King-Gage ES2 550*-1 Series Installation And Operation Instructions Manual

ES2 Electronic Liquid Level Transmitter EX-1832Effective: August, 2004 EX-1832
®
KING-GAGE
4-20 mA Remote Liquid Level Transmitter
ES2
Remote Liquid Level Transmitter Model 550*-1-** w/Cable and Junction Enclosure
Installation and Operation Instructions
Page 1
ES2 Electronic Liquid Level Transmitter EX-1832
© 2004 King Engineering Corporation. All rights reserved.
The information contained in this manual was accurate at the time of release. Specifications are subject to change without notice.
Warranty - All King Engineering products are guaranteed to be free from defects in material and workmanship for one year from the date of purchase. Any product or part found to be defective under normal use within one year of purchase will be repaired or replaced at no charge if returned to the company at Ann Arbor, Michigan within ten days of discovery of the defect. No other warranties, whether expressed, implied or statutory, including the warranties of fitness for a particular purpose or merchanta­bility, are given by this agreement. The exclusive remedy for nonconformity of these goods shall be repair and/or replacement of the nonconforming goods or parts.
Seller will not be liable for consequential damages resulting from breach of this agreement. The term “consequential damages” shall include but shall not be limited to damage to all machines, equipment and goods other than the goods sold hereby, interruption of production, loss of profits, delays of any kind, administrative expense, and overhead.
Revisions:
(A) August, 2004 - Original Release
Page 2
ES2 Electronic Liquid Level Transmitter EX-1832
KING-GAGE ES2 Level Transmitter
Two-wire sensor/transmitter provides a direct 4-20 mAdc analog electronic output signal. Fixed-range transmitter is designed specifically for hydrostatic pressure measurement for liquid level gauging.
Transmitter package includes 15 feet of cable and corro­sion-resistant Signal Junction Enclosure. (This enclosure also houses the external zero adjustments and signal loop connection terminals.)
Model No. Designations
55xx-1-xx
Pressure Range
05 ............... 0-5 psig
10 ............... 0-10 psig
15 ............... 0-15 psig
30 ............... 0-30 psig
50 ............... 0-50 psig
Configuration (Housing)
01 ..... Short Mount
02 ..... Standard Mount
03 ..... Long Mount
Range Designation
A model number/range designation is listed on the end of the transmitter housing. The last two digits of the model number actually refer to the transmitter range. As an example, MODEL 5502-1-10 is a 0-10 psig range, standard mount transmitter.
Insulated
Tank Wall
Clamp Nut
MODEL/RANGE
5701-1-15 PSIG
Flush-Weld Tank Shell
Junction
Enclosure
KING-GAGE
Electronic
4-20 mA
Sensor
®
Page 3