KING Capilary Tube Thermostat User Manual

www.king-electric.com
in-built line voltage
CAPILLARY TUBE STYLE
THREE WIRE
TWO WIRE single pole
maximum temperature 105° F
Part # 275-2822-00
C1-25
SERIES
KB
single pole
maximum temperature 107° F
Part # 275-5011-00
C1-25
SERIES
LPW
SERIES
ELECTRICAL RATING CHART
VOLTS
120
208
240
277
WATTS
3000
5200
6000
6925
AMPS
25
25
25
22
SPECIFICATIONS
Control Range: 40°F to 90°F (4°C - 32°C) Power Source: 125 VAC 240 VAC 277 VAC Switch Action: Single Pole, Single Throw, make on temperature rise
Differential: 2°F Ratings: Non-inductive
25 Amps @ 120VAC 25 Amps @ 240 VAC
Mounting: 6-32 threaded holes on 1 5/16" (33mm) centers Shaft: Type 1 (clockwise to raise temperature setting) Sensor: Liquid-filled capillary and bulb Capillary length: 3 wire: 4 1/16" 2 wire: 3½" Bulb diameter: 3 wire: 5/16" 2 wire: ¼"
Weight: .3 lbs/.14kg (single pole) Lead Wires: 125°C 14AWG UL File: E16835
DESIGN FEATURE SPECIFICATIONS
SNAP ACTION SWITCHING: Instant, positive response. No arcing. No burning of contacts, to shorten switch life. No TV snow, no radio static. Enclosed for protection against dirt and corrosion.
1 5/16"
KCC
KC
KCF
KFUH
KBP
LIQUID-FILLED SENSING ELEMENT: This extra sensitive remote capillary bulb dependably and accurately registers the slightest temperature change instantly.
VENTED FRAME: Top and bottom to maintain normal temperature in outlet box.
AIR PASSAGE: No obstruction of air across bi-metal sensor.
1 5/16"
FACTORY SEALED and CALIBRATED: Engineered for accurate, dependable performance. Field adjustment not required.
ENCLOSED TERMINALS: To prevent contact with grounded faces.
RATING: 25 Amps continuous at 120, 208, 240 Volts AC. Non-inductive.
22 Amps continuous at 277 Volts AC. Non-inductive.
MAXIMUM RANGE: 40° to 117°F (4°C - 47°C)
AVERAGE DIFFERENTIAL: Approximately 5°F at 50% of rated load.
CYCLE RATE: Approximately 2 - 4 per hour at 50% of rated load.
King Electrical Manufacturing Company / 9131 10th Avenue South, Seattle, WA 98108 / phone 206.762.0400 / fax 206.763.7738