Killark-Hubbell Electrical Products HKH SERIES Catalog Page

Page 1
T
T
N
N
O
O
C
C
H
H
Z
Z
KILLARK CONTROLS
R
R
O
O
L
L
S
S
HKH SERIES
C
C
O
O
L
L
Legend Plate
Optional
Customer I.D.
Nameplate
Optional
NON-METALLIC DIN RAIL MOUNT
Component
Mounting Rail
Explosion Protective
LED Pilot Light
Explosion Protected
Contact Block
Actuator
Stainless Steel
Cover Screws
Applications
Hazardous and corrosive environments
due to the presence of flammable gases or vapors, combustible dusts or ignitable fiber or flyings.
Installations at petroleum refineries,
chemical and petrochemical plants and other processing or storage facilities where similar hazards exist.
Use in conjunction with motor starters or
contactors for remote control of motors.
Complies with RoHS, WEEE, ATEX, EMC and Low Voltage directives.
Silicone Sealing
Washer
Materials
Impact Resistant Non-Metallic PA6
Glass Reinforced Antistatic Material with f1 UV Protection against the most severe exposure to sunlight with a Flame Retardant rating of V-0.
Silicone gasketing on all enclosures and
operators throughout.
Brass gland plates available for metric size
applications of plastic enclosures.
Locknut
Brass Ground Plate w/ Green Terminals
Conduit Hub or
Cable Connector
Mounting
Features
Size 1 Control Stations available as 1a,
1b, & 1c as standard catalog number offerings for 1, 2 & 3 device openings and will accept 2-M20 entries in either end. Ammeters available in 1b & 1c. Size 2 Enclosures available as 2a & 2c for 2, 4 & 6 device entries in cover with ability to accept 2-M25 entries in either end.
Operating Temperature of -50ºC to +60ºC
Explosion Protected contact blocks
690VAC N.O. & N.C. capable of 20 Amps for Switching Duty and HP Ratings up to 1HP.
LED Pilot Light modules for 12-250V AC/
DC for UL applications. 12-254V AC/DC for IEC applications.
Contacts & Pilot lights can be mounted
inside enclosure on Din Rail or in cover to the actuator.
Accessories available for Lockout/Tag Out
functions made in 316 stainless steel.
Slot
Page 2
Optional
Customer I.D.
Nameplate
Optional
Legend Plate
NON-METALLIC PANEL MOUNT
Explosion
Protective LED
Pilot Light
KILLARK CONTROLS
HKH SERIES
Panel Mount
Bracket
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
C
C
O
O
Z
Z
L
L
Actuator
Stainless Steel
Cover Screws
Applications
Hazardous and corrosive environments
due to the presence of flammable gases or vapors, combustible dusts or ignitable fiber or flyings.
Installations at petroleum refineries,
chemical and petrochemical plants and other processing or storage facilities where similar hazards exist.
Use in conjunction with motor starters or
contactors for remote control of motors.
Complies with RoHS, WEEE, ATEX, EMC and Low Voltage directives.
Locknut
Silicone Sealing
Washer
Materials
Impact Resistant Non-Metallic PA6
Glass Reinforced Antistatic Material with f1 UV Protection against the most severe exposure to sunlight with a Flame Retardant rating of V-0.
Silicone gasketing on all enclosures and
operators throughout.
Brass gland plates available for metric size
applications of plastic enclosures.
Explosion Protected
Contact Block
Brass Ground Plate w/ Green Terminals
Mounting
Slot
Conduit Hub or
Cable Connector
Features
Size 1 Control Stations available as 1a,
1b, & 1c as standard catalog number offerings for 1, 2 & 3 device openings and will accept 2-M20 entries in either end. Ammeters available in 1b & 1c. Size 2 Enclosures available as 2a & 2c for 2, 4 & 6 device entries in cover with ability to accept 2-M25 entries in either end.
Operating Temperature of -50ºC to +60ºC
Explosion Protected contact blocks 690VAC
N.O. & N.C. capable of 20 Amps for Switching Duty and HP Ratings up to 1HP.
LED Pilot Light modules for 12-250V AC/
DC for UL applications. 12-254V AC/DC for IEC applications.
Contacts & Pilot lights can be mounted
inside enclosure on Din Rail or in cover to the actuator.
Accessories available for Lockout/Tag Out
functions made in 316 stainless steel.
Page 3
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
STANDARD SIZE 1a NON-METALLIC CONFIGURATIONS
Momentary
Push Button
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations of pilot lights and push buttons.
One entry listed is located at bottom.
Momentary & Maintained
Mushroom P.B.
Pilot Light
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
HKH MOMENTARY SINGLE PUSH BUTTON
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2P11K8 HKH1ANP2P11K8 3/4” NPT SS HUB
HKH1ANDAP11 HKH1ANPAP11 M20 CLEARANCE HOLE
SUPPLIED WITH 7 COLORED AND M ARKED DISCS – SEE BUTTON COLOR
ENTRY SIZE
CONTACT ARRANGEMENT
13
14
HKH MOMENTARY SINGLE PUSH BUTTON - MUSHROOM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2M11BK8 HKH1AND2M21AK8 HKH1AND2M310K8
HKH1ANDAM11B HKH1ANDAM21A HKH1ANDAM310
HKH1ANP2M11BK8 HKH1ANP2M21AK8 HKH1ANP2M310K8
HKH1ANPAM11B HKH1ANPAM21A HKH1ANPAM310
ENTRY SIZE
3/4” NPT SS HUB
M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
13
14
HKH MAINTAINED SINGLE PUSH PULL BUTTON - MUSHROOM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2M41BK8 HKH1AND2M51AK8 HKH1AND2M610K8
HKH1ANDAM41B HKH1ANDAM51A HKH1ANDAM610
HKH1ANP2M41BK8 HKH1ANP2M51AK8 HKH1ANP2M610K8
HKH1ANPAM41B HKH1ANPAM51A HKH1ANPAM610
ENTRY SIZE
3/4” NPT SS HUB
M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
13
14
CONTACT
BLOCKS
1 N.O. / 1 N.C.
CONTACT
BLOCKS
1 N.O. / 1 N.C.
CONTACT
BLOCKS
1 N.O. / 1 N.C.
BUTTON
COLOR
GREEN:
START/(I)/ BL ANK
RED:
STOP/(O)/BLANK
BLACK: BLANK
BUTTON
COLOR
RED GREEN BLACK
RED GREEN BLACK
BUTTON
COLOR
RED GREEN BLACK
RED GREEN BLACK
LEGEND PLATE
MARKING
NONE
LEGEND PLATE
MARKING
STOP START BLANK
STOP START BLANK
LEGEND PLATE
MARKING
STOP START BLANK
STOP START BLANK
HKH SINGLE PILOT LIGHT
3/4” NPT SS HUB SUPPLIED M20 CLEARANCE HOLE SUPPLIED CONTACT ARRANGEMENT
DIN RAIL MOUNT PANEL MOUNT DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2LRL0K8 HKH1AND2LGL0K8 HKH1AND2LAL0K8 HKH1AND2LCL0K8 HKH1AND2LBL0K8
HKH1ANP2LRL0K8 HKH1ANP2LGL0K8 HKH1ANP2LAL0K8 HKH1ANP2LCL0K8 HKH1ANP2LBL0K8
HKH1ANDALRL0 HKH1ANDALGL0 HKH1ANDALAL0 HKH1ANDALCL0 HKH1ANDALBL0
HKH1ANPALRL0 HKH1ANPALGL0 HKH1ANPALAL0 HKH1ANPALCL0 HKH1ANPALBL0
LA MP VOLTAGE COLOR
12V-254V AC/DC
IEC EX
12V-250V AC/DC
UL
RED LED GREEN LED AMBER LED CLEAR LED
BLUE LED
LEGEND PLATE
MARKING
BLANK
Page 4
STANDARD SIZE 1a NON-METALLIC CONFIGURATIONS
ATEX/IECEx Certified
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X
Maintained
Mushroom P.B.
Pull Release
Maintained
Mushroom P.B.
Twist Release
Double
Momentary
Push Button
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations of mushroom push buttons and double push button.
One entry listed is located at bottom.
Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
KILLARK CONTROLS
HKH SERIES
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
C
C
O
O
Z
Z
L
L
HKH MAINTAINED MUSHROOM STAY PUT E-STOP
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2M41EK8
(PULL R ELE ASE)
HKH1AND2M71EK8
(TWIST RELEASE)
HKH1ANDAM41E
(PULL R ELE ASE)
HKH1ANDAM71E
(TWIST RELEASE)
HKH1ANP2M41EK8
(PULL R ELE ASE)
HKH1ANP2M71EK8
(TWIST RELEASE)
HKH1ANPAM41E
(PULL R ELE ASE)
HKH1ANPAM71E
(TWIST RELEASE)
ENTRY SIZE
3/4” NPT SS HUB
M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
13
14
13
14
HKH DOUBLE MOMENTARY PUSH BUTTON, 1 N.O. START/1 N.C. STOP
CATALOG NUMBER
DIN RAIL MOUNT IEC NEMA
HKH1AND2P21K8 3/4” NPT SS HUB
HKH1ANDAP21
ENTRY SIZE
M20 CLEAR ANCE
HOLE
CONTACT ARRANGEMENT
13
14
CONTACT BLOCKS
1 N.O. / 1 N.C. RED
CONTACT BLOCKS
START/(I)/ BL ANK
1 N.O. / 1 N.C.
STOP/(O)/BLANK
BLACK: BLANK
BUTTON
COLOR
BUTTON
COLOR
GREEN:
RED:
LEGEND
PLATE
MARKING
EMERGENCY
STOP
LEGEND
PLATE
MARKING
Page 5
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
STANDARD SIZE 1a NON-METALLIC CONFIGURATIONS
Selector Switch Maint. & Mom.
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations of rotary selector switches.
One entry listed is located at bottom.
2 Position
Selector Switch Maint. & Mom.
HKH MAINTAINED 2-POSITION SELECTOR SWITCH
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2S11SK8 HKH1ANP2S11SK8 3/4” NPT SS HUB
HKH1ANDAS11S HKH1ANPAS11S M20 CLEARANCE HOLE
HKH 2-POSITION SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. LEFT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2S210K8 HKH1ANP2S210K8 3/4” NPT SS HUB
HKH1ANDAS210 HKH1ANPAS210 M20 CLEARANCE HOLE
HKH MAINTAINED 3-POSITION SELECTOR SWITCH INDEPENDENT CAM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2S349K8 HKH1ANP2S349K8 3/4” NPT SS HUB
HKH1ANDAS349 HKH1ANPAS349 M20 CLEARANCE HOLE
HKH 3-POSITION SELECTOR SWITCH SPRING RETURN, MOM. LEFT & RIGHT, MAINT. CENTER
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2S440K8 HKH1ANP2S440K8 3/4” NPT SS HUB
HKH1ANDAS440 HKH1ANPAS440 M20 CLEARANCE HOLE
HKH 3-POSITION SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. CENTER & LEFT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2S540K8 HKH1ANP2S540K8 3/4” NPT SS HUB
HKH1ANDAS540 HKH1ANPAS540 M20 CLEARANCE HOLE
HKH 3-POSITION SELECTOR SWITCH SPRING RETURN, MOM. LEFT, MAINT. CENTER & RIGHT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2S640K8 HKH1ANP2S640K8 3/4” NPT SS HUB
HKH1ANDAS640 HKH1ANPAS640 M20 CLEARANCE HOLE
3 Position
ENTRY SIZE
ENTRY SIZE
ENTRY SIZE
ENTRY SIZE
ENTRY SIZE
ENTRY SIZE
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
CONTACT ARRANGEMENT
141312
CONTACT ARRANGEMENT
141312
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT BLOCKS
1 N.C. / 1 N.O. OFF-ON
CONTACT BLOCKS
1 N.C. / 1 N.O. BLANK
CONTACT BLOCKS
2 N.O. HAND-OFF-AUTO
CONTACT BLOCKS
2 N.O. BLANK
CONTACT BLOCKS
2 N.O. BLANK
CONTACT BLOCKS
2 N.O. BLANK
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
Page 6
STANDARD SIZE 1a NON-METALLIC CONFIGURATIONS
Key Selector SWT Maint. & Mom.
2 Position
Key Selector SWT Maint. & Mom.
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations of keyed rotary selector switches.
One entry hole listed is located at bottom.
HKH MAINTAINED 2-POSITION KEYED SELECTOR SWITCH
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2K11SK8 HKH1ANP2K11SK8 3/4” NPT SS HUB
HKH1ANDAK11S HKH1ANPAK11S
HKH 2-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. LEFT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2K210K8 HKH1ANP2K210K8 3/4” NPT SS HUB
HKH1ANDAK210 HKH1ANPAK210
HKH MAINTAINED 3-POSITION KEYED SELECTOR SWITCH INDEPENDENT CAM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2K349K8 HKH1ANP2K349K8 3/4” NPT SS HUB
HKH1ANDAK349 HKH1ANPAK349
HKH 3-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. LEFT & RIGHT, MAINT. CENTER
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2K440K8 HKH1ANP2K440K8 3/4” NPT SS HUB
HKH1ANDAK440 HKH1ANPAK440
HKH 3-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. CENTER & LEFT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2K540K8 HKH1ANP2K540K8 3/4” NPT SS HUB
HKH1ANDAK540 HKH1ANPAK540
HKH 3-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. LEFT, MAINT. CENTER & RIGHT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1AND2K640K8 HKH1ANP2K640K8 3/4” NPT SS HUB
HKH1ANDAK640 HKH1ANPAK640
3 Position
ENTRY SIZE
M20 CLEAR ANCE
HOLE
ENTRY SIZE
M20 CLEAR ANCE
HOLE
ENTRY SIZE
M20 CLEAR ANCE
HOLE
ENTRY SIZE
M20 CLEAR ANCE
HOLE
ENTRY SIZE
M20 CLEAR ANCE
HOLE
ENTRY SIZE
M20 CLEAR ANCE
HOLE
CONTACT ARRANGEMENT
141312
CONTACT ARRANGEMENT
141312
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
KILLARK CONTROLS
O
O
C
C
HKH SERIES
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
CONTACT BLOCKS LEGEND PLATE MARKING
1 N.C. / 1 N.O. OFF-ON
CONTACT BLOCKS LEGEND PLATE MARKING
1 N.C. / 1 N.O. BLANK
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. HAND-OFF-AUTO
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. BLANK
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. BLANK
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. BLANK
H
H
R
R
T
T
O
O
N
N
L
L
S
S
C
C
O
O
Z
Z
L
L
Page 7
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
STANDARD SIZE 1b NON-METALLIC CONFIGURATIONS
Momentary
Push Button
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations, including combinations of pilot lights and push buttons.
