Please keep your dated proof of purchase for warranty and servicing purposes.
REPLACEMENT PARTS
Replacement parts for this tool are available at our authorized KING CANADA service centers across Canada. For servicing, contact
or return to the retailer where you purchased your product along with your proof of purchase.
LIMITED TOOL WARRANTY
KING CANADA makes every effort to ensure that this product meets high quality and durability standards. KING CANADA warrants to
the original retail consumer a 2-year limited warranty as of the date the product was purchased at retail and that each product is free
from defects in materials. Warranty does not apply to defects due directly or indirectly to misuse, abuse, negligence or accidents,
repairs or alterations and lack of maintenance. KING CANADA shall in no event be liable for death, injuries to persons or property or
for incidental, special or consequential damages arising from the use of our products. To take advantage of this warranty, the product
or part must be returned for examination by the retailer. Shipping and handling charges may apply. If a defect is found, KING CANADA
will either repair or replace the product.
KING CANADA
OOLS INC. DOR
T
AL, QUEBEC, CANADA
V
H9P 2Y4
Page 3
GETTING TO KNOW YOUR NAILER
Air deflector
Safety release
SPECIFICATIONS
Trigger
Air inlet
Magazine latch
Magazine
Nail loading area
Nail discharge area
Model ............................................................................................................................................................................................8200B
Air inlet ......................................................................................................................................................................................1/4” NPT
Compressed air:
Maximum permissible operating pressure ................................................................................................................120 PSIG (8.3 bar)
Recommended operating pressure range ............................................................................................................................70-100 PSI
Nail range ....................................................................................................................................5/8” to 2” 18ga. brad head finish nails
Nail capacity ....................................................................................................................................................................100 brad nails
• Read and understand this manual and all the safety instructions before operating this nailer. If
you have any questions, please contact our authorized service centres or retailers for help.
• Never allow the use of flammable gases as a power source for the nailer. Use filtered,
lubricated and regulated compressed air only.
• Never use gasoline or other flammable liquids to clean this nailer. Vapors in the nailer will ignite
by a spark and cause the nailer to explode.
• Do not exceed the maximum permissible operating pressure of this nailer (120 PSIG).
• Disconnect the nailer from its air supply before clearing jams, servicing, adjusting and while the
nailer is not in use.
• Do not keep the trigger pulled on contact safety trip mechanism when carrying or holding the
nailer. Never carry the nailer by the air hose or pull on the air hose to move the nailer.
• At the workplace, always wear protective equipment such as Z87 safety glasses, hearing and
head protection.
• Do not use a check valve or any other fitting which allows air to remain in the nailer.
• Do not place your hand or any part of your body in the nail discharge area of the nailer when
connecting or disconnecting from the air supply.
• Never point any operational nail driving tool at yourself or at any other person.
Page 5
LUBRICATION
AIR SUPPLY AND CONNECTIONS
LUBRICATION AND MAINTENANCE
• Your nailer needs to be lubicated before and after the first time you use it.
• Disconnect the air supply from the nailer before lubricating.
• Turn the nailer so that the inlet is facing up and put
detergent into the air inlet. Never use detergent oil or additives. Operate the nailer briefly after adding
oil.
• Wipe off excessive oil at the exhaust. Excessive oil will damage O-rings of the nailer. If a in-line oiler
is used, manual lubrication through the air inlet is not required on a daily basis.
AIR SUPPLY AND CONNECTIONS
WARNING!
THE FOLLOWING ILLUSTRATION SHOWS THE CORRECT MODE OF CONNECTION TO THE AIR
SUPPLY SYSTEM WHICH WILL INCREASE THE EFFICIENCY AND USEFUL LIFE OF THE NAILER.
Air hose
Quick couplers
Quick connector
Quick
connector
Oiler
Regulator
ONE DROP of high speed spindle oil or oil without
Filter
Compressor
• Many air tool users find it convenient to use an oiler to help provide oil circulation through the tool and
it increases the efficiency and useful life of the tool. Check oil level in the oiler daily.
• Many air tool users find it convenient to use a filter to remove moisture and impurities which can rust
or wear internal parts of the tool. A filter also increases the efficiency and useful life of the tool. The
filter must be checked on a daily basis and, if necessary
• For better performance, install a 3/8” quick connector (1/4” NPT
.315” on your tool and a 3/8” quick coupler on the air hose.
, drained.
threads) with an inside diameter of
Page 6
FIRING MODES &
VERIFICATION
Operational modes
This nailer may be operated in either “sequential” or “bump fire” mode.
Sequential Mode
This firing method is recommended when precise nail placement is required. In sequential mode, the nailer is actuated by depressing the
nailer nose against the work surface, the trigger then needs to be pulled and released each time a nail is driven.
Bump Fire Mode
This firing method is recommended when less precise nail placement is required. In bump fire mode, the trigger must be depressed with the
nailer nose off the work surface. Then, the nose of the nailer is tapped against the work surface causing a nail to be driven. Each time the
nailer nose is depressed, a nail is driven.
OPERATING A CONTACT SAFETY TRIP TOOL (SEQUENTIAL MODE):
• The operator is required to have the finger off the trigger and the nose of the nailer to be placed on the
workpiece.
• The contact safety trip mechanism is then depressed against the workpiece and the trigger is pulled to
drive the nail.
• The trigger is released after each nail is driven.
• Move the nailer to the next location and repeat the above procedure.
VERIFICATION
• Disconnect the air supply from the air inlet.
• Empty all nails from the magazine.
