MANUAL MOTOR STARTING SWITCHES
XSD, XSX, Series
Non Factory Sealed
FEATURES-SPECIFICATIONS
Applications
• Provides manual starting and stopping of
small AC or DC motors
• Motor running protection when overload
heaters are used
• XSX/FXSX Series (without overload
protection) are ideally suited for acrossthe-line applications where a positive
disconnect means is required
Features
• FXSX-FXSD Series require no external
seals (factory sealed) and are NEMA 3
(raintight) rated
• Enclosures are cast copper-free aluminum
alloy
• Operating shaft is stainless steel
• Multiple gang assemblies available in
combination with pilot lights, pushbuttons
and switches on request
• Ground flange joint between bolted cover
and box provide required flame path
• Provisions for padlocking switch in either
“ON” or ”OFF” position is standard
Dimensions
For dimensional data, see page S14.
XSD/XSX/FXSD/FXSX SERIES
Class I, Div. 1 & 2, Groups C, D
Class 1, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E, F, G
Class Ill
NEMA 7 (C, D) 9 (E, F, G)
NEMA 3 (Factory sealed type)
- File E5 336 0 and/or E12379
Certified - File LR11714
FXSD, FXSX Series
Factory Sealed
XSD/FXSD SERIES WITH OVERLOAD PROTECTIONj
Non-Factory Sealed:
Square D, Class 2510, Type F
1-Pole, 1HP, 115-230 VAC
2-Pole, 1HP, 115-230 VAC
3/4 HP, 115-230 VDC
XSD SINGLE GANG
CATALOG NUMBER
1-POLE
SINGLE
PHASE
XSD -11 XSD -12
XSD-21 XSD-22 3/4”
XSD-41 XSD-42
XSD-51 XSD-52 3/4”
XSD-01 XSD-02 Cover and Switch assembly
j Order heaters separately on page S13.
2-POLE
SINGLE
PHASE
HUB ST YLE HUB SIZE
Dead end
Feed thru
1/2”
1/2”
XSX/FXSX SERIES WITHOUT OVERLOAD PROTECTION
Non-Factory Sealed:
Square D, Class 2510, Type K
2-Pole, 2 HP, 115 VAC
2 HP, 200-230 VAC
3 HP, 460-575 VAC
3-Pole, 2 HP, 115 VAC
7-1/2 HP, 200-230 VAC
10 HP, 460-575 VAC
FM – File 25219
See files for details or call Killark.
Factory Sealed:
Square D, Class 2510, Type F
1-Pole, 1HP, 115-230 VAC
2-Pole, 1HP, 115-230 VAC
3/4 HP, 115-230 VDC
FXSD SINGLE GANG
CATALOG NUMBER
1-POLE
SINGLE
PHASE
FXSD11 FXSD12
FXSD21 FXSD22 3/4”
FXSD41 FXSD42
FXSD51 FXSD52 3/4”
FXSD01 FXSD02 Cover and Switch assembly
2-POLE
SINGLE
PHASE
HUB ST YLE HUB SIZE
Dead end
Feed thru
Factory Sealed:
Square D, Class 2510, Type K
2-Pole, 2 HP, 115 VAC
2 HP, 200-230 VAC
3 HP, 460-575 VAC
3-Pole, 2 HP, 115 VAC
3 HP, 200-230 VAC
5 HP, 460-575 VAC
1/2”
1/2”
T
T
R
E
R
E
R
R
A
A
T
T
S
S
S
S
m
H
H
C
C
A
A
O
O
Z
Z
L
L
XSX SINGLE GANGk
CATALOG NUMBER
2-POLE
30A., 250V
