Electrical Instant Water Heater
Kullanma Kılavuzu / Instruction Manual
K 7005
Şofben
Electrical Instant Water Heater

MAIN PARTS
1- Hot water output
2- Cold water input
3- Step switch
4- Power indicator
5- Step I indicator light
6- Step II indicator light
7- Shower accessory
1
3
7
4
5
6
2

We thank you for having selected the KING Electrical Instant Water Heater. Your
appliance, an expedient product with a modern outlook, gives you instant hot water
and is easy to use.
In order to obtain the maximum efficiency from your appliance and to use it safely,
please read the following instructions carefully.
IMPORTANT SAFEGUARDS
■
To have your appliance that has a calorific power of 7000 W set up you will need
qualified electricians and plumbers to have your electicity and water installation
aranged accordingly.
■
It is the customer’s resposibility to have the electricity and water installation fixed
so as to conform the electrical instant water heater.
■
Authorized Service will only carry out the electrical connections between the
installation and the device, and perform the initial operation.
■
The electrical connection of your KING Electrical Instant Water Heater should be
grounded. The appliance should be no way be used in buildings that have no ground
connection, insufficient ground connection or grounding that no appropriate with
regulations. Otherwise, our company shall not be held resposable for any problems
that may ensure.
■
Your device is for household use only. Do not use outdoors for commercial or
industrial purposes. (such as coiffeur, worksite, small atelier where need constantly
warm water).
■
Your appliance should not be connected to main water supply of your home; it is
only connected in the bathroom or anywhere that proper for the authorized service.
■
At the first time operating your appliance, do not switch on the electrical citcuit
before having the tank (the water reservoir of the appliance) filled with water.
■
Do not install your appliance at places where the water is likely to freeze. If water
frozen do not operate the appliance.
■
Your electrical instant water heater should be connected to an automatic fuse of
at 40 amperes.
■
There will be differences in the input water temperatures according to the seasonal variations. You may obtain the water you need by arranging the water temperature
selection switch and water input quantity to suit your requirements.
■
While your electrical instant water heater is in use do not operate other devices
with over 1000 W power ( oven, iron, washing machine, dishwasher, etc.).
■
In the case of low water flow or water supply failure, the appliance’s power supply
is cut. When enough water flow is reached power supply is resumed.
■
You are recommended to have a pressure regulator installed on the cold water
input side of your electrical instant water heater, when using at such places with a
water pressure of 6 bars or more.

■
The hoses and pipes that are to be directly connected with the installation need to
sustain a working pressure of 6 bars.
■
Without a person who is responsible for the security of the devices and without
providing necessary conditions for surveillance and management of the device, it is
not intended to use that device by the people (including children) who is disabled
physically or mentally and who has lack of experiance and knowledge about that
product.
■
Children must be kept under supervision to be sure that they are not playing with
the device.
In order to deal all ports of trouble and breakdown and to provide spare parts
definetely apply to Authorized Service.
DEFINITIONS AND SPECIFICATIONS
7 SECURITY SYSTEMS
1.The resistance of your appliance is a covered tube resistance and so the
resistance wire never tuoches with water. Thanks to this feature, the current
electricity does not contact with the water and that prevents the electric shocks.
2.When the water flow is too low or there is no water, diaphragm switch cut off the
water heater’s power supply, if even your appliance is powered on.
3.When water is over heated, the thermostat which is within the heating reservoir
switches off to ensure absolute safety. If the water temperature comes to normal
degrees, it switches again.
4.When any blockage at the water discharge of the appliance becomes, the return
system switches off your appliance, in order to prevent the sudden increases of the
water temperature.
5.The security valve lying on the heating reservoir empties the over water flow and
thus prevents any damages of the user and the appliance.
6.Within the heating reservoir, where tube resistances were inserted, durably water
will become held and thus plastic accessories of the equipment are protected from
damaging of losses water until they becomes cool.
7.Against the fact that the user is not to leave the appliance open was powered on,
there is an indicator light in front of it.
STEP INDICATOR SWITCH
(WATER TEMPERATURE SELECTION SWITCH)
This switch allows you to turn on and off your
electrical instant water heater and to adjust your
hot water level. The appliance has three steps
including 3000 W, 4000 W, and 7000 W,
whichever one you may desire to choose
according to the water temperature.

