. 2
Use Intention........................................................................................................................ 2
Contraindications................................................................................................................. 3
General Precaution
General Precaution---Continued
General Precaution---Continued....................................................................................... 5
General Precaution---Continued....................................................................................... 6
Ⅱ.DESCRIPTION OF THE KINGON P2 OXYGEN CONCENTRATOR............................ 7
Important Parts of the Kingon P2
User Interface Instruction and Symbols used on Kingon P2........................................ 8
Alerts................................................................................................................................... 12
Power Supply..................................................................................................................... 14
Accessories
Accessories List.................................................................................................................16
Ⅲ.OPERATING INSTRUCTIONS
General Operation
Ⅳ.TROUBLESHOOTING.........................................................................................................22
Ⅴ.MAINTENANCE AND CLEANING OF KINGON P2....................................................... 23
Cleaning the Case.............................................................................................................23
Cannula Replacement...................................................................................................... 23
Filter Cleaningand Replacement
Battery Care and Maintenance
Disposal of Equipment and Accessories....................................................................... 26
Maintenance Items Lists.................................................................................................. 26
Ⅵ.SYSTEM SPECIFICATIONS.............................................................................................. 27
Concentrator Specification...............................................................................................27
Classifications.................................................................................................................... 28
Standards Compliance
EMC Information
EMC Information-Continued............................................................................................ 31
Ⅶ.WARRANTY
..........................................................................................................................
.............................................................................................................
.......................................................................................
......................................................................................
........................................................................................................................
..........................................................................................
.............................................................................................................
....................................................................................
.......................................................................................
.....................................................................................................
................................................................................................................
15
17
17
23
24
29
30
32
3
4
7
![](/html/69/6935/6935edf1d19f4c9f7325805fff8b272dec5788b1f616a5545178f73f6d94d88a/bg4.png)
A warning indicates that the personal safety of the patient may be
involved. Disregarding a warning could result in significant injury.
A caution indicates that a precaution or service procedure must
be followed. Disregarding a caution could lead to a minor injury or
damage to equipment.
See User Manual for Instructions.
U.S. Federal Regulation Restricts this Device to Sale by Order of
Physician. May also be applicable in other Countries
Keep away from open flames
Do Not Disassemble (contact your equipment provider for
servicing by authorized personnel)
Do Not Dispose of In Unsorted Municipal Waste
Class II (Double Insulated)
Complies With Applicable EU Directives ; Including Medical
Device Directive
Authorised representative in the European Community
Protection against vertically falling water drops
![](/html/69/6935/6935edf1d19f4c9f7325805fff8b272dec5788b1f616a5545178f73f6d94d88a/bg5.png)
Use Intention, Contraindications and General Precaution
This device is not intended to be life-sustaining or
life-supporting. This device is not intended for newborn and
infant use.
A backup oxygen source is recommended for power outages
or mechanical problems. Please provide your device with a
backup system type recommended by the business
consultant.
This device restricted to sale by or on the order of a
physician in many countries. May also be applicable in your
country.
It is the responsibility of the patient to make back-up
arrangements for alternative oxygen supply when traveling;
Kingon assumes no liability for persons not to adhere to
manufacturer recommendations.
The expected life is depending on the environment of usage
and the maintenance. The bad condition will short the life
time of the concentrator.
500 full charge/discharge cycles
The operator should read and understand this entire manual
before using the device.
.USE INTENTION ,CONTRAINDICATIONS AND GENERAL
Ⅰ
PRECAUTION
Use Intention
Intended use:The Kingon P2 Oxygen Concentrator is used on a prescriptive basis by
patients requiring supplemental oxygen .It supplies a high concentration of oxygen to
the patients .
It supplies a high concentration of oxygen and is used with a nasal cannula to channel
oxygen from the concentrator to the patient. The Kingon P2 is small, portable and may
be used in home, institution and various mobile environments.
![](/html/69/6935/6935edf1d19f4c9f7325805fff8b272dec5788b1f616a5545178f73f6d94d88a/bg6.png)
Use Intention, Contraindications and General Precaution
This device is not intended to be life sustaining or life suppo
rting.
Patients who use this device may require additional monitori
ng or attention, and these patients cannot hear or see an al
ert or communicate discomfort. If the patient has any sympt
oms, consult a physician immediately.
In certain circumstances, oxygen therapy can be hazardous.
Please seek medical advice before using this device.
The Kingon P2 is not designed or specified to be used in
conjunction with a humidifier, nebulizer or connected with
any other equipment. Do not modify the Kingon P2
Concentrator. Any modifications performed on the
equipment may impair performance or damage equipment
and will void your warranty.
Oxygen supports combustion. Oxygen should not be used
while smoking or smoking in the same room ,or in the
presence of an open flame.
Do not submerse the Kingon P2 or any of the accessories in
liquid.
Do not expose to water or precipitation.
Do not operate in exposed rain.
This could lead to electrical shock and/or damage.
Do not use oil or grease on the concentrator or its
components as these substances, when combined with
oxygen, can greatly increase the potential for a fire hazard
and personal injury.
Never leave the Kingon P2 in an environment which can
reach high temperatures or high humidity, such as an
unoccupied car in high temperature environments or
bathroom with high humidity. This could damage the device.
