Class I, Div. 2, Groups A,B,C,D*
Class l, Zone 2, Groups llC,llB,llA
Class II, Div. 1 & 2, Groups E,F,G*
Class III
Suitable for wet locations
Marine Rated (US Only)
NEMA 3, 4X
- Files E10514 and E91793 (Marine)
Certified - File LR11713
T
T
I
I
H
H
N
N
G
G
G
G
I
I
L
L
H
H
C
C
A
A
O
O
Z
Z
L
L
Applications
CertiLite® MB fixtures are designed for
installations where moisture, dirt, dust,
corrosion and vibration may be present, or
NEMA 3 and 4X areas where wind, water,
snow or high ambients can be expected.
They can be used in locations made
hazardous by the presence of flammable
vapors or gases or combustible dusts as
defined by the NEC.
Typical applications include manufacturing
plants, and certain chemical and
petrochemical processing facilities, sewage
treatment plants, off-shore and dockside
installations, garages and storage facilities.
Features
• Ballast tank and splice box –
corrosion resistant copper-free
aluminum alloy
• Baked powder epoxy/polyester finish,
electrostatically applied for complete,
uniform corrosion protection
• All external hardware – stainless steel
• Guard – copper-free aluminum alloy
• Normally shipped as components for
quick delivery
• Refractor guard – steel with corrosion
resistant finish
• Reflector – lightweight, corrosion
resistant fiberglass reinforced
polyester
• Fluorescent models furnished with lamps.
Energy efficient instant on white light
(2700K). 10,000 hour lamp life
• HID lamp holders are E26 medium base
Compliances
• UL-1572 Standard for HID lighting
fixtures
• UL-1570 Standard for Fluorescent
fixtures
• UL Marine type lighting fixtures (HID
models) UL-844 Standard for lighting
fixtures for hazardous locations, Class
I, Division 2; Class II, Divisions 1 and 2;
Class III
• CSA C22.2 no. 137-M1981 electric
luminaries for use in hazardous
locations
• Enclosed and gasketed
• NEMA 3, 4X
Catalog Number Logic
MB 0 00 0 - 000 00
Series Constant
Lamp Type
F—Fluorescent
L—High Pressure Sodium
H—Metal Halide
j Catalog numbers shown are 120. Consult factory for other available voltages.
k Catalog numbers shown with 3/4” conduit openings (1-1/4” on stanchion mount) and includes globe and guard or
IES type V 8” glass refractor and guard. See catalog logic for other possible congurations.
* See Hazardous Location Application Data on page L72 for limitations.
jMetal Halide MB xtures use quad-volt ballasts.
k Catalog numbers shown with 3/4” conduit openings (1-1/4” on stanchion mount) and include globe and guard or
IES type V 8” glass refractor and guard. See catalog logic for other possible congurations.
l 50, 70, 100 MH Ballasts include a separate ignitor and are PULSE circuits.
* See Hazardous Location Application Data on page L72 for limitations.
MPL13Replacement lamp for MBF and EBF series
ENY-2SE T3/4 ENY seal with set screw for sealed (E x nR) pendant installations
ENY-3 SET1 ENY seal with set screw for sealed (E x nR) pendant installations
MB BALLAST DATA
LAMP TYPE
LAMP WATTS
FLj
HPS
MH
jPer lamp, max available amps @ 120VAC is 0.3A; max @ 277VAC is 0.2A
kBallasts are High Power Factor 90%+.
lLamp watts within ANSI Trapezoid limitations.
j Verify temperatures for suitability for intended use.
k Includes both standard dome and angle reectors.
l Guard required for Class II, D ivision 1 and Class III, Division 1 applications.
m Note: 8 inch glass refractor not CSA certied for Class II, Division 1 and Class III, D ivisions 1 installations.
LAMPS/
WATTS
1340( T3B) 165°C(T4) 13 5° CE, F & GYES90
26 (2x 13)40(T 3B) 165° C(T4) 135°CE, F & GYES90
39 (3x13)25(T 3A) 180° C(T4) 13 5°CE, F & GYES90
j Verify temperatures for suitability for intended use.
k Includes both standard dome and angle reectors.
l Guard required for Class II, D ivision 1 and Class III applications.
m Based on luminaire with globe and guard only.
n 150 watt HPS—Groups E, F only with or without re ector and Groups E, F and G with refractor.