Kingon P2 User Manual

PORTABLE OXYGEN CONCENTRATOR
# P2
No: DO-P2-01 Version No:A/0,software version:KNMed_P2_18_08_v3.1.01
CONTENTS
.USE INTENTION ,CONTRAINDICATIONS AND GENERAL PRECAUTION.............. 2
Use Intention........................................................................................................................ 2
Contraindications................................................................................................................. 3
General Precaution General Precaution---Continued
General Precaution---Continued....................................................................................... 5
General Precaution---Continued....................................................................................... 6
.DESCRIPTION OF THE KINGON P2 OXYGEN CONCENTRATOR............................ 7
Important Parts of the Kingon P2
User Interface Instruction and Symbols used on Kingon P2........................................ 8
Alerts................................................................................................................................... 12
Power Supply..................................................................................................................... 14
Accessories
Accessories List.................................................................................................................16
.OPERATING INSTRUCTIONS
General Operation
.TROUBLESHOOTING.........................................................................................................22
.MAINTENANCE AND CLEANING OF KINGON P2....................................................... 23
Cleaning the Case.............................................................................................................23
Cannula Replacement...................................................................................................... 23
Filter Cleaningand Replacement Battery Care and Maintenance
Disposal of Equipment and Accessories....................................................................... 26
Maintenance Items Lists.................................................................................................. 26
.SYSTEM SPECIFICATIONS.............................................................................................. 27
Concentrator Specification...............................................................................................27
Classifications.................................................................................................................... 28
Standards Compliance EMC Information
EMC Information-Continued............................................................................................ 31
.WARRANTY
..........................................................................................................................
.............................................................................................................
.......................................................................................
......................................................................................
........................................................................................................................
..........................................................................................
.............................................................................................................
....................................................................................
.......................................................................................
.....................................................................................................
................................................................................................................
15
17 17
23 24
29 30
32
Symbol
Meaning
WARNING
A warning indicates that the personal safety of the patient may be involved. Disregarding a warning could result in significant injury.
CAUTION
A caution indicates that a precaution or service procedure must be followed. Disregarding a caution could lead to a minor injury or damage to equipment.
See User Manual for Instructions.
AC Power
DC Power
U.S. Federal Regulation Restricts this Device to Sale by Order of Physician. May also be applicable in other Countries
No Smoking
Keep away from open flames
Keep Dry
Use No Oil or Grease
Do Not Disassemble (contact your equipment provider for servicing by authorized personnel)
Do Not Dispose of In Unsorted Municipal Waste
Type BF Applied Part
Class II (Double Insulated)
Complies With Applicable EU Directives ; Including Medical Device Directive
See Instructions for Use
Manufacturer
Authorised representative in the European Community
Protection against vertically falling water drops
Date of manufacture
Serial Number
Use Intention, Contraindications and General Precaution
WARNING
This device is not intended to be life-sustaining or life-supporting. This device is not intended for newborn and infant use.
WARNING
A backup oxygen source is recommended for power outages or mechanical problems. Please provide your device with a backup system type recommended by the business consultant.
CAUTION
This device restricted to sale by or on the order of a physician in many countries. May also be applicable in your country.
CAUTION
It is the responsibility of the patient to make back-up arrangements for alternative oxygen supply when traveling; Kingon assumes no liability for persons not to adhere to manufacturer recommendations.
CAUTION
The expected life is depending on the environment of usage and the maintenance. The bad condition will short the life time of the concentrator.
Service Item
Expected Life
Kingon P2 Oxygen System
5 Years
Molecular Sieve Beds
1 Years
Batteries
500 full charge/discharge cycles
WARNING
The operator should read and understand this entire manual before using the device.
.USE INTENTION ,CONTRAINDICATIONS AND GENERAL
PRECAUTION

Use Intention

Intended use:The Kingon P2 Oxygen Concentrator is used on a prescriptive basis by patients requiring supplemental oxygen .It supplies a high concentration of oxygen to the patients . It supplies a high concentration of oxygen and is used with a nasal cannula to channel oxygen from the concentrator to the patient. The Kingon P2 is small, portable and may be used in home, institution and various mobile environments.
Use Intention, Contraindications and General Precaution
CAUTION
This device is not intended to be life sustaining or life suppo rting.
CAUTION
Patients who use this device may require additional monitori ng or attention, and these patients cannot hear or see an al ert or communicate discomfort. If the patient has any sympt oms, consult a physician immediately.
CAUTION
In certain circumstances, oxygen therapy can be hazardous. Please seek medical advice before using this device.
CAUTION
The Kingon P2 is not designed or specified to be used in conjunction with a humidifier, nebulizer or connected with any other equipment. Do not modify the Kingon P2 Concentrator. Any modifications performed on the equipment may impair performance or damage equipment and will void your warranty.
WARNING
Oxygen supports combustion. Oxygen should not be used while smoking or smoking in the same room ,or in the presence of an open flame.
WARNING
Do not submerse the Kingon P2 or any of the accessories in liquid. Do not expose to water or precipitation. Do not operate in exposed rain. This could lead to electrical shock and/or damage.
CAUTION
Do not use oil or grease on the concentrator or its components as these substances, when combined with oxygen, can greatly increase the potential for a fire hazard and personal injury.
CAUTION
Never leave the Kingon P2 in an environment which can reach high temperatures or high humidity, such as an unoccupied car in high temperature environments or bathroom with high humidity. This could damage the device.
WARNING
Geriatric or any other patient unable to communicate discomfort, or hear or see the alarms while using this device, may require additional monitoring