0 - No heating
1 - 3000 W
2 - 4000 W
3 - 7000 W
INDICATOR LIGHTS
There are three indicator lights on your appliance,
which indicate at which step in operates and whether
there is any tension on it.
N-AUTOMATIC POWER SWITCH
N-Automatic power switch functions as the key, when set to position ‘’off’’ this power
switch will automatically cut-off the connection of the instant water heater with power
supply. This power switch is mountec to the appliance not to the fuse panel.
DIAPHRAGM SWITCH
When the water flow is low, it switches on automatically to cut off the water heater’s
power supply and ensures the resumtion on the operation of water heater when the
normal water flow returns.
SAFETY THERMOSTAT
When water is over – heated, the heater’s resistance switches off to ensure absolute
safety.
TO BE DONE BY A QUALIFIED SERVICE
RESISTANCE TO WATER FLOW
Taking into account the main water flow of the city, your electrical instant water
heater has been already subjected to a test under the water flow of 11 bars.
WATER HEATER’S MONTAGE ONTO THE WALL
■
Ensure that the wall to which you are to mount the appliance be of an even
surface.
■
Mark the places of nipples by using the montage pattern given with the appliance
■
Drill 4 places in which nipple can enter completely (8 mm)
■
Insert the nipple into the hole and turn the screw to a distance of 3 mm to the
nipple.
■
Montage the heater’s body by assembling screw through hanger seats.
ASSEMBLY OF SHOWER ACCESSORIES
In order to assemble your electrical instant water heater onto the place you deemed
appropriate, drill two holes with a size that the nipples can easily enter (8 mm).
■
Fix the showhanger by using screws from holes to nipples.
■
Your showhanger is of rotating type, allowing you to arrange the position up and
down.

CONNECTING THE ELECTRICAL INSTANT WATER HEATER TO THE
SHOWER ACCESSORIES
■
By using two spiral hoses supplied with your electrical instant water heater
connect the portable shower accessory to the electrical instant water heater, the ¾
‘’ extremity of the other spiral hose to the accessory, and its ½ ‘’ extremity to the
electrical instant water heater.
■
By using the rubber gaskets supplied with the accessory complete the couplings.
■
Never use any shower accessory of other appliance instead of this shower
accessory giving with your appliance.
ELECTRICAL LINKAGE
■
The working voltage range of your electrical instant water heater is 220 – 240
volts.
■
The power of your electrical instant water heater is 7000W. The internal
installation of the building ought to be arranged to conform a power of 7000W.
■
Grounding is absolutely necessary. The appliance should in no way be used in
buildings that have no ground connection, inadequate ground connection or the
ground connection is not convinient with rules. Otherwise, our company shall not be
held responsable for any problems that may ensure.
■
The distance and tension loss of the electricity between the electrical panel of your
entrance and the electrical instant water heater should be taken into account. A
cable whose cross – section is at least 4 mm2 40 amperes should be used. (Reduction factors are also to be taken into account.)
■
The electricity line of your appliance connected is distinct from the insurance
panel of your home and the automatic fuse should be at 40 amperes. There must
any plug, lamp or any other things in this line or if there is it must be cancelled. If it
is not possible to draw a direct line for the water heater, if the current line within the
building accordingly, a line which is on the next plug socket distributer (buat) is
pulled to the bathroom. In this case the other plug sockets connected with the
respective line are cancelled. The protection connected with this line should be at 40
amperes.
■
It is necessary to use the 3*4 mm2 of Antigron cabel if the current plant is not
appropriate and the installment which has a standart grounding must be connected
directly to the water.
■
If the main insurance vlue of your home is not enough, the main insurance should
be changed with new one which has proper value after calculation of the electrician.
■
Connection of ground and neotral line method which is called making zero, etc. İs
not acceptable for grounding and never connect to this type lines.