Thank you for buying your Kinetik Bluetooth Blood Pressure Monitor. Whether you
have already been diagnosed with high blood pressure or want to track any changes to
your blood pressure, you have taken the first step to a quick, easy and accurate device
that will keep you and, if necessary, a doctor informed.
• Accurate – with irregular heartbeat detector to ensure correct measurement
• Easy to use – fully automatic, works at the push of a button.
• Easy to read – large LCD display.
• Convenient – pair via Bluetooth 4.0 with your phone or tablet to record readings
• Suitable for two users
Before you start, it is important that you read this manual carefully. Blood pressure
testing is easy but to make sure you have the most accurate readings, it is important to
follow the instructions. Please keep them in a safe place in case you need to refer back
to them at a later date.
If you have any concerns about your blood pressure in anyway, we recommend you
contact your doctor.
Usage
The Kinetik Bluetooth Blood Pressure Monitor is intended for use in
measuring blood pressure and heartbeat rate with arm circumference ranging
from 22cm to 42cm(about 8¾˝-16½˝).
It is intended for adult use only.
Safety Information
The signs below will be in the user manual, labeling or other components.
They are the requirement of standards and usage.
Symbol for “THE OPERATION
GUIDE MUST BE READ”
symbol colours are white on
a blue background).
Symbol for “COMPLIES WITH
MDD 93/42/EEC REQUIREMENTS”
0197
Symbol for “MANUFACTURER”
Symbol for “SERIAL NUMBER”
Symbol for “DIRECT CURRENT”
Symbol for “MANUFACTURE
DATE”
Protection against ingress of
IP21
water
(actual
CAUTION
The device is not suitable for measuring the blood pressure of children. Ask your
doctor before using it on older children.
The device is not suitable for use on pregnant women, patients with implanted,
electronic devices, patients with pre-elcampsia, premature ventricular heartbeats, atrial
fibrillation, peripheral, arterial disease and patients who have undergone intravascular
therapy or arterio venous shunt or people who received a mastectomy. Please consult
your doctor prior to using the unit if you are unsure.
Do not take any therapeutic measures on the basis of a self measurement. Never alter
the dose of a medicine prescribed by a doctor. Consult your doctor if you have any
question about your blood pressure.
Please keep the unit out of reach of infants, children or pets, since inhalation or
swallowing of small parts is dangerous or even fatal.
Symbol for “TYPE BF APPLIED
PARTS”
Symbol for “ENVIRONMENT
PROTECTION - Electrical waste
products should not be disposed of
with household waste. Please recycle
where facilities exist. Check with your
local authority or retailer for recycling
advice”
Symbol for “Authorised Representative
EC REP
in the European Community
Symbol for “Including RF
transmitter”
Caution: These notes must be
observed to prevent any damage
to the device.
2
3
ME
M
S
ET
S
TA
R
T
S
TOP
M
E
M
S
E
T
S
T
A
R
T
S
T
O
P
INTRODUCTION
INTRODUCTION
CAUTION
This device is intended only for adult use only.
This device is intended for non-invasive measuring and monitoring of arterial blood pressure. It is
not intended for use on extremities other than arm or for functions other than obtaining a blood
pressure measurement.
If you experience discomfort during a measurement, such as pain in the arm or other complaints,
press the START/STOP button to release the air immediately from the cuff. Loosen the cuff and
remove it from your arm.
On the rare occasion of a fault causing the cuff to remain fully inflated during measurement, open
the cuff immediately. Prolonged high pressure (cuff pressure >300mmHg or constant pressure
>15mmHg for more than 3 minutes) applied to the arm may lead to an ecchymosis.
Too frequent and consecutive measurements could cause disturbances in blood circulation and
injuries.
Do not wrap the cuff on the same arm which other monitoring medical electrical equipment is
applied simultaneously, this could cause temporary loss of function of those simultaneously-used
monitoring medical electrical equipment.
Don’t kink the connection tube during use, as the cuff pressure may continuously increase which
can prevent blood flow and result in harmful injury to the PATIENT.
The equipment is not AP/APG equipment and not suitable for use in the presence of a flammable
anaesthetic mixture with air of with oxygen or nitrous oxide.
This unit is not suitable for continuous monitoring during medical emergencies or operations.
This device cannot be used with HF surgical equipment at the same time.
To avoid measurement errors, please avoid strong electromagnetic field radiated interference signal
or electrical fast transient/burst signal.
The operator shall not touch output of batteries/adapter and the patient simultaneously.
The materials of the cuff have been tested and found to comply with requirements of ISO
10993-5:2009 and ISO 10993-10:2010. It will not cause any potential sensization or irritation
reaction. Never apply the cuff over damaged skin.
Do not use the unit in case of existing polyester resp. synthetic allergies.
Be careful to strangulation due to cables and hoses, particularly due to excessive length.
Do not connect the air hose to other medical equipment, as this could cause air to be pumped into
intravascular systems or high pressure, what could lead to dangerous injuries.
Before use, make sure the device functions safely and is in proper working condition.
Please use the device under the environment which was provided in the user manual. Otherwise,
the performance and lifetime of the device will been impacted and reduced.
Please use ACCESSORIES and detachable parts specified/ authorised by the Manufacturer. This
may cause damage to the unit or danger to the user/patients.
Please dispose of ACCESSORIES, detachable parts, and the medical electrical equipment
according to the local guidelines.
Please do not attempt to repair the unit yourself in the event of malfunctions. Only have repairs
carried out by authorised service centres.
Please report to Manufacturer if any unexpected operation or events occur.
This Blood Pressure Monitor is calibrated at the time of manufacture. If the Blood Pressure Monitor
is used according to the instructions, periodic re-calibration is not required.
Please use a soft cloth to clean the whole unit. Don’t use any abrasive or volatile cleaners.
Monitor Components
LCD DISPLAY
AIR HOSE
MEM BUTTON
START/STOP BUTTON
Component list of pressure
measuring system
1 Cuff
2 Air pipe
3 Pump
4 Valve
List
1.Blood Pressure Monitor
(BPM100)
MEM
START
STOP
SET
3. 4×AAA batteries
LOCK BUTTON
MEM
START
STOP
SET
BATTERY COMPARTMENT
DC POWER SOCKET
2.Cuff (Type BF applied part)
(22cm~42cm)
(Please use Kinetik
authorised cuff. For the size
of the actual cuff please
refer to the label on the
attached cuff.)
4.User manual
CUFF
SET BUTTON
AIR CONNECTOR PLUG
4
5
INTRODUCTIONINTRODUCTION
Understanding the Symbols on your
Blood Pressure Monitor
6
SYMBOLDESCRIPTION
Systolic blood pressure High pressure result
Diastolic blood pressure Low pressure result
Pulse per minuteBeats per minute, BPM
Average value
Memory
kPa
mmHg
Low battery
Irregular heartbeat
Grade
Current Time
HourThe hour in the clock mode
Minute
Second
Heartbeat
User 1
User 2
Bluetooth icon
EXPLANATION
The average value of the latest three
records
The displayed measurement values
from the memory.
Measurement Unit of the blood pressure
(1kPa=7.5mmHg)
Measurement Unit of the blood pressure
(1mmHg=0.133kPa)
Batteries are low and need to be replaced
Irregular heartbeat Detection
The grade of the blood pressure
Year/Month/Day(M/D or D/M),
Hour/Minute
ErrorError
The minute in the clock mode
The second in the clock mode
Heartbeat detection during the
measurement
Start measurement,save and transmit the
measuring results for User 1
Start measurement,save and transmit the
measuring results for User 2
The bluetooth icon blinks when the
bluetooth is working