Killark-Hubbell Electrical Products DEDS SERIES Catalog Page

KILLARK DISTRIBUTION
DISCONNECT SWITCHES • POLE / NON-FUSIBLE
Class II, Div. 1 & 2, Groups E, F, G Class III NEMA 3R, 4, 9 (E, F, G)
Liste d - File E5 329 0
Certified - File LR11714 See files for details or call Killark.
DEDS SERIES
U
B
U
B
T
T
R
R
I
I
T
T
O
O
S
S
N
I
N
I
D
D
H
H
C
C
A
A
O
O
Z
Z
L
L
FEATURES-SPECIFICATIONS
Applications
Hazardous areas due to the presence
of combustible dusts or easily ignitable fibers or flyings
Use in damp or wet locations. Either
indoor or outdoor installations
Installations such as feedmills, grain
elevators, coal handling facilities, certain chemical, fertilizer and food processing industries where either hazardous or non­hazardous dusts are handled or stored
Use in accordance with the NEC/CEC
where a horsepower rated quick make­quick break disconnect means for a motor and its controller is permitted
Features
(30-60-100 Amp Housing Styles)
Bolted and gasketed cabinet type
construction insures the exclusion of conductive or combustible dusts from entering the assembly. Enclosure and external handle is copper-free aluminum alloy (less than 4/10 of 1%)
Cover bolts are stainless steel
External handle is vault type with standard
provisions for locking in the “OFF” position with up to three padlocks
Provisions for locking in “ON” position
available as factory modification. (Add suffix SU40 to catalog number)
Cutler-Hammer Type-DS Switches
Two cast conduit hubs; one top and one
bottom
Internal disconnect handle mechanism is
a sliding plate mounted to the cover
DEDS DISCONNECT SWITCHES
CATALOG NUMBER
ENCLOSURE WITH
SWITCH
WITH SWITCH
AND AUXILIARY
CONTACTS
DEDS-30 DEDS-30A DEDS-30AA DEDS-A 30 AMP DEDS-60 DEDS-60A DEDS-60AA DEDS-B 60 AMP
DED S-100 DED S-100A DED S-100AA DEDS-B 100 AMP
Auxiliary Switch Kits are available for separate control circuit applications. Each auxiliary switch has one normally open and one normally closed contact. Each switch includes three soldered, identi ed leads.
Rated 15 amps at 25 0 volts maximum.
ENCLOSURE
ENCLOSURE WITH
SWITCH AND
TWO AUXILIARY
CONTACTS
ENCLOSURE ONLY
(WITHOUT SWITCH
OR AUXILIARY
CONTACTS)
SWITCH RATING
DEDS ELECTRICAL RATINGS
SWITCH
AMPERES
30 5 10 20 25 7-1/ 2 60 10 20 40 60 15
100 15 30 75 75 25
120 VAC 240 VAC 480 VAC 600 VAC 250 VDC
MAXIMUM HORSEPOWER–THREE PHASE–3-POLE
DEDS DIMENSIONS
ENCLOSURE
CATALOG NUMBER
DEDS-A 1-1/4”
DEDS-B 2”
Dimensions
CONDUIT
SIZE
A B C D E F G H J
8-3/8”
8-13/16”
(213)
10-7/8”
(276)
(224)
9-1 /8”
(232)
7/16 ”
(11)
7/16 ”
(11)
10-1/4 ”
(260)
13-7/ 8”
(252)
7-3 /8 ”
(187)
7-3 /4”
(197)
12-1/8 ”
(308)
15-3/8”
(39 1)
1-3/8”
(35)
1-3/4”
(44)
6-7/ 8”
(175)
6-7/ 8”
(175)
MODIFICATIONS
SUFFIX NUMBER DESCRIPTION
SU3j
SU17 100 Amp solid neutral SU40 Lock “on” for handle
KIT-251 100 Amp ground lug
j SU3 voids NEMA 4 ratings
EST. ENC L.
WT. LBS (KG)
2”
(51)
2”
(51)
Drain and breather
14.50
(6.57)
19.5 0
(8.84)
Note: Space for additional drill & top conduit opening. 1-1/4” for DEDS-A. 2” for DEDS -B. Also is location for SU3 drain and breather when required.
Loading...