One entry listed is located at bottom.
Momentary
Mushroom P.B.
Momentary
Start-Stop
Push Buttons
Pilot Light
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
HKH MOMENTARY SINGLE PUSH BUTTON
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2P11K8 HKH1BNP2P11K8 3/4” NPT SS HUB
HKH1BNDAP11 HKH1BNPAP11 M20 CLEARANCE HOLE
SUPPLIED WITH 7 COLORED AND M ARKED DISCS – SEE BUTTON COLOR
ENTRY SIZE
CONTACT ARRANGEMENT
13
14
HKH MOMENTARY SINGLE PUSH BUTTON - MUSHROOM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2M11BK8 HKH1BND2M21AK8 HKH1BND2M310K8
HKH1BNDAM 11B HKH1BNDAM21A HKH1BNDAM310
HKH1BNP2M11BK8 HKH1BNP2M21AK8 HKH1BNP2M310K8
HKH1BNPAM11B
HKH1BNPAM21A
HKH1BNPAM310
ENTRY SIZE
3/4” NPT SS HUB
M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
13
14
HKH DOUBLE MOMENTARY START-STOP PUSH BUTTONS
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH 1BND2P 11P11K8 HKH1BNP2P11P11K8 3/4” NPT SS HUB
HKH1BNDAP11P11 HKH1BNPAP11P11
ENTRY SIZE
M20 CLEAR ANCE
HOLE
CONTACT ARRANGEMENT
CONTACT
BLOCKS
1 N.O. / 1 N.C.
CONTACT
BLOCKS
1 N.O. / 1 N.C.
CONTACT BLOCKS
1 N.O. / 1 N.C. 1 N.O. / 1 N.C.
BUTTON
COLOR
GREEN:
START/(I)/ BL ANK
RED:
STOP/(O)/BLANK
BLACK: BLANK
BUTTON
COLOR
RED GREEN BLACK
RED GREEN BLACK
BUTTON
COLOR
GREEN,
STAR T, ( I)
RED,
ST O P, (O)
LEGEND PLATE
MARKING
NONE
LEGEND PLATE
MARKING
STOP START BLANK
STOP START BLANK
LEGEND
PLATE
MARKING
HKH SINGLE PILOT LIGHT
3/4” NPT SS HUB SUPPLIED M20 CLEARANCE HOLE SUPPLIED CONTACT ARRANGEMENT
DIN RAIL MOUNT PANEL MOUNT DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2LRL0K8 HKH1BND2LGL0K8 HKH1BND2LAL0K8 HKH1BND2LCL0K8 HKH1BND2LBL0K8
HKH1BNP2LRL0K8 HKH1BNP2LGL0K8 HKH1BNP2LAL0K8 HKH1BNP2LCL0K8 HKH1BNP2LBL0K8
HKH1BNDALRL0 HKH1BNDALGL0 HKH1BNDALAL0 HKH1BNDALCL0 HKH1BNDALBL0
HKH1BNPALRL0 HKH1BNPALGL0 HKH1BNPALAL0 HKH1BNPALCL0 HKH1BNPALBL0
LA MP VOLTAGE COLOR
12V-254V AC/DC
IEC EX
12V-250V AC/DC
UL
RED LED GREEN LED AMBER LED
CLEAR LED
BLUE LED
LEGEND PLATE
MARKING
BLANK
Page 8
STANDARD SIZE 1b NON-METALLIC CONFIGURATIONS
Maintained
Mushroom P.B.
Pull Release
Maintained
Mushroom P.B.
Twist Release
Double
Pilot Light
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations, including combinations of pilot lights and push buttons.
One entry listed is located at bottom.
Pilot Light &
Double Momentary
Push Button
KILLARK CONTROLS
O
O
C
C
HKH SERIES
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
H
H
R
R
T
T
O
O
N
N
L
L
S
S
C
C
O
O
Z
Z
L
L
HKH MAINTAINED MUSHROOM STAY PUT E-STOP
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2M41EK8
(PULL R ELE ASE)
HKH1BND2M71EK8
(TWIST RELEASE)
HKH1BNDAM41E
(PULL R ELE ASE)
HKH1BNDAM71E
(TWIST RELEASE)
HKH1BNP2M41EK8
(PULL R ELE ASE)
HKH1BNP2M71EK8
(TWIST RELEASE)
HKH1BNPAM41E
(PULL R ELE ASE)
HKH1BNPAM71E
(TWIST RELEASE)
ENTRY SIZE
3/4” NPT SS HUB
M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
13
14
13
14
HKH MAINTAINED SINGLE PUSH PULL BUTTON - MUSHROOM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2M41BK8 HKH1BND2M51AK8 HKH1BND2M610K8
HKH1BNDAM 41B HKH1BNDAM51A HKH1BNDAM610
HKH1BNP2M41BK8 HKH1BNP2M51AK8 HKH1BNP2M610K8
HKH1BNPAM41B HKH1BNPAM51A HKH1BNPAM610
ENTRY SIZE
3/4” NPT SS HUB
M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
13
14
HKH DOUBLE PILOT LIGHT
3/4” NPT SS HUB SUPPLIED M20 CLEARANCE HOLE SUPPLIED CONTACT ARRANGEMENT
DIN RAIL MOUNT PANEL MOUNT DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2LRL0LGL0K8 HKH1BND2LRL0LRL0K8 HKH1BND2LGL0LGL0K8
HKH1BNP2LRL0LGL0K8 HKH1BNP2LRL0LRL0K8 HKH1BNP2LGL0LGL0K8
HKH1BNDALRL0LGL0 HKH1BNDALRL0LRL0 HKH1BNDALGL0LGL0
HKH1BNPALRL0LGL0 HKH1BNPALRL0LRL0 HKH1BNPALGL0LGL0
CONTACT
BLOCKS
1 N.O. / 1 N.C. RED
CONTACT
BLOCKS
1 N.O. / 1 N.C.
BUTTON
COLOR
BUTTON
COLOR
RED GREEN BLACK
RED GREEN BLACK
LA MP VOLTAGE COLOR
12V-254V AC/DC
IEC EX
12V-250V AC/DC
UL
RED/GREEN
RED/RED
GREEN/GREEN
LEGEND PLATE
MARKING
EMERGENCY
STOP
LEGEND PLATE
MARKING
STOP START BLANK
STOP START BLANK
LEGEND PLATE
MARKING
BLANK
HKH DOUBLE MOMENTARY PUSH BUTTON & PILOT LIGHT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2LRL0P21K8 HKH1BNP2LRL0P21K8 3/4” NPT SS HUB
HKH1BNDALRL0P21 HKH1BNPALRL0P21 M20 CLEARANCE HOLE
ENTRY SIZE
CONTACT ARRANGEMENT
13
14
LA MP VOLTAGE
12V-254V, AC/DC
CONTACT
BLOCKS
1 N.O. 1 N.C.
BUTTON
COLOR
GREEN,
STAR T, ( I)
RED,
ST O P, (O)
LEGEND PLATE
MARKING
Page 9
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
STANDARD SIZE 1b NON-METALLIC CONFIGURATIONS
2 Position
Selector Switch
Maint. & Mom.
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations of rotary selector switches.
One entry listed is located at bottom.
HKH MAINTAINED 2-POSITION SELECTOR SWITCH
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2S11SK8 HKH1BNP2S11SK8 3/4” NPT SS HUB
HKH1BNDAS11S HKH1BNPAS11S M20 CLEARANCE HOLE
HKH 2-POSITION SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. LEFT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2S210K8 HKH1BNP2S210K8 3/4” NPT SS HUB
HKH1BNDAS210 HKH1BNPAS210 M20 CLEARANCE HOLE
HKH MAINTAINED 3-POSITION SELECTOR SWITCH INDEPENDENT CAM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2S349K8 HKH1BNP2S349K8 3/4” NPT SS HUB
HKH1BNDAS349 HKH1BNPAS349 M20 CLEARANCE HOLE
HKH 3-POSITION SELECTOR SWITCH SPRING RETURN, MOM. LEFT & RIGHT, MAINT. CENTER
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2S440K8 HKH1BNP2S440K8 3/4” NPT SS HUB
HKH1BNDAS440 HKH1BNPAS440 M20 CLEARANCE HOLE
HKH 3-POSITION SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. CENTER & LEFT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2S540K8 HKH1BNP2S540K8 3/4” NPT SS HUB
HKH1BNDAS540 HKH1BNPAS540 M20 CLEARANCE HOLE
HKH 3-POSITION SELECTOR SWITCH SPRING RETURN, MOM. LEFT, MAINT. CENTER & RIGHT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2S640K8 HKH1BNP2S640K8 3/4” NPT SS HUB
HKH1BNDAS640 HKH1BNPAS640 M20 CLEARANCE HOLE
3 Position
Selector Switch
Maint. & Mom.
ENTRY SIZE
ENTRY SIZE
ENTRY SIZE
ENTRY SIZE
ENTRY SIZE
ENTRY SIZE
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
CONTACT ARRANGEMENT
141312
CONTACT ARRANGEMENT
141312
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT BLOCKS
1 N.C. / 1 N.O. OFF-ON
CONTACT BLOCKS
1 N.C. / 1 N.O. BLANK
CONTACT BLOCKS
2 N.O. HAND-OFF-AUTO
CONTACT BLOCKS
2 N.O. BLANK
CONTACT BLOCKS
2 N.O. BLANK
CONTACT BLOCKS
2 N.O. BLANK
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
Page 10
STANDARD SIZE 1b NON-METALLIC CONFIGURATIONS
2 Position
Key Selector SWT
Maint. & Mom.
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations of keyed rotary selector switches.
One entry hole listed is located at bottom.
HKH MAINTAINED 2-POSITION KEYED SELECTOR SWITCH
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2K11SK8 HKH1BNP2K11SK8 3/4” NP T SS HUB
HKH1BNDAK11S HKH1BNPAK11S
ENTRY SIZE
M20 CLEAR ANCE
HOLE
HKH 2-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. LEFT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2K210K8 HKH1BNP2K210K8 3/4” NPT SS HUB
HKH1BNDAK210 HKH1BNPAK210
ENTRY SIZE
M20 CLEAR ANCE
HOLE
HKH MAINTAINED 3-POSITION KEYED SELECTOR SWITCH INDEPENDENT CAM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2K349K8 HKH1BNP2K349K8 3/4” NPT SS HUB
HKH1BNDAK349 HKH1BNPAK349
ENTRY SIZE
M20 CLEAR ANCE
HOLE
HKH 3-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. LEFT & RIGHT, MAINT. CENTER
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2K440K8 HKH1BNP2K440K8 3/4” NPT SS HUB
HKH1BNDAK440 HKH1BNPAK440
ENTRY SIZE
M20 CLEAR ANCE
HOLE
HKH 3-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. CENTER & LEFT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2K540K8 HKH1BNP2K540K8 3/4” NPT SS HUB
HKH1BNDAK540 HKH1BNPAK540
ENTRY SIZE
M20 CLEAR ANCE
HOLE
HKH 3-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. LEFT, MAINT. CENTER & RIGHT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BND2K640K8 HKH1BNP2K640K8 3 /4” NPT SS HUB
HKH1BNDAK640 HKH1BNPAK640
ENTRY SIZE
M20 CLEAR ANCE
HOLE
3 Position
Key Selector SWT
Maint. & Mom.
CONTACT ARRANGEMENT
141312
CONTACT ARRANGEMENT
141312
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
KILLARK CONTROLS
O
O
C
C
HKH SERIES
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
CONTACT BLOCKS LEGEND PLATE MARKING
1 N.C. / 1 N.O. OFF-ON
CONTACT BLOCKS LEGEND PLATE MARKING
1 N.C. / 1 N.O. BLANK
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. HAND-OFF-AUTO
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. BLANK
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. BLANK
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. BLANK
H
H
R
R
T
T
O
O
N
N
L
L
S
S
C
C
O
O
Z
Z
L
L
Page 11
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
STANDARD SIZE 1c NON-METALLIC CONFIGURATIONS
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations, including combinations of pilot lights, push buttons, rotary selector switches and ammeter.
One entry hole listed is located at bottom.
HKH RED PILOT LIGHT & TWO MOMENTARY PUSH BUTTONS
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
ENTRY SIZE
HKHMOD000001 HKHMOD000002 3/4” NPT SS HUB
HKHMOD000003 HKHMOD000004 M20 CLEARANCE HOLE 1 N.O.
HKH THREE MOMENTARY PUSH BUTTONS
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKHMOD000005 HKHMOD000006 3/4” NPT SS HUB
HKHMOD000007 HKHMOD000008 M20 CLEARANCE HOLE
ENTRY SIZE
CONTACT ARRANGEMENT
13
14
CONTACT ARRANGEMENT
13
14
13
14
13
14
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
LA MP VOLTAGE
12V-254V AC/DC
IEC EX
12V-250V AC/DC
UL
CONTACT BLOCKS
1 N.O. / 1 N.C. 1 N.O. / 1 N.C. 1 N.O. / 1 N.C.
CONTACT
BLOCKS
1 N.C.
BUTTON
COLOR
GREEN:
START/(I)/ BL ANK
RED:
STOP/(O)/BLANK
BLACK: BLANK
BUTTON
COLOR
RED
STOP
(I)
GREEN
START
(O)
LEGEND PLATE
MARKING
BLANK
LEGEND PLATE
MARKING
BLANK
HKH RED PILOT LIGHT, MUSHROOM MAINTAINED P.B., DOUBLE MOMENTARY P.B.
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA CONTACT BLOCKS
HKHMOD000009
(PULL R ELE ASE)
HKHMOD000011
(TWIST RELEASE)
HKHMOD000013
(PULL R ELE ASE)
HKHMOD000015
(TWIST RELEASE)
HKHMOD000010
(PULL R ELE ASE)
HKHMOD000012
(TWIST RELEASE)
HKHMOD000014
(PULL R ELE ASE)
HKHMOD000016
(TWIST RELEASE)
ENTRY SIZE
3/4” NPT SS HUB
M20 CLEARANCE HOLE
CONTACT ARRANGEMENT LAMP VOLTAGE
13
14
13
14
13
14
12V-254V AC/DC
IEC EX
12V-250V AC/DC
UL 1 N.O. / 1 N.C. 1 N.O. / 1 N.C.
HKH 72MM AMMETER & 2 POSITION MAINT. SELECTOR SWITCH
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
ENTRY SIZE
HKHMOD000017 HKHMOD000018 3/4” NPT SS HUB
HKHMOD000019 HKHMOD000020 M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
141312
CONTACT BLOCKS
1 N.C. / 1 N.O. BLANK
BUTTON
COLOR
RED
GREEN:
START/(I)/ BL ANK
RED:
STOP/(O)/BLANK
BUTTON
COLOR
LEGEND PLATE
MARKING
BLANK
EMERGENCY
STOP
LEGEND PLATE
MARKING
Page 12
KILLARK CONTROLS
[
3.95 [100.3]
4.16 [105.7]
HKH SERIES
DIMENSIONAL DATA - SIZE 1 NON-METALLIC ENCLOSURES
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
C
C
O
O
Z
Z
L
L
4.21
[106.9]
Ø .24
[6.1]
2.20
[55.9]
3.95 [100.3]
3.27 [83.1]
.24
[6.1]
6.08
[154.4]
.24
[6.1]
4.09
[103.9]
3.95 [100.3]
3.27 [83.1]
.24
[6.1]
SI ZE 1A
SIZE 1B
CLEARANCE HOLE FOR NPT FITTING
1/2” TOP FEED 7 1/2” BOTTOM FEED 1 1/2” FEED THROUGH 4 3/4” TOP FEED 8 3/4” BOT TOM FEED 2 3/4” FEED THROUGH 5
.24
[6.1]
3.27 [83.1]
CLEARANCE HOLE FOR METRIC FITTING
7.96
202.2]
5.98
[151.9]
.24
[6.1]
M20 TOP FEED C M20 BOTTOM FEED A M20 FEED THROUGH B 2 X M20 TOP FEED F 2 X M20 BOTTOM FEED D M25 TOP FEED J M25 BOTTOM FEED G M25 FEED THROUGH H
LOGIC CODE
LOGIC CODE
SIZE 1C
.30
[7.6]
Page 13
KILLARK CONTROLS
5.48 [139.2]
]
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
SIZE 2a & 2c NON-METALLIC
FEATURES-SPECIFICATIONS
Size 2a and 2c control stations can be factory ordered to include combinations of pilot lights, push buttons, rotary selector switches, ammeters and terminal blocks.
Entry holes can be located on all sides.
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
4.80 [121.9]
5.48 [139.2]
4.80 [121.9]
4.57
8.45
[214.6]
Entry sizes available: Clearance hole sizes for 1/2”, 3/4” and 1” NPT Clearance hole sizes for M20, M25 and M32 Drilled and tapped holes for M20, M25 and M32
[116.1]
Size 2a
4.16 [105.7]
.30
[7.6]
CLEARANCE HOLE FOR NPT FITTING
1/2” TOP FEED 7 1/2” BOTTOM FEED 1 1/2” FEED THROUGH 4 3/4” TOP FEED 8 3/4” BOT TOM FEED 2 3/4” FEED THROUGH 5 1” TOP FEED 9 1” BOTTOM FEED 3 1” FEED THROUGH 6
LOGIC CODE
.24
[6.1]
11.78
[299.2]
9.24
[234.7]
(Depth same as 2a)
CLEARANCE HOLE FOR METRIC FITTING
M20 TOP FEED C M20 BOTTOM FEED A M20 FEED THROUGH B 2 X M20 TOP FEED F 2 X M20 BOTTOM FEED D M25 TOP FEED J M25 BOTTOM FEED G M25 FEED THROUGH H 2 X M25 BOTTOM FEED K
.24
[6.1
Size 2c
LOGIC CODE
Page 14
SIZE 1 NON-METALLIC 2 POLE ROCKER SWITCH
FEATURES-SPECIFICATIONS
Rocker Switch Single Throw Double Pole
Luminous fluorescent strip supplied for ease of locating.
One entry listed is located at bottom.
KILLARK CONTROLS
HKH SERIES
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4 Gb
0539 II 2 D Ex tb IIIC T4 Db IP66
DEMKO 15 ATEX 1405X Ex de IIC Gb Ex tb IIIC Db IP66 IECE x UL 15.0054X Ambient Range: -45ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC Gb / Ex de IIC Gb X Zone 21, AEx tb IIIC Db IP6 6 / Ex tb IIIC Db IP6 6 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -45ºC < Ta < 60ºC
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
C
C
O
O
Z
Z
L
L
Contact Block Features:
UL Electrical Rating: 690Vac, 20A, 50-60Hz, 60Vdc, 5A, 110Vdc, 2A, 255Vdc, 1.5A, 1/2
HP @120Vac, 1 HP@208/240/277Vac, A600/P600- Pilot Duty 350Vac- Tungsten Lamp.
Wire Allowances: WIRE RANGE with 1 or 2 WIRES: #22 to #12 AWG (SOL & STR) and
#10 AWG (STR).
IEC Electrical Ratings: AC690V 16A AC-12, 50-60 Hz, AC230V 16A AC-15, 50-60Hz,
DC60V 5A DC-12, DC125 1A DC-12.
Wire Allowances: WIRE RANGE with 1 or 2 WIRES: 0.5 to 2.5mm (SOL & STR) and
4.0mm
2
(STR)
Silver Alloy contacts with Gold Flashing.
HKH ROCKER SWITCH MAINTAINED IN 2 POSITIONS
CATALOG NUMBER
DIN RAIL MOUNT IEC NEMA
HKH1AND2RS4K8 3/4” NPT SS HUB
HKH1ANDARS4 M20 CLEARANCE HOLE
ENTRY SIZE
CONTACT ARRANGEMENT
141314
13
HKH ROCKER SWITCH MAINTAINED IN 2 POSITIONS
CATALOG NUMBER
DIN RAIL MOUNT IEC NEMA
HKH1AND2RS1K8 3/4” NPT SS HUB
HKH1ANDARS1 M20 CLEARANCE HOLE
ENTRY SIZE
CONTACT ARRANGEMENT
141312
Enclosure depth 4.5” (114mm)
CONTACT BLOCKS
2 N.O.
CONTACT BLOCKS
1 N.C. / 1 N.O.
Page 15
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
STAINLESS STEEL PANEL MOUNT
Stainless Steel
Washer
Actuator
Stainless Steel
Cover Screws
Optional
Legend Plate
Panel Mount
Cover Screw
Retaining Washer
Bracket
(view shown as ange-out)
Explosion
Protective LED
Pilot Light
Locknut
Spacer
Silicone Sealing
Washer
Explosion Protected
Contact Block
Conduit Hub or
Cable Connector
Applications
Hazardous and corrosive environments
due to the presence of flammable gases or vapors, combustible dusts or ignitable fiber or flyings.
Installations at petroleum refineries,
chemical and petrochemical plants and other processing or storage facilities where similar hazards exist.
Use in conjunction with motor starters or
contactors for remote control of motors.
Complies with RoHS, WEEE, ATEX, EMC and Low Voltage directives.
Materials
316 Stainless Steel also available with a
Standard internal flange and an external flange version when additional access is required.
Silicone gasketing on all enclosures and
operators throughout.
Features
Size 1 Control Stations available as 1a,
1b, & 1c as standard catalog number offerings for 1, 2 & 3 device openings and will accept 2-M20 entries in either end. Ammeters available in 1b & 1c. Size 2 Enclosures available as 2a & 2c for 2, 4 & 6 device entries in cover with ability to accept 2-M25 entries in either end.
Operating Temperature of -50ºC to +60ºC
Explosion Protected contact blocks 690VAC
N.O. & N.C. capable of 20 Amps for Switching Duty and HP Ratings up to 1HP.
LED Pilot Light modules for 12-250V AC/
DC for UL applications. 12-254V AC/DC for IEC applications.
Contacts & Pilot lights can be mounted
inside enclosure on Din Rail or in cover to the actuator.
Accessories available for Lockout/Tag Out
functions made in 316 stainless steel.
Page 16
Stainless Steel
Washer
Optional
Legend Plate
STAINLESS STEEL DIN RAIL MOUNT
Component
Explosion Protective
LED Pilot Light
Cover Screw
Retaining Washer
Mounting Rail
Explosion Protected
KILLARK CONTROLS
Contact Block
HKH SERIES
Conduit Hub or
Cable Connector
N
N
O
O
C
C
H
H
Mounting
Slot
R
R
T
T
O
O
L
L
S
S
C
C
O
O
Z
Z
L
L
Actuator
Stainless Steel
Cover Screws
Applications
Hazardous and corrosive environments
due to the presence of flammable gases or vapors, combustible dusts or ignitable fiber or flyings.
Installations at petroleum refineries,
chemical and petrochemical plants and other processing or storage facilities where similar hazards exist.
Use in conjunction with motor starters or
contactors for remote control of motors.
Complies with RoHS, WEEE, ATEX, EMC and Low Voltage directives.
Spacer
Silicone Sealing
Washer
(view shown as ange-in)
Materials
316 Stainless Steel also available with a
Standard internal flange and an external flange version when additional access is required.
Silicone gasketing on all enclosures and
operators throughout.
Locknut
Features
Size 1 Control Stations available as 1a,
1b, & 1c as standard catalog number offerings for 1, 2 & 3 device openings and will accept 2-M20 entries in either end. Ammeters available in 1b & 1c. Size 2 Enclosures available as 2a & 2c for 2, 4 & 6 device entries in cover with ability to accept 2-M25 entries in either end.
Operating Temperature of -50ºC to +60ºC
Explosion Protected contact blocks 690VAC
N.O. & N.C. capable of 20 Amps for Switching Duty and HP Ratings up to 1HP.
LED Pilot Light modules for 12-250V AC/
DC for UL applications. 12-254V AC/DC for IEC applications.
Contacts & Pilot lights can be mounted
inside enclosure on Din Rail or in cover to the actuator.
Accessories available for Lockout/Tag Out
functions made in 316 stainless steel.
Page 17
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
STANDARD SIZE 1a STAINLESS STEEL CONFIGURATIONS
Momentary
Push Button
Momentary & Maintained
Mushroom P.B.
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations of pilot lights and push buttons.
One entry hole listed is located at bottom.
Pilot Light
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
HKH MOMENTARY SINGLE PUSH BUTTON
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2P11K8 HKH1ASP2P11K8 3/4” NPT SS HUB
HKH1ASDAP11 HKH1ASPAP11 M20 CLEARANCE HOLE
SUPPLIED WITH 7 COLORED AND M ARKED DISCS – SEE BUTTON COLOR
ENTRY SIZE
CONTACT ARRANGEMENT
13
14
HKH MOMENTARY SINGLE PUSH BUTTON - MUSHROOM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2M11BK8 HKH1ASD2M21AK8 HKH1ASD2M310K8
HKH1ASDAM11B HKH1ASDAM21A HKH1ASDAM310
HKH1ASP2M11BK8
HKH1ASP2M21AK8
HKH1ASP2M310K8
HKH1ASPAM11B
HKH1ASPAM21A
HKH1ASPAM310
ENTRY SIZE
3/4” NPT SS HUB
M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
13
14
HKH MAINTAINED SINGLE PUSH PULL BUTTON - MUSHROOM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2M41BK8 HKH1ASD2M51AK8 HKH1ASD2M610K8
HKH1ASDAM41B HKH1ASDAM51A HKH1ASDAM610
HKH1ASP2M41BK8
HKH1ASP2M51AK8
HKH1ASP2M610K8
HKH1ASPAM41B
HKH1ASPAM51A
HKH1ASPAM610
ENTRY SIZE
3/4” NPT SS HUB
M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
13
14
CONTACT
BLOCKS
1 N.O. / 1 N.C.
CONTACT
BLOCKS
1 N.O. / 1 N.C.
CONTACT
BLOCKS
1 N.O. / 1 N.C.
BUTTON
COLOR
GREEN:
START/(I)/ BL ANK
RED:
STOP/(O)/BLANK
BLACK: BLANK
BUTTON
COLOR
RED GREEN BLACK
RED GREEN BLACK
BUTTON
COLOR
RED GREEN BLACK
RED GREEN BLACK
LEGEND PLATE
MARKING
NONE
LEGEND PLATE
MARKING
STOP START BLANK
STOP START BLANK
LEGEND PLATE
MARKING
STOP START BLANK
STOP START BLANK
HKH SINGLE PILOT LIGHT
3/4” NPT SS HUB SUPPLIED M20 CLEARANCE HOLE SUPPLIED CONTACT ARRANGEMENT
DIN RAIL MOUNT PANEL MOUNT DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2LRL0K8 HKH1ASD2LGL0K8 HKH1ASD2LAL0K8 HKH1ASD2LCL0K8 HKH1ASD2LBL0K8
HKH1ASP2LRL0K8 HKH1ASP2LGL0K8 HKH1ASP2LAL0K8 HKH1ASP2LCL0K8 HKH1ASP2LBL0K8
HKH1ASDALRL0 HKH1ASDALGL0 HKH1ASDALAL0 HKH1ASDALCL0 HKH1ASDALBL0
HKH1ASPALRL0 HKH1ASPALGL0 HKH1ASPALAL0 HKH1ASPALCL0 HKH1ASPALBL0
LA MP VOLTAGE COLOR
12V-254V AC/DC
IEC EX
12V-250V AC/DC
UL
RED LED GREEN LED AMBER LED CLEAR LED
BLUE LED
LEGEND PLATE
MARKING
BLANK
Page 18
STANDARD SIZE 1a STAINLESS STEEL CONFIGURATIONS
ATEX/IECEx Certified
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X
Maintained
Mushroom P.B.
Pull Release
Maintained
Mushroom P.B.
Twist Release
Double
Momentary
Push Button
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations of mushroom push buttons and double push button.
One entry listed is located at bottom.
Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
KILLARK CONTROLS
HKH SERIES
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
C
C
O
O
Z
Z
L
L
HKH MAINTAINED MUSHROOM STAY PUT E-STOP
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2M41EK8
(PULL R ELE ASE)
HKH1ASD2M71EK8
(TWIST RELEASE)
HKH1ASDAM41E
(PULL R ELE ASE)
HKH1ASDAM71E
(TWIST RELEASE)
HKH1ASP2M41EK8
(PULL R ELE ASE)
HKH1ASP2M71EK8
(TWIST RELEASE)
HKH1ASPAM41E
(PULL R ELE ASE)
HKH1ASPAM71E
(TWIST RELEASE)
ENTRY SIZE
3/4” NPT SS HUB
M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
13
14
13
14
HKH DOUBLE MOMENTARY PUSH BUTTON, 1 N.O. START/1 N.C. STOP
CATALOG NUMBER
DIN RAIL MOUNT IEC NEMA
HKH1ASD2P21K8 3/4” NPT SS HUB
HKH1ASDAP21
ENTRY SIZE
M20 CLEAR ANCE
HOLE
CONTACT ARRANGEMENT
13
14
CONTACT BLOCKS
1 N.O. / 1 N.C. RED
CONTACT BLOCKS
1 N.O. / 1 N.C.
START/(I)
RED/ STOP/(O)
BUTTON
COLOR
BUTTON
COLOR
GREEN/
BLACK
LEGEND
PLATE
MARKING
EMERGENCY
STOP
LEGEND
PLATE
MARKING
Page 19
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
STANDARD SIZE 1a STAINLESS STEEL CONFIGURATIONS
Selector Switch Maint. & Mom.
2 Position
Selector Switch Maint. & Mom.
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations of rotary selector switches.
One entry hole listed is located at bottom.
HKH MAINTAINED 2-POSITION SELECTOR SWITCH
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2S11SK8 HKH1ASP2S11SK8 3/4” NPT SS HUB
HKH1ASDAS11S HKH1ASPAS11S M20 CLEARANCE HOLE
HKH 2-POSITION SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. LEFT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2S210K8 HKH1ASP2S210K8 3/4” NPT SS HUB
HKH1ASDAS210 HKH1ASPAS210 M20 CLEARANCE HOLE
HKH MAINTAINED 3-POSITION SELECTOR SWITCH INDEPENDENT CAM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2S349K8 HKH1ASP2S349K8 3/4” NPT SS HUB
HKH1ASDAS349 HKH1ASPAS349 M20 CLEARANCE HOLE
HKH 3-POSITION SELECTOR SWITCH SPRING RETURN, MOM. LEFT & RIGHT, MAINT. CENTER
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2S440K8 HKH1ASP2S440K8 3/4” NPT SS HUB
HKH1ASDAS440 HKH1ASPAS440 M20 CLEARANCE HOLE
HKH 3-POSITION SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. CENTER & LEFT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2S540K8 HKH1ASP2S540K8 3/4” NPT SS HUB
HKH1ASDAS540 HKH1ASPAS540 M20 CLEARANCE HOLE
HKH 3-POSITION SELECTOR SWITCH SPRING RETURN, MOM. LEFT, MAINT. CENTER & RIGHT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2S640K8 HKH1ASP2S640K8 3/4” NPT SS HUB
HKH1ASDAS640 HKH1ASPAS640 M20 CLEARANCE HOLE
3 Position
ENTRY SIZE
ENTRY SIZE
ENTRY SIZE
ENTRY SIZE
ENTRY SIZE
ENTRY SIZE
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
CONTACT ARRANGEMENT
141312
CONTACT ARRANGEMENT
141312
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT BLOCKS
1 N.C. / 1 N.O. OFF-ON
CONTACT BLOCKS
1 N.C. / 1 N.O. BLANK
CONTACT BLOCKS
2 N.O. HAND-OFF-AUTO
CONTACT BLOCKS
2 N.O. BLANK
CONTACT BLOCKS
2 N.O. BLANK
CONTACT BLOCKS
2 N.O. BLANK
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
Page 20
STANDARD SIZE 1a STAINLESS STEEL CONFIGURATIONS
Key Selector SWT Maint. & Mom.
2 Position
Key Selector SWT Maint. & Mom.
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations of keyed rotary selector switches.
One entry hole listed is located at bottom.
HKH MAINTAINED 2-POSITION KEYED SELECTOR SWITCH
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2K11SK8 HKH1ASP2K11SK8 3/4” NPT SS HUB
HKH1ASDAK11S HKH1ASPAK11S
HKH 2-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. LEFT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2K210K8 HKH1ASP2K210K8 3/4” NPT SS HUB
HKH1ASDAK210 HKH1ASPAK210
HKH MAINTAINED 3-POSITION KEYED SELECTOR SWITCH INDEPENDENT CAM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2K349K8 HKH1ASP2K349K8 3/4” NPT SS HUB
HKH1ASDAK349 HKH1ASPAK349
HKH 3-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. LEFT & RIGHT, MAINT. CENTER
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2K440K8 HKH1ASP2K440K8 3/4” NPT SS HUB
HKH1ASDAK440 HKH1ASPAK440
HKH 3-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. CENTER & LEFT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2K540K8 HKH1ASP2K540K8 3/4” NPT SS HUB
HKH1ASDAK540 HKH1ASPAK540
HKH 3-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. LEFT, MAINT. CENTER & RIGHT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1ASD2K640K8 HKH1ASP2K640K8 3/4” NPT SS HUB
HKH1ASDAK640 HKH1ASPAK640
3 Position
ENTRY SIZE
M20 CLEAR ANCE
HOLE
ENTRY SIZE
M20 CLEAR ANCE
HOLE
ENTRY SIZE
M20 CLEAR ANCE
HOLE
ENTRY SIZE
M20 CLEAR ANCE
HOLE
ENTRY SIZE
M20 CLEAR ANCE
HOLE
ENTRY SIZE
M20 CLEAR ANCE
HOLE
CONTACT ARRANGEMENT
141312
CONTACT ARRANGEMENT
141312
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
CONTACT ARRANGEMENT
141314
13
KILLARK CONTROLS
O
O
C
C
HKH SERIES
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
CONTACT BLOCKS LEGEND PLATE MARKING
1 N.C. / 1 N.O. OFF-ON
CONTACT BLOCKS LEGEND PLATE MARKING
1 N.C. / 1 N.O. BLANK
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. HAND-OFF-AUTO
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. BLANK
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. BLANK
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. BLANK
H
H
R
R
T
T
O
O
N
N
L
L
S
S
C
C
O
O
Z
Z
L
L
Page 21
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
STANDARD SIZE 1b STAINLESS STEEL CONFIGURATIONS*
Momentary
Push Button
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations, including combinations of pilot lights and push buttons.
One entry hole listed is located at bottom.
Momentary
Mushroom P.B.
Momentary
Start-Stop
Push Buttons
Pilot Light
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
HKH MOMENTARY SINGLE PUSH BUTTON
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2P11K8 HKH1BSP2P11K8 3/4” NPT SS HUB
HKH1BSDAP11 HKH1BSPAP11 M20 CLEARANCE HOLE
SUPPLIED WITH 7 COLORED AND M ARKED DISCS – SEE BUTTON COLOR
ENTRY SIZE
CONTACT ARRANGEMENT
13
14
HKH MOMENTARY SINGLE PUSH BUTTON - MUSHROOM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2M 11BK8 HKH1BSD2M21AK8 HKH1BSD2M310K8
HKH1BSDAM11B HKH1BSDAM21A HKH1BSDAM310
HKH1BSP2M11BK 8 HKH1BSP2M21AK8 HKH1BSP2M310K8
HKH1BSPAM11B
HKH1BSPAM21A
HKH1BSPAM310
ENTRY SIZE
3/4” NPT SS HUB
M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
13
14
HKH DOUBLE MOMENTARY START-STOP PUSH BUTTONS
CATALOG NUMBERj
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH 1BSD2P11P11K8 HKH1BEP2P11P 11K8 3/4” NPT SS HUB
HKH1BSDAP 11P11 HKH1BEPAP11P11
ENTRY SIZE
M20 CLEAR ANCE
HOLE
CONTACT ARRANGEMENT
CONTACT
BLOCKS
1 N.O. / 1 N.C.
CONTACT
BLOCKS
1 N.O. / 1 N.C.
CONTACT BLOCKS
1 N.O. / 1 N.C. 1 N.O. / 1 N.C.
BUTTON
COLOR
GREEN:
START/(I)/ BL ANK
RED:
STOP/(O)/BLANK
BLACK: BLANK
BUTTON
COLOR
RED GREEN BLACK
RED GREEN BLACK
BUTTON
COLOR
GREEN,
STAR T, ( I)
RED,
ST O P, (O)
LEGEND PLATE
MARKING
NONE
LEGEND PLATE
MARKING
STOP START BLANK
STOP START BLANK
LEGEND
PLATE
MARKING
HKH SINGLE PILOT LIGHT
3/4” NPT SS HUB SUPPLIED M20 CLEARANCE HOLE SUPPLIED CONTACT ARRANGEMENT
DIN RAIL MOUNT PANEL MOUNT DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2LRL0K8 HKH1BSD2LGL0K8 HKH1BSD2LAL0K8 HKH1BSD2LCL0K8 HKH1BSD2LBL0K8
j Din Rail mount assemblies supplied in Flange In type enclosures.(S) Panel mount assemblies supplied with Flange Out enclosures.(E)
HKH1BSP2LRL0K8 HKH1BSP2LGL0K8 HKH1BSP2LAL0K8 HKH1BSP2LCL0K8 HKH1BSP2LBL0K8
HKH1BSDALRL0 HKH1BSDALGL0 HKH1BSDALAL0 HKH1BSDALCL0 HKH1BSDALBL0
HKH1BSPALRL0 HKH1BSPALGL0 HKH1BSPALAL0 HKH1BSPALCL0 HKH1BSPALBL0
LA MP VOLTAGE COLOR
12V-254V AC/DC
IEC EX
12V-250V AC/DC
UL
RED LED GREEN LED AMBER LED
CLEAR LED
BLUE LED
LEGEND PLATE
MARKING
BLANK
Page 22
STANDARD SIZE 1b STAINLESS STEEL CONFIGURATIONS*
Maintained
Mushroom P.B.
Pull Release
Maintained
Mushroom P.B.
Twist Release
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations, including combinations of pilot lights and push buttons.
One entry listed is located at bottom.
Double
Pilot Light
Pilot Light &
Double Momentary
Push Button
KILLARK CONTROLS
O
O
C
C
HKH SERIES
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
H
H
R
R
T
T
O
O
N
N
L
L
S
S
C
C
O
O
Z
Z
L
L
HKH MAINTAINED MUSHROOM STAY PUT E-STOP
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2M41EK8
(PULL R ELE ASE)
HKH1BSD2M71EK8
(TWIST RELEASE)
HKH1BSDAM41E
(PULL R ELE ASE)
HKH1BSDAM71E
(TWIST RELEASE)
HKH1BSP2M41EK8
(PULL R ELE ASE)
HKH1BSP2M71EK8
(TWIST RELEASE)
HKH1BSPAM41E
(PULL R ELE ASE)
HKH1BSPAM71E
(TWIST RELEASE)
ENTRY SIZE
3/4” NPT SS HUB
M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
13
14
13
14
HKH MAINTAINED SINGLE PUSH PULL BUTTON - MUSHROOM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2M 41BK8 HKH1BSD2M51AK8 HKH1BSD2M610K8
HKH1BSDAM41B HKH1BSDAM51A HKH1BSDAM610
HKH1BSP2M41BK8 HKH1BSP2M51AK8 HKH1BSP2M610K8
HKH1BSPAM 41B HKH1BSPAM51A HKH1BSPAM610
ENTRY SIZE
3/4” NPT SS HUB
M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
13
14
HKH DOUBLE PILOT LIGHT
3/4” NPT SS HUB SUPPLIEDj M20 CLEARANCE HOLE SUPPLIEDj
DIN RAIL MOUNT PANEL MOUNT DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2LRL0LGL0K8 HKH1BSD2LRL0LRL0K8 HKH1BSD2LGL0LGL0K8
HKH1BEP2LRL0LGL0K8 HKH1BEP2LRL0LRL0K8 HKH1BEP2LGL0LGL0K8
HKH1BSDALRL0LGL0 HKH1BSDALRL0LRL0 HKH1BSDALGL0LGL0
HKH1BEPALRL0LGL0 HKH1BEPALRL0LRL0 HKH1BEPALGL0LGL0
CONTACT ARRANGEMENT
CONTACT
BLOCKS
1 N.O. / 1 N.C. RED
CONTACT
BLOCKS
1 N.O. / 1 N.C.
BUTTON
COLOR
BUTTON
COLOR
RED GREEN BLACK
RED GREEN BLACK
LA MP VOLTAGE COLOR
12V-254V AC/DC
IEC EX
12V-250V AC/DC
UL
RED/GREEN
RED/RED
GREEN/GREEN
LEGEND PLATE
MARKING
EMERGENCY
STOP
LEGEND PLATE
MARKING
STOP START BLANK
STOP START BLANK
LEGEND PLATE
MARKING
BLANK
HKH DOUBLE MOMENTARY PUSH BUTTON & PILOT LIGHT
CATALOG NUMBERj
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2LRL0P21K8 HKH1BEP2LRL0P21K8 3/4” NPT SS HUB
HKH1BSDALRL0P21 HKH1BEPALRL0P21 M20 CLEARANCE HOLE
j Din Rail mount assemblies supplied in Flange In type enclosures.(S) Panel mount assemblies supplied with Flange Out enclosures.(E)
ENTRY SIZE
CONTACT ARRANGEMENT
13
14
LA MP VOLTAGE
12V-254V AC/DC
IEC EX
12V-250V AC/DC
UL
CONTACT
BLOCKS
1 N.O. 1 N.C.
BUTTON
COLOR
GREEN,
STAR T, ( I)
RED,
ST O P, (O)
LEGEND PLATE
MARKING
Page 23
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
STANDARD SIZE 1b STAINLESS STEEL CONFIGURATIONS
2 Position
Selector Switch
Maint. & Mom.
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations of rotary selector switches.
One entry listed is located at bottom.
3 Position
Selector Switch
Maint. & Mom.
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2S11SK8 HK H1BSP2S11SK8 3/4” NPT SS HUB
HKH1BSDAS 11S HK H1BSPA S11S M20 CLEARANCE HOLE
ENTRY SIZE
CONTACT ARRANGEMENT
141312
HKH 2-POSITION SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. LEFT
HKH MAINTAINED 2-POSITION SELECTOR SWITCH
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2S210K8 HKH1BSP2S210K8 3/4” NPT SS HUB
HKH1BSDAS210 HKH1BSPAS210 M20 CLEARANCE HOLE
ENTRY SIZE
CONTACT ARRANGEMENT
141312
HKH MAINTAINED 3-POSITION SELECTOR SWITCH INDEPENDENT CAM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2S349K8 HKH1BSP2S349K8 3/4” NPT SS HUB
HKH1BSDAS349 HKH1BSPAS349 M20 CLEARANCE HOLE
ENTRY SIZE
CONTACT ARRANGEMENT
141314
13
HKH 3-POSITION SELECTOR SWITCH SPRING RETURN, MOM. LEFT & RIGHT, MAINT. CENTER
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2S440K8 HKH1BSP2S440K8 3/4” NPT SS HUB
HKH1BSDAS 440 HKH1BSPAS 440 M20 CLEARANCE HOLE
ENTRY SIZE
CONTACT ARRANGEMENT
141314
13
HKH 3-POSITION SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. CENTER & LEFT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2S540K8 HKH1BSP2S540K8 3/4” NPT SS HUB
HKH1BSDAS 540 HKH1BSPAS 540 M20 CLEARANCE HOLE
ENTRY SIZE
CONTACT ARRANGEMENT
141314
13
HKH 3-POSITION SELECTOR SWITCH SPRING RETURN, MOM. LEFT, MAINT. CENTER & RIGHT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2S640K8 HKH1BSP2S640K8 3/4” NPT SS HUB
HKH1BSDAS 640 HKH1BSPAS 640 M20 CLEARANCE HOLE
ENTRY SIZE
CONTACT ARRANGEMENT
141314
13
CONTACT BLOCKS
1 N.C. / 1 N.O. OFF-ON
CONTACT BLOCKS
1 N.C. / 1 N.O. BLANK
CONTACT BLOCKS
2 N.O. HAND-OFF-AUTO
CONTACT BLOCKS
2 N.O. BLANK
CONTACT BLOCKS
2 N.O. BLANK
CONTACT BLOCKS
2 N.O. BLANK
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
LEGEND PLATE
MARKING
Page 24
STANDARD SIZE 1b STAINLESS STEEL CONFIGURATIONS
2 Position
Key Selector Sw t
Maint. & Mom.
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations of keyed rotary selector switches.
One entry listed is located at bottom.
3 Position
Key Selector Sw t
Maint. & Mom.
KILLARK CONTROLS
O
O
C
C
HKH SERIES
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
H
H
R
R
T
T
O
O
N
N
L
L
S
S
C
C
O
O
Z
Z
L
L
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2K11SK8 HKH1BSP2K11SK8 3/4” NPT SS HUB
HKH1BSDAK11S HKH1BSPAK11S
ENTRY SIZE
M20 CLEAR ANCE
HOLE
CONTACT ARRANGEMENT
141312
HKH 2-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. LEFT
HKH MAINTAINED 2-POSITION KEYED SELECTOR SWITCH
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2K210K8 HKH1BSP2K210K8 3/4” NPT SS HUB
HKH1BSDAK210 HKH1BSPAK210
ENTRY SIZE
M20 CLEAR ANCE
HOLE
CONTACT ARRANGEMENT
141312
HKH MAINTAINED 3-POSITION KEYED SELECTOR SWITCH INDEPENDENT CAM
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2K349K8 HKH1BSP2K349K8 3/4” NPT SS HUB
HKH1BSDAK349 HKH1BSPAK349
ENTRY SIZE
M20 CLEAR ANCE
HOLE
CONTACT ARRANGEMENT
141314
13
HKH 3-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. LEFT & RIGHT, MAINT. CENTER
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2K440K8 HKH1BSP2K440K8 3/4” NPT SS HUB
HKH1BSDAK440 HKH1BSPAK440
ENTRY SIZE
M20 CLEAR ANCE
HOLE
CONTACT ARRANGEMENT
141314
13
HKH 3-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. RIGHT, MAINT. CENTER & LEFT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2K540K8 HKH1BSP2K540K8 3/4” NPT SS HUB
HKH1BSDAK540 HKH1BSPAK540
ENTRY SIZE
M20 CLEAR ANCE
HOLE
CONTACT ARRANGEMENT
141314
13
HKH 3-POSITION KEYED SELECTOR SWITCH SPRING RETURN, MOM. LEFT, MAINT. CENTER & RIGHT
CATALOG NUMBER
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
HKH1BSD2K640K8 HKH1BSP2K640K8 3/4” NPT SS HUB
HKH1BSDAK640 HKH1BSPAK640
ENTRY SIZE
M20 CLEAR ANCE
HOLE
CONTACT ARRANGEMENT
141314
13
CONTACT BLOCKS LEGEND PLATE MARKING
1 N.C. / 1 N.O. OFF-ON
CONTACT BLOCKS LEGEND PLATE MARKING
1 N.C. / 1 N.O. BLANK
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. HAND-OFF-AUTO
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. BLANK
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. BLANK
CONTACT BLOCKS LEGEND PLATE MARKING
2 N.O. BLANK
Page 25
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
STANDARD SIZE 1c STAINLESS STEEL CONFIGURATIONS
FEATURES-SPECIFICATIONS
The control stations on this page are the most commonly used configurations, including combinations of pilot lights, push buttons, rotary selector switches and ammeters.
One entry hole listed is located at bottom.
HKH RED PILOT LIGHT & TWO MOMENTARY PUSH BUTTONS
CATALOG NUMBERj
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
ENTRY SIZE
HKHMOD000021 HKHMOD000022 3/4” NPT SS HUB
HKHMOD000023 HKHMOD000024 M20 CLEARANCE HOLE 1 N.O.
CONTACT ARRANGEMENT
13
14
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
LA MP VOLTAGE
12V-254V AC/DC
IEC EX
12V-250V AC/DC
UL
CONTACT
BLOCKS
1 N.C.
BUTTON
COLOR
RED
STOP
(I)
GREEN
START
(O)
LEGEND PLATE
MARKING
BLANK
HKH THREE MOMENTARY PUSH BUTTONS
CATALOG NUMBERj
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
ENTRY SIZE
HKHMOD000025 HKHMOD000026 3 /4” NPT SS HUB
HKHMOD000027 HKHMOD000028 M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
13
14
13
14
13
14
CONTACT BLOCKS
1 N.O. / 1 N.C. 1 N.O. / 1 N.C. 1 N.O. / 1 N.C.
HKH RED PILOT LIGHT, MUSHROOM MAINTAINED P.B., DOUBLE MOMENTARY P.B.
CATALOG NUMBERj
DIN RAIL MOUNT PANEL MOUNT IEC NEMA CONTACT BLOCKS
HKHMOD000029
(PULL R ELE ASE)
HKHMOD000031
(TWIST RELEASE)
HKHMOD000033
(PULL R ELE ASE)
HKHMOD000035
(TWIST RELEASE)
HKHMOD000030
(PULL R ELE ASE)
HKHMOD000032
(TWIST RELEASE)
HKHMOD000034
(PULL R ELE ASE)
HKHMOD000036
(TWIST RELEASE)
ENTRY SIZE
3/4” NPT SS HUB
M20 CLEARANCE HOLE
CONTACT ARRANGEMENT LAMP VOLTAGE
13
14
13
14
13
14
12V-254V AC/DC
IEC EX
12V-250V AC/DC
UL 1 N.O. / 1 N.C. 1 N.O. / 1 N.C.
HKH 72MM AMMETER & 2 POSITION MAINT. SELECTOR SWITCH
CATALOG NUMBERj
DIN RAIL MOUNT PANEL MOUNT IEC NEMA
ENTRY SIZE
HKHMOD000037 HKHMOD000038 3/4” NPT SS HUB
HKHMOD000039 HKHMOD000040 M20 CLEARANCE HOLE
CONTACT ARRANGEMENT
141312
CONTACT BLOCKS
1 N.C. / 1 N.O. BLANK
BUTTON
COLOR
GREEN:
START/(I)/ BL ANK
RED:
STOP/(O)/BLANK
BLACK: BLANK
BUTTON
COLOR
RED
GREEN:
START/(I)/ BL ANK
RED:
STOP/(O)/BLANK
BUTTON
COLOR
LEGEND PLATE
MARKING
BLANK
LEGEND PLATE
MARKING
BLANK
EMERGENCY
STOP
LEGEND PLATE
MARKING
j Din Rail mount assemblies supplied in Flange In type enclosures. Panel mount assemblies supplied with Flange Out enclosures.
Page 26
KILLARK CONTROLS
HKH SERIES
DIMENSIONAL DATA - STAINLESS STEEL SIZE 1 FLANGE IN
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
C
C
O
O
Z
Z
L
L
Flange In Size 1A
Flange In Size 1B
Flange In Size 1C
DIMENSIONAL DATA - STAINLESS STEEL SIZE 1 FLANGE OUT
Ø
.34 [9]
9.63 [244]
8.88 [225]
10.38 [264]
Flange Out Size 1A
Flange Out Size 1B
.34 [9]
6.25 [159]
5.38 [137]
4.63 [117]
Flange Out Size 1C
4.25 [108]
3.63 [92]
Entry sizes available: Clearance hole sizes for 1/2” and 3/4” Clearance hole sizes for M20, M25 and M32 Drilled and tapped holes for M20, M25 and M32
CLEARANCE HOLE FOR NPT FITTING
LOGIC CODE
1/2” TOP FEED 7 1/2” BOTTOM FEED 1 1/2” FEED THROUGH 4 3/4” TOP FEED 8 3/4” BOT TOM FEED 2 3/4” FEED THROUGH 5
CLEARANCE HOLE FOR METRIC FITTING
LOGIC CODE
M20 TOP FEED C M20 BOTTOM FEED A M20 FEED THROUGH B 2 X M20 TOP FEED F 2 X M20 BOTTOM FEED D M25 TOP FEED J M25 BOTTOM FEED G M25 FEED THROUGH H
Page 27
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
SIZE 2a & 2c STAINLESS STEEL FLANGE IN
FEATURES-SPECIFICATIONS
Size 2a and 2c control stations can be factory ordered to include combinations of pilot lights, push buttons, rotary selector switches, ammeters and terminal blocks.
Entry holes can be located on all sides.
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
Size 2a
Entry sizes available: Clearance hole sizes for 1/2”, 3/4” and 1” NPT Clearance hole sizes for M20, M25 and M32 Drilled and tapped holes for M20, M25 and M32
Size 2c
Page 28
SIZE 2a & 2c STAINLESS STEEL FLANGE OUT
FEATURES-SPECIFICATIONS
Size 2a and 2c control stations can be factory ordered to include combinations of pilot lights, push buttons, rotary selector switches, ammeters and terminal blocks.
Entry holes can be located on all sides.
KILLARK CONTROLS
O
O
C
C
HKH SERIES
ATEX/IECEx Certified
0539 II 2 G Ex de IIC T4/T5/ T6 Gb
0539 II 2 D Ex tb IIIC T4/ T5/T6 Db IP 66
DEMKO 15 ATEX 1405X Ex de IIC T4/ T5/T6 Gb Ex tb IIIC T4/ T5/T 6 Db IP 66 IECE x UL 15.0054X Ambient Range: -50ºC < Ta < 60ºC
cULus Certified
Class I, Zone 1, AEx de IIC T4/ T5/T6 Gb / Ex de IIC T4/T 5/ T6 Gb X Zone 21, AEx tb IIIC T4/T5/T6 Db IP66 / Ex tb IIIC T4/ T5/T6 Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL60079-0, -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -50ºC < Ta < 60ºC
H
H
R
R
T
T
O
O
N
N
L
L
S
S
C
C
O
O
Z
Z
L
L
Size 2a
Entry sizes available: Clearance hole sizes for 1/2”, 3/4” and 1” NPT Clearance hole sizes for M20, M25 and M32 Drilled and tapped holes for M20, M25 and M32
CLEARANCE HOLE FOR NPT FITTING
1/2” TOP FEED 7 1/2” BOTTOM FEED 1 1/2” FEED THROUGH 4 3/4” TOP FEED 8 3/4” BOT TOM FEED 2 3/4” FEED THROUGH 5 1” TOP FEED 9 1” BOTTOM FEED 3 1” FEED THROUGH 6
LOGIC CODE
Size 2c
CLEARANCE HOLE FOR METRIC FITTING
M20 TOP FEED C M20 BOTTOM FEED A M20 FEED THROUGH B 2 X M20 TOP FEED F 2 X M20 BOTTOM FEED D M25 TOP FEED J M25 BOTTOM FEED G M25 FEED THROUGH H 2 X M25 BOTTOM FEED K
LOGIC CODE
Page 29
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS
Actuator
FEATURES-SPECIFICATIONS
Panel Mount
Bracket
Sealing Washer
Explosion Protected
Contact Block
Locknut
Spacer**
Silicone
** Required on thin wall Panel only < .16”
thick. Refer to instruction sheet for actuator
ATEX/IECEx Certified
0539 II 2 G Ex e IIC Gb 0539 II 2 D Ex tb IIIC Db
IP66
-50ºC ≤ Ta ≤ 60 ºC DEMKO 14 ATEX 1400U Ex e IIC Gb Ex tb IIIC Db
-50°C ≤ Ta ≤ +60°C IECE x UL 14.0 104U
cULus Certified
Class I, Zone 1, AEx e IIC Gb / Ex e IIC Gb U Zone 21, AEx tb IIIC Db / Ex tb IIIC Db U Class I, Division 2, Groups A, B, C, D Class II, Div. 1, Groups E, F, G (Canada) Class II, Division 2, Groups E, F, G Class III
-50°C ≤ Ta ≤ +60°C Type 3/4/4X/12/13 IP66
Complete actuator catalog numbers with contacts for mounting to your panel with cover thickness from 0.04” to 0.25”.
MOMENTARY START/STOP PUSH BUTTONS
BASIC CATALOG NUMBERS DESCRIPTION
HKHPBMMSS1
MOMEN TARY PUSH BUT TON WITH 1 N.O. & 1 N.C. CONTACT – INCLUDES GRN START, GRN (I), RED STOP & RED O,
GREEN, RED & BLACK BL ANK DISC 7 HKHPMBRKT
MOMENTARY MUSHROOM HEAD PUSH BUTTONS
HKHPBMMMR1 MOMEN TARY MUSHROOM PB, RED WITH 1 N.O. & 1 N.C. CONTACT & HKHPMBRK T HKHPBMMMB1 MOMEN TARY MUSHROOM PB, BLACK WITH 1 N.O. & 1 N.C. CONTACT & HKHPMBRK T HKHPBMMMG1 MOMENTARY MUSHROOM PB, GREEN WITH 1 N.O. & 1 N.C. CONTACT & HKHPMBRK T
DOUBLE MOMENTARY PUSH BUTTON
HKHDBLPBMMGR1 DOUBLE MOMENTARY PUSH BUT TON, RED & GREEN BUT TONS WITH 1 N.O. & 1 N.C. & HKHPMBRKT
MAINTAINED MUSHROOM HEAD PUSH BUTTONS
HKHPBPMTMR1 MAINTAINED MUSHROOM PUSH/PULL PB, RED WITH 1 N.O. & 1 N.C. CONTACT & HK HPMBRKT HKHPBPMTMB1 MAINTAINED MUSHROOM PUSH/PULL PB, BL ACK WITH 1 N.O. & 1 N.C. CONTACT & HKHPMBRKT HKHPBPMTMG1 MAINTAINED MUSHROOM PUSH/PULL PB, GREEN WITH 1 N.O. & 1 N.C. CONTACT & HKHPMBRKT
HKHPBTMTMR1 MAINTAINED MUSHROOM PB TWIST RELEASE, RED WITH 1 N.O. & 1 N.C. CONTACT & HK HPMBRKT HKHPBKMTMRH1 MAINTAINED PUSH BUTTON KEY RELEASE, MUSHROOM RED HD, HORIZONTAL WITH 1 N.O. & 1 N.C. CONTACT & HKHPMBRKT HKHPBKMTMRV1 MAINTAINED PUSH BUT TON KEY RELEASE, MUSHROOM RED HD, VERTICAL WITH 1 N.O. & 1 N.C. CONTACT & HKHPMBRKT
PILOT LIGHT LENS ASSEMBLY
HKHPLRL PILOT LIGHT RED LENS ASSEMBLY WITH 12-254V AC/DC LAMP MODULE HKHPLGL PILOT LIGHT GREEN LENS ASSEMBLY WITH 12-25 4V AC/DC L AMP MODULE HKHPLAL PILOT LIGHT AMBER LENS ASSEMBLY WITH 12-254V AC/ DC LAMP MODULE HKHPLCL PILOT LIGHT CLEAR LENS ASSEMBLY WITH 12-254V AC/DC L AMP MODULE HKHPLBL PILOT LIGHT BLUE LENS ASSEMBLY WITH 12-254V AC/ DC LAMP MODULE
2 POSITION SELECTOR SWITCHES
HKH2PSMTH1 2 POSITION MAINTAINED CONTACT, HORIZONTAL WITH 1 N.O. & 1 N.C. CONTACT & HK HPMBRKT
HKH2PSMTV1 2 POSITION MAINTAINED CONTACT, VERTICAL WITH 1 N.O. & 1 N.C. CONTACT & HKHPMBRKT HKH2PSMMRH1 2 POSITION MOMENTARY RIGHT CONTACT, HORIZONTAL WITH 1 N.O. & 1 N.C. CONTACT & HKHPMBRKT HKH2PSMMRV1 2 POSITION MOMENTARY RIGHT CONTACT, VERTICAL WITH 1 N.O. & 1 N.C. CONTACT & HKHPMBRK T
HKH2PSKH1 2 POSITION KE YED, MAINT./MOM. RIGHT, HORIZONTAL WITH 1 N.O. & 1 N.C. CONTACT & HKHPMBRKT HKH2PSKV1 2 POSITION KE YED MAINT./MOM. RIGHT, VERTICAL WITH 1 N.O. & 1 N.C. CONTACT & HKHPMBRK T
3 POSITION SELECTOR SWITCHES
HKH3PSMTIH4 3 POS. MAINTAINED CONTACT INDEPENDENT CAM, HORIZONTAL WITH 2 N.O. CONTACTS & HKHPMBRK T
HKH3PSMTIV4 3 POS, MAINTAINED CON TACT INDEPENDENT CAM, VERTICAL WIT H 2 N.O. CONTACTS & HKHPMBRK T HKH3PSMMRH4 3 POS. MOM. RIGHT MAINT. LEFT/CNTR INDEPENDENT CAM, HORIZONTAL WITH 2 N.O. CONTACTS & HKHPMBRK T HKH3PSMMRV4 3 POS. MOM. RIGHT MAINT. LEFT/CNTR INDEPENDENT CAM, VERTICAL WITH 2 N.O. CONTACTS & HKHPMBRKT HKH3PSMMLH4 3 POS. MOM. LEFT, MAINT. RIGHT/CNTR INDEPENDEN T CAM, HORIZONTAL WITH 2 N.O. CONTACTS & HKHPMBRKT
HKH3PSMMLV4 3 POS. MOM. LEF T, MAINT. CNTR /RIGHT INDEPENDENT CAM, VERTICA L WITH 2 N.O. CONTACTS & HKHPMBRKT
HKH3PSMMLRH4 3 POS. MOM. LEF T/RIGHT, MAINT. CNTR INDEPENDENT CAM, HORIZONTAL WITH 2 N.O. CONTACTS & HKHPMBRKT
HKH3PSMMLRV4 3 POS. MOM. LEF T/RIGHT, MAINT. CNTR INDEPENDENT CAM, VERTICAL WITH 2 N.O. CONTACTS & HKHPMBRK T
HKH3PSKIH4 3 POSITION KE YED MAINT./MOM. INDEPENDENT CAM, HORIZONTAL WITH 2 N.O. CONTACTS & HKHPMBRKT HKH3PSKIV4 3 POSITION KE YED MAINT./MOM. INDEPENDENT CAM, VERTICAL WITH 2 N.O. CONTACTS & HK HPMBRKT
Page 30
KILLARK CONTROLS
O
O
C
C
HKH SERIES
H
H
ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS MADE TO YOUR SPECIFICATIONS
ATEX/IECEx Certified
Panel Mount
Actuator
Build your own custom actuator by completing part number for contact arrangement, legend, plate and accessory.
Bracket
Explosion Protected
Contact Block
Locknut
Spacer**
Silicone
Sealing Washer
** Required on thin wall Panel only < .16” thick. Refer to instruction sheet for actuator
0539 II 2 G Ex e IIC Gb 0539 II 2 D Ex tb IIIC Db
IP66
-50ºC ≤ Ta ≤ 60 ºC DEMKO 14 ATEX 1400U Ex e IIC Gb Ex tb IIIC Db
-50°C ≤ Ta ≤ +60°C IECE x UL 14.0 104U
cULus Certified
Class I, Zone 1, AEx e IIC Gb / Ex e IIC Gb U Zone 21, AEx tb IIIC Db / Ex tb IIIC Db U Class I, Division 2, Groups A, B, C, D Class II, Div. 1, Groups E, F, G (Canada) Class II, Division 2, Groups E, F, G Class III
-50°C ≤ Ta ≤ +60°C Type 3/4/4X/12/13 IP66
R
R
T
T
O
O
N
N
L
L
S
S
C
C
O
O
Z
Z
L
L
FEATURES-SPECIFICATIONS
To order complete with mounting bracket, contacts or pilot light module add suffix to end of catalog number for each;
CONTROL MODULE
L – LED LAMP 1 – 1 NO/1 NC 2 – 1 NO
* Available only with operator HKHPBMMTC
LEGEND PL ATE
A – START B – STOP C – ON D – OFF E – EMERGENCY STOP F – PUSH TO TEST G – RAISE H – LOWER J – OPEN K – CLOSE L – FORWARD M – REVERSE N – RESET P – UP
ACCESSORY
L1– LOCKOUT SST DEPRESSED LOCKOUT, PUSH
BUTTON, MOMENTARY
L2
– LOCKOUT, PLASTIC COVER, PUSH BUT TON,
MUSHROOM, SELECTOR
L3
– LOCKOUT, SST BAR LOCKOUT, PUSH BUTTON,
DEPRESSED MUSHROOM
L4
– LOCKOUT, SST HINGED, PUSH BUT TON,
DEPRESSED MUSHROOM
i.e. Momentary Push Button complete with Panel Mounting Bracket, control module for 1NO/1NC contact, “START” Legend Plate, and plastic Flip Cover Lockout: HK HP BMMSS1AL 2
For red Pilot Light complete with Panel Mounting Bracket, LED Module, and “OFF” Legend Plate: HKHPLRLD
3 – 1 NC 4 – 2 NO 5 – 2 NC
Q – DOWN R – ON-OFF S – OFF-ON T – UP-DOWN X – HAND-AUTO Y – OPEN-CLOSE Z – OFF-REMOTE 0 – BLANK 1 – SPECIF Y CUSTOM
MARKING
4
– RUN-OFF-JOG
5 – REV-OFF-FWD 7 – HAND-OFF-REM 9 – HAND-OFF-AUTO
*6 – 2NO/1NC *7 – 1NO/2NC *8 – 3 NO *9 – 3 NC
MOMENTARY START/STOP PUSH BUTTONS
BASIC CATALOG NUMBERS DESCRIPTION
HKHPBMMSS( )
HKHPBMMTC( ) MOMENTARY PUSH BUTTON, 3 CONTACTS
MOMEN TARY PB, W/ GREEN START, GREEN (I), RED STOP & RED (O),
GREEN, RED & BLACK BL ANK DISCS
MOMENTARY MUSHROOM HEAD PUSH BUTTONS
HKHPBMMMR( ) MOMENTARY MUSHROOM PB, RED HKHPBMMMB( ) MOMENTARY MUSHROOM PB, BLACK HKHPBMMMG( ) MOMENTARY MUSHROOM PB, GREEN
DOUBLE MOMENTARY PUSH BUTTON
HKHDBLPBMMGR( ) DOUBLE MOMENTARY PB, GREEN & RED BUT TONS
MAINTAINED MUSHROOM HEAD PUSH BUTTONS
HKHPBPMTMR( ) MAINTAINED MUSHROOM PUSH/PULL PB, RED HKHPBPMTMB( ) MAINTAINED MUSHROOM PUSH/PULL PB, BLACK HKHPBPMTMG( ) MAINTAINED MUSHROOM PUSH/PULL PB, GREEN
HKHPBTMTMR( ) MAINTAINED MUSHROOM PB TWIST RELEASE, RED HKHPBKMTMRH( ) MAINTAINED PUSH BUTTON KEY RELEASE, MUSHROOM RED HD, HORIZONTAL HKHPBKMTMRV( ) MAINTAINED PUSH BUT TON KEY RELEASE, MUSHROOM RED HD, VERTICAL
PILOT LIGHT LENS ASSEMBLY
HKHPLR( ) PILOT LIGHT RED LENS ASSEMBLY HKHPLG( ) PILOT LIGHT GREEN LENS ASSEMBLY HKHPLA( ) PILOT LIGHT AMBER LENS ASSEMBLY HKHPLC( ) PILOT LIGHT CLEAR LENS ASSEMBLY HKHPLB( ) PILOT LIGHT BLUE LENS ASSEMBLY
2 POSITION SELECTOR SWITCHES
HKH2PSMTH( ) 2 POSITION MAINTAINED CONTACT, HORIZONTAL
HKH2PSMTV( ) 2 POSITION MAINTAINED CONTACT, VERTICAL HKH2PSMMRH( ) 2 POSITION MOMENTARY RIGHT CONTACT, HORIZONTAL HKH2PSMMRV( ) 2 POSITION MOMENTARY RIGHT CONTACT, VERTICAL
HKH2PSKH( ) 2 POSITION KEYED, MAINT./MOM. RIGHT, HORIZONTAL
HKH2PSKV( ) 2 POSITION KEYED MAINT./MOM. RIGHT, VERTICAL
3 POSITION SELECTOR SWITCHES
HKH3PSMTIH( ) 3 POS. MAINTAINED CONTACT INDEPENDENT CAM, HORIZONTAL
HKH3PSMTIV( ) 3 POS, MAINTAINED CONTACT INDEPENDENT CA M, VERTICAL HKH3PSMMRH( ) 3 POS. MOM. RIGHT MAINT. LEFT/CNTR INDEPENDENT CAM, HORIZONTAL HKH3PSMMRV( ) 3 POS. MOM. RIGHT MAINT. LEFT/CNTR INDEPENDENT CAM, V ERTICAL
HKH3PSMMLH( ) 3 POS. MOM. LEFT, MAINT. RIGHT/CNTR INDEPENDENT CAM, HORIZONTAL
HKH3PSMMLV( ) 3 POS. MOM. LEF T, MAINT. CNTR/RIGHT INDEPENDENT CAM, VERTICAL HKH3PSMMLRH( ) 3 POS. MOM. LEF T/RIGHT, MAINT. CNTR INDEPENDENT CAM, HORIZONTAL HKH3PSMMLRV( ) 3 POS. MOM. LEFT/RIGHT, MAINT. CNTR INDEPENDENT CAM, VERTICAL
HKH3PSKIH( ) 3 POSITION K EYED MAINT./MOM. INDEPENDENT CAM, HORIZONTAL HKH3PSKIV( ) 3 POSITION KEYED MAINT./MOM. INDEPENDENT CAM, VERTICAL
Page 31
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
ACTUATOR PROPERTIES AND PANEL MOUNT INSTALLATION
HKHPBMMSS
Momentary Push Button will depress two Contact Blocks. Supplied with 7 colored inserts shown.
