FXS SERIES
FACTORY SEALED TUMBLER SWITCHES AND GROUND FAULT INTERRUPTER
Class I, Div. I & 2, Groups C, D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E, F, G
Class Ill
Tumbler Switch
Complete Unit
(Box and Cover)
Ground Fault Interupter
Complete Unit
(Box and Cover)
For GFI Protection
with Receptacle,
See pag e PR20
NEMA 3, 7 (C, D) 9 (E, F, G)
R
R
T
T
O
O
N
N
L
L
S
O
S
O
C
C
H
H
C
C
A
A
O
O
Z
Z
L
L
FEATURES-SPECIFICATIONS
Applications
FXS Tumbler Switches are suitable for
applications where making, breaking or
changing connections in an electrical circuit
is required and where conditions of load do
not exceed the switch ratings.
- File E5 336 0 and/or Ffile E10 501
Certified - File LR11712
See files for details or call Killark.
Applications
FXS Ground Fault Interrupters are designed
to interrupt a circuit when a ground fault
is detected on equipment which may
be handled by personnel in hazardous
locations.
Features
• Test and Reset push buttons are provided
on cover assembly. Unit should be tested
monthly
• Includes new GFI to meet latest UL943
GFCI standards revisions
• Exterior gasket provides NEMA 3
weatherproof protection
• Ground boss for grounding in the splice
box
• Color coded wiring
• Captive cover bolts are made from
stainless steel
Electrical Rating
GFI units are rated at 20A, 120 VAC,
60HZ. Class A.
4-6 miliamp trip setting
Trip Time-UL Curve
- File E80595
Certified - File LR61895
See files for details or call Killark.
FXS TUMBLER SWITCHES
CATALOG NUMBER
COMPLETE UNIT
COVER WITH
SWITCH
FXS-1C
FXS-2C
FXS-8C
FXS-3C
FXS-5C
FXS-6C
FXS-1D
FXS-2D
FXS-4C — — — 4-WAY
jRated 15 amperes, 240/48 0 VAC., 3Ø; 3HP-240 VAC., 5 HP-480 VAC.
kHorsepower rated 1 HP at 120 VAC, 2 HP at 240 VAC.
(BOX, COVER AND SWITCH)
DEAD-END FEED -THRU
FXS-11C FXS-41C 1/2”
FXS-21C FXS-51C 3/4”
FXS-12 C FXS-42C 1/2”
FXS-22C FXS-52C 3/4”
FXS-18 C FXS-48C 1/2”
FXS-28C FXS-58C 3/4”
FXS-13 C FXS-43C 1/2”
FXS-23C FXS-53C 3/4”
FXS-15 C FXS-45C 1/2”
FXS-25C FXS-55C 3/4”
FXS-16 C FXS-46C 1/2”
FXS-26C FXS-56C 3/4”
FXS-11D FXS-41D 1/2”
FXS-21D FXS -51D 3/4”
FXS-12D FXS-42D 1/2”
FXS-22D FXS-52D 3/4”
HUB SIZE SWITCH STYLE
1-POLE
2-POLE
3-POLE
3-WAY/
SPDT (NO OFF)
SPDT (CENTER
OFF)
DPDT (NO OFF)
1-POLE
2-POLE
SWITCH RATING
120/ 277 VAC, 1Ø
20 Ak
20 Ak
j
20 Ak
20 Ak
20 Ak
30 Ak
30 Ak
20 Ak
FXS GROUND FAULT INTERRUPTER†
CATALOG NUMBER
COMPLETE UNIT COVER ASSEMBLY BACK BOX*
FXS-GFI-1020 FXS-GFIO3 FXB-1
FXS-GFI-2020 FXS-GFIO3 FXB-2 3/4”
FXS-GFI-3020 FXS-GFIO3 FXB-3 1”
FXS-GFI-1120 FXS-GFIO3 FXB-4
FXS-GFI-2120 FXS-GFIO3 FXB-5 3/4”
FXS-GFI-3120 FXS-GFIO3 FXB-6 1”
For control stations with 1” conduit opening or for double gang assemblies, order cover with device and box as
separate components.
* Boxes and covers shipped separately.
† See page DE25 for additional ground fault control stations.
DEAD END
FEED THRU
HUB SIZE
1/2”
1/2”
FXS GROUND FAULT INTERRUPTER WITH LED LAMP
CATALOG NUMBER FOR COVER ASSEMBLY
* Order FXB back box as separate item.
FXS-GFIO3PL