CERTILITE® VEQ Emergency Lighting
fixtures provide continuous illumination
under normal power and switch to
emergency battery backup during power
outages. Emergency Units ONLY are
available that operate only when normal
power fails.
Units contain battery unit(s) that provides
the OSHA required 90 minutes of
illumination for egress.
VExQ units are designed for general and
task lighting in indoors or outdoors where
flammable gases or vapors, combustible
dusts, or simultaneous presence may exist
and create a hazardous location, as defined
by the NEC.
Use Push-To-Test station suitable for area of
use for testing purposes.
Note: VE3x dimensions are the same as VM3
VE4x dimensions are the same as VM4
See L128-L129 for more information
Photometrics similar to VQ1F Series.
• Stainless-to-Stainless securement
• Takes load off during installation
• Uses ordinar y tools
• Saves time and labor
NO External Seals. Lower T-codes, Suitable for Clas s I Div. 2 Classified
areas per the NEC®. See L8 4 for more information.
Compact (5-1/2” thread size, t ypes I & V)
Standard (7-3/4”, thread size,types I, III, V)
Enhances user selection flexibility
Easier Maintenance, saves labor, move fix ture from the ladder to the
workbench
Available as F ield or Factory Installedto s ave energy when light not
required. For AC ballast onl y.
Secures fix ture to structure in case of conduit failure. “3rd
Safety:
hand” accessories for lamp change out. See L83 for more
information.
Page 2
KILLARK LIGHTING
T
T
I
I
H
H
N
N
G
G
G
G
I
I
L
L
H
H
A
A
VE3Q / VE4Q SERIES
C
C
O
O
Z
Z
L
L
CATALOG ORDERING LOGIC
CertiLite® E Catalog Number Logic; 13- 84W Battery Backed (Compact Fluorscent) Fixtures
VE4Q 84 84 E30 A 3 R1 G (NR p)
VE3Q 5-1/2”
VE4Q 7-3/4”
Emerg. Quad-Pin C1D2, C2D1
AC Lamps Powered
00 - Emergency Only s
18 - 1 x 18 Quad-Pin
26 - 1 x 26 Quad-Pin
32 - 1 x 32 Quad-Pin
42 - 1 x 42 Quad-Pin
36 - 2 x 18 Quad-Pin
52 - 2 x 26 Quad-Pin
64 - 2 x 32 Quad-Pin
84 - 2 x 42 Quad-Pin
DC Lamps Powered
(also = # of batteries)s
18 - 1 x 18 Quad-Pin
26 - 1 x 26 Quad-Pin
32 - 1 x 32 Quad-Pin
42 - 1 x 42 Quad-Pin
36 - 2 x 18 Quad-Pin
52 - 2 x 26 Quad-Pin
64 - 2 x 32 Quad-Pin
84 - 2 x 42 Quad-Pin
Voltage
E30—120-277VAC Quad-Pin Normal &
Emergency or Emergency Only
Optic
GL— Globe (VE3, VE4)
R1— Type I Glass Refractor
R3— Type III Glass Refractor (VE4)
R5— Type V Glass Refractor
ER— Enclosed Reflector (VE4)
EP— Poylcarbonate Shielded
Enclosed Reflector (VE4) q
S2— Type II 12” Spin-Top Refractor
S8— Type V 8” Spin-Top Refractor
(VE3)
S5— Type V 12” Spin-Top Refractor
P5— Type V 12” Plastic Spin-Top
Refractor (VE3)
FG— Silicone l Coated Globe
TG— Teflon ®m Coated Globe
T1— Teflon ®m Coated Globe Type I
Glass Refractor
T3— Teflon ®m Coated Globe Type IIIGlass Refractor (VE4)
T5— Teflon ®m Coated Globe Type VGlass Refractor
T2— Teflon ®m Coated Type II 12”Spin-Top Refractor
T8— Teflon ®m Coated Type V 8”Spin-Top Refractor (VE3)
TV— Teflon ®m Coated Type V 12”Spin-Top Refractor
Options
RD— Red Tank/Mount/Guard
NR— Ex nA nR Restricted
Breathing p
F— Single fuse n
FF— Double fuse n
TBx— Terminal Blocks
P1— Photo Cell Factory 120V o
P2— Photo Cell Factory 208-277V o
QD— Quick Disconnect r
CP— Component Pack
AS— Assembled fixture
AN— Assembled no lamps
Guard
G—Guard
N—Without Guard
Mounting Type
A—Pendant
X—Ceiling
B—Wall Bracket
C—Cone Top
E—EZ Mount Adapter j
D—Stanchion 25°
S—Stanchion Straight 90°
N—None (mount ordered
separately) k
j Completes as “EZ”, conduit mounting boxes ordered
separately.
k NN mount ordered separately.
l Silicone coated globe for additional impact protection.
m Teon ® is a registered trademark of DuPont, Inc.
n Fusing not for Marine or Canadian installations
o Photo cells for Class I, Div. 2 only. VExx Models
p Restricted Breathing - See L8 4 for more information.
j See hazardous location data page L204 for application suitability
k VE3x models use 5-1/2” CertiLite®V VM optics accessories; VE4x models use 7-3/4” VM optics accessories.
