for the PAT1000-8T/PAT1500-5.3T
PART NO. Z1-005-610, IB025035
The newest version of the operation manual can be downloaded from Download service of Kikusui website.
Feb. 2018
Setup Guide
Regulated DC Power Supply PAT-T series
8kW type4kW type
PAT20-200T
PAT40-100T
PAT60-67T
PAT160-25T
PAT20-400T
PAT30-266T
PAT40-200T
PAT60-133T
PAT80-100T
PAT160-50T
8kW type (Custom model)
PAT1000-8T
PAT1500-5.3T
Thank you for purchasing the PAT-T Series Regulated DC Power
Supply.
The PAT-T Series is a low-noise, highly efficient Constant
Voltage (CV)/ Constant Current (CC) automatic crossover
power supply that employs a software switching system.
PAT250-32T
PAT350-22.8T
PAT500-16T
PAT650-12.3T
PAT850-9.4T
(SPEC21163)
(SPEC21164)
Checking the Package Contents
When you receive the product, check that all accessories are
included and that the accessories have not been damaged
during transportation. If any of the accessories are damaged
or missing, contact your Kikusui agent or distributor. We
recommend that you save all packing materials, in case the
product needs to be transported at a later date.
Accessory
● 4 kW type/ 8 kW type
OUTPUT terminal
cover [Q1-500-106]
Model of rated output
20 V to 850 V (2 sets)
OUTPUT terminal cover set
[M3-112-059]
Pins 30 pcs.
[84-49-0100]
[M3-112-027]
[91-80-6940]
Chassis connection wire set
(1 set)
* Chassis connection wire only
Pins 30 pcs.
[84-49-0100]
PAT-T Series models
The PAT-T Series consists of the 4 kW type and 8 kW type. On
the 4 kW type, you can select the input mode: single-phase
input or three-phase input. The 8 kW type is three-phase input.
The 8 kW type consists of the 200 V input model and 400 V
input model (200 V input only for the PAT1000-8T/PAT1500-
5.3T).
Output power Model Input mode Rated voltage Input rating
4 kW type PAT20-200T Single-
PAT40-100T 40 V
PAT60-67T 60 V
PAT160-25T 160 V
8 kW type PAT20-400T Three-phase 20 V 200 V
PAT30-266T Three-phase 30 V 200 V
PAT40-200T Three-phase 40 V 200 V
PAT60-133T Three-phase 60 V 200 V
PAT80-100T Three-phase 80 V 200 V
PAT160-50T Three-phase 160 V 200 V
PAT250-32T Three-phase 250 V 200 V
PAT350-22.8T Three-phase 350 V 200 V
PAT500-16T Three-phase 500 V 200 V
PAT650-12.3T Three-phase 650 V 200 V
PAT850-9.4T Three-phase 850 V 200 V
PAT1000-8T Three-phase 1000 V 200 V
PAT1500-5.3T Three-phase 1500 V 200 V
phase/
three-phase
selectable
20 V 200 V
400 V
400 V
400 V
400 V
400 V
400 V
400 V
400 V
400 V
400 V
400 V
Protection cover
2 sets [84-49-0161]
Model of rated output
20 V to 850 V
J1/J2 connector kit
If necessary, attach to
the product.
Heavy object warning label
(1 pc.) [A8-900-153]
Setup Guide (1pc.)
Output terminal bolt set (2 sets)
* Not included with the PAT1000-8T/PAT1500-5.3T
Rated
voltage
Size M10 set M12 set M10 set M8 set
[1] M1-100-019 M1-100-027 M1-100-019 M1-100-013
[2] M5-101-008 M5-101-009 M5-101-008 M5-101-007
[3] M4-100-008 M4-100-009 M4-100-008 M4-100-007
Socket 2 pcs.
[84-49-0160]
Protection cover 2 sets [84-49-0140]
Model of rated output
1000 V, 1500V
CD-ROM (1 pc.)
Safety information (1pc.)
Quick Reference
(
[1]
[2]
x 2
[3]
4 kW type 8 kW type
20 V to 160 V 20 V, 30 V 40 V to 160 V 250 V to 850 V
Japanese: 1pc.,English: 1pc.)
Socket 2 pcs.
[84-49-0160]
KIKUSUI ELECTRONICS CORP.
1-1-3 Higashiyamata, Tsuzuki-ku, Yokohama,
224-0023, Japan
Tel: +81-45-482-6563 Fax: +81-45-482-6261
PAT-T series 1
Website
http://www.kikusui.co.jp/en
Features
About the PAT-T Documentation
The PAT-T Series is equipped with the following features.
• Reduction of harmonic current and power transmission loss
The power-factor improvement circuit reduces the effects of
harmonic currents on the input power line. It also suppresses the
peak current and reduces the power transmission loss.
• Master-Slave parallel operation
Up to five power supplies can be connected in parallel to expand.
