1Overview
KB2000 is data protocol converter which transmits the data between RS232/RS485 and TCP/IP network.It is special used for Internet network data transmission, also can be used in Local network. KB2000 will receive the data from converter’s RS232/RS485 COM Port and transmit the data to Network Data Server of TCP/IP network transparently; the Network Data Server will transmit data to the KB2000’s RS232/RS485 COM port. In other words, so long as connect two KB2000’s COM port with different PC or device, their Network Port be connected with internet, the different PC or device can communicate through internet.
KB2000 supply 10M/100M Ethernet interface upwards, and supply one standard RS232 (or RS485) COM port. It have 16K buffer, its parameters can be set by software, the baud rate support from 300bps to 115200bps. KB2000 can suit for all kinds of network environment. KB2000 can apply to all kinds of network environment, network parameter and COM parameter, KB2000 can be set by configuration software or by User’s programming.
Two types of KB2000:
Type A (KB2000-A), this type mainly for Main station (Master station), as control center, it commonly connect with PC;
Type B (KB2000-B), this type mainly for slave station, as remote terminal, it commonly connect with user’s devices, instruments, meters and so on.
Mainly Application (based on Internet):
Remote AMR system
LED Display information issue system
water conservancy, atmosphere monitoring
POS network
Power automatically , transformer monitoring system
Industry instruments and meters automation engineering
Linkage or multinational group device monitoring network
2Interface and appearance
2.1 Indicator light
LED1Above LED, Double color, Network cable connected it show green(No
connected No light),if 串口 data send and receive from Serial port, It will be red.
LED2: Below LED, Double Color, when power supply connected It will show red, when KB2000 connected with server, it will change to green.
2.2 Network interface: RJ45connect with TCP/IP network.
Shenzhen Kingbird network technology CO.,LTD KB2000 Data Converter(for Internet)
3
2.3 COM interface: RS232 or RS485.
KB2000 have 10 pinsfrom left to right : PIN1-PIN10 they are defined as follow:
Pin No. Definition Description For User
1 VCC Power: DC6~24V
2 GND Ground
3 UTXD
TXDDTU COM/RS485: A
RS232,TTL:RXD; RS485:A
4 URXD
RXDDTU COM/RS485: B
RS232,TTL:TXD; RS485:B 5 Output1 Output NO.1 of IO 6 Input1 Input No.1 of IO
7
UGND Ground (COM) RS232,TTL, RS485:Data
groud 8 Output2 Output No.1 of IO 9 Status Online is high,offline is low 10 Input2 Input No.2 of IO
VCC GND UTXD1/A URXD1/B Output1 Input1 GND Output2 status Input2
Shenzhen Kingbird network technology CO.,LTD KB2000 Data Converter(for Internet)
4
3The parameters of KB2000
3.1 General parameters
Name: Named current KB2000, the Max length is 16bytes (ASCII code);
Password: When you set the parameters of KB2000, you must input password,
password is 6bytes ASCII code;
Type: Include A and B two types. Type A is mainly used in Main station, Type B is
mainly used in slave station;
ID: Current KB2000’s ID; Target ID: If the type of KB2000 is type A, this item just is used. When type A
wants to communicate with type B, this item value is set to the ID of type B;
Zone valid: If you want to use Zone, you must set it to ON; Zone: The current KB2000’s Zone number of the Network; if type A wants to
communicate with a quantity of type B, you must set type A and type B the same Zone number, and the Zone valid all be set ON;
Heart beat: The interval of KB2000 connection or communicate with remote
server.
3.2 Network parameters
IP: IP address of KB2000, when it join into one subnet, its IP must be distributed
depend on the network section.
Gateway: The gateway of subnet which KB2000 accessed.
Subnet Mask: It depends on the subnet.
Get IP from: The type of getting IP include Manually and Automatic. In Manually,
IP address can be set, KB2000 will use the IP address which user set. If in Automatic, KB2000 can get the IP address by DHCP protocol, DHCP server must be in the subnet, if you can not get IP through automatic, please use manually.
Protocol: Network protocol support UDP and TCP;
Target IP: KB2000 is client-side working way, it must have server IP.The default value is Kingbird’s, if user don’t have server, can use Kingbird’s server for free (if quantity is less) or hire Kingbird’s server (if quantity is more), then this value no need to reset. Target TCP port: The TCP port for specified KB2000 communicate with Target Main machine, The default value is the TCP port of Kingbird’s, if user don’t have server, can use Kingbird’ s server for free (if quantity is less) or hire Kingbird’ s server (if quantity is more), then this value no need to reset.
Target UDP port: The UDP port for specified KB2000 communicate with Target
Main machine, The default value is the TCP port of Kingbird’s, if user don’t have server, can use Kingbird’ s server for free (if quantity is less) or hire Kingbird’ s server (if quantity is more), then this value no need to reset.
Shenzhen Kingbird network technology CO.,LTD KB2000 Data Converter(for Internet)
5
3.3 COM parameters
Baud rate: The data transmit speed. User must set it same as PC or terminal
device which connected. The bard rate of KB2000 support from 300pbs to 115200pbs;
Data bits: In COM port asynchronous transmission, a group data real include data
digit. KB2000 support 5-8Bits data bits. Data bits must be set the same as the PC or terminal device which connected. In general it is 8bits;
Verify: KB2000’s COM verify have three types: None, Even, Odd. User must set it
same as PC or terminal device which connected.
Stop bit s: In COM port asynchronous transmission, a data digit to indicate the end
of this group data. KB2000 support one and two stop bits. User must set it same as PC or terminal device which connected. In general the stop bits is 1bit;
Max MEM. Time: When KB2000 received data from COM port, it will go into the
buffer, if over Max MEM Time, and there are not next data come in, KB2000 will transmit the data to the network.
Max MEM. Bytes: When KB2000 received enough length data from COM port,
KB2000 will transmit the data to the network. KB2000 will transmit the data to network when it satisfies Max MEM. Time and Max MEM. Bytes in one of two conditions.
4Operation and Management
Firstly user is advised to connect KB2000 with the same subnet through network
cable by Switch or HUB, and power on it, User can set KB2000.
User can Manage KB2000 with the program (NetConvertor.exe). NetConvertor
can manage all KB2000 in current subnet. It can search KB2000, view KB2000 parameters, set KB2000 and so on. The interface of the program as follow: