LINEAR FLUORESCENT EMERGENCY LIGHTING
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 7(C,D) 9(E,F,G)
4’ Nominal Style
2’ Nominal Style
Suitable for wet locations
- File E12976 and E8 9665 (Marine)
3 UL 924, UL 8 44
Certified - File LR11713
KILLARK LIGHTING
HFXE SERIES
T
T
I
I
H
H
N
N
G
G
G
G
I
I
L
L
H
H
C
C
A
A
O
O
Z
Z
L
L
FEATURES-SPECIFICATIONS
Applications
HFXE Series Emergency Lighting fixtures
provide continuous illumination under
normal power and switch to emergency
battery backup during power outages. Units
contain a battery unit that provides the
OSHA required 90 minutes of illumination for
egress.
Units are designed for installations where
moisture, dirt, dust, corrosion and vibration
may be present, or wet locations where
wind, water and snow can be expected.
They can also be used in locations made
hazardous due to the presence of flammable
or explosive gases, vapors and combustible
ducts as defined by the NEC.
Features
• Construction is strong lightweight
corrosion resistant copper-free aluminum
alloy, less than 4/10 of 1%
• All external hardware is corrosion
resistant 316 stainless steel to provide
maintenance free long life
• World voltage ballasts standard on 32W
and BIAXIAL models (120-277V 50/60 Hz)
• LED charging indicator light on ballast
enclosure.
See page L172 for Dimensions and
Accessories
HFXE FLUORESCENT EMERGENCY LIGHTING
CATALOG
NUMBERjk
HFXE2-265-302
HFXE2-430-12 120V 60 Hz 40W T12 electronic ballast 430M A
HFXE2-430-42 277V 60 Hz 40W T12 electronic ballast 430MA
HFXE2-460-302 120V-277 V 50/60 Hz
HFXE1-800-12 120V 60 Hz 60W T12 electronic ballast 800MA
HFXE1-800-42 277V 60 Hz 60W T12 electronic ballast 800MA
HFXE2-265-303
HFXE2-430-13 120V 60 Hz 40W T12 electronic ballast 430MA
HFXE2-430-43 277V 60 Hz 40W T12 elec tronic ballast 430MA
HFXEZ-460-303 120V-277V 50/60 Hz
HFXE1-800-13 120V 60 Hz 60W T12 electronic ballast 800MA
HFXE2-265-304
HFXE2-430-14 120V 60 Hz 40W T12 electronic ballast 430MA
HFXE2-430-44 277V 60 Hz 40W T12 elec tronic ballast 430MA
HFXE1-800-14 120V 60 Hz 60W T12 electronic ballast 800MA
HFXE1-800-44 277V 60 Hz 60W T12 electronic ballast 800MA
HFXE1-40T-302
HFXE1-55T-302 2’ 2 Lamp 55W BIAXIAL
HFXE1-40T-304 4’ 4 Lamp 40W BIAXIAL
HFXE1-55T-304 4’ 4 Lamp 55W BIAXIAL
j Digit after “E” in catalog logic indicates number of lamps energized in emergency mode.
k Consult non- emergency HFX pages L164-169 for thermal, dimensional and other data, plus for available
accessories. 40W & 60W are not available with universal voltage or 240V 50Hz ballasts.
l 1,2 and 3 tube models are third party certi ed. 4 tube models are self-certied.
NOTES: For fusing, add suffix F1 for 120V; F4 for 277V.
Emergency unit will start lamps at 0°F
32W T8 electronic ballast minimum start is 0 °F
40W ballast is electronic with 50°F start
60W ballast start at -20 °F
32W & 40W units operate 2 lamps in emergency mode for a maximum illumination
60W and BIAXIAL units operate a single lamp. 3 lamp 277V 60W emergency units not available.
Replacement Battery Pack #KFBP10
EMERGENCY LUMEN CHART
LAMPS INITIAL LUMENS
2 32W lamps 1350 900
2 40W lamps 110 0 640
1 60W lamp 1200 810
1 40W BIAXIAL 900 540
1 55W BIAXIAL 900 465
CONDUIT
SIZE
3/4”
3/4”
3/4”
l
3/4” 120-277 V 50/60 HZ
LINE VOLTA GE DESCRIPTION PROFILE
120-277 V 50/60 Hz 32W T8 electronic ballast 265MA
120-277 V 50/60 Hz 32W T8 electronic ballast 265MA
120-277 V 50/60 Hz 32W T8 electronic ballast 265MA
AFTER 90
MINUTES
54W T5HO Electronic Ballast 460MA
54W T5HO Electronic Ballast 460MA
BIAXIAL SERIES
2’ 2 Lamp 40W BIAXIAL
Two Glass Tubes
4’ Nominal
Three Glass Tubes
4’ Nominal
Four Glass Tubes
4’ Nominal
Two Glass Tubes