WARNING
This appliance has a naked flame and as with all heating appliances a fireguard should be
used for the protection of children, the elderly and infirm. Fireguards should conform to BS
6539 (1984) (Fireguards for use with solid fuel appliances).
Servicing should be carried out annually by a competent person such as a CORGI
registered engineer. It is a condition of CFM Kinder ltd three year and lifetime guarantees
that this is carried out by a competent person i.e a CORGI registered Engineer in
accordance with these servicing notes
For continued safe operation of the spillage monitoring system the oxy-pilot assembly must
be replaced at the annual service.
These are available from
CFM
Kinder Ltd at a specially
discounted price to encourage routine renewal and ensure continued safe and trouble free
operation of the spillage monitoring system. Pilot renewal is also a condition of the above
guarantee schemes.
The service should include visually checking the chimney and fire opening for accumulations of
debris and a smoke test to check for a positive up-draught in the chimney.
The condition of the coals should be checked and
if necessary the whole set should be
replaced with a genuine replacement set.
The burner assembly is designed to be removed as a complete unit for ease of access.
After any servicing work a gas soundness check and spillage test must always be carried
out.
Rubbish of any type must NEVER be thrown onto the fuel bed, this could affect safe operation and
damage the fire.
Any debris or deposits should be removed from the fuel bed from time to time.This may be carried
out by referring to the cleaning section as described later in this book.
Only the correct number and type of coals must be used and only complete and genuine
replacement sets must be used.
Always keep furniture and combustible materials well clear of the fire and never dry clothing or
items either on or near to the fire. Never use aerosols or flammable cleaning products near to the
fire when it is in use.
The hard ceramic fuel bed remains hot for a considerable period after use and sufficient
time should be allowed for the fire to cool before cleaning etc.
The fire must only be operated with the brass fender and ash pan cover as supplied with the fire
and these must always be in position when the fire is used.
57832