KING LPWV User Manual

INSTALLATION INSTRUCTIONS
SAVE THESE INSTRUCTIONS
LPW2045T, LPWA2045T, LPW2445T, LPWA2445T, LPW2740T, LPWA2740T
240 VOLT MODELS with Disconnect Breaker and Remote User Switch
It is ALWAYS recommended to order your unit with or without the thermostat for your particular application. If your unit has been ordered incorrectly please contact the factory and we can exchange it for the proper unit. Adding a built-in thermostat after installation is complicated and could result in creating wiring errors and shorting out the unit.
Instructions for wall mount heater with built-in thermostat
reduce the heater's output by approximately 75%. Powering a 120 Volt unit with 208, 240 or 277 Volt supply wires will destroy the heater and voids all warranties.
NOTICE: For heaters without built-in thermostats, using remote or wall-mounted thermostats: the power must be brought to the heater first (not to the wall-mounted or remote thermostat). This is necessary to provide power for the fan to cool down the element after the thermostat has opened. Use only a single pole line voltage wall thermostat or switch to control this heater.
CAUTION: Open the circuit breaker supplying the heater before attempting installation, maintenance, or repairs. Lock or tag circuit breaker panel door. Failure to do so could result in serious electrical shock, burns, or possible death.
1. Remove heater contents from carton and check for shipping damage.
2. Remove grille by loosening the four mounting screws along the sides of the front panel.
3. Detach interior assembly from the wall can by removing the four screws along each side of the interior panel. Lift and tilt assembly away from the top of the wall can. Free the bottom edge from the metal lip inside the wall can. Place the interior assembly in a safe location until the wall can is mounted.
4. Remove one knockout from the wall can and thread supply wires through the hole. Use an approved cable connector to prevent wires from chafing. Connect groundwire to green pigtail.
5. Mount heater wall can on wall studs a minimum of 6" from side wall and 4" from floor, using the holes provided in the sides of the box. The face of the box should be flush with the finished wall. Installation of the interior and grille to the wallbox cover an approximate 5/8" periphery along the outer area of the opening.
6. After wall can is secured interior assembly leads may be attached to supply wires and interior secured to wall can. NOTE: The LPW wall heater is equipped with two steel elements having a capacity of 2250 Watts each, for a combined capacity of 4500 Watts. The heater is factory­ wired at 4500 Watts. To adjust the heater for lower wattages remove the appropri ate colored wire according to the illustration and wattage diagram provided on the back side of this sheet. Be sure to insulate and secure the unused lead.
7. Reinstall interior assembly on wallbox using screws provided.
8. Mount grille to interior with screws provided.
9. Installation is now complete and the heater ready for use.
FAN-FORCED HEATERS: Clearances for Safe Operation
VISUAL ALARM
This heater includes a visual alarm to warn that parts of the heater are getting excessively hot. If the alarm flashes, immediately turn the heater off and inspect for any objects on or adjacent to the heater that may cause high temperatures.
Do not operate the heater with the alarm flashing.
Maintenance & Warranty
The high quality and superior design of this unit will enable years of maintenance free performance. Once yearly the heater should be checked for lint or dust accumulation but no further maintenance is required. The motor is permanently lubricated and sealed. A 5-year warranty is provided on the Pic-A-Watt® element and 1-year on all materials, components and workmanship.
OWNERS GUIDE & INSTALLATION INSTRUCTIONS SHOULD BE LEFT WITH HEATER FOR HOME OWNER
KING ELECTRICAL MFG. COMPANY • 9131 10th Ave So. • Seattle, WA 98108 • Ph: 206.762.0400 • Fax: 206.763.7738 • www.king-electric.com
LPW-As with disconnect.indd : 8/09
INSTALLATION INSTRUCTIONS
This heater includes a visual alarm to warn that parts of the heater are getting excessively hot. If the alarm flashes immediately turn the heater off and inspect for any objects on or adjacent to the heater that may cause high temperatures. Do not operate the heater with the alarm flashing.
INSTALLATION INSTRUCTIONS
This heater is shipped from the factory wired for maximum wattage of 4500 Watts. To reduce the wattage unplug (disconnect) an insulated push on terminal and wrap with electrical tape to prevent the possibility of electrical contact with other parts.
Field Wattage Selection
A - ORANGE Disconnects 1000 Watts B - BLUE Disconnects 750 Watts C - YELLOW Disconnects 500 Watts D - BLACK Do Not Disconnect (Common) E - RED Do Not Disconnect
D
Common
EC
B
750
1000
D
Common
AE
E
750
1000
END VIEW OF ELEMENT
SHOWING QUICK CONNECT TERMINALS
2250 • 2750 • 3000 • 3250 • 3750 • 4000 • 4500
WATTAGES AVAILABLE IN ONE UNIT
500
500
SAVE THESE INSTRUCTIONS
21¾"
13"
½"
E
RED
B
BLUE
C
YELLOW
Insulated Push on
Terminal
A
ORANGE
E
RED
E
RED
RED #14
Insulated Push on
Terminal
FAN
Thermostat
Terminal Block
BLACK #14
RED #14
Pic-A-Watt
Metal Sheath Element
CONNECTIONS
knob position OFF.......L1-0, L2-0
knob position FAN.......L1-2, L2-4
knob position HEAT......L1-1, L2-4, L2-3
FAN DELAY
1-3 N.C., 1-2 N.C. 1-2 Closes on Temp Rise
LPW2045T, LPWA2045T, LPW2445T, LPWA2445T, LPW2740T, LPWA2740T
DELAY
2
3
®
1
GRAY #16
Safety Light
1000 WATT
750 WATT 500 WATT
1000 WATT
750 WATT
500 WATT
BLACK#16
PURPLE #16
FAN
1
Rotary Switch
L1
BLACK
11½"
D
BLACK #14
ORANGE #14
Breaker
BLACK #16
2
SAFETY
LIGHT
3
L2
BLACK
D
4
Disconnect
LPW-As with disconnect.indd : 8/09
LIMIT
OWNERS GUIDE & INSTALLATION INSTRUCTIONS SHOULD BE LEFT WITH HEATER FOR HOME OWNER
KING ELECTRICAL MFG. COMPANY • 9131 10th Ave So. • Seattle, WA 98108 • Ph: 206.762.0400 • Fax: 206.763.7738 • www.king-electric.com