HKHPBMMTC
Momentary Push Button will depress three Contact Blocks. Supplied with 7 colored inser ts.
* For Din Rail Mounting Only.
ATEX/IECEx Certified
0539 II 2 G Ex e IIC Gb 0539 II 2 D Ex tb IIIC Db
IP66
-50ºC ≤ Ta ≤ 60 ºC DEMKO 14 ATEX 1400U Ex e IIC Gb Ex tb IIIC Db
-50°C ≤ Ta ≤ +60°C IECE x UL 14.0 104U
HKHPBMMMR, HKHPBMMMG, HKHPBMMMB
Momentary Mushroom Push Button will depress two Contact Blocks. Available in Red, Green and Black
HKHPBPMTMR, HKHPBPMTMG, HKHPBPMTMB
Maintained Mushroom Push Button with Pull Release will depress two Contact Blocks. Available in Red, Green and Black.
cULus Certified
Class I, Zone 1, AEx e IIC Gb / Ex e IIC Gb U Zone 21, AEx tb IIIC Db / Ex tb IIIC Db U Class I, Division 2, Groups A, B, C, D Class II, Div. 1, Groups E, F, G (Canada) Class II, Division 2, Groups E, F, G Class III, Division 1 (Canada) Class III
-50°C ≤ Ta ≤ +60°C Type 3/4/4X/12/13 IP66
HKH2PSMTH, HKH2PSMTV, HKH2PSMMRH, HKH2PSMMRV
2 Position Rotary Selector Switches for Maintained & Momentary action will depress two Contact Blocks.
HKH3PSMTIH, HKH3PSMTIV, HKH3PSMMRH, HKH3PSMMRV, HKH3PSMMLH, HKH3PSMMLV, HKH3PSMMLRH, HKH3PSMMLRV
3 Position Rotary Selector Switches for Maintained & Momentary action with Independent Cams that will depress one Contact Block in each Left & Right Positions.
HKHPBILLMM
Momentary Illuminated Push Button with LED Lamp that will depress two Contact Blocks. Available with Red, Green, Amber, Clear and Blue transparent inserts.
* For Din Rail Mounting Only.
HKHPLR, HKHPLG, HKHPLA, HKHPLC, HKHPLB
Pilot Light Lens Assembly. Available in Red, Green, Amber, Clear and Blue
HKHPBKMTMRH, HKHPBKMTMRV
Maintained Mushroom Push Button with Key Release will depress two Contact Blocks. Available in Red only.
HKHPBTMTMR
Maintained Mushroom Push Button with Twist Release will depress two Contact Blocks. Available in Red only
HKH2PSKH, HKH2PSKV
2 Position Key Rotary Selector Switches for Maintained & Momentary action will depress two Contact Blocks.
HKH3PSKIH, HKH3PSKIV
3 Position Key Rotary Selector Switches for Maintained & Momentary action with Independent Cams that will depress one Contact Block in each Left & Right Positions.
HKHDBLPBMMGR
Double Momentary Push Button will depress one Contact Block on each button. Supplied with 7 colored inserts shown by HKHPBMMSS.
Page 32
KILLARK CONTROLS
HKH SERIES
DIMENSIONAL DATA FOR INSTALLATION OF HKH PANEL MOUNTED ACTUATORS
FEATURES-SPECIFICATIONS
For installation on
Type 1, 3, 3R, 4/4X,
12 & 13 and IP66
Enclosures
Mounting:
Intended for use in 30.5mm device openings in control station covers with panel thickness of
0.04”-0.25”.
Actuators are intended for use in conjunction
Orientation of rotary actuator part
Figure 1
numbers ending in “V”
Keyway positioned at 12 o’clock
Figure 2
Orientation of rotary actuator
part numbers ending in “H”
Keyway positioned at 3 o’clock
with Killark HKH Series Contact Blocks.
For US / CAN Applications:
Actuators and Pilot Light Lens Assembly shall be installed in a Class I, Zone 1, AEx e IIC / Ex e IIC increased safety enclosure with a minimum IP54 rating or a Class I, Zone 1, AEx d IIC / Zone 21, AEx tb IIIC / Ex d IIC / Ex tb IIIC flameproof / dust ignition-proof enclosure with a minimum IP64 rating, where the suitability is determined in the end application.
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
C
C
O
O
Z
Z
L
L
Minimum spacing for rotary actuator
part numbers ending in “V”
Note: Some Actuators are supplied with an “H” or a “V” at the end of the catalog
number. These letters apply to the orientation of the din rail when used in applications with din rails. This feature allows for two dif ferent spacings when installed as panel mount. See details for “H” & “V” actuator spacing and contact block orientation.
When installing other actuators such as push buttons & pilot lights the keyway must
also be positioned in the same location as the rotary actuators. See Fig. 1 and Fig. 2
Minimum spacing for rotary actuator
part numbers ending in “H”
LEGEND PLATE APPLICATION
For ATEX / IECEx Applications:
Actuators and Lens Covers shall be installed in a Group I and/or Group II, ‘Ex e’ increased safety enclosure with a minimum IP54 rating or an ‘Ex d / tb’ flameproof / dust ignition­proof enclosure with a minimum IP64 rating, where the suitability is determined in the end application.
30.5mm Device Hole Detail
Important to maintain Ingress Protection
ACTUATOR LEGEND PLATES:
HKH actuators will only accept Killark Legend Plates. To insure ingress protection and proper operation is maintained the four flat sides of the plate must match up to the four flat areas on the bottom side of the actuator housing. This must be done to allow the legend plate to float freely under the actuator housing.
Legend Plate Actuator Housing
Page 33
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
ACTUATOR ACCESSORIES / EARTH CONTINUITY PLATES / NUT TOOL
L1
HKHPBMMDHLO
L2
FEATURES-SPECIFICATIONS
Applications
L1 - Hinged Stainless Steel Lockout for standard momentary push button in depressed position
L2 - Plastic Flip Cover Lockout used for momentary push button actuators, selector switch actuators, and mushroom push button actuators
L3 - Bar on Chain Stainless Steel Lockout used for mushroom push buttons in depressed position
L4 - Hinged Stainless Steel Lockout for mushroom push button in depressed position
HKHPBSSMFCLO
CATALOG NUMBER DESCRIPTION
HKHPBSSMFCLO MOM. PB, SELECTOR SWITCH, MUSHROOM PB, PLASTIC FLIP COVER LOCKOUT
HKHPBMMDHLO PB DEPRESSED STD. MOMENTARY HINGED STAINLESS STEEL LOCKOUT
HKHPBMHLO PB DEPRESSED MUSHROOM HINGED STAINLESS STEEL LOCKOUT HKHPBMBLO MUSHROOM BAR ON CHAIN STAINLESS STEEL LOCKOUT
CATALOG NUMBER DESCRIPTION
HKHGP12M20 GROUND PLATE, BRASS SZ 1 ENCL. 2-M20 HKH GP11M20 GROUND PL ATE, BRASS SZ 1 ENCL. 1-M20 HKH GP11M25 GROUND PL ATE, BRASS SZ 1 ENCL. 1-M25 HKH GP11M32 GROUND PL ATE, BRASS SZ 1 ENCL. 1-M32 HKHGP22M25 GROUND PLATE, BRASS SZ 2 ENCL. 2-M25 HKHGP22M20 GROUND PLATE, BRASS SZ 2 ENCL. 2-M20 HKHGP21M32 GROUND PLATE, BRASS SZ 2 ENCL. 1-M32
HKHANTOOL ACTUATOR NUT TOOL
HKHPMBRKT CONTACT BLOCK & PILOT LIGHT PANEL MOUNT BRACKET
HKHCP COVER DEVICE PLUG
L3
HKHPBMBLO
L4
HKHPBMHLO
ACCESSORIES
BRASS EARTH CONTINUITY PLATE (ECP)
ACTUATOR NUT TOOL
CONTACT BLOCK & PILOT LIGHT PANEL MOUNT BRACKET
COVER PLUG
HKHGP11M20
HKHGP22M20
HKHANTOOL
HKHPMBRKT
One panel mount bracket required with each actuator for panel mount applications. Additionally use contact blocks and pilot light modules ending in “P”.
HKHCP
Page 34
FACTORY SEALED CONTACT BLOCK MODULES
ATEX/IECEx Certified
0539 I M 2 E x de I Mb 0539 II 2 G Ex de IIC Gb
Ambient Range: -55ºC < Ta < 60ºC DEMKO 12 ATEX 1202251U Ex de I Mb Ex de IIC Gb IECE x UL 12.0033U
cULus Certified
Class I, Zone 1, AEx de IIC T4 / Ex de IIC T4 X Class I, Division 2, Groups A, B, C, D Ambient Range: -55ºC < Ta < 60ºC
HKH1NO20PHKH1NC20 D
KILLARK CONTROLS
HKH SERIES
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
C
C
O
O
Z
Z
L
L
Normally Closed Contact Identification:
All Gray marked: N.C. / (11&12)
HKH1NC20 D
HKH1NC20 P
FEATURES-SPECIFICATIONS
Applications
Standard controls station assembles are supplied with electrical devices mounted to a din rail inside the box portion of the control station, identified with a “D” in the catalog number. i.e. HKH1AND2P11K8, containing contact blocks ending in “D”. When panel or cover mounted version is desired one HKHPMBRKT bracket is required for each actuator to assemble contacts, no DIN Rail supplied. Bracket will mount one contact block in the center or two side by side. Contact block part numbers ending in “P” supplied. Complete control station catalog number to be HKH1ANP2P11K8 .
SS Terminal Screw Head for use with the following screwdriver types:
Slotted
Phillips
Robertson
Wire Range for 1 or 2 conductors as listed:
0.5 to 2.5mm2
(SOL & STR)
4.0mm2 (STR)
#22 to #12 AWG
(SOL & STR)
#10 AWG (STR)
CONTACT BLOCK
CATALOG NUMBERS DESCRIPTION
HKH 1NO20D N.O. CONTACT, 20A DIN RAIL MOUNT HKH 1NC20D N.C. CONTACT, 20A DIN RAIL MOUNT HKH1NO20P N.O. CONTACT, 20A PANEL MOUNT
HKH 1NC20P N.C. CONTACT, 20A PANEL MOUNT
White center body with gray terminal covers mar ked: N.O./ (13&14)
HKH1NO20D HK H1NO20P
Normally Open Contact Identification:
Contact Block Applications for US/CAN:
Contact block shall be installed in a Class I, Zone 1, AEx e II/Ex e IIC increased safety enclosure with a minimum IP54 rating or a Class I, Zone 1, AEx d IIC/Zone 21, Aex tb minimum IP64 rating, where the suitability is determined in the end application.
Contact Block Applications for ATEX/IECEx:
Contact block shall be installed in a Group I and/or Group II, ‘Ex e’ increased safety enclosure with a minimum IPS4 rating or an ‘Ex d/ tb’ flameproof/dust enclosure with a minimum IP64 rating, where the suitability is determined in the end application.
Contact Block Features:
UL Electrical Rating: 690Vac, 20A, 50-60Hz, 60Vdc, 5A, 110Vdc,
2A, 255Vdc, 1.5A, 1/2 HP @120Vac, 1 HP@208/240/277Vac, A600/P600- Pilot Duty 350Vac- Tungsten Lamp.
Wire Allowances: WIRE RANGE with 1 or 2 WIRES: #22 to #12
AWG (SOL & STR) and #10 AWG (STR).
IEC Electrical Ratings: AC690V 16A AC-12, 50-60 Hz, AC230V
16A AC-15, 50-60Hz, DC60V 5A DC-12, DC125 1A DC-12.