Geriatric or any other patient unable to communicate
discomfort, or hear or see the alarms while using this device,
may require additional monitoring
Contraindications
General Precaution
![](/html/69/6935/6935edf1d19f4c9f7325805fff8b272dec5788b1f616a5545178f73f6d94d88a/bg7.png)
Use Intention, Contraindications and General Precaution
If you feel discomfort or are experiencing a medical
emergency while undergoing oxygen therapy, seek medical
assistance immediately to avoid harm
The oxygen delivery settings of the oxygen concentrator
should be periodically reassessed for the effectiveness of
the therapy
Set the device at the prescribed level and do not increase or
decrease your flow rate from the prescribed level until you
frst consult with your physician or healthcare professional
Only use this device as prescribed.
The use of oxygen therapy can be hazardous in some
circumstances, so consult your health care practitioner
before using Kingon P2
To ensure that you receive the correct therapeutic amount of
oxygen delivery according to your medical condition, the
Kingon P2 must be used:
● Only after one or more settings have been individually
determined or prescribed for you at your specific activity
levels
● only use the parts and accessories that are provided by
oxygen concentrator manufacturer Kingon .
The settings of the Kingon P2 might not correspond with
continuous flow oxygen
The settings of other models or brands of oxygen therapy
equipment do not correspond with the settings of the Kingon
P2
There is a risk of fire associated with oxygen
equipment and therapy. Do not use near sparks or open
flames
General Precaution---Continued
![](/html/69/6935/6935edf1d19f4c9f7325805fff8b272dec5788b1f616a5545178f73f6d94d88a/bg8.png)
Use Intention, Contraindications and General Precaution
Use only water-based lotions or salves that are oxygen
compatible during setup or use during oxygen therapy To
avoid the risk of fre and burns, never use petroleum or
oil-based lotions or salves
Smoking during oxygen therapy is dangerous
and is likely to result in serious injury or death of the patient
and others from fire
To ensure receiving the therapeutic amount of oxygen
delivery according to your medical condition Kingon P2 must
— be used only after one or more settings have been
individually determined or prescribed for you at your
specific activity levels.
— be used with the specific combination of parts and
accessories that are in line with the specification of the
oxygen conserver manufacturer and that were used while
your settings were determined.
Do not lubricate replaceable fittings,connections, tubing,
or other accessories of the oxygen conserver to avoid the
risk of fire and burns
Use only spare parts recommended by the manufacturer
to ensure proper function and to avoid the risk of fire and
burns
Wind or strong draughts can adversely affect accurate
delivery of oxygen therapy.
EXAMPLE 1 Using this equipment beside an open window
or in front of a fan can affect the accuracy of delivery of
oxygen.
EXAMPLE 2 Using this equipment in the back seat of an
open convertible car can affect the accuracy of delivery of
oxygen.
General Precaution---Continued
![](/html/69/6935/6935edf1d19f4c9f7325805fff8b272dec5788b1f616a5545178f73f6d94d88a/bg9.png)
Use Intention, Contraindications and General Precaution
If you notice any of the following, STOP use immediately and
contact your equipment provider :
● unexplained changes in the performance of this device
● unusual or harsh sounds
● dropped or mishandled device or the power supply
● water spilled into the enclosure
● broken enclosure
Oxygen is a combustion-supporting gas, a fire will start
easier and spread quickly.
Do not leave the nasal cannula on bed coverings or chair
cushions if the oxygen concentrator is turned on, but not in
use; Turn the oxygen concentrator off when not in use
To ensure proper function and to avoid the risk of fire and
burns:
● Use only with Kingon P2 AC power supply
● Use only with Kingon P2 batteries
● Use only approved Kingon P2 accessories
Remove the battery from the device if Kingon P2 will not be
used for a long period of time
Device operation exceed the voltage, breath rate,
temperature, humidity and/or altitude values specified
may decrease oxygen concentration levels
Do not modify this system or equipment in any way .
Modifications could result in hazards to the user
Change in altitude may affect to actual oxygen supplied to
you .Do consult your physician before travelling to a place
with altitude changes.
General Precaution---Continued
Note: Additional warnings, cautions, and notes are located throughout the
manual.
![](/html/69/6935/6935edf1d19f4c9f7325805fff8b272dec5788b1f616a5545178f73f6d94d88a/bga.png)
Description of the Kingon P2 Oxygen Concentrator
.DESCRIPTION OF THE KINGON P2 OXYGEN CONCENTRATOR
Ⅱ
Important Parts of the Kingon P2
![](/html/69/6935/6935edf1d19f4c9f7325805fff8b272dec5788b1f616a5545178f73f6d94d88a/bgb.png)
Description of the Kingon P2 Oxygen Concentrator
Press once to turn “ON”;
Press and hold for one second to turn “OFF”
Pressing the button will toggle the Kingon P2’s
audible alert on and off.
The display’s mode indication area will show 2
different icons on mute & audible mode:
on audible mode-----
On mute mode-------
and turn on yellow light, and display message when
the alert is enable.
Press this button to mute or unmute alarms .
Flow Setting
Control Buttons
Select the setting by pressing the – or +
buttons ,swift from 1 to 5 different flow setting
Press this button to display the information of device.
The information includes battery temperature,battery
status,molecular temperature,molecular runtime,
device model,device temperature,device runtime ,
firmware version, hardware version.
User Interface Instruction and Symbols used on Kingon P2
User control: