Killark-Hubbell Electrical Products LAL SERIES, LALxE SERIES, LALC SERIES Catalog Page

Page 1
KILLARK LIGHTING
T
T
I
I
H
H
N
N
G
G
G
G
I
I
L
L
H
H
A
A
Z
Z
LAL/LALxE/LALC SERIES
C
C
O
O
L
L
LOW PROFILE LINEAR ALUMINUM LED • EXCLUSIVE DESIGN FEATURES
High temperature rated silicone gasketing provides NEMA 4X & IP66 sealing.
Looping Terminal Blocks under Wiring Access
Plate(s).
Diffused Clear
2 Lens Choices:
Clear for maximum lumens
Diffused for glare control
Optional Through Wiring
2 Access Plates for feed through wiring
End Caps include feet for direct ceiling mounting and safety
cable connection
Battery
E13 and E26 models include internal Emergency battery systems to 50°C suitability
Surge
Standard with internal 20kA/10kA Supplemental Surge Protection
Endcaps standard with 1 x 3/4” hub. 1/2” NPT and M20 available.
Shown with LAL- SB Height adjustable Swivel Brackets
Mounting Slots on back and at 45°
Earth
External Earth Ground for IECEx requirement
Page 2
Double Lens Model
FEATURES-SPECIFICATIONS
Applications
Linear LED Luminaires are designed for installations where moisture, dirt, dust, corrosion and vibration may be present, and NEMA 3, 4X, IP66 areas where wind, water, snow or high ambients can be expected. They can be used in locations made hazardous by the presence of flammable vapors or gases or combustible dusts as defined by the NEC/CEC/IEC.
Typical applications include land based oil rigs, offshore oil platforms, dockside installations, chemical and petrochemical processing facilities, sewage treatment plants, garages, storage facilities, tunnels, and grain/food facilities.
ABS (American Bureau of Shipping) type approval for use on decks, vessels, platforms, barges, ships and boats. Also suitable for docks and marinas.
Compliances
UL-8750 for LED lighting
ANSI/UL 1598(A)
UL-844 Standard for lighting fixtures for
hazardous locations, Class I, Division 2; Class II, Divisions 1 and 2; Class III
CSA C22.2 no. 137-M1981 electric
luminaires for use in hazardous locations
IEC suffix Zone 2/21 to IEC 60079-0,
60079-15, 60079-31 Standards
Enclosed and gasketed
NEMA 3, 4X
IP66
Materials
NEMA 4X & IP66 rated
Housing – one piece natural finish < .001
copper-free aluminum extrusion
LINEAR LED TECHNOLOGY
LALC Compact
Single Lens Model
Endcaps & wiring – Access covers are
copper-free (< .004) aluminum with gray baked powder epoxy-polyester finish, electrostatically applied for complete uniform corrosion resistance.
External screws are 316 stainless steel
Lens – Impact resistant polycarbonate
lens available in diffuse or clear
LAL & LALxE Product Features
LALxE models have “built-in” battery
backup for 90 minute emergency exit
Shallow design minimizes profile in work
areas with low ceiling heights
Diffuse Lens Standard to minimize glare;
Clear Lens available
Polycarbonate Single Lens 18W to 60W;
Double Lens model 34W – 120W
Slot Back Design allows multiple
mounting access points across length – slots can also be used with 5/16” or 8mm bolts & nuts, 3 housing slots, 1 center back and 2 at 45°.
Variety of mounting options including
swivel brackets, wall, ceiling brackets, or beam clamps
End Caps each have 2 mounting feet built-in
plus a safety strap attachment point
Standard unit End Caps each have single
a ¾” NPT hub, and fixture is furnished with one ¾” close-up plug and two ¾” to ½” reducers – provides out of the box ½” dead-end to ¾” feed-through flexibility. Metric openings are available.
Standard LALs have one wiring Access
Plate for easy access to driver leads.
Supplemental 20KA/10KV Surge
Protection is standard (for AC models)
KILLARK LIGHTING
L
L
LAL/LALxE/LALC SERIES
Class I, Div. 2, Groups A, B, C, D Class l, Zone 2, Groups IIC, llB, llA Class II, Div. 1 & 2, Groups E, F, G AEx nAII, Ex nAII Wet Locations NEMA 4X IP66
Certified - File LR11713
IECEx Rated Zone 2 and Zone 21 areas Ex nA IIC T6 to T3, Gc Ex tb IIC T95°C Db Tamb -50°C < Tz < +65°C, IP6 6 IECEx Certificate QPS 15.0010
ATEX Certificate CML 15AT EX4081X (nA) & CML15ATEX3082X (tb)
H
H
NON-GLASS
GROUP G
FOOD SUITABILITY
LED Features and Standards
Many Midpower LEDs blend light to
simulate fluorescent tubes
Crisp White Light for Excellent Color
Rendering – Chromaticity 5000K (CCT); approx. 70 CRI
Energy Savings – High lumens per watt
LED Array Life – to 212,000 maintenance
free hours to 70% initial lumens
Ambient suitability -40°C to 65°C (see
tables). 50° Ambient limit for Emergency
models.
Instant On – Including after power
interruption
World Voltage 120 - 277VAC 50/60Hz
Solder-LESS LED Board Connections –
Vibration Resistant
LM80-08* Measurement of lumen
maintenance for LED light sources
LM79-08* Certified “Absolute”
Photometry, including Chromaticity Color for Solid State Lighting
L70 Values – Industry Nomenclature for
Hours of use to 70% of initial Lumens – TM-21* & Calculated
* LM-xx & TM-xx are Illumination Engineering Society Standards designed to promote uniformity in testing procedures among test labs and manufacturers. For more information go to www.ies.org
T
T
I
I
H
H
N
N
G
G
G
G
I
I
C
C
A
A
O
O
Z
Z
L
L
Page 3
KILLARK LIGHTING
T
T
I
I
H
H
N
N
G
G
G
G
I
I
L
L
H
H
A
A
Z
Z
LAL/LALxE/LALC SERIES
C
C
O
O
L
L
CATALOG LOGIC
LAL(C) – Series Constant
LAL(R) –
Aluminum Extrusion with Polycarbonate Lens
Rig Version with Poke out Hubs
Fixture Wattage 18 28 45
Single Lens – Dimension B or C (C required for E13 Emergency or for Non-emergency to match E13 length)
60 34 55 80
Two Lens – Dimension D for Non-emergency, or E13 or E26 Emergency)
120 C15 C20 C25 C30
Compact Lens – See Dimension
A
C35 C40 C45 C50
Emergency Battery Backup (LAL 120­277VAC 50/60Hz only, not LALC Compact)
Blank –
No Emergency
E13
LAL 120-277VAC all Models; 18W, 28W, 45W,
60W use extended 4’ housing
E26
LAL 120-277VAC 34W, 55W, 80W, 120W
2-Lens models
LAL 45 E13 30 D L4-2AP FF
Lens D –
Diffuse Polycarbonate
C –
Clear Polycarbonate
Example = 45W 4PCB with 13W Emergency 120 - 277VAC
with Diffuse Lens, 2 Fuses, 2 Access Plates Dimension “B”
Options L4-2AP – LAL 18W, 28W, 45W, 60W with E13 Emer or
Non-Emer to match E13 length (Dimension B)
F –
Single Fuse (1 pole)
FF –
Two Fuses (2 pole - 2 hot legs)
S52 –
1 Endcap with 1x1/2” NPT and 1xM20