Wire Allowances: WIRE RANGE with 1 or 2 WIRES: 0.5 to 2.5mm
(SOL & STR) and 4.0mm
2
(STR)
Silver Alloy contacts with Gold Flashing.
Page 35
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
FACTORY SEALED PILOT LIGHT MODULES
ATEX/IECEx Certified
0539 I M 2 E x de I Mb 0539 II 2 G Ex de IIC Gb
Ambient Range: -50ºC < Ta < 60ºC DEMKO 14 ATEX 1337U Ex de I Mb Ex de IIC Gb IECE x UL 14.0 047U
cULus Certified
Class I, Zone 1, AEx de IIC T5 / E x de IIC T5 X Class I, Division 2, Groups A, B, C, D Ambient Range: -50ºC < Ta < 60ºC
HKHPLD HKHPLP
FEATURES-SPECIFICATIONS
Applications
Standard control station assemblies are supplied with electrical devices mounted to a din rail inside the box portion of the control station, identified with a “D” in the catalog number. i.e. HKH1AND2LRL0K8. Containing pilot light part number ending in “D”. When panel or cover mounted version is desired one HKHPMBRKT bracket is required for each actuator to assemble pilot light, no DIN Rail supplied. The pilot light module will mount on the center of the bracket. Catalog number will change to HKH1ANP2LRL0K8. Pilot light module part number ending in “P”.
AMMETERS, 1A, 72MM
MEASURING
TYPE
DIRECT
MEASURING
FOR CURRENT
TRANSFORMER
OVERLOAD
SCALE
Pilot Light Applications for US/CAN:
Pilot Light shall be installed in a Class I, Zone 1, AEx e IIC/Ex e IIC increased safety enclosure with a minimum IP54 rating or a Class I, Zone I, AEx d IIC/Zone 21, AEx tb IIIC/Ex d IIC/ Ex tb IIIC flameproof/dust enclosure with a minimum IP64 rating, where the suitability is determined in the end application. Electrical Rating: 12-250Vac/Vdc, 50-60 Hz, 0.6 WATTS.
Pilot Light Applications for ATEX/IECEx:
Pilot Light shall be installed in a Group I and/or Group II, ‘Ex e’ increased safety enclosure with a minimum IP54 rating or an ‘Ex d/tb’ flameproof/dust enclosure with a minimum IP64 rating, where the suitability is determined in the end application. Electrical Rating: 12-254 Vac/Vdc, 50-60 Hz, 0.6 WATTS.
Wire Allowances:
WIRE RANGE with 1 or 2 WIRES: #22 to #12 AWG (SOL & STR) and #10 AWG (STR) 0.5 to
2.5mm (SOL & STR) and 4.0mm2 (STR)
PILOT
CATALOG NUMBERS DESCRIPTION
HKHPLD PILOT LIGHT MODULE DIN R AIL MOUNT HKHPLP PILOT LIGHT MODULE PANEL MOUN T
VOLTMETERS, 72MM
ATEX/IECEx Certified
Ex e II IECE x CQM 08.0007U
II 2G Ex e II
DNV-2008-OSL
-ATE X-21659U
-40°C < Ta < 60°C
2
5
MEASURING
RANGE
0-1 / 2A
0-4 / 8A
0-5 / 10A 0-10 / 20A 0-15 / 30A
0-1 / 5A
0-2.5 / 12.5A
0-5 / 25A 0-15 / 75A
0-25 / 125A 0-40 / 200A 0-50 / 250A 0-60 / 300A 0-75 / 375A
0-100 / 500A
0-150 / 750A 0-200 / 1000A 0-250 / 1250A 0-30 0 / 1500A 0-400 / 2000A 0-500 / 2500A 0-600 / 3000A
RANGE
(AC)
0-25V
0-40V 0-150 V 0-250V
0-500V
Page 36
HUBS / CABLE GLANDS
KILLARK CONTROLS
HKH SERIES
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
C
C
O
O
Z
Z
L
L
FEATURES-SPECIFICATIONS
Applications
The 421 cable gland provides a seal on the outer cable sheath and is intended for use on non-armoured elastomer and plastic insulated cables. The cable gland is dual certified Exd and Exe and is suitable for installation in Zone 1 (21) and Zone 2 (22) hazardous areas.
The MC cable gland is designed for use with jacketed interlocked, continuously corrugated and welded armor cable. Install where it is essential to provide positive grounding to the cable and for a Type 3, 4 connection.
HUBS/GLANDS
CATALOG LOGIC NUMBER DESCRIPTION
H1 421S SINGLE COMP. BRASS GLA ND OS-M20 H2 421 SINGLE COMP. BRASS GLAND O-M20 H3 421N SINGLE COMP. BRASS GLAND A-M20 H4 421N SINGLE COMP. BRASS GL AND B-M25 H5 421N SINGLE COMP. BRASS GLA ND OS-M20 NAL NICKEL PL ATE H6 421N SINGLE COMP. BRASS GL AND O-M20 NAL NICKEL PLATE H7 421N SINGLE COMP. BRASS GLAND A-M20 NAL NICKEL PLATE H8 421N SINGLE COMP. BRASS GLAND B-M25 NAL NICKEL PLATE H9 421N SINGLE COMP. BRASS GLAND C-M32 HA 421N SINGLE COMP. SS GLAND OS-M20 HB 421N SINGLE COMP. SS GLAND O-M20 HC 421N SINGLE COMP. SS GLAND A-M20 HD 421N SINGLE COMP. SS GLAND B-M25 HE 421N SINGLE COMP. BRASS GLAND C-M32 NAL NICKEL PLATE HF 421N SINGLE COMP. SS GLAND C-M32 J1 453R SINGLE COMP. BRASS GLAND OS-M20 J2 453R SINGLE COMP. BRASS GL AND O-M20 J3 453R SINGLE COMP. BRASS GLAND A-M20 J4 4 53R SINGLE COMP. BRASS GLAND B-M25 J5 453R SINGLE COMP. BRASS GLAND OS-M20 NAL NICKEL PLATE J6 453R SINGLE COMP. BRASS GLAND O-M20 NAL NICKEL PLATE J7 453R SINGLE COMP. BRASS GLA ND A-M20 NAL NICKEL PLATE J8 453R SINGLE COMP. BRASS GLA ND B-M25 NA L NICKEL PLATE J9 453R SINGLE COMP. BRASS GLAND C-M32 JA 453R SINGLE COMP. SS GLAND OS-M20 JB 453R SINGLE COMP. SS GLA ND O-M20 JC 453R SINGLE COMP. SS GLAND A-M20 JD 453R SINGLE COMP. SS GLAND B-M25 JE 453R SINGLE COMP. BRASS GLA ND C-M32 NAL NICKEL PLATE JF 453R SINGLE COMP. SS GLAND C-M32 K1 MCIC JACKET ED METAL CLAD CONNECTOR K2 MC2 JACKETED ME TAL CLAD CONNECTOR K3 MC3 JACKETED METAL CL AD CONNEC TOR K4 WH-1G ZINC 1/2” HUB K5 WH-2G ZINC 3/4” HUB K6 WH-3G ZINC 1” HUB K7 WH-SS1G STAINLESS STEEL 1/2” HUB K8 WH-2SSG STAINLESS STEEL 3/4” HUB K9 WH-3SSG STAINLESS STEEL 1” HUB KA WH-1A ALUM. 1/2” KB WH-2A ALUM. 3/4” KC WH-3A ALUM. 1” HUB KD NMHG1EX P VC COATED 1/2” HUB KE NMHG2EX PVC COATED 3/4” HUB KF NMHG3EX PVC COATED 1” HUB
Page 37
KILLARK CONTROLS
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
Z
Z
HKH SERIES
C
C
O
O
L
L
CATALOG LOGIC
HKH 1B N D 2 P1 1 A L1
BOX SIZE 1A – ONE DEVICE 1B – ONE DEVICE / T WO DEVICE 1C – TWO DEVICE / 3 DEVICE
MATERIAL N – GRP POLYAMIDE S – 316 STAINLESS STEEL FLANGE IN E – 316 STAINLESS STEEL FLANGE OUT
CONTACT/PILOT LIGHT MOUNTING METHOD
D – DIN RAIL MOUNT P – PANEL MOUNT
ENTRY FOR CABLE 1 – 1/2”NPT HOLE BOTTOM 2 – 3/4”NPT HOLE BOTTOM *3 – 1”NPT HOLE BOTTOM 4 – 1/2” NPT HOLE FEED
THRU
5 – 3/4” NPT HOLE FEED
THRU
*6 – 1” NPT HOLE FEED
THRU
7 – 1/2”NPT HOLE TOP 8 – 3/4” NPT HOLE TOP *9 – 1” NPT HOLE TOP A – M20 GLAND HOLE
BOTTOM
D – 2EA M20 GLAND HOLE
BOTTOM
G – M25 GLAND HOLE
BOTTOM
K – 2EA M25 GL AND HOLE
BOTTOM
N – M32 GLAND HOLE
BOTTOM
**R – 1EA M20 TAPPED HOLE
BOTTOM
**S – 1EA M25 TAPPED HOLE
BOTTOM
**T – 2EA M20 TAPPED HOLE
BOTTOM
**U – 2EA M25 TAPPED HOLE
BOTTOM
**V – 1EA M32 TAPPED HOLE
BOTTOM
BRASS ECP PLATE FOR METRIC ONLY
E – WITH BRASS EARTH CONTINUITY PLATE METRIC ONLY
OPERATOR
S5 –
P1 – PUSHBUTTON, MOMENTARY,
GS,RS,RO,GI,G,R,B
P2 – DOUBLE PUSHBUTTON,
MOMENTARY, GS,RS,G0,G1,G,R,B
M1 – PUSHBUTTON, MUSHROOM
MOMENTARY, RED
M2 – PUSHBUTTON, MUSHROOM
MOMENTARY, GRN
M3 – PUSHBUTTON, MUSHROOM
MOMENTARY, BLK
M4 – PUSHBUTTON, MUSHROOM PULL
RELEASE MAINTAINED, RED
M5 – PUSHBUTTON, MUSHROOM PULL
RELEASE MAINTAINED, GRN
M6 – PUSHBUTTON, MUSHROOM PULL
RELEASE MAINTAINED, BLK
M7 – PUSHBUTTON, MUSHROOM
TWIST RELEASE MAINT, RED
M8 – PUSHBUTTON, MUSHROOM KEY
MAINT, RED, KEY RELEASE
S1 – SELECTOR SWITCH, 2 POS. MAINT.
SELECTOR SWITCH, 2 POS. MOM. RIGHT
S2 –
S3 – SELECTOR SWITCH, 3 POS. MAINT.
S4 – SELECTOR SWITCH, 3 POS. MOM.
LEFT & RIGHT
SELECTOR SWITCH, 3 POS. MOM. RIGHT
S6
SELECTOR SWITCH, 3 POS. MOM. LEFT
K1
KEY SELECTOR SWITCH, 2 POS. MAINT.
K2 – KEY SELECTOR SWITCH, 2 POS.
MOM. RIGHT
K3
KEY SELECTOR SWITCH, 3 POS. MAINT.
K4 – KEY SELECTOR SWITCH, 3 POS.
MOM. LEFT & RIGHT
K5 – KEY SELECTOR SWITCH, 3 POS.
MOM. RIGHT
K6 – KEY SELECTOR SWITCH, 3 POS.
MOM. LEFT
LR – RED LENS ASSY LG – GREEN LENS ASSY LA – AMBER LENS ASSY LC – CLEAR LENS ASSY LB – BLUE LENS ASSY CP – COVER BLANKING PLUG BR – ILLUMINATED PUSH BUTTON, RED BG –
ILLUMINATED PUSH BUTTON, GREEN
BA
ILLUMINATED PUSH BUTTON, AMBER
BC
ILLUMINATED PUSH BUTTON, CLEAR
BB
ILLUMINATED PUSH BUTTON, BLUE
TC – MOMENTARY P.B. 3 CONTACTS
INTRNAL EXTERNAL EARTHING STUD
S – INTERNAL
EXTERNAL EARTH STUD ­ONE WITH EACH ECP
HUB/GLAND
SEE PAGE C37
ACCESSORY L1 – LOCKOUT, SST DEPRESSED
LOCKOUT, PUSHBUTTON, MOMENTARY
L2 – LOCKOUT, PLASTIC COVER,
PUSHBUTTON, MUSHROOM, SELECTOR
L3 – LOCKOUT, SST BAR LOCKOUT,
PUSHBUTTON, DEPRESSED MUSHROOM
L4 – LOCKOUT, SST HINGED,
PUSHBUTTON, DEPRESSED MUSHROOM
LEGEND PL ATE A – STA RT B – STOP C – POWER ON D – POWER OFF E – EMERGENCY STOP F – PUSH TO TEST G – RAISE H – LOWER J – OPEN K – CLOSE L – FORWARD M – REVERSE N – RESET P – UP
Q – DOWN R – ON-OFF S – OFF-ON T – UP-DOWN X – HAND-AUTO Y – OPEN-CLOSE 0 – BLANK 1 – SPECIFY CUSTOM
MARKING
2 – RAISE-OFF-LOWER 3 – JOG-OFF-RUN 4 – RUN-OFF-JOG 5 – FWD-OFF-REV 9 – HAND-OFF-AUTO
CONTROL MODULE L – LED LAMP 1 – 1 NO/1 NC 2 – 1 NO 3 – 1 NC 4 – 2NO 5 – 2NC *** 6 – 2NO/ 1NC *** 7 – 1NO/2NC *** 8 – 3NO *** 9 – 3NC
* Available in Enclosure Material type “S” and “E” only ** Available in Enclosure Material type “N” only *** Available only with operator “TC”.
Note: Additional options available not shown.
Consult factory for modifications not listed.
Loading...