• Make sure the trigger and the contact safety trip mechanism moves up and down without sticking.
• Connect the air supply to the nailer air inlet.
• Depress the contact safety trip mechanism against the workpiece without pulling the trigger. The
nailer must not cycle.
Never use the tool if a cycle occurs.
• Hold the nailer clear of the workpiece. The contact safety trip mechanism should return to its original
down position. Pull the trigger. The tool must not cycle.
• Depress the contact safety trip mechanism against the workpiece and pull the trigger, the nailer must
cycle.
Never use the nailer if a cycle occurs.
Page 7
LOADING NAILER & CLEARING JAMS
LOADING NAILER MAGAZINE
• Disconnect the air hose from the nailer air inlet.
• Depress the magazine latch, pull back on the magazine cover.
• Insert a stick of nails into the magazine. Make sure the pointed ends of the nails are as close to the
bottom edge of the magazine as possible, ensuring the head of the nail is aligned with the
appropriate machined groove in the magazine.
• Push the magazine cover forward until the latch catches.
CLEARING JAMS
Disconnect the nailer from the air compressor before adjusting, clearing jams, servicing,
relocating and during non-operation.
• Disconnect the air hose from the nailer air inlet.
• Depress the magazine latch, pull back on the magazine cover and remove all nails.
• Undo the three cap screws (A) and remove the front plate (B) and the intermediary plate (C) from the
nailer. Using pliers, remove the jammed nail from nail discharge area (D) and reinstall all parts in reverse
order and secure them in place using the same 3 cap screws.
Page 8
OPERATING YOUR NAILER
OPERATING YOUR NAILER
WARNING! protect your eyes and ears. Wear Z87 safety glasses with side shields. Wear hearing
rotection. Employers are responsible for ensuring the user or anyone near the nailer wears the
p
above mentioned safety protection.
WARNING! Check and replace any damaged or worn components.
• Add one/two drops of 30W oil for air tools into the air inlet.
• Install a quick connect fitting to the nailer.
• Connect the nailer to an air compressor using a 3/8” I.D. hose. Make sure the magazine does not
contain any nails and that the air hose has a rated working pressure exceeding 200 psi and a female
quick coupler.
• Regulate the air pressure to obtain 85 psi. Check the operation of the contact safety trip mechanism
following the instructions in this manual.
• Load magazine with nails following the instructions in this manual.
• Reconnect the air hose to the nailer air inlet.
• Test for proper nail penetration by driving nails into scrap wood. If the nails do not achieve the desired
penetration, regulate the air pressure to a higher setting until the desired penetration is achieved. Do
not exceed 100 psi.
Page 9
MAINTENANCE & TROUBLESHOOTING
CLEANING YOUR NAILER
• Never use gasoline or other flammable liquids to clean the nailer. Vapors in the nailer will ignite
by a spark and cause the tool to explode and result in death or serious personal injury.
• Disconnect the air supply from the nailer.
• Remove tar buildup with #2 kerosene fuel oil or diesel fuel. Do not allow solvent to get into the
cylinder or dammage may occur. Dry off the tool completely before use.
TROUBLESHOOTING CHART
WARNING: Stop using this tool immediately if any of the following problems occur. Serious personal injury could occur. Any
repairs or replacements must be done by a qualified person or an authorized service centre only.
ProblemCauseSolution
• Air leaking at trigger valve
area.
• Air leaking between
housing and nose.
• Air leaking bewteen
housing and cap assembly.
• Nailer skips a nail.
• Nailer runs too slowly or
has loos of power.
• Jammed nails.
• O-rings in trigger valve are damaged.
• Loose screws in housing.
• Damaged O-rings.
• Bumper damage.
• Loose screws.
• Damaged seal.
• Worn bumper.
• Dirt in nailer nose.
• Dirt or damage prevents nails from moving freely in the magazine.
• Inadequate air flow to nailer.
• Worn O-ring on piston or lack of
lubrication.
• Damaged O-rings on trigger valve.
• Air leaks.
• Cap seal is leaking.
• Nailer is not sufficiently lubricated.
• Broken spring in cap assembly.
• Exhaust port in cap is blocked.
• Driver guide worn or damaged.
• Nails are bent.
• Magazine or nose screws are loose.
• Damaged driver.
• O-rings must be replaced and safety trip
mechanism must be verified.
• Screws need to be tightened.
• O-rings must be replaced.
• Bumper needs to be replaced.
• Screws need to be tightened.
• Seal must be replaced.
• Bumper needs to be replaced.
• Clean.
• Magazine must be cleaned.
• Fitting hose and air compressor need to
be checked.
• O-rings must be replaced, lubricate.
• O-rings must be replaced.
• Screws and fittings need to be tightened.
• Seal needs to be replaced.
• Lubricate.
• Spring needs to be replaced.
• Damaged internal parts must be replaced.
• Replace driver guide.
• Replace with undamaged nails.
• Screws need to be tightened.
• Replace driver.
REPLACEMENT DRIVER, BUMPER & O-RING REPAIR KITS
After prolonged use of your Nailer, the internal O-rings, Bumper & Driver may have to be replaced
o repair
T
caused by wear & tear
Kit is available for your Nailer (model: KW
more information.
PARTS DIAGRAM & PARTS LISTS
Refer to the Parts section of the King Canada web site for the most updated parts diagram and
parts list.
.
, a complete Driver
-1
, Bumper & O-ring Replacement
17). Contact your local King Canada distributor for
Accessory
KW-117
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.