KING K 7005 Instruction Manual

Model No: K 7005
Şofben
Electrical Instant Water Heater
Kullanma Kılavuzu / Instruction Manual
K 7005
Şofben
Electrical Instant Water Heater
1- Hot water output 2- Cold water input 3- Step switch 4- Power indicator 5- Step I indicator light 6- Step II indicator light 7- Shower accessory
1
3
7
4
5
6
2
We thank you for having selected the KING Electrical Instant Water Heater. Your appliance, an expedient product with a modern outlook, gives you instant hot water and is easy to use. In order to obtain the maximum efficiency from your appliance and to use it safely, please read the following instructions carefully.
IMPORTANT SAFEGUARDS
To have your appliance that has a calorific power of 7000 W set up you will need qualified electricians and plumbers to have your electicity and water installation aranged accordingly.
It is the customer’s resposibility to have the electricity and water installation fixed so as to conform the electrical instant water heater.
Authorized Service will only carry out the electrical connections between the
installation and the device, and perform the initial operation.
The electrical connection of your KING Electrical Instant Water Heater should be grounded. The appliance should be no way be used in buildings that have no ground connection, insufficient ground connection or grounding that no appropriate with regulations. Otherwise, our company shall not be held resposable for any problems that may ensure.
Your device is for household use only. Do not use outdoors for commercial or industrial purposes. (such as coiffeur, worksite, small atelier where need constantly warm water).
Your appliance should not be connected to main water supply of your home; it is
only connected in the bathroom or anywhere that proper for the authorized service.
At the first time operating your appliance, do not switch on the electrical citcuit before having the tank (the water reservoir of the appliance) filled with water.
Do not install your appliance at places where the water is likely to freeze. If water
frozen do not operate the appliance.
Your electrical instant water heater should be connected to an automatic fuse of
at 40 amperes.
There will be differences in the input water temperatures according to the season­al variations. You may obtain the water you need by arranging the water temperature selection switch and water input quantity to suit your requirements.
While your electrical instant water heater is in use do not operate other devices with over 1000 W power ( oven, iron, washing machine, dishwasher, etc.).
In the case of low water flow or water supply failure, the appliance’s power supply is cut. When enough water flow is reached power supply is resumed.
You are recommended to have a pressure regulator installed on the cold water input side of your electrical instant water heater, when using at such places with a water pressure of 6 bars or more.
The hoses and pipes that are to be directly connected with the installation need to
sustain a working pressure of 6 bars.
Without a person who is responsible for the security of the devices and without providing necessary conditions for surveillance and management of the device, it is not intended to use that device by the people (including children) who is disabled physically or mentally and who has lack of experiance and knowledge about that product.
Children must be kept under supervision to be sure that they are not playing with the device. In order to deal all ports of trouble and breakdown and to provide spare parts definetely apply to Authorized Service.
DEFINITIONS AND SPECIFICATIONS 7 SECURITY SYSTEMS
1.The resistance of your appliance is a covered tube resistance and so the
resistance wire never tuoches with water. Thanks to this feature, the current electricity does not contact with the water and that prevents the electric shocks.
2.When the water flow is too low or there is no water, diaphragm switch cut off the
water heater’s power supply, if even your appliance is powered on.
3.When water is over heated, the thermostat which is within the heating reservoir
switches off to ensure absolute safety. If the water temperature comes to normal degrees, it switches again.
4.When any blockage at the water discharge of the appliance becomes, the return
system switches off your appliance, in order to prevent the sudden increases of the water temperature.
5.The security valve lying on the heating reservoir empties the over water flow and
thus prevents any damages of the user and the appliance.
6.Within the heating reservoir, where tube resistances were inserted, durably water
will become held and thus plastic accessories of the equipment are protected from damaging of losses water until they becomes cool.
7.Against the fact that the user is not to leave the appliance open was powered on,
there is an indicator light in front of it.