Entries (3/4” NPT Plugged)
D52 –
2 Endcaps with 1x1/2” NPT and 1xM20
Entries (3/4” NPT Plugged)
D50 –
2x1/2” NPT Entries 1 end cap, 3/4”
plugged; 2nd end cap std. 1x3/4” NPT
D502 –
2x1/2” Entries 2 end caps, 3/4” NPTs
plugged
D20 –
2xM20 Entries 1 end cap, 3/4” plugged;
2nd end cap std. 1x3/4”NPT
D202 –
2xM20 Entries 2 end caps, 3/4” NPTs
plugged
LSP –
Less Surge Protector
GH –
Gray Painted Housing
RH –
Red Painted Housing
2AP –
Dual Access Platesl
Specials – Contact Factory for custom congurations and options
Voltage 30 –
120V-277VAC 50/60Hz LAL/LALC all models
27 –
12VDC - 24VDC LALC 15W, 20W, 25W models only
33 –
347-480VAC LAL 28W & 55W non-emergency models only
34 –
125VDC-250VDC; 120-277VAC 50/60Hz LALC 15W, 18W, 20W, 23W, 25W
and LAL 28W, 60W, 55W, 120W non-emergency models
Energy Savings
LED VS FLUORESCENT WATTAGE & DELIVERED LUMENSjk
LED WATT LUMENS L/W FLUORESCENT LUMENS L/W
18W 2557 150 40W 1x40W BX 2471 63 28W 3775 144 55W 1x55W BX 3766 65 34W 5075 14 9 56W 2x28T5 4676 71 45W 5562 137 64W 2x32T8 4772 80 55W 7577 144 108W 2x54T5HO 8088 67 60W 76 18 132 120 W 2x60T12HO 6965 56 80W 11140 137 162 3x54T5HO 11619 65
j Cataloged Wattage in L Z2x Fluorescent or LALx LED
luminaires – actual varies with driver or ballast losses – Delivered Lumens and L/W from photometry testing
k LAL L70 Life 99,6 00 -212,00 0 hours
LZ2x Fluorescent 10,000-60,000 hours
LED array calculated L70 life depending on
ambient temperature. L70 values indicate 70% of initial illumination after “x” hours (see next page). Fluorescent typically operates to 20,000 hours (some wattages as few as 10,000 hours; specialty 32W lamps to 60,00 0 hours)
l 2AP Length Dimensions will increase by 4.2”.
Page 4
ORDERING INFORMATION AND AMBIENT SUITABILITY
WEIGHT
CATALOG NUMBER W/
DIFFUSE LENS j
LA L1830D
LA L18E1330D-L4-2AP LAL2830D LAL2830D-L4-2AP LAL28E1330D-L4-2AP LAL4530D LAL4530D-L4-2AP LAL45E1330D-L4-2AP LAL6030D
LAL60E1330D-L4-2AP LAL3430D
LAL34E2630D LAL5530D LAL55E1330D LAL55E2630D LAL8030D
LAL80E2630D LAL12030D
LA L120E2630D LALC15 27D LALC1530D LALC1534D LALC2027D
LALC2034D LALC2527D
LALC2534D LALC3030D 30 LALC3530D 35 LALC4030D 40 LALC4530D 45 LALC5030D 50
j See Logic Notes for Options k Shipping weights l See dimensional detail. m Standard Power Lumens
WATTS LBS./ KG k
POWER
17.9 / 8.1
21.9 / 9.9 C-51 (1295)
31.9 / 14.5 C-51 (1295)
17.9 / 8.1
21.9 / 9.9 C-51 (1295)
31.9 / 14.5 C-51 (1295)
17.9 / 8.1
21.9 / 9.9 C-51 (1295)
31.9 / 14.5 C-51 (1295)
18.9 / 8.6
22.9 / 10.4 C-51 (1295)
32.9 / 14.9 C-51 (1295)
34.5 / 15.6
44.5 / 20.2
54.5 / 24.7
34.5 / 15.6
44.5 / 20.2
54.5 / 24.7
34.5 / 15.6
44.5 / 20.2
54.5 / 24.7
36.5 / 16.6
46.5 / 21.1
56.5 / 25.6
12.03 / 4.49
STD.
18
28
45
60
34
55
80
120
15
20
25
LENGTH
l
B-32.6 (828)
B-32.6 (828)
B-32.6 (828)
B-32.6 (828)
D-57.9 (1471) D-57.9 (1471) D-57.9 (1471) D-57.9 (1471) D-57.9 (1471) D-57.9 (1471) D-57.9 (1471) D-57.9 (1471) D-57.9 (1471) D-57.9 (1471) D-57.9 (1471) D-57.9 (1471)
A-18.73 (476)
A-18.73 (476)
A-18.73 (476)
A-18.73 (476) A-18.73 (476) A-18.73 (476) A-18.73 (476) A-18.73 (476)
ORDERING INFORMATION
C1D2 ABCD/
ZONE 2 IIC, IIB,
IIAn
VOLTAGE
120-27 7 VAC
120-27 7 VAC
12-24 VD C 120-27 7 VAC 120-250VDC
12-24 VD C 120-27 7 VAC 120-250VDC
12-24 VD C 120-27 7 VAC 120-250VDC
120-27 7 VAC
Lumen s
AMPS q
0.15 - 0.06 2272 / 2479
0.23 - 0.10 3321 / 3624
0.38 - 0.16 5054 / 5515
0.50 - 0.22 7064 / 7709
0.28 - 0.12 4517 / 4929
0.46 - 0.20 6864 / 7490
0.67 - 0.29 10110 / 11032
1.00 - 0.43 15090 / 16467
0.15-0.06
0.17-0.08
0.18-0.08
0.26-0.11 2726 / 2974
0.30-0.13 3261 / 3558
0.34-0.15 4152 / 4530
0.38-0.17 5136 / 5604
0.42-0.18 6039 / 6590
Diffuse/
1.3-0.6 1503 / 1640
0.2-0.1
1.7-0.8 2337 / 2550
0.2-0.1
2.1-1.0 3019 / 3294
0.2-0.1
40C 55Cp65Cp40C 55C p65C p40C 55C p65C p40°C
Clear
T6 T6 T5 T4A T4A T4A T4A T4A T4A T6 T6 T5 T4 T4 T4LAL1830D-L4-2AP
T6 T6 T5 T4A T4A T4A T4A T4A T4A T6 T6 T5 T4 T4 T4
T6 T5 - T4A T4 A T4A T4A T4A T4A T6 T5 T5 T4 T4 T4
T6 T5 - T4A T4 A - T4A T4A - T6 T5 - T4 T4 -LAL6030D-L4-2AP
T6 T5 - T4A T4 A - T4A T4A - T6 T5 - T4 T4 -LAL34E1330D
T6 T5 - T4A T4 A - T4A T4A - T6 T5 - T4 T4 -
T6 T5 - T4A T4 A - T4A T4A - T6 T5 - T4 T4 -LAL80E1330D
T6 T5 - T4A T4 A - T4A T4A - T6 T5 - T4 T4 -LA L120E1330D
T5 T4A - T4A T4A T4 A T4A - T5 T4 - T4 T4 -
T5 T5 - T4A T4 A T4A T4 A - T5 T5 - T4 T4 -LALC2030D
T5 T4A - T4A T4A T4 A T4A - T5 T4 - T4 T4 -LALC2530D
T5 T4A - T4A T4A T4 A T4A - T5 T4 - T4 T4 ­T5 T4A - T4A T4A T4 A T4A - T5 T4 - T4 T4 ­T5 T5 - T4A T4 A T4A T4 A - T5 T5 - T4 T4 ­T5 T5 - T4A T4 A T4A T4 A - T5 T5 - T4 T4 ­T5 - - T4 A - - T4A - - T5 - - T4 - -
n Use 75°C Minimum Supply Wire @ 40 °C; Use 90°C Wire at 55° or 65°C o 55°C or 65°C where listed
p T-Codes for 55°C or 65°C reect maximum internal or external temperatures.
However, E13 or E26 Emergency units are limited to 50°C ambient to protect electronics and batteries.
C1D2n
GRPS. EFG
SIMULTANEOUS
KILLARK LIGHTING
LAL/LALxE/LALC SERIES
C2D1n
GRPS. EFG
IEC ZONE 2 IEC ZONE 21
55°C p65°C p40°C
G
G
I
I
L
L
H
H
A
A
55°C p65°C
p
T
T
I
I
H
H
N
N
G
G
C
C
O
O
Z
Z
L
L
LAL
LED LUMEN LIFE L70 CALCULATED L70 TM-21**
40°C Ambient 212,000 Hours to 70% Initial 60,600 Hours Official Reported
55°C/65°C Ambiento
** TM-21 based values require very long duration testing. IES TM-21 “official reported” is based on at least 10,000 hours of LED chip manufacturer’s LM-80 Testing at printing.
