Page 1

ALUMINUM AND IRON OUTLET BODIES
GEC
E Ty pe
FEATURES-SPECIFICATIONS
Applications
GE series conduit boxes are installed in
conduit systems within hazardous areas to:
• Protect conductors in threaded rigid
conduit
• Act as pull and splice boxes
• Interconnect lengths of conduit
• Change conduit direction
• Provide access to conductors for
maintenance and future system changes
Features
GE conduit outlet boxes have:
• GEM, GEC and GES have water shedding
cover – suitable for wet locations when
mounted in upright position
• External cover threads on body protecting
conductors from damage during pulling
• No pinching of conductors during cover
installation
• Ten different hub arrangements
• Taper threaded hubs to provide ground
continuity
• Smooth integral hub bushing to protect
conductor insulation when pulling
• Internally threaded cover openings for
additional wiring room
• Covers furnished with boxes
• Weather-resistant finish
• Green ground screw standard in all boxes
KILLARK FITTINGS
GE SERIES
• 1/2”, 3/4” and 1” Bodiesj
Class I, Div. 1 & 2, Groups C & D
Class I, Zone 1, Groups IIB, IIA
• 1-1/4”, 1-1/2”, and 2” Bodies
Class I,Div. 1 & 2, Group D
Class I, Zone 1, Group IIA
• Class II, Div. 1 & 2, Groups E, F, G
• Class III
• For GEJ Series CSA applications for Class I
Group C, seal conduit within 18 inches
File No. E 10514
GEJ
E Ty pe
Material/Finish
Aluminum
•
BODY
Copper-free aluminum
(less than 4/10 of 1%)
•
FINISH
Electrostatically applied powder
coating
•
COVER
(Aluminum)
Copper-free aluminum (less than 4/10
of 1%). Electrostatically applied powder
coating
Iron
•
BODY
Duraloy iron alloy
•
FINISH
Tri-coat finish of electrozinc,
chromate sealant, and electrostatically
applied powder coating
E TYPE OUTLET BODY*
CATALOG NUMBER
KILLARK
GECET-1 GECET-1M 1/2”
GECET-2 GECET-2M 3 /4”
GECET-3 GECET-3M 1”
GEJE T-5 GEJET-5M
* For GROUP B applications, contact factory.
DURALOY
ALUM.
— — 1-1/4” — — — — — — — —
IRON
HUB
SIZE
1-1/ 2”
A B C D E F
3-11/16”
3-11/16”
3-11/16”
(94)
(94)
(94)
6-1 /4”
(159)
3-5/8”
(92)
3-5/8”
(92)
3-5/8”
(92)
4-3/8”
(111)
DIMENSIONS
2-11/16”
(68)
2-11/16”
(68)
2-11/16”
(68)
4-7/ 8”
(124)
Dimensions
Certified File No. LR11716
•
COVER
(Aluminum)
Copper-free aluminum (less than 4/10
of 1%). Electrostatically applied powder
coating
Size Ranges
• Hub – 1/2” to 2”
• Cover opening – 2-1/16” to
4-7/8” diameter
Applicable Third Party Standards
UL Standards: 886 and 1203
CSA Standard: C22.2 No. 30
Fed Spec: W-C-586D
Mil Spec: F-28675
COVER
OPENINGS
2-3/4”
(70)1”(25)
2-3/4”
(70)1”(25)
2-3/4”
(70)1”(25)
3-9/16”
(90)
1-3/16”
(46)
13/16”
(21)
13/16”
(21)
1-1/ 8”
(21)
1-3/16”
(46)
2-11/16”
(68)
2-11/16”
(68)
2-11/16”
(68)
4-7/ 8”
(124)
For ATEX and IEC Ex certified
GE Outlet Bodies, contact factory
F
F
H
H
VOLUME
CU. IN.
18
18
19
75
N
I
N
I
T
T
G
G
T
T
I
S
I
S
C
C
A
A
O
O
Z
Z
L
L
j 1/2”, 3/4” and 1” GEC Bodies L isted and Certi ed for:
Class I, Div. 1 & 2, Groups B, C, D
Class I, Zones 1 & 2, Groups IIB + H2
Class II, Div. 1 & 2, Groups E, F, G
Class III
Type 4X (NEMA)
GEC Type
E Type
Page 2

KILLARK FITTINGS
N
I
N
I
T
T
G
G
T
T
I
S
I
S
F
F
H
H
A
A
Z
Z
C
C
O
O
L
L
GE SERIES
ALUMINUM AND IRON OUTLET BODIES
• 1/2”, 3/4” and 1” Bodiesj
Class I, Div. 1 & 2, Groups C & D
Class I, Zone 1, Groups IIB, IIA
• 1-1/4”, 1-1/2”, and 2” Bodies
Class I,Div. 1 & 2, Group D
Class I, Zone 1, Group IIA
• Class II, Div. 1 & 2, Groups E, F, G
• Class III
• For GEJ Series CSA applications for Class I
Group C, seal conduit within 18 inches
File No. E 10514
GES
C Ty pe
GEM
L Ty pe
Certified File No. LR11716
FEATURES-SPECIFICATIONS
See page F51 for Standard Materials & Finish
Applicable Third Party Standards
UL Standards: 886 and 1203
CSA Standard: C22.2 No. 30
Fed Spec: W-C-586D
Mil Spec: F-28675
Dimensions
C Type
L Type
j 1/2”, 3/4” and 1” GEC Bodies L isted and Certi ed for:
Class I, Div. 1 & 2, Groups B, C, D
Class I, Zones 1 & 2, Groups IIB + H2
Class II, Div. 1 & 2, Groups E, F, G
Class III
Type 4X (NEMA)
CATALOG NUMBER
KILLARK
GEMC-1 — 1/2”
GEMC-2 — 3/4”
GECCT-1 GECCT-1M 1/2”
GECCT-2 GECCT-2M 3/4”
GECCT-3 GECCT-3M 1”
GESCT-3 GESCT-3M 1”
GESCT-4 GESC T-4M 1-1/4 ”
GEJC T-5 GE JCT-5 M
GEJC T-6 GE JCT-6M 2”
GEM L-1 — 1/2”
GEML-2 — 3/4”
GECLT-1 GECLT-1M 1/2”
GECLT-2 GECLT-2M 3/4”
GECLT-3 GECLT-3M 1”
GESLT-3 GES LT-3 M 1”
GESLT-4 GES LT-4 M 1-1/4”
GEJLT-5 G EJLT-5M
GEJLT- 6 G EJLT-6M 2”
* For GROUP B applications, contact factory.
ALUM.
DURALOY
IRON
HUB
SIZE
1-1/ 2”
1-1/ 2”
A B C D E F
2-13 /16”
(71)3”(76)
2-13 /16”
(71)3”(76)
3-11/16”
(94)
3-11/16”
(94)
3-11/16”
(94)
5-1/16”
(128)
5-1/16”
(128)
6-1 /4”
(159)
6-1 /4”
(159)
2-13 /16”
(71)3”(76)
2-13 /16”
(71)3”(76)
3-11/16”
(94)
3-11/16”
(94)
3-11/16”
(94)
5-1/16”
(128)
5-1/16”
(128)
6-1 /4”
(159)
6-1 /4”
(159)
C TYPE OUTLET BODY*
DIMENSIONS
3-5/8”
(92)
3-5/8”
(92)
3-5/8”
(92)
4-1/8 ”
(105)
4-1/8 ”
(105)
4-3/8”
(111)
4-3/8”
(111)
2-1/16 ”
2-1/16 ”
2-11/16”
2-11/16”
2-11/16”
3-9/16”
3-9/16”
(52)
(52)
(68)
(68)
(68)
(90)
(90)
4-7/ 8”
(124)
4-7/ 8”
(124)
2-5/16”
(79)
2-5/16”
(79)
2-3/4”
(70)1”(25)
2-3/4”
(70)1”(25)
2-3/4”
(70)1”(25)
3-7/16”
(87)
3-7/16”
(87)
