Kinder Fires KF 130T, KF 140T User Instructions

Kinder Fires
Oasis RC
&
HLS
Model No. KF 130T
KF 140T
DECORATIVE COAL EFFECT GAS FIRE
G.BI
I.E.
57832
It is the law that all gas appliances are installed only by a competent (e.g. CORGI Registered) Installer, in accordance with the installation instructions and the Gas Safety (Installation and Use) Regulations 1994 as amended. Failure to install appliances correctly could lead to prosecution. It is in your own interest and that of safety to comply with the law.
The fire may be fitted below a combustible shelf provided that the shelf is at least 150mm above the top of the appliance and the depth of the shelf does not exceed 150mm.
The fire may be installed below combustible shelves which exceed 150mm deep providing that the clearance above the fire is increased by 15mm for each 25mm of additional overhang in excess of
150mm.
No additional purpose made additional ventilation is required for this appliance when installed in G.B. please consult document I.S. 813:1996 Domestic gas installation, as issued by the National
standards Authority of ireland, for use in Northern Ireland, please refer to local building
regulations.
If the chimney or flue has been previously used by appliances burning fuels other than gas they must be swept prior to the installation of this fire.
If this appliance is fitted directly on to a wall without the use of a fireplace or surround. All combustible material must be removed from behind the trim. Soft wall coverings such as wallpaper, blown vinyl etc. could be affected by the heat and may discolour or scorch. This should be considered when installing or decorating.
CFM Kinder Limited Trentham Lakes
Stoke on Trent
Staffs
ST44TJ
57832
The Kinder Oasis fuel effect gas fire incorporates a unique and highly developed fuel bed which gives the realism of a loose coal layout combined with realistic flames and glow. The use of durable hard ceramic material in the construction of the fuel bed components ensures long and trouble free operation.
The fire incorporates a flame control which allows you to adjust the flame appearance to give the
desired combination of flames and glow.
When first using the new fire a slight smell may be noticed. This is due to starch used in the
manufacture of the soft ceramic coals, it is non-toxic and will soon disappear.
Please take the time to fully read these instructions as you will then be able to obtain the most effective and safe operation of your fire. See below for a guide to the main parts and controls of your fire.
Front Ceramic
Support
Front Ceramic Locating Lug
Pilot Assy
Fuelbed Base Plate
Pressure Test Point
Burner Heat Shield
Aeration Lever
Remote sensor bracket
57832
WARNING This appliance has a naked flame and as with all heating appliances a fireguard should be
used for the protection of children, the elderly and infirm. Fireguards should conform to BS 6539 (1984) (Fireguards for use with solid fuel appliances).
Servicing should be carried out annually by a competent person such as a CORGI
registered engineer. It is a condition of CFM Kinder ltd three year and lifetime guarantees that this is carried out by a competent person i.e a CORGI registered Engineer in accordance with these servicing notes
For continued safe operation of the spillage monitoring system the oxy-pilot assembly must
be replaced at the annual service.
These are available from
CFM
Kinder Ltd at a specially discounted price to encourage routine renewal and ensure continued safe and trouble free operation of the spillage monitoring system. Pilot renewal is also a condition of the above guarantee schemes.
The service should include visually checking the chimney and fire opening for accumulations of
debris and a smoke test to check for a positive up-draught in the chimney. The condition of the coals should be checked and
if necessary the whole set should be replaced with a genuine replacement set. The burner assembly is designed to be removed as a complete unit for ease of access. After any servicing work a gas soundness check and spillage test must always be carried
out.
Rubbish of any type must NEVER be thrown onto the fuel bed, this could affect safe operation and damage the fire.
Any debris or deposits should be removed from the fuel bed from time to time.This may be carried out by referring to the cleaning section as described later in this book.
Only the correct number and type of coals must be used and only complete and genuine
replacement sets must be used.
Always keep furniture and combustible materials well clear of the fire and never dry clothing or
items either on or near to the fire. Never use aerosols or flammable cleaning products near to the
fire when it is in use.
The hard ceramic fuel bed remains hot for a considerable period after use and sufficient time should be allowed for the fire to cool before cleaning etc.
The fire must only be operated with the brass fender and ash pan cover as supplied with the fire
and these must always be in position when the fire is used.
57832