20A., 600V
1-PH ASE
XSX-12 XSX-13
XSX-22 XSX-23 3/4”
XSX-42 XSX-43
XSX-52 XSX-53 3/4”
XSX-2 XSX-3 Cover and Switch assembl y
k FM and CSA only
3-POLE
30A., 250V
20A., 600V
3-PHASE
HUB ST YLE HUB SIZE
Dead end
Feed thru
1/2”
1/2”
FXSX SINGLE GANG
CATALOG NUMBER
2-POLE
30A., 250V
20A., 600V
1-PH ASE
FXSX12 FXSX13
FXSX22 FXSX23 3/4”
FXSX42 FXSX43
FXSX52 FXSX53 3/4”
FXSX02 FXSX03 Cover and Switch assembly
3-POLE
30A., 250V
20A., 600V
3-PHASE
HUB ST YLE HUB SIZE
Dead end
Feed thru
1/2”
1/2”
T
T
R
E
R
E
R
R
A
A
T
T
S
S
S
S
m
H
H
A
A
Z
Z
XSD/XSX/FXSD/FXSX SERIES
C
C
O
O
L
L
HEATER TABLEj
CATALOG
NUMBER
YOSD-A.49 0.41-0.44 A.49
YOSD-A.54 0.45-0.49 A.54 A.54
YOSD-A.59 0.50-0.53 A.59
YOSD-A.65 0.54-0.58 A.65
YOSD-A.71 0.59-0.65 A.71
YOSD-A.78 0.66-0.71 A.78
YOSD-A.86 0.72-0.78 A.86
YOSD-A.95 0.79-0.85 A.95
YOSD- A1.0 2 0.86-0.96 A1.02
YO SD- A1.16 0.97-1.0 4 A1.16
YOSD- A1.25 1.05 -1.16 A1. 25
YOSD- A1.3 9 1.17-1.29 A1.39
YOSD- A1.5 4 1.30 -1.3 7 A1.54
YOSD- A1.6 3 1.38-1.47 A1.6 3
YOSD-A1.75 1.48-1.5 6 A1.75
YOSD- A1.8 6 1.57-1.6 5 A1. 86
YOSD- A1.9 9 1.66-1.79 A1. 99
YO SD- A2.15 1.80 -1.95 A2.15
YOSD-A2.31 1.96-2.15 A2.31
YOSD-A2.57 2.16-2.38 A2.57
YOSD-A2.81 2.39-2.75 A2.81
YOSD-A3.61 2.76-2.84 A3.61
YOSD-A3.95 2.85-3.06 A3.95
YOSD-A4.32 3.07-3.45 A4.32
YOSD-A4.79 3.46-3.70 A 4.79
YOSD-A5.30 3.71- 4.07 A5.30
YOS D-A5.7 8 4.08-4.32 A5.78
YOSD-A6.20 4.33-4.90 A6.20
YOSD-A6.99 4.91-5.35 A6.99
YO SD-A 7.6 5 5.36-5.85 A7. 65
YOSD-A8.38 5.86-6.41 A8.38
YOSD-A9.25 6.42-6.79 A9.25
YOSD-A9.85 6.80-7.57 A9.85
YOSD- A11.0 7. 58 -8.15 A11.0
YOSD- A11.9 8.16-8.98 A11.9
YOSD-A13.2 8.99-9.67 A13.2
YO SD- A14.1 9.68-9.95 A14 .1
YOSD-A14.8 9.96-10.8 A14. 8
YOSD-A16.2 10.9-12.1 A16.2
YO SD-A17.9 12.2 -13.1 A17.9
YOSD -A19.8 13.2-13.9
YOSD- A21.3 14.0-15.0 A 21.3
YOSD-A25.2 15.1-16 .0 A25.2
j Overload heaters are not supplied as part of the
starter assemblies and need to be ordered as
separate items by catalog number and priced
accordingly.
FULL-LOAD
MOTOR
CURRENT
SQUARE D
HEATER
CATALOG
NUMBER
A19.8
XSD / XSX / FXSD / FXSX HEATERS
FEATURES-SPECIFICATIONS
XSD/XSX NON-FACTORY SEALED DIMENSIONS
BOX ST YLE HUB SIZE A B D G
Single gang
dead-end
Single gang
feed-thru
Factory Sealed (FXSD/FXSX)
1/2” 5-1/4”(133) 2-1/4”(57) — 11/16”(17)
3/4” 5-1/4”(133) 2-1/4”(57) — 11/16”(17)
1” 5-3/8”(136) 2-3/8”(60) — 7/8”(22)
1/2” 5-1/4”(133) 2-1/4”(57) 6”(152) 11/ 16”(17 )
3/4” 5-1/4”(133) 2-1/4”(57) 6”(152) 11/ 16”(17 )
1” 5-3/8”(136) 2-3/8”(60) 6 ”(152) 7/8”(22)