NVSL Series LED
NVSZ Series Xenon
Non-Metallic
SIGNAL LUMINAIRES
Applications
These new signal luminaires can be excellent
warning devices in corrosive, wet NEMA 4X harsh
environments, and in hazardous locations.
Typical applications include manufacturing plants,
chemical and petrochemical processing facilities,
sewage treatment plants, off-shore and dockside
installations, agricultural, commercial, industrial,
mining and marine facilities.
Features:
- NVS Series LED with very compact prole
and 50,000 hours expected life; steady - on
or ashing.
- NVSZ Series Xenon with 10,000 hours
expected life (ashing only).
- LED utilizes inverted cone design to provide
full 360 degree coverage for more light
projection.
- LED and Xenon available in ve colors –
red, green, amber, blue and clear.
- Flash rate for LED is 7 micro ashes approx.
every second.
- Flash rate for Xenon is 60 to 80 ashes
per minute.
- Can be mounted in any orientation including
lens in the
UP or SIDE positions.
- Materials: High strength 30% glass-lled
thermoset polyester body with Lexan
- Resists corrosive effects of most chemicals,
hydrocarbons and solvents.
- Designed for indoor and outdoor applications.
NVS signals contain no exposed
glass and carry Class II, F & G
ratings required for many food
processing areas
®*
lens.
Class l, Div. 2, Groups A,B,C,D
Class l, Zone 2, Groups llC, llB, llA
Class ll, Div. 1&2, Groups F,G; Class lll
CSA Enclosure Type 4X, IP66
NEMA 4X, Marine Rated
NVSL LED NVSZ Xenon
C US to the following standards:
• UL 1598 Standard for luminaires
• UL 1598A Marine type luminaires
• UL 844 Standard for lighting xtures for hazardous locations
• UL 1638 Standard for visual signalling applications
• CSA C22.2 no. 137-M1981 electric luminaires for use in hazardous locations
• Enclosed and gasketed, NEMA 3, 4X IP66
Down & side orientation
Up & side orientation
Catalog Number Logic NVS L C F G 01 A A G Example: NVSLCFG25AAG
1 2 3 4 5 6 7 8 9 LED Gray Body Flashing Amber Pendant w/Guard 120-240VAC
1 NVS - Series Constant
Non-Metalic Signal
2 Source
L = LED
Z = Xenon
3 Fixture Size
C = Compact LED
M = Medium Xenon
4 Flash State
F = Flashing (LED or Xenon)
S = Steady LED
3/4” Pendant Amber Red Green Blue Clear
Flashing 120-240VAC NVSLCFG25AAG NVSLCFG25RAG NVSLCFG25GAG NVSLCFG25BAG NVSLCFG25CAG
LED
Flashing 12-80 VDC NVSLCFG26AAG NVSLCFG26RAG NVSLCFG26GAG NVSLCFG26BAG NVSLCFG26CAG
Flashing 120VAC NVSZMFG01AAG NVSZMFG01RAG NVSZMFG01GAG NVSZMFG01BAG NVSZMFG01CAG
XENON
Flashing 12-80 VDC NVSZMFG26AAG NVSZMFG26RAG NVSZMFG26GAG NVSZMFG26BAG NVSZMFG26CAG
3/4” Ceiling Amber Red Green Blue Clear
Flashing 120-240VAC NVSLCFG25AXG NVSLCFG25RXG NVSLCFG25GXG NVSLCFG25BXG NVSLCFG25CXG
LED
Flashing 12-80 VDC NVSLCFG26AXG NVSLCFG26RXG NVSLCFG26GXG NVSLCFG26BXG NVSLCFG26CXG
Flashing 120VAC NVSZMFG01AXG NVSZMFG01RXG NVSZMFG01GXG NVSZMFG01BXG NVSZMFG01CXG
XENON
Flashing 12-80 VDC NVSZMFG26AXG NVSZMFG26RXG NVSZMFG26GXG NVSZMFG26BXG NVSZMFG26CXG
3/4” Wall Amber Red Green Blue Clear
Flashing 120-240VAC NVSLCFG25ABG NVSLCFG25RBG NVSLCFG25GBG NVSLCFG25BBG NVSLCFG25CBG
LED
Flashing 12-80 VDC NVSLCFG26ABG NVSLCFG26RBG NVSLCFG26GBG NVSLCFG26BBG NVSLCFG26CBG
Flashing 120VAC NVSZMFG01ABG NVSZMFG01RBG NVSZMFG01GBG NVSZMFG01BBG NVSZMFG01CBG
XENON
Flashing 12-80 VDC NVSZMFG26ABG NVSZMFG26RBG NVSZMFG26GBG NVSZMFG26BBG NVSZMFG26CBG
See KILLARK Catalog for additional voltages and steady LED luminaires *Lexan® is a registered trademark of General Electric
5 Color (Body, Mount, Guard)
G = Gray
6 Voltage
01 - 120VAC 50/60Hz Xenon model
08 - 240VAC 50/60Hz Xenon model
25 = 120 - 240VAC 50/60Hz LED model
26 = 12-80VDC (24VAC) LED or Xenon
7 Color of Signal
A = Amber, R = Red, G = Green,
B = Blue, C = Clear
8 Mount Type
A = 3/4” pendant
X = 3/4” Ceiling
B = 3/4” Wall Bracket
(consists of ceiling box and
elbow to support body)
M = M20 Ceiling
W = M20 Wall Mount
9 Guard
G = Guard
N = No Guard
Hazardous Location Suitability
CLI CL2
Div.2 Div.1
Source
Operating
Temp. Code
LED T6 F,G
Xenon T2C F,G
Groups