KineticoPRO M20-S Specifications

Ver. I, Aug 2010 JN
Filter Media
Scale Inhibitor
polypropylene
Model
Maximum Dimensions
Micron Rating
Initial ΔP (psi) at Flow Rate (gpm)*
Scale Control Capacity at Flow rate (gpm)*
Temperature Rating
M20-S
18.5” x 7” x 30”
5
5 psi @ 5 gpm
40,000 gallons @ 5 gpm 151,400 liters @ 18.9 Lpm
40°F to 100°F
Cartridge Specifications and Performance Data
Materials of Construction
Features:
Siliphos
Benefits:
Reduce pitting of stainless steel
ice machine components
Inhibits Scale Build-up
Specified to:
Inhibit Scale build-up
Reduce sediment at 5 Micron
Applications:
Ice Machine Applications
M20-S with Siliphos hardware has been independently tested against NSF/ANSI Std. 42 Do not use with water that is microbiologically unsafe or of unknown quality
3980 Lakefield Court Suwanee, GA 30024 USA
P: 678-475-0799 800-635-4017 F: 678-475-9126 800-811-7682
www.selectoinc.com
System Part #: 02-260 Replacement Part #: 101-233 101-260