** Grid is populated with 3/4” Pendant models with Optic Guards, to omit guard change last G to N e.g. VE3Q001*E10A2GLN
- 3/4” Ceiling models change A 2 to X2 - 3/4” Wall Bracket models change A2 to B2
- 3/4” Cone-top models change A2 to C2 - For 1” change to A3, X3, B3, or C3
j See hazardous location data page L204 for application suitability
k VE3x models use 5-1/2” CertiLite ® V VM optics accessories; VE4x models use 7-3/4” VM optics accessories.
** Grid is populated with 1-1/2” 25° Stanchion models with Optic Guards, to omit guard change last G to N e.g. VE3Q0018E10A2GLN
- 1-1/2” Straight models change D5 to S5 - 1-1/4” Stanchions change “5” to “4” e.g. D4 or S4
- EZ adapter models require EZ Mounts to energize
Page 5
COMPONENTS
KILLARK LIGHTING
VE3Q / VE4Q SERIES
T
T
I
I
H
H
N
N
G
G
G
G
I
I
L
L
H
H
C
C
A
A
O
O
Z
Z
L
L
5-1/2” Optic Thread Size
Tan k 3
Tan k 4
7-3/4” Optic Thread Size
BALLAST-BATTERY TANKS WITH LAMPS
DESCRIPTION INITIAL LUMENS
WATTS/ TYPEVOLTAGE
18W (1 x 18) Emer Only120 to 277 50- 60HzVE3Q0018E30VE4Q0018E30—400
36W (2 x 18) Emer Onl y120 to 277 50 -60HzVE3Q0036E30VE4Q0036E30—800
18W (1x18) Normal/Emer12 0 to 277 50- 60HzVE 3Q1818E30VE4 Q1818E301200400
36W (2 x18) Normal
18W (1x18) Emergency
36W (2x18) Normal/Emer120 to 277 50 -60HzVE3Q3636E30VE4Q3636E30240 0800
26W 1 x 26 Emer Only120 to 277 50- 60HzVE3Q0026E30VE4Q0026E30—425
52W 2 x 26 Emer Only120 to 277 50- 60HzVE3Q0052E30VE4Q0052E30—850
26W (1x 26) Normal /Emer120 to 277 50- 60HzVE3Q2626E30VE4Q2626E3018 00425
52W (2 x26) Norm al
26W (1x26) Emergency
52W (2x26) Normal/Emer120 to 277 50 -60HzVE3Q5252E30VE4Q5252E303600850
32W (1 x 32) Emer O nly120 to 277 50 -60HzVE3Q0032E30VE4Q0032E30—525
64W (2 x 3 2) Emer Only120 to 277 50 -60HzVE3Q0064E30VE4Q0064E30—10 50
32W (1x32) Nor mal/Emer120 to 277 5 0-60H zVE3Q3232E30VE4Q3232E302400525
64W (2 x32) Normal
32W (1x32) Emergency
64W (2 x32) Normal/Emer120 to 277 5 0-60H zVE3Q6464E30VE4Q6464E3048001050
42W (1 x 42) E mer Only120 to 277 50 -60HzVE3Q0042E30VE4Q0042E30—700
CLASS I DIV 2, CLASS II DIV 1, N4X, IP66 j
84W (2 x 42) Emer O nly120 to 277 50 -60HzVE3Q0084E30VE4Q0084E30—14 00
42W (1x42) Normal/Emer120 to 277 50 -60HzVE3Q4242E30VE4Q4242E303200700
“84W (2x42) N ormal
42W (1x42) Emergency”
84W (2x42) Normal/Emer120 to 277 50- 60HzVE3Q8484E30VE4Q8484E3064001400
120 to 277 50- 60HzVE3Q3618E30VE4Q3618E302400400
120 to 277 50- 60HzVE3Q5226E30VE4Q5226E303600425
120 to 277 50- 60HzVE3Q6432E30VE4Q6432E304800525
120 to 277 50- 60HzVE3Q8442E30VE4Q8442E306400700
5-1/2” OPTIC THREAD SIZE k7-3/4” OPTIC THREAD SIZE l
NORMAL ACEMER. BATTERY
j See hazardous location data page L204 for application suitability
Page 6
KILLARK LIGHTING
T
T
I
I
H
H
N
N
G
G
G
G
I
I
L
L
H
H
A
A
VE3Q / VE4Q SERIES
C
C
O
O
Z
Z
L
L
COMPONENTS
Pendant
25° Stanchion
Ceiling
Straight Stanchion
Wall
EZ Adapter*
VMEZA
MOUNTING SPLICE BOXES
CATALOG NUMBER
HUB SIZEPENDANTFLEXIBLE PENDANTCEILING 4 HUBCEILING 5 HUBWALLCONE TOP
*VMEZ A is used between a ballast tank and an EZ mount- ordered separately. See L 83 for more information.
**VMX8B furnished with 3 non-metallic plugs.
OPTICS & GUARDS
DESCRIPTION5-1/2” Optic T hread Size7-3/4” OpticThread Size
Globe (gl ass)
Refractor (all glass) Type V
Refractor (all glass) Type I
Refractor (all glass) Type III
Refractor (spin top glass) 8” Typ e V
Refractor (spin top glass) 12” Type V
Refractor (spin top glass) 12” Type II
Refractor (spin top plastic) 12” Type V
Enclosed Reflector (glas s lens)
Enclosed Reflector (plastic lens)
VEXA400 4-Sided EXIT for all Models
Letters are 3/4” x 8” Red on white
Unit includes 3 EXIT Faces and
2 Blank for Maximum Flexibility
Dimensions: 14.56” x 9. 22”
COMPONENTS/APPLICATION DATA
VEXA100B 3-Sided EXIT Accessory for
xE3x models
Letters are 3/4” x 6” Red on White
KILLARK LIGHTING
VE3Q / VE4Q SERIES
14.2"
8.1"
14.2"
T
T
I
I
H
H
N
N
G
G
G
G
I
I
L
L
H
H
C
C
A
A
O
O
Z
Z
L
L
9.25"6"
EXIT
FEATURES-SPECIFICATIONS
REPLACEMENT BATTERY UNITS
WATTAGE/ TYPECATALOG NUMBER
18/26/32/42W QUAD-PINKFBP7
REPLACEMENT LAMPS
WATTAGE/ TYPECATALOG NUMBER
26W QUAD-PINMQL18
26W QUAD-PINMQL26
32W QUAD-PINMQL32
42W QUAD-PINMQL42
BA LLAST DATA*
LAMP WATT SVOLTAGE ACSTARTOPER ATINGINPU T WATT SBALLAST CIRCUITREGULATION
26WATT (1X13)120 / 2770.39/.350.316NPF—
26WATT (2X13)120 / 2770.78/.700.632NPF—
18 WAT T (1X18)120 T HROUGH 277—.16@120V /.07 @277V19HPF—
26WATT (1X26)120 THROUGH 27 7—.27@120V /.13 @277V29HPFELECTRONIC
32WATT (1X32)120 THROUGH 277—.31@120V /.15 @277V36HPFELECTRONIC
42WATT (1X42)120 THROUGH 277—.37@120V /.17 @277V46HPFELECTRONIC
36 WATT (2X18)120 THROUGH 277—.32@120V /.14 @277V38HPF—
52WATT (2X26)120 THROUGH 277—.54@120V /.26 @277V58HPFELECTRONIC
64WATT (2X32)120 THROUGH 277—.62@120V /.30 @277V72HPFELECTRONIC
84WATT (2X42)120 THROUGH 277—.74@120V /.34 @277V92HPFELECTRONIC
* Add per battery prox .6 amp for charging current. Prox 24 hours to full recharge after full discharge.
VEXA100B Exit Accessory Dimensions
APPLICATION DATA
SUPPLY WIRE TEMP. MIN. °C
60
60
60
60
60
60
60
60
60
60
Page 8
KILLARK LIGHTING
T
T
I
I
H
H
N
N
G
G
G
G
I
I
L
L
H
H
A
A
VE3Q / VE4Q SERIES
C
C
O
O
Z
Z
L
L
COMPONENTS/APPLICATION DATA
APPLICATION DATA
CLASS I DIVISION 2CLASS I ZONE 2 nR II
CATALOG
SERIES*
LAMP
WATTS
AMBIENT
DEG. C
GLOBE OR
REFR ACTOR
j
GLOBE +
REFLECTOR
GLOBE OR
REFR ACTOR
k
GLOBE +
REFLECTOR
VE3Q00181 X 1840T6T6T6T6T3B (EFG)T3C (EFG)60
VE3Q00362 X 1840T3CT3CT6T6T3B (EFG)T3C (EFG)60
VE3Q18181 X 1840T3AT3AT6T6T3B (EFG)T3C (EFG)60
VE3Q36182 X 1840T3CT3CT6T6T3B (EFG)T3C (EFG)60
VE3Q36362 X 1840T3CT3CT6T6T3B (EFG)T3C (EFG)60
VE3Q00261 X 2640T6T6CT6T6T3B (EFG)T3C (EFG)75
VE3Q00522 X 2640T2DT2DT6T6T3B (EFG)T3C (EFG)75
VE3Q26261 X 2640T3AT3AT6T6T3B (EFG)T3C (EFG)60
VE3Q52262 X 2640T2DT2DT5T6T3B (EFG)T3C (EFG)75
VE3Q52522 X 2640T2DT2DT5T6T3B (EFG)T3C (EFG)75
VE3Q00321 X 3240T6T6T6T6T3B (EFG)T3C (EFG)75
VE3Q00642 X 3240T2DT2DT6T6T3B (EFG)T3C (EFG)75
VE3Q32321 X 3240T3AT3AT6T6T3B (EFG)T3C (EFG)60
VE3Q64322 X 3240T2DT2DT5T6T3B (EFG)T3C (EFG)75
VE3Q64642 X 3240T2DT2DT5T6T3B (EFG)T3C (EFG)75
VE3Q00421 X 4240T6T6T6T6T3B (EFG)T3C (EFG)75
VE3Q00842 X 4240T2BT2BT6T6T3B (EFG)T3C (EFG)75
VE3Q42421 X 4240T3AT3AT6T6T3B (EFG)T3C (EFG)60
VE3Q84422 X 4240T2BT2BT4T6T3B (EFG)T3C (EFG)75
VE3Q84842 X 4240T2BT2BT4T6T3B (EFG)T3C (EFG)75
VE4B00131 X 1340T3T3T6T6T3B (EFG) T3CT3C (EFG)60
VE4B00262 X 1340T3T3T6T6T3B (EFG) T3CT3C (EFG)60
VE4B13131 X 1340T3AT3AT6T6T3B (EFG) T3CT3C (EFG)60
VE4B26132 X 1340T3T3T6T6T3B (EFG) T3CT3C (EFG)60
VE4B26262 X 1340T3T3T6T6T3B (EFG) T3CT3C (EFG)60
VE4Q00181 X 1840T3CT3CT6T6T4A (EFG)T4A (EFG)60
VE4Q00362 X 1840T3CT3CT6T6T4A (EFG)T4A (EFG)60
VE4 Q18181 X 1840T3CT3CT6T6T4A (EFG)T4A (EFG)60
VE4Q36182 X 1840T3CT3CT6T6T4A (EFG)T4A (EFG)60
VE4Q36362 X 1840T3CT3CT6T6T4A (EFG)T4A (EFG)60
VE4Q00261 X 2640T3CT3CT6T6T4A (EFG)T4A (EFG)60
VE4Q00522 X 2640T3CT3CT6T6T4A (EFG)T4A (EFG)60
VE4Q26261 X 2640T3CT3CT6T6T4A (EFG)T4A (EFG)60
VE4Q52262 X 2640T3T3T6T6T4A (EFG)T4A (EFG)75
VE4Q52522 X 2640T3T3T6T6T4A (EFG)T4A (EFG)75
VE4Q00321 X 3240T3T3T6T6T4A (EFG)T4A (EFG)75
VE4Q00642 X 3240T3T3T6T6T4A (EFG)T4A (EFG)75
VE4Q32321 X 3240T3T3T6T6T4A (EFG)T4A (EFG)75
VE4Q64322 X 3240T3T3T6T6T4A (EFG)T4A (EFG)75
VE4Q64642 X 3240T3T3T6T6T4A (EFG)T4A (EFG)75
VE4Q00421 X 4240T3T3T6T6T4A (EFG)T4A (EFG)75
VE4Q00842 X 4240T3T3T6T6T4A (EFG)T4A (EFG)75
VE4Q42421 X 4240T3T3T6T6T4A (EFG)T4A (EFG)75
VE4Q84422 X 4240T3T3T6T6T4A (EFG)T4A (EFG)75
VE4Q84842 X 4240T3T3T6T6T4A (EFG)T4A (EFG)75
CLASS II DIVISION 1
GLOBE OR
REFR ACTOR
j
GLOBE +
REFLECTOR
l
SUPPLY WIRE
TEMP. MIN. °C
j T-codes for Refractors include VMR “All Glass” and VZ Spin-Top Types.
k Models suitable for Class II Div. 1 are also suitable for Class III.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.