3-9/16”
(90)
3-9/16”
(90)
L TYPE OUTLET BODY*
3-5/8”
(92)
3-5/8”
(92)
3-5/8”
(92)
4-1/8 ”
(105)
4-1/8 ”
(105)
4-3/8”
(111)
4-3/8”
(111)
2-1/16 ”
2-1/16 ”
2-11/16”
2-11/16”
2-11/16”
3-9/16”
3-9/16”
(52)
(52)
(68)
(68)
(68)
(90)
(90)
4-7/ 8”
(124)
4-7/ 8”
(124)
2-5/16”
(79)
2-5/16”
(79)
2-3/4”
(70)1”(25)
2-3/4”
(70)1”(25)
2-3/4”
(70)1”(25)
3-7/16”
(87)
3-7/16”
(87)
3-9/16”
(87)
3-9/16”
(87)
GE Outlet Bodies, contact factory
COVER
OPENINGS
11/16”
(17)
11/16”
(17)
1-1/ 16 ”
(27)
1-1/ 16 ”
(27)
1-3/16”
(30)
1-1/ 2”
(38)
11/16”
(17)
11/16”
(17)
1-1/ 16 ”
(27)
1-1/ 16 ”
(27)
1-3/16”
(30)
1-1/ 2”
(38)
13/16”
13/16”
13/16”
13/16”
1-1/ 8”
1-1/ 8”
1-3/16”
1-3/16”
1-3/16”
13/16”
13/16”
13/16”
13/16”
13/16”
1-1/ 8”
1-3/16”
1-3/16”
1-3/16”
(21)
(21)
(21)
(21)
(28)
(28)
(30)
(30)
(30)
(21)
(21)
(21)
(21)
(28)
(28)
(30)
(30)
(30)
2-1/16 ”
(52)
2-1/16 ”
(52)
2-11/16”
(68)
2-11/16”
(68)
2-11/16”
(68)
3-9/16”
(90)
3-9/16”
(90)
4-7/ 8”
(124)
4-7/ 8”
(124)
2-1/16 ”
(52)
2-1/16 ”
(52)
2-11/16”
(68)
2-11/16”
(68)
2-11/16”
(68)
3-9/16”
(90)
3-9/16”
(90)
4-7/ 8”
(124)
4-7/ 8”
(124)
For ATEX and IEC Ex certified
VOLUME
CU. IN.
8
8
18
18
19
42
42
75
75
8
8
18
18
18
42
42
75
75
Page 3

ALUMINUM AND IRON OUTLET BODIES
GEC
T Ty pe
FEATURES-SPECIFICATIONS
See page F51 for Standard Materials & Finish
Applicable Third Party Standards
UL Standards: 886 and 1203
CSA Standard: C22.2 No. 30
Fed Spec: W-C-586D
Mil Spec: F-28675
Dimensions
T Ty pe
X Ty pe
For ATEX and
IEC Ex certified
GE Outlet Bodies,
contact factory
j 1/2”, 3/4” and 1” GEC Bodies
Listed and Certi ed for:
Class I, Div. 1 & 2, Groups B, C, D
Class I, Zones 1 & 2, Groups IIB + H2
Class II, Div. 1 & 2, Groups E, F, G
Class III
Type 4X (NEMA)
LB Type
GES
X Ty pe
CATALOG NUMBER
KILLARK
GEM T-1 — 1/2”
GEM T-2 — 3/4”
GEC TT-1 GEC TT-1M 1/2”
GEC TT-2 GECTT-2M 3/4”
GECTT-3 GECTT-3M 1”
GESTT-3 G ES TT- 3M 1”
GESTT-4 GESTT-4M 1-1/4”
GEJT T-5 GEJ TT-5M 1-1/ 2”
GEJT T-6 GEJ TT-6M 2”
GEM X-1 — 1/ 2”
GEMX-2 — 3/4”
GEC XT-1 GECX T-1M 1/2”
GEC XT-2 GECXT-2M 3 /4”
GEC XT-3 GECXT-3M 1”
GESXT-3 GE SX T-3M 1”
GESXT-4 GESXT-4M 1-1 /4”
GEJX T-5 GE JXT-5M 1-1 /2”
GEJX T-6 GE JXT-6M 2”
GEMLB-1 — 1/2”
GEMLB-2 — 3/4”
GEC LBT-1
GEC LBT-2
GEC LBT-3
GESLBT-3
GESLBT-4
GEJLBT-5 GEJLBT-5M 1-1/2 ”
GEJLBT-6 GEJ LBT-6M 2”
* For GROUP B applications, contact factory.
