![](/html/37/37bc/37bc5996452539916979c54e90aca36b295aeeb698ae8391c53e5f7ca96fffd6/bg1.png)
Issue 2011-04-27
Datasheet 2.70-10.411-01-EN
Product Description
BMR410
BMR410 Controller
Application
The BMR410 is a DDC controller for regulating,
controlling, monitoring and optimizing heating, ventilation
and air conditioning systems.
The BMR410 also has a fieldbus to allow for flexible
enhancement with input and output modules, as well as
with room control modules.
With an integrated Ethernet interface, the BMR410 has a
built in web server to facilitate visualization, remote
control and data backup over a web browser without the
need of any additional software.
Parameterization can be carried out using the BMRTool, the SI Tool or the PS4000.
Additional main features of the BMR410:
■ Native BACnet® in accordance with DIN EN ISO 16484-5 (BACnet® server functionality);
facilitates communication with the BMS by Ethernet or modem.
■ The BMRