www.king-electric.com
good - line voltage
EURO STYLE SINGLE OR DOUBLE POLE LINE VOLTAGE
UPC
#093319
Part#
Single Pole Euro Style
w/ Thermometer
Single Pole Euro Style
w/ Thermometer
Double Pole Euro Style
w/ Thermometer
Double Pole Euro Style
w/ Thermometer
K601 T
MODEL
K601 19157 Single Pole Euro Style Box (25 pieces) White 22 18 45°F - 75° F
K601A 19161 Single Pole Euro Style Almond 22 18 45°F - 75° F
K601T 19158
K601TR 19162
K602 19159 Double Pole Euro Style Box (25 pieces) White 22 18 45°F - 75° F
K602A 19164 Double Pole Euro Style Almond 22 18 45°F - 75° F
K602T 19160
K602TR 19163
* a master pack of 4 - 10 packs is available (40 units total)
TYPE PACKAGE COLOR
Box (25 pieces) White 22 18 45°F - 75° F
Clamshell*
(10 pieces)
Box (25 pieces) White 22 18 45°F - 75° F
Clamshell*
(10 pieces)
White 22 18 45°F - 75° F
White 22 18 45°F - 75° F
AMPS
120-240
AMPS
277
SERIES
TEMP.
RANGE
K602
These good thermostats have a
larger, more sensitive, bi-metal
sensor that improves temperature
accuracy to ±3°F. This feature
achieves a better comfort level
with a reduced temperature swing
as compared to economy models.
The rounded corners give a
modern appearance while the
large knob allows for easy
adjustment. The standard color
is white. Add (-T) for models that
include a room thermometer.
SPECIFICATIONS
Temperature Range:
45°F to 75°F (7°C to 24°C)
Temperature Default:
55°F or 68°F (13°C or 20°C)
Display: 5° increments
Rate: 2 cycles per hour
Accuracy: ±3°F
Power Source: 120 VAC,
208VAC - 240VAC,
277 VAC
50 - 60Hz
Dimensions:
FEATURES TECHNICAL
· Even temperature settings.
· Internal heater simulates room
heater warming up space.
· Rounded face gives modern
appearance.
· Single or double pole (positive
off) available.
· Optional thermometer on cover
shows temperature.
· White color with gray print.
· Fully vented cover allows air
sensing in all directions.
· Large knob allows easy
adjustment to all temperatures.
· 75°F (°24C) maximum setting
provides compliance with
some state energy codes, like
California’s Title 24.
· 22 Amps at 240V, 5,280 Watts.
· Three wire installation.
· Snap action switch.
· Flexible wire leads.
· 45° to 75°F (7°C to 24°C).
· Large bi-metal sensor.
· 120/208/240/277 Volts.
· New rounded styling.
· (T) - designates thermometer.
· For use on all types of electric
heaters, fan-forced, baseboard,
radiant, etc.
King Electrical Manufacturing Company / 9131 10th Avenue South, Seattle, WA 98108 / phone 206.762.0400 / fax 206.763.7738
www.king-electric.com
good – line voltage
EURO STYLE SINGLE OR DOUBLE POLE LINE VOLTAGE (CONTINUED)
INSTALLATION NOTES
This line voltage device should
be installed and serviced by
a qualified electrician. The
thermostat has been designed
to mount to a standard 2"X 4"
electrical outlet box. Leveling of
the thermostat is not required.
Mounting screws are provided.
Mount the thermostat about five
feet above the floor in an area
with good air circulation. Avoid
mounting the thermostat where it
will be affected by drafts, air from
ducts and radiant heat sources
such as appliances, the sun,
lamps or hot water pipes.
K601 K602
L1 L2
RED
THERMOSTAT
BLACK
HEATER
UP TO 5280 WATTS
WIRING DIAGRAM
BLACK
L1 L2
RED
THERMOSTAT
BLACK
HEATER
UP TO 5280 WATTS
RED
ON / OFF
SWITCH
SERIES
· After about 7 years thermostats
are not as accurate. Replacing
them with a new anticipated
model will reduce the
temperature swings that are
common with older thermostats.
·Thermostats should be mounted
on an inside wall for best
performance.
· Mounting a thermostat above a
fan wall heater will not hinder
the performance of a high
quality thermostat.
· Keep lamps or any other forms
of heat (like in-wall hot water
pipes or the sun) away from the
thermostat location for the most
accurate control of a zone or space.
CALIBRATION ADJUSTMENTS
Thermometer Cover
Turn nut to adjust thermometer
HE-1 & K601
Single Pole
K601 calibration screw
Adjust calibration here
(3/32" hex allen wrench required)
HE-2 & K602
Double Pole
ON / OFF Switch
TO CHANGE CALIBRATION:
•
3/32" hex allen wrench required
• CLOCKWISE to DECREASE
maximum temperature setting
of dial
• COUNTERCLOCKWISE to
INCREASE maximum temperature
setting of dial
• To prevent unwanted movement
of calibration screw once set,
place a drop of fingernail polish
or glue on screw.
Note: Overtightening of mounting
screws can twist base and alter
calibration. To solve this loosen
mounting screws.
King Electrical Manufacturing Company / 9131 10th Avenue South, Seattle, WA 98108 / phone 206.762.0400 / fax 206.763.7738