KING HE User Manual

www.king-electric.com
better – line voltage
EURO STYLE ANTICIPATED SINGLE OR DOUBLE POLE LINE VOLTAGE
UPC
HET-1
HE-1
HE-1A
HET-1
HE-2
HE-2A
HET-2
#093319
PART #
19063
19064
19069
19070
19066
19067
19071
19072
19166
MODEL
HET-1R
HET-2R
HE-2-25
* a master pack of 4 - 10 packs is available (40 units total)
TYPE
Euro Style, Anticipated
Euro Style, Anticipated
Euro Style, Anticipated
w/ thermometer
Euro Style, Anticipated
w/ thermometer
Euro Style, Anticipated
Euro Style, Anticipated
Euro Style, Anticipated
w/ thermometer
Euro Style, Anticipated
w/ thermometer
Euro Style, Anticipated
POLES
Single
Single
Single
Single
Double
Double
Double
Double
Double
PACKAGING
Box (50 pieces)
Box (50 pieces)
Box (50 pieces)
Clamshell* (10 pieces)
Box (50 pieces)
Box (50 pieces)
Box (50 pieces)
Clamshell*
(10 pieces)
Box (50 pieces)
COLOR
White
Almond
White
White
White
Almond
White
White
White
SERIES
AMPS
AMPS
120-
277
240
22 55°F - 85° F
18
22
18
22
18
22
18
22
18
22
18
22
18
22
18
25
22
TEMP.
RANGE
55°F - 85° F
55°F - 85° F
55°F - 85° F
55°F - 85° F
55°F - 85° F
55°F - 85° F
55°F - 85° F
55°F - 85° F
HE-2
These better thermostats have a larger, more sensitive, bi-metal sensor that improves temperature accuracy to ±1½°F. You will achieve a better comfort level with a reduced temperature swing as compared to economy models. The rounded corners give a modern appearance while the large knob allows for easy adjustment. The standard color is white with limited models in almond (-A). Add (-T) for models that include a room thermometer.
SPECIFICATIONS
Temperature Range:
°F to 85°F (13°C to 29°C)
55
Display: 5° increments Rate: 2 cycles per hour Accuracy: ±1½°F Power Source: 120 VAC,
208VAC - 240VAC, 277 VAC 50 - 60Hz
Dimensions:
FEATURES
·
Save up to 10% on heating costs.
· Even temperature settings.
· Internal heater simulates room heater warming up space.
· Faster cycle rate reduces temperature swings.
· Rounded face gives modern appearance.
·
Complies with all energy codes requiring anticipated thermostats.
· Single or double pole (positive off) available.
· Optional thermometer on cover shows temperature.
· White color with gray print.
· Fully vented cover allows air sensing in all directions.
· Large knob allows easy adjustment to all temperatures.
·
85°F (29°C) maximum setting provides compliance with some state energy codes, like California’s Title 24.
TECHNICAL
· 22 Amps at 240V, 5,280 Watts.
· Three wire installation.
· Snap action switch.
· Flexible wire leads.
·
55° to 85°F (
· Anticipated (resistor style).
· Large bi-metal sensor.
· 120/208/240/277 Volts.
· New rounded styling.
· (T) - designates thermometer.
· Meets most energy codes
· ±2°.
· For use on all types of electric heaters, fan-forced, baseboard, radiant, etc.
13°C - 29°C).
King Electrical Manufacturing Company / 9131 10th Avenue South, Seattle, WA 98108 / phone 206.762.0400 / fax 206.763.7738
www.king-electric.com
better – line voltage
EURO STYLE ANTICIPATED SINGLE OR DOUBLE POLE LINE VOLTAGE (CONTINUED)
WIRING DIAGRAM
HE-1 / HE-1-25 HE-2 / HE-2-25
(RESISTOR)
UP TO 5280 WATTS UP TO 5280 WATTS
INSTALLATION
This line voltage device should be installed and serviced by a qualified electrician. The thermostat has been designed to mount to a standard 2" X 4" electrical outlet box. Leveling of the thermostat is not required. Mounting screws are provided. Mount the thermostat about five feet above the floor in an area with good air circulation. Avoid mounting the thermostat where it will be affected by drafts, air from ducts, and radiant heat sources such as appliances, the sun, lamps or hot water pipes.
SERIES
NOTES
· After about 7 years thermostats will not be as accurate as when they were new. Replacing them with a new anticipated model will reduce the temperature swings that are common with older stats.
· Thermostats should be mounted on an inside wall for best performance.
· Mounting above a fan wall heater will not hinder the performance of a high quality thermostat.
· Keep lamps or any other form of heat (such as in-wall hot water pipes or the sun) away from the thermostat location for the most accurate control of a zone or space.
King Electrical Manufacturing Company / 9131 10th Avenue South, Seattle, WA 98108 / phone 206.762.0400 / fax 206.763.7738