KILLARK ENCLOSURES
S
S
U
O
U
O
L
L
R
R
C
C
E
E
N
S
N
S
E
E
H
H
A
A
Z
Z
DB SERIES
C
C
O
O
L
L
FEATURES-SPECIFICATIONS
Applications
• Hazardous locations due to the presence
of combustible dusts or easily ignitable
fibers or flyings
• Damp or wet locations (raintight)
Features
• Copper-free aluminum (less than 4/10 of
1%)
• Surface mounting type box with raised
cover
• Mounting lugs included as standard
• Cover screws are stainless steel
• Gaskets mechanically fastened to cover
• All DB boxes cast with wall thicknesses
suitable to drill and tap conduit openings.
Conduit openings may be factory or
field installed. See chart for conduit size
limitations. See page E55 for conduit
opening data
• Enclosures are available blank or with
factory modifications, options and
accessories. See catalog pages E40-45 for
additional details
JUNCTION BOXES
MODIFICATIONS
CATALOG NUMBER DESCRIPTION
KIT-251 100 Amp ground lug
KIT-252 225 Amp ground lug
SUFFIX NUMBER DESCRIPTION
SU2 Hinge installed
SU3 Drain and breather installed
SU8 Pan mounting studs
Class II, Dlv. 1 & 2, Groups E, F, G
Class Ill
NEMA 3R, 4, 4X, 9 (E, F, G)
- File E10514
Certified - File LR11716
File 2 5132
See files for d etails or call Killar k.
BOX WIDTH “J” DIMENSION
6 1
8 THRU 20 1-3/8
24 AND LARGER 2
KILLARK ENCLOSURES
DB SERIES
JUNCTION BOXES
Class II, Dlv. 1 & 2, Groups E, F, G
Class Ill
NEMA 3R, 4, 4X, 9 (E, F, G)
- File E10514
Certified - File LR11716
File 2 5132
See files for d etails or call Killar k.
FEATURES-SPECIFICATIONS
DB ENCLOSURES WITH MOUNTING LUGS
CATALOG
NUMBER
NOMINAL DIMENSIONS
OUTSIDE INSIDE COVER OPENING
MOUNTING
DIMENSIONS
A B C D E F G H X Y
DB-664 6” 6” 4” 5-3/8” 5-3/8” 4-7/3 2” 4-1/4 ” 4-1/4 ” 7-1/4” 4-1/4 ” HINGE-4 6 30 7-6 2 2 1 row of 1 = 1
DB-884 8” 8” 4” 7-3/ 8” 7-3/ 8” 4-5/8” 5-7/16” 5-7/ 16” 9 -1/ 4” 5-7/16 ” HINGE-4 6 247-8 2 2 2 rows of 2 = 4
DB-886 8” 8” 6” 7-3/ 8” 7-3/ 8” 6-5/8” 5-7/16 ” 5 -7/16” 9-1/ 4” 5-7/16 ” HINGE-4 6 247-8 2 2 2 rows of 2 = 4
DB-8106 8” 10” 6” 9-3/8” 7-3/8” 6-5/8” 7-9/3 2” 5-5/16” 11-1/4” 5-5/16” HINGE-4 6247-10 2 2 2 rows of 2 = 4
DB-6126 6” 12” 6” 11-3/8 ” 5-3/8” 6-7/32” 10-3/16” 4-5/16” 13-1 /4 ” 4-5/16” HINGE-4 630 7-12 2 2 4 rows of 1 = 4
DB-8146 8” 14” 6” 13- 3/ 8” 7-3/ 8” 6-5/8” 11-1/4” 5-5/16” 15-1/4” 5-5/16” HINGE-4 6247-14 2 2 4 rows of 2 = 8
DB-8188 8”
