SAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTIONS
PZ SERIES HEATER
It is extremely important you verify the electrical power supply is the same voltage as the heater you
are installing. 208/240/277 and 120 Volt heaters are not interchangeable. Powering a 208/240/277
Volt unit with 120 Volt supply wires will reduce the heater output by approximately 75%. Powering a 120
Volt unit with 208/240/277 Volt supply wires will destroy the heater and voids all warranties.
CAUTION: Turn off power source supplying the heater before attempting installation, maintenance, or
repairs. Lock or tag circuit breaker or fuse panel door. Failure to do so could result in serious electrical
shock, burns, or possible death.
1. After removing the heater from the carton check to make sure the heater has not been damaged in shipment.
2. Remove the grille by loosening and removing the two screws on the front panel.
3. Remove the fan heater assembly by loosening the mounting screw. The assembly will now drop out.
4. Remove one 7/8" knockout and thread the supply wire into the wallbox. Use an approved strain relief bushing to
prevent chafing of the supply wires through the opening in the wallbox.
5. Install wall can a minimum of 6" from vertical side walls and 4" above floor. Secure the wallbox to 2" x 4" studs or
adequate support in the wall using the 4 holes provided on each side of the wallbox. The face of the wall
can must be 1/2" beyond the sheet rock or finished wall.
6. Replace the fan heater assembly by sliding it over the tab at the back bottom inside edge of the wallbox. Replace
the screw and tighten assembly mounting screw at the top of the wall can.
7. Attach the field groundwire to the green screw or pig tail.
8. Connect the supply wires to the leads from the heater.
9. Replace the front grille and secure with the two screws provided. The top first louver in the grille must be open in to
and between wall can and top of heater for proper circulation of air.
10. The installation is now complete and the heater may be energized for use.
This heater includes a manual
reset thermal protector with a
self-hold feature. If the heater
shuts off with the on position
and the room temperature is
below the highest thermostat
In-built thermostat
may be installed by
customer or factory
Metal Sheath Element
12-5/8"
Wall Can
6-1/4"
setting, immediately disconnect the power to the heater at
the circuit breaker and inspect
for any objects on or adjacent to
the heater that may cause high
Wall opening
6-1/4" x 12-5/8"
temperatures. After inspecting
the heater, keep the power off
to the heater for 10 minutes
to reset the thermal protector.
Remove ½" knockout for
thermostat shaft exposure
Fan blower
heating element
interior assembly
If the heater thermal protector
shuts the heater off again,
immediately turn the heater
off at the circuit breaker and
inspect the heater for possible
Top fi rst louver in the grille must
be open into and between wall can
and top of heater interior for proper
circulation of air
fan motor failure or dirt and lint
on the heating element. Repeat
starting procedure.
Front Grille
Grille Dimensions
Depth - 3/4"
Height - 7-1/2"
Width - 13-7/8"
PZ.indd : 7/09
KING ELECTRICAL MFG. COMPANY • 9131 10th Ave South • Seattle, WA 98108 • Ph: 206.762.0400 • Fax: 206.763.7738 • www.king-electric.com
SAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTIONS
PZ Series
Wiring Diagram
In-built thermostat
may be installed by
customer or factory
Remove ½" knockout for
thermostat shaft
exposure
Heating Element
Black
Fan
Motor
Optional Thermostat
Black
High Limit
To Half Wattage: Remove one colored wire from
element. Properly insulate end and secure to avoid
causing a dead short. Do not remove BLACK wire.
Warning: Check nameplate voltage on
heater before connecting to power source.
12-5/8"
Wall Can
Wall opening
Fan blower
heating element
interior assembly
6-1/4" x 12-5/8"
6-1/4"
Single Pole
Red
Black
Green
Field Connections
Top fi rst louver in the grille must
be open into and between wall can
and top of heater interior for proper
circulation of air
L1
L2
Ground
Grille Dimensions
Depth - 3/4"
Front Grille
Maintenance & Warranty Information:
Height - 7-1/2"
Width - 13-7/8"
FAN-F OR CED HE ATE RS:
Clearances for Safe Operation
The high quality and superior design of this heater will provide
years of trouble-free performance. Each year the heater
should be checked and cleaned for lint and dust accumulation.
We recommend using a soft bristle brush such as a paint
brush to assist in removing contaminants from the heater.
Limited One Year Warranty:
King Mfg. Co. will repair or replace, without charge, any King
product found to be defective or malfunctioning
during
the
first year of purchase to the original owner. The PZ-Series
wall heater carries an Extended Five Year Warranty on the
heating element.
PZ.indd : 7/09