STEP INDICATOR SWITCH
(WATER TEMPERATURE SELECTION SWITCH)
This switch allows you to turn on and off your electrical instant water heater and to adjust your hot water level. The appliance has three steps including 3000 W, 4000 W, and 7000 W, whichever one you may desire to choose according to the water temperature.
0 - No heating 1 - 3000 W 2 - 4000 W 3 - 7000 W
INDICATOR LIGHTS
There are three indicator lights on your appliance, which indicate at which step in operates and whether there is any tension on it.
N-AUTOMATIC POWER SWITCH
N-Automatic power switch functions as the key, when set to position ‘’off’’ this power switch will automatically cut-off the connection of the instant water heater with power supply. This power switch is mountec to the appliance not to the fuse panel.
DIAPHRAGM SWITCH
When the water flow is low, it switches on automatically to cut off the water heater’s power supply and ensures the resumtion on the operation of water heater when the normal water flow returns.
SAFETY THERMOSTAT
When water is over – heated, the heater’s resistance switches off to ensure absolute safety.
TO BE DONE BY A QUALIFIED SERVICE
RESISTANCE TO WATER FLOW
Taking into account the main water flow of the city, your electrical instant water heater has been already subjected to a test under the water flow of 11 bars.
WATER HEATER’S MONTAGE ONTO THE WALL
Ensure that the wall to which you are to mount the appliance be of an even
surface.
Mark the places of nipples by using the montage pattern given with the appliance
Drill 4 places in which nipple can enter completely (8 mm)
Insert the nipple into the hole and turn the screw to a distance of 3 mm to the
nipple.
Montage the heater’s body by assembling screw through hanger seats.
ASSEMBLY OF SHOWER ACCESSORIES
In order to assemble your electrical instant water heater onto the place you deemed appropriate, drill two holes with a size that the nipples can easily enter (8 mm).
Fix the showhanger by using screws from holes to nipples.
Your showhanger is of rotating type, allowing you to arrange the position up and
down.
CONNECTING THE ELECTRICAL INSTANT WATER HEATER TO THE SHOWER ACCESSORIES
By using two spiral hoses supplied with your electrical instant water heater
connect the portable shower accessory to the electrical instant water heater, the ¾ ‘’ extremity of the other spiral hose to the accessory, and its ½ ‘’ extremity to the electrical instant water heater.
By using the rubber gaskets supplied with the accessory complete the couplings.
Never use any shower accessory of other appliance instead of this shower
accessory giving with your appliance.
ELECTRICAL LINKAGE
The working voltage range of your electrical instant water heater is 220 – 240
volts.
The power of your electrical instant water heater is 7000W. The internal
installation of the building ought to be arranged to conform a power of 7000W.
Grounding is absolutely necessary. The appliance should in no way be used in buildings that have no ground connection, inadequate ground connection or the ground connection is not convinient with rules. Otherwise, our company shall not be held responsable for any problems that may ensure.
The distance and tension loss of the electricity between the electrical panel of your entrance and the electrical instant water heater should be taken into account. A cable whose cross – section is at least 4 mm2 40 amperes should be used. (Reduc­tion factors are also to be taken into account.)
The electricity line of your appliance connected is distinct from the insurance panel of your home and the automatic fuse should be at 40 amperes. There must any plug, lamp or any other things in this line or if there is it must be cancelled. If it is not possible to draw a direct line for the water heater, if the current line within the building accordingly, a line which is on the next plug socket distributer (buat) is pulled to the bathroom. In this case the other plug sockets connected with the respective line are cancelled. The protection connected with this line should be at 40 amperes.
It is necessary to use the 3*4 mm2 of Antigron cabel if the current plant is not appropriate and the installment which has a standart grounding must be connected directly to the water.
If the main insurance vlue of your home is not enough, the main insurance should
be changed with new one which has proper value after calculation of the electrician.
Connection of ground and neotral line method which is called making zero, etc. İs
not acceptable for grounding and never connect to this type lines.
+ 14 hidden pages