ALUM.
DURALOY
IRON
GEC LBT-1M 1/2”
GECLBT-2M 3/4”
GECLBT-3M 1”
GESLBT-3M 1”
GESLBT-4M 1-1/4 ”
HUB
SIZE
KILLARK FITTINGS
• 1/2”, 3/4” and 1” Bodiesj
Class I, Div. 1 & 2, Groups C & D
Class I, Zone 1, Groups IIB, IIA
• 1-1/4”, 1-1/2”, and 2” Bodies
Class I,Div. 1 & 2, Group D
Class I, Zone 1, Group IIA
• Class II, Div. 1 & 2, Groups E, F, G
• Class III
• For GEJ Series CSA applications for Class I
Group C, seal conduit within 18 inches
File No. E 10514
GEJ
LB Typ e
T TYPE OUTLET BODY*
A B C D E F
2-13 /16”
(56)3”(76)
2-13 /16”
(56)3”(76)
3-11/16”
(93)
3-11/16”
(93)
3-11/16”
(93)
5-1/16”
(129)
5-1/16”
(129)
6-1/4”
(159)
6-1/4”
(159)
3-5/8”
(92)
3-5/8”
(92)
3-5/8”
(92)
4-1/8 ”
(105)
4-1/8 ”
(105)
4-3/8”
(111)
4-3/8”
(111)
2-1/ 16”
(52)
2-1/ 16”
(52)
2-11/ 16”
(68)
2-11/ 16”
(68)
2-11/ 16”
(68)
3-9/16”
(90)
3-9/16”
(90)
4-7/ 8”
(124)
4-7/ 8”
(124)
X TYPE OUTLET BODY*
2-13 /16”
(56)3”(76)
2-13 /16”
(56)3”(76)
3-11/16”
(93)
3-11/16”
(93)
3-11/16”
(93)
5-1/16”
(129)
5-1/16”
(129)
6-1/4”
(159)
6-1/4”
(159)
3-5/8”
(92)
3-5/8”
(92)
3-5/8”
(92)
4-1/8 ”
(105)
4-1/8 ”
(105)
4-3/8”
(111)
4-3/8”
(111)
2-1/ 16”
(52)
2-1/ 16”
(52)
2-11/ 16”
(68)
2-11/ 16”
(68)
2-11/ 16”
(68)
3-9/16”
(90)
3-9/16”
(90)
4-7/ 8”
(124)
4-7/ 8”
(124)
LB TYPE OUTLET BODY*
2-13 /16”
(56)3”(76)
2-13 /16”
(56)3”(76)
3-11/16”
(93)
3-11/16”
(93)
3-11/16”
(93)
5-1/16”
(129)
5-1/16”
(129)
6-1/4”
(159)
6-1/4”
(159)
3-5/8”
(92)
3-5/8”
(92)
3-5/8”
(92)
4-1/8 ”
(105)
4-1/8 ”
(105)
4-3/8”
(111)
4-3/8”
(111)
2-1/ 16”
(52)
2-1/ 16”
(52)
2-11/ 16”
(68)
2-11/ 16”
(68)
2-11/ 16”
(68)
3-9/16”
(90)
3-9/16”
(90)
4-7/ 8”
(124)
4-7/ 8”
(124)
Certified File No. LR11716
DIMENSIONS
2-5/16
(59)
2-5/16
(59)
2-3/4”
(70)1”(25)
2-3/4”
(70)1”(25)
2-3/4”
(70)1”(25)
3-7/ 16”
(87)
3-7/ 16”
(87)
3-9/16”
(90)
3-9/16”
(90)
2-5/16
(59)
2-5/16
(59)
2-3/4”
(70)1”(25)
2-3/4”
(70)1”(25)
2-3/4”
(70)1”(25)
3-7/ 16”
(87)
3-7/ 16”
(87)
3-9/16”
(90)
3-9/16”
(90)
2-5/16
(59)
2-5/16
(59)
2-3/4”
(70)1”(25)
2-3/4”
(70)1”(25)