99,600 Hour s to 70% Initial 60,40 0 Hours Official Reported
LED LUMEN LIFE L70 CALCULATED L70 TM-21**
Extra High L/ W Models
High L /W Models 270,000 Hours to 70% Initial 60,100 Hours Official Repor ted
50W High L/ W Models
278,000 Hours to 70% Initial 72,600 Hours Official Repor ted
190,000 Hours to 70% Initial 60,300 Hours O fficial Repor ted
LALC
Page 5
KILLARK LIGHTING
T
T
I
I
H
H
N
N
G
G
G
G
I
I
L
L
H
H
A
A
Z
Z
LAL/LALxE/LALC SERIES
C
C
O
O
L
L
DIMENSIONS AND ACCESSORIES
A: Dimensions for LALC
B: Dimension for Single Lens without Emergency Backup (17.9 lbs.)
3.92 [100]
C: Dimension Single Lens with Emergency Battery or Extended Model to Match Emergency Length
D: Dimension Double Lens with or without
T-SLOT FOR 5/16 DIA BOLT
5.76 [146]
2.88 [73]
TYP. (3) LOCATIONS
Emergency Battery
End Views
1.60 [41]
Page 6
KILLARK LIGHTING
4.50
1.80 [45.7]
.50 [12.7]
R.17 [4.3]
.34
[8.7]
.75 [19.1]
1.25 [31.8]
2.31 [58.7]
1.80
[63.5]
1.80 [45.7]
.50 [12.7]
R.17 [4.3]
.34
[8.7]
.75 [19.1]
1.25 [31.8]
2.31 [58.7]
2.50 [63.5]
LAL/LALxE/LALC SERIES
ACCESSORIES AND REPLACEMENT PARTS
ACCESSORIES AND REPLACEMENT PARTS: jk
LAL-SB
LZCB Ceiling Bracket Set with Stainless Steel Bolts to attach to L AL(C) “slots” LZWB Wall Bracket Set with St ainless Steel Bolts to attach to LAL(C) “slots” LAL-BC Steel/malleable Iron with Zinc electroplate for corrosion resistance; includes Stainless Steel Bolts to attach to LA L(C) “slots” LAL-EB Eyebolt Set with Stainless Steel Bolts to att ach to L AL(C) “slots” LAL-SSC 4’ Stainless Safety Cable Loop/ Loop Spring Safe ty Carabiner Hook LALG Stainless Guard for 1 L AL Lens, order two for 2 lens models LALCG LALC Stainless Guard LAL-LENSCLR Single Clear Lens with Gasket for LAL Series LAL-LENSDIF Single Diffuse Lens with Gasket for LAL Series LALC-LENSCLR Single Clear Lens with Gasket for LALC Series LALC-LENSDIF Single Diffuse Lens with Gasket for LALC Series LAL-RIG-CB Rig Mounting Style Ceiling Bracket LAL-RIG-WB Rig Mounting Style Wall Bracket
Swivel Bracket Set w/ Adjustable Height; includes 5/16” bol ts/nuts/lock-washer s for attachment to LAL(C) “slots; c an also be at tached to end cap mounting feet with FBO bolts.
T
T
I
I
H
H
N
N
G
G
G
G
I
I
L
L
H
H
C
C
A
A
O
O
Z
Z
L
L
[114.3]
1.25
l
4.00 [101.6]
[31.8]
2.31 [58.7]
LAL-SB on Center Slot L AL-SB on 45° Slot LAL-SB Dimensions – extended shown
[45.7]
R.17 .75 [19.1]
.34
[8.7]
2.50
[4.3]
.50
[12.7]
l Un-extended height 3.25” (82.6)
.38 [9.5]
1.00 [25.4]
1.13 [28.6]
1.80 [45.7]
Ceiling Bracket Setk
Part Number LZCB
Stainless Steel (natural nish)
Wall Bracket Setk
Part Number LZWB
Stainless Steel (natural nish)
LAL-SSC
[23.8]
Attached to 1 of 3 End Cap
Attachment Positions
-18
LAL-SSC Safety Cable
j Dimensions in ( ) are millimeters. k Product accessories have hardware for at tachment to
xture; hardware to attach to wall/ceiling F.B.O.
[3 8 .1]
LAL-BC Beam Clamp
Loading...