Contraindications

General Precaution

Use Intention, Contraindications and General Precaution
WARNING
If you feel discomfort or are experiencing a medical emergency while undergoing oxygen therapy, seek medical assistance immediately to avoid harm
WARNING
The oxygen delivery settings of the oxygen concentrator should be periodically reassessed for the effectiveness of the therapy
WARNING
Set the device at the prescribed level and do not increase or decrease your flow rate from the prescribed level until you frst consult with your physician or healthcare professional
WARNING
Only use this device as prescribed. The use of oxygen therapy can be hazardous in some circumstances, so consult your health care practitioner before using Kingon P2
WARNING
To ensure that you receive the correct therapeutic amount of oxygen delivery according to your medical condition, the Kingon P2 must be used:
● Only after one or more settings have been individually determined or prescribed for you at your specific activity levels
● only use the parts and accessories that are provided by oxygen concentrator manufacturer Kingon .
WARNING
The settings of the Kingon P2 might not correspond with continuous flow oxygen
WARNING
The settings of other models or brands of oxygen therapy equipment do not correspond with the settings of the Kingon P2
WARNING
There is a risk of fire associated with oxygen equipment and therapy. Do not use near sparks or open flames

General Precaution---Continued

Use Intention, Contraindications and General Precaution
WARNING
Use only water-based lotions or salves that are oxygen compatible during setup or use during oxygen therapy To avoid the risk of fre and burns, never use petroleum or oil-based lotions or salves
WARNING
Smoking during oxygen therapy is dangerous and is likely to result in serious injury or death of the patient and others from fire
WARNING
To ensure receiving the therapeutic amount of oxygen delivery according to your medical condition Kingon P2 must be used only after one or more settings have been individually determined or prescribed for you at your specific activity levels. be used with the specific combination of parts and accessories that are in line with the specification of the oxygen conserver manufacturer and that were used while your settings were determined.
WARNING
Do not lubricate replaceable fittings,connections, tubing, or other accessories of the oxygen conserver to avoid the risk of fire and burns
WARNING
Use only spare parts recommended by the manufacturer
to ensure proper function and to avoid the risk of fire and
burns
WARNING
Wind or strong draughts can adversely affect accurate delivery of oxygen therapy. EXAMPLE 1 Using this equipment beside an open window or in front of a fan can affect the accuracy of delivery of oxygen. EXAMPLE 2 Using this equipment in the back seat of an open convertible car can affect the accuracy of delivery of oxygen.

General Precaution---Continued

Use Intention, Contraindications and General Precaution
WARNING
If you notice any of the following, STOP use immediately and contact your equipment provider :
● unexplained changes in the performance of this device
● unusual or harsh sounds
● dropped or mishandled device or the power supply
● water spilled into the enclosure
● broken enclosure
WARNING
Oxygen is a combustion-supporting gas, a fire will start easier and spread quickly. Do not leave the nasal cannula on bed coverings or chair cushions if the oxygen concentrator is turned on, but not in use; Turn the oxygen concentrator owhen not in use
WARNING
To ensure proper function and to avoid the risk of fire and burns:
● Use only with Kingon P2 AC power supply
● Use only with Kingon P2 batteries
● Use only approved Kingon P2 accessories
WARNING
Remove the battery from the device if Kingon P2 will not be used for a long period of time
WARNING
Device operation exceed the voltage, breath rate, temperature, humidity and/or altitude values specified may decrease oxygen concentration levels
WARNING
Do not modify this system or equipment in any way . Modifications could result in hazards to the user
WARNING
Change in altitude may affect to actual oxygen supplied to you .Do consult your physician before travelling to a place with altitude changes.

General Precaution---Continued

Note: Additional warnings, cautions, and notes are located throughout the manual.
Description of the Kingon P2 Oxygen Concentrator
.DESCRIPTION OF THE KINGON P2 OXYGEN CONCENTRATOR

Important Parts of the Kingon P2

Description of the Kingon P2 Oxygen Concentrator
Symbol
Item
Description
ON / OFF
Button
Press once to turn “ON”; Press and hold for one second to turn “OFF”
Audio Alarm
Button
Pressing the button will toggle the Kingon P2’s audible alert on and off.
The display’s mode indication area will show 2 different icons on mute & audible mode:
on audible mode-----
On mute mode-------
and turn on yellow light, and display message when the alert is enable. Press this button to mute or unmute alarms .
Flow Setting
Control Buttons
Select the setting by pressing the – or + buttons ,swift from 1 to 5 different flow setting
Device
Information
Press this button to display the information of device.
The information includes battery temperature,battery status,molecular temperature,molecular runtime, device model,device temperature,device runtime , firmware version, hardware version.
User Interface Instruction and Symbols used on Kingon P2
User control:
Loading...
+ 25 hidden pages