2-3/4”
(70)1”(25)
3-7/ 16”
(87)
3-7/ 16”
(87)
3-9/16”
(90)
3-9/16”
(90)
11/16”
(17)
11/16”
(17)
1-1/ 16”
(27)
1-1/ 16”
(27)
1-3/16”
(30)
1-1/ 2”
(38)
11/16”
(17)
11/16”
(17)
1-1/ 16”
(27)
1-1/ 16”
(27)
1-1/ 2”
(38)
1-1/ 2”
(38)
11/16”
(17)
11/16”
(17)
1-1/ 16”
(27)
1-1/ 16”
(27)
1-1/ 2”
(38)
1-1/ 2”
(38)
GE SERIES
COVER
OPENINGS
13/16”
13/16”
13/16”
13/16”
13/16”
1-1/ 8”
1-1/ 8”
1-3/16”
1-3/16”
13/16”
13/16”
13/16”
13/16”
13/16”
1-1/ 8”
1-1/ 8”
1-3/16”
1-3/16”
13/16”
13/16”
13/16”
13/16”
13/16”
1-1/ 8”
1-1/ 8”
1-3/16”
1-3/16”
(21)
(21)
(21)
(21)
(21)
(29)
(29)
(30)
(30)
(21)
(21)
(21)
(21)
(21)
(29)
(29)
(30)
(30)
(21)
(21)
(21)
(21)
(21)
(29)
(29)
(30)
(30)
2-1/ 16”
(52)
2-1/ 16”
(52)
2-11/ 16”
(68)
2-11/ 16”
(68)
2-11/ 16”
(68)
3-9/16”
(90)
3-9/16”
(90)
4-7/ 8”
(124)
4-7/ 8”
(124)
2-1/ 16”
(52)
2-1/ 16”
(52)
2-11/ 16”
(68)
2-11/ 16”
(68)
2-11/ 16”
(68)
3-9/16”
(90)
3-9/16”
(90)
4-7/ 8”
(124)
4-7/ 8”
(124)
2-1/ 16”
(52)
2-1/ 16”
(52)
2-11/ 16”
(68)
2-11/ 16”
(68)
2-11/ 16”
(68)
3-9/16”
(90)
3-9/16”
(90)
4-7/ 8”
(124)
4-7/ 8”
(124)
F
F
H
H
VOLUME
CU. IN.
8
8
19
19
19
42
42
75
75
8
8
19
19
19
42
42
75
75
8
8
19
19
19
42
42
75
75
N
I
N
I
T
T
G
G
T
T
I
S
I
S
C
C
A
A
O
O
Z
Z
L
L
Page 4

KILLARK FITTINGS
N
I
N
I
T
T
G
G
T
T
I
S
I
S
F
F
H
H
A
A
Z
Z
C
C
O
O
L
L
GE SERIES
ALUMINUM AND IRON OUTLET BODIES
• 1/2”, 3/4” and 1” Bodiesj
Class I, Div. 1 & 2, Groups C & D
Class I, Zone 1, Groups IIB, IIA
• 1-1/4”, 1-1/2”, and 2” Bodies
Class I,Div. 1 & 2, Group D
Class I, Zone 1, Group IIA
• Class II, Div. 1 & 2, Groups E, F, G
GEM
LA Type
GE SX AT
XA Type
• Class III
• For GEJ Series CSA applications for Class I
Group C, seal conduit within 18 inches
File No. E 10514
GEM
TA Ty pe
FEATURES-SPECIFICATIONS
See page F53 for Standard Materials & Finish
Applicable Third Party Standards
UL Standards: 886 and 1203
CSA Standard: C22.2 No. 30
Fed Spec: W-C-586D
Mil Spec: F-28675
Dimensions
TAT Type XAT Type
GEM
CA Typ e
CATALOG NUMBER
KILLARK
ALUM.