DB-1010 6 10 ” 10” 6” 9-3/8” 9-3/8” 6 -1/ 2” 7-5/16” 7-5/16” 11-1/4 ” 7-5/16” HINGE-4 6248-10 2 2 2 rows of 2 = 4
DB-10148 10” 14” 8” 13- 3/ 8” 9-3/8” 8 -1/ 2” 11-5/16” 7-5/16” 11-1/4 ” 7-5/16” HINGE-4 6248-14 2 2 4 rows of 2 = 8
DB-12148 12” 14” 8” 13-3/8” 11-3 /8” 8 -7/16” 11-5/16” 9-5/16” 15-1/ 4” 9-5/16” HINGE-4 6249-14 4 2 4 rows of 3 = 12
DB-1216 8 12” 16” 8” 15- 3/ 8” 11-3 /8” 8-9/16 ” 13-1/ 4” 9 -1/ 4” 14 -1/4” 9-1/4 ” HINGE-4 6249-16 4 2 4 rows of 3 = 12
DB-1218 8 12” 18” 8” 17-3/ 8” 11-3/ 8” 8-5/8” 15-5/32” 9-5/32” 19 -1/4” 9-5/32” HINGE-4 6249 -18 4 2 5 rows of 3 = 15
DB-12248 12” 24” 8” 23-3/8” 11-3 /8” 8-1 /6” 21-5/16” 9-5/16” 2 5-1/4 ” 9-5/16” HINGE-4 6249-24 4 2 8 rows of 3 = 24
DB-1618 8 16” 18 ” 8” 17-3 /8 ” 15-3 /8” 8-9/16” 15-5/16” 13-5/16” 19-1/4” 13-5/16” HINGE-4 625 0-18 4 2 5 rows of 4 = 20
DB-16248 16” 24” 8” 23-3/8” 15-3/8” 8-9/16” 21-5/16”
DB-163 68 16” 36” 8” 35-3/8” 15- 3/ 8” 8-9 /16” 33-5/16” 13-5/16” 37-1/4” 13-5/16” HINGE-4 6250-36 4 2 12 rows of 4 = 48
DB-20248 20” 24” 8” 23-3/8” 19-3/ 8” 8 -9 /16” 2 1-1/2 ” 17-1/2” 2 5-1/4 ” 17-1/2” HINGE-4 6251-24 4 2 8 rows of 6 = 48
DB-203010 20” 30” 10” 29-3/8” 19-3/8” 10-5/8” 27-1/ 4” 17-1 /4 ” 31-1/4” 17-1/4” HINGE-4 6251-30 4 2 10 rows of 6 = 60
DB-243010 24” 30” 10” 29 -1/8” 23 -1/8” 10-7/16” 26” 20” 32” 20” *HIN GE-11L 6252-30 4 4 10 rows of 7= 70
DB-243610 24” 36” 10” 35-3/8” 23-3/8” 10 -7/16” 32” 20” 38” 20” *HIN GE -11L 6252-36 4 4 12 rows of 7 = 8 4
j These limits are necessary to assure 3-1/2 full threads to meet Class II requirements.
k Boxes are not factory machined for a mounting pan. Add suffix SU8 if box is to be supplied with pan mounting studs.
l When pan is ordered without box, it is supplied with studs and hardware for eld mounting. Machining of box for pan studs is required.
* 24” wide enclosures are furnished with hinged covers on left side as a standard feature.
† Maximum number of “G” series control operators permitted in cover, down + across = total.
Use short style “G” series operators.
18” 8” 17-3/8” 7-3/ 8” 8-5/8” 15-1/4” 5-5/16” 19-1/4” 5-5/16” HINGE-4 6247-18 2 2 5 rows of 2 = 10
13-5/16” 2 5-1/4 ” 13-5/16” HINGE-4 6250-24 4 2 8 rows of 4 = 32
CATALOG NUMBER
OPTIONAL
HINGE
OPTIONAL
MOUNTING
TYPE
PAN
CONDUIT OPENING
kl
MAX SIZE
ENDS
j
BACK &
SIDE
MAXIMUM
NUMBER OF
OPERATORS†
S
S
U
O
U
O
L
L
R
R
C
C
E
E
N
S
N
S
E
E
H
H
C
C
A
A
O
O
Z
Z
L
L