KING DS-8 User Manual

LIMITED WARRANTY
The DS-8 is warranted against defects in workmanship and materials for two years from date of sale. This warranty does not apply to damage resulting from accident, misuse, or alteration nor where connected voltage is more than 5% above the configured operating voltage, nor to equipment improperly installed or wired or maintained in violation of this Owner’s Manual. No other written or oral warranty applies. No employee, agent, dealer or other person is authorized to give any warranties on behalf of ASE.
AUTOMATED SYSTEMS ENGINEERING, INC. 2519 E SAINT VRAIN ST COLORADO SPRINGS, COLORADO 80909 PHONE: 719.599.7477 FAX: 719.599.7482
Visit us on the Internet at: www.goase.com
CAUTION: Read all instructions carefully before installation. Save this Installation Manual for future reference.
DS-8
RAIN/SNOW SENSOR CONTROLLER
INSTALLATION MANUAL
R
T
E
E
T
K
N
AUTOMATED SYSTEMS ENGINEERING
ENCLOSURE TYPE 3R
RAIN/SNOW SENSOR CONTROLLER
CONFORMS TO UL STD 508 CERTIFIED TO CAN/CSA STD C22.2 NO. 14
INPUT 100−120V AC 0.15 A 50/60 Hz 200−240V AC 0.15 A 50/60 Hz
CONTROL 30 A 240V AC, 20 A 30V DC
THIS UNIT MAY BE SUPPLIED BY MORE THAN ONE BREAKER
DS−8
DANGER
CAUTION
I
CM
US
C
L
I
D
S
E
T
3175102
INDICATOR
OFF
CONTROL SWITCH
MANUAL ON AUTOMATIC STANDBY/RESET
TRIGON
Manufactured By
AUTOMATED SYSTEMS ENGINEERING
2519 East Saint Vrain St Colorado Springs, Colorado 80909
General Safety Instructions
1. THIS UNIT SHOULD BE INSTALLED, OPENED, AND REPAIRED BY QUALIFIED PERSONNEL
ONLY!
CETTE UNITÉ DEVRAIT ÊTRE INSTALLÉE, OUVERTE, ET RÉPARÉE PAR LE PERSONNEL
QUALIFIÉ SEULEMENT!
2. To avoid shock hazard do not open the front cover with power connected to the DS-2B or any controlled
equipment.
Pour éviter la décharge électrique déconnectez toute la puissance avant d'ouvrir la couverture du DS-
2B.
3. To avoid fire hazard replace fuse F1 with a 1/2 Amp 250 VAC 2AG fast acting fuse ONLY. Pour éviter le risque d'incendie remplacez le fusible F1 par un fusible de 1/2 l'ampère 250 VCA 2AG
SEULEMENT.
INPUT POWER
VOLTAGE SELECT
TEMP ADJUST
DELAY ADJUST
LOAD
PROBE JACK
LED JACK
SWITCH JACK
C&M JACK
SENSOR TERMINAL BLOCK
Setting the Adjustments
The DS-8 is specifically designed for snow and freezing rain detection only. This section explains the functions of the adjustments. Trigger temperature is adjustable from 34°F (1.1°C) - 44°F (6.6°C) using the temperature adjust (TEMP) control. When ambient air temperature is below this trigger point precipitation is assumed to be snow or freezing rain. When above the trigger temperature, precipitation is assumed to be rain and the sensor will not trigger.
Detecting Both Rain & Snow
The DS-8 is designed primarily for snow detection but it is possible to trigger the unit on detection of any precipitation. Unplugging the temperature probe from the probe jack will simulate continuous freezing temperature detection. Any precipitation, rain or snow, which lands on the moisture sensor will trigger the unit, no matter what the ambient temperature may be. Note, however, that the unit cannot be configured for detection of rain only. Consider the DS-2B or DS-824 for this application.
Moisture Grid Maintenance & Replacement
It is recommended that the DS-8 be powered down and the grid wiped clean with clear water at least once every 4 months. Heavy depos its may be removed using a non-metallic scouring pad (Scotch-
TM
or equivalent.) However, after a number of years, the corrosive elements left behind when
Brite water is evaporated out of the moisture grid will eventually damage the grid rings. The moisture grid can be easily replaced by ordering and installing a new MG-3 “Moisture Grid Assembly” . Reference the “Moisture Sensor Mounting & Termination” section for information on replacing the moisture grid.
Preseason Testing
It is always a good idea to test the operation of the DS-8 prior to the winter season. Procure some clean water and, if the outdoor temperature is above the trigger point, a can of spray component cooler (Radio Shack Part #64-4321 or equivalent.) Clean the moisture grid following the procedure outlined above and allow it to dry. Apply power to the DS-8 and confirm that the lamp shows a steady indication. Drip some of the water onto the moisture grid, and then spray the temperature sensor protruding from the base of the DS-8 enclosure with the component cooler. Once the temperature sensor has reached the trigger point with water still present on the grid the DS-8 will activate. The user should hear the internal control relay close and the indicator will begin flashing. Proper operation has now been confirmed. To clear the Delay-Off timer place the override switch into “Standby/Reset”, and then back to “Automatic.”
Need Indoor Monitoring & Control?
Take a Look at the ASE CDP-2
"Delay Off" refers to the drying cycle timer of the DS-8. The timer allows the DS-8 to dry the heated surface through evaporation once precipitation has stopped. The drying cycle reduces the chance of moisture left behind refreezing into ice. This timer is restarted by each precipitation detection. Therefore, the DS-8 will continue to operate as
long as precipitation is detected, then for the Delay Off period once precipitation has stopped. The Delay Off time can be adjusted from 30-90 minutes using the delay adjust (DEL) control. Note the “Manual On” function at the low end of the Delay Adjust control. The relay will close when this area is entered and open when exited.
2
Simple Installation & Operation at a Competitive Price
Visit www.goase.com for more information
7