GEM LA-1 — 1/2”
GEMLA-2 — 3/4”
GEM TA-1 — 1/2”
GEMTA-2 — 3/4”
GECTAT-2 GECTAT-2M 3/4”
GECXAT-1
GECXAT-2
GECXAT-3
GESX AT-4
DURALOY
IRON
GECXAT-1M 1/ 2”
GECXAT-2M 3/4”
GECXAT-3M
GESXAT-4M
HUB
SIZE
1”
1-1/4”
GEC
EAT Type
Certified File No. LR11716
LA TYPE OUTLET BODY*
DIMENSIONS
A B C D E F
2-13 /16”
(56)3”(76)
2-13 /16”
(56)3”(76)
2-1/16 ”
(52)
2-1/16 ”
(52)
2-5/16”
(59)
2-5/16”
(59)
11/16”
(17)
11/16”
(17)
TAT TYPE OUTLET BODY*
2-13 /16”
(56)3”(76)
2-13 /16”
(56)3”(76)
3-11/16”
(94)
3-5/8”
(92)
2-1/16 ”
(52)
2-1/16 ”
(52)
2-11/16”
(68)
2-5/16”
(59)
2-5/16”
(59)
2-3/4”
(70)1”(25)
11/16”
(17)
11/16”
(17)
XAT TYPE OUTLET BODY*
3-11/16”
3-11/16”
3-11/16”
5-1/16”
(94)
(94)
(94)
(128)
3-5/8”
(92)
3-5/8”
(92)
3-5/8”
(92)
4-1/8 ”
(105)
2-11/16”
(68)
2-11/16”
(68)
2-11/16”
(68)
3-9/16”
(90)
2-3/4”
(70)1”(25)
2-3/4”
(70)1”(25)
2-3/4”
(70)1”(25)
3-7/16”
(87)
1-1/ 16 ”
(27)
13/16”
(21)
13/16”
(21)
13/16”
(21)
13/16”
(21)
13/16”
(21)
13/16”
(21)
13/16”
(21)
13/16”
(21)
1-3/16”
(30)
COVER
OPENINGS
2-1/16 ”
(52)
2-1/16 ”
(52)
2-1/16 ”
(52)
2-1/16 ”
(52)
2-11/16”
(68)
2-11/16”
(68)
2-11/16”
(68)
2-11/16”
(68)
3-9/16”
(90)
VOLUME
CU. IN.
8
8
8
8
19
19
19
19
42
CAT Type EAT Type
j 1/2”, 3/4” and 1” GEC Bodies L isted and Certi ed for:
Class I, Div. 1 & 2, Groups B, C, D
Class I, Zones 1 & 2, Groups IIB + H2
Class II, Div. 1 & 2, Groups E, F, G
Class III
Type 4X (NEMA)
1-1/4”
2-13 /16”
(56)3”(76)
2-13 /16”
(56)3”(76)
3-11/16”
(94)
5-11 /16
(144)
3-11/16”
(94)
GEMCA-1 — 1/2”
GEMCA-2 — 3/4”
GECCAT-1 GECCAT-1M 1”
GESCAT-4
GECEAT-2 GECEAT-2M 3/4”
* For GROUP B applications, contact factory.
GESCAT-4 M
CAT TYPE OUTLET BODY*
2-1/16 ”
2-5/16”
3-5/8”
(92)
4-1/8 ”
(105)
(52)
2-1/16 ”
(52)
2-11/16”
(68)
3-9/16”
(90)
(59)
2-5/16”
(59)
2-3/4”
(70)1”(25)
3-7/16”
(87)
EAT TYPE OUTLET BODY*
3-5/8”
2-11/16”
(92)
(68)
2-3/4”
(70)1”(25)
For ATEX and IEC Ex certified
GE Outlet Bodies, contact factory
11/16”
(17)
11/16”
(17)
1-1/ 16 ”
(27)
13/16”
(21)
1-3/16”
(30)
13/16”
(21)
1-3/16”
(30)
13/16”
(21)
2-1/16 ”
(52)
2-1/16 ”
(52)
2-11/16”
(68)
3-9/16”
(90)
2-11/16”
(68)
8
8
19
42
19