• Output limit function
You can set the upper limit of current and voltage that is applied
when setting the output. This function is used to prevent setting
inappropriate value by mistake.
• Remote interface
Equipped with RS232C as standard. You can select the GPIB,
USB or LAN interface as a factory option. The remote interface
complies with IEEE 488.2 std 1992 and SCPI Specification
1999.0. Because the LAN interface complies with the LXI
standard, the construction of a highly cost-effective system is
possible.
• High efficiency and low noise
The PAT is a highly efficient, low-noise power supply that employs
a software switching system. High power conversion efficiency
has reduced the rise in the internal temperature and has
contributed to the productʼs compact and light design.
• Downsized input distribution device
The input distribution device (breaker) can be downsized,
because the built-in power-factor improvement circuit reduces the
required input current.
• Preset memory function of settings
Up to three output setting presets (combination of current and
voltage) can be saved. You can simply select a preset to set the
output without having to set the voltage and current every time
you use the PAT.
• Output on/off delay function
You can set a delay until the output is actually turned on or off
after turning the OUTPUT switch on or off. For example, this
feature is useful if you want to turn the output on/off by setting a
time offset according to the load characteristics.
• Selectable input power for the three-phase input mode or
single-phase input mode (Only 4 kW type)
The input power mode can be switched from “three-phase input
to single-phase input” or “single-phase input to three-phase input
by the CONFIG setting. In the single- phase input mode, output
current is limited to 75 % of the rating of three-phase input mode.
Precautions Concerning Installation
• Avoid locations where the product is exposed to high
temperature or direct sunlight.
Do not install the product near a heater or in areas subject to
drastic temperature changes.
Operating temperature range: 0 C to +50 C (32 F to 122 F)
Storage temperature range: -25 C to +70 C (-13 F to 158 F)
• Avoid humid environments.
Do not install the product in high-humidity locations–near a boiler,
humidifier, or water supply.
Operating humidity range: 20 %rh to 85 %rh (no condensation)
Storage humidity range: 90 %rh or less (no condensation)
Condensation may occur even within the operating relative
humidity range. If this happens, do not use the product until the
condensation dries up completely.
These manual is intended for users of the product or
persons teaching other users on how to operate the
product.
The manual assumes that the reader has knowledge
about Power Supply.
You can view the PDF file using Adobe Reader 6.0 or later.
You can view the HTML file using Microsoft Internet
Explorer 6.0 or later
The Operation Manual has been prepared with the utmost
care; however, if you have any questions, or note any
errors or omissions, please contact Kikusui distributor/
agent.
If you find any incorrectly arranged or missing pages
in the manual, they will be replaced. If the manual gets
lost or soiled, a new copy can be provided for a fee. In
either case, please contact Kikusui distributor/agent, and
provide the “Kikusui Part No.” given on the cover.
After reading, always keep the manual nearby so that you
may
refer to it as needed.
Documentation Structure
■ User's manual (PDF)
The Userʼs manual is intended for first-time users of this
product. It provides an overview of the product and notes
on usage. It also explains how to configure the product,
operate the product, perform maintenance on the product,
and so on.
■ Setup Guide (This guide)
This guide is intended for first-time users of the product. It
gives an overview of the product, connecting procedures,
etc. Please read through and understand this guide
before operating the product.
■ Quick Reference
The quick reference briefly explains the panel description
and the basic operation of the product.
”
■ Safety information
This document contains general safety precautions for this
product. Keep them in mind and make sure to observe
them.
■ Communication Interface Manual (HTML, PDF)
This manual contains details about remote control.
Interface manual is written for readers with sufficient basic
knowledge of how to control instruments using a personal
computer.
2 PAT-T series
Notations used in the PAT-T manual
Contents of the Included CD-ROM
In this manual, the PAT-T Series regulated DC power supply is
often simply referred to as "the PAT."
The word "PC" used in this manual is a generic term for
personal computers and workstations.
The screen captures used in this manual may differ from the
actual screens that appear on the PAT-T. The screen captures
are merely examples.
The following markings are used in the explanations in the
manual.
WARNING
Indicates a potentially hazardous situation which, if
ignored, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if ignored,
may result in damage to the product or other property.
- Note -
Indicates information that you should know.
- DESCRIPTION -
Explanation of terminology or operation principle.
(SHIFT+key name)
Indicates an operation in which a switch marked in blue is
pressed while holding down the SHIFT key.
Put the included CD-ROM into the CD-ROM drive. In a few
moments, a start window will appear. If the start window does
not appear, open the CD-ROM folder in Windows Explorer, and
then double-click index.html to display the start window.
Accompanying CD-ROM contains following the items.
• Driver
IVI-COM、KI-VISA
• Operation Manual
User's Manual (PDF)
Communication Interface Manual (HTML)
Click the item you want to view to move to the corresponding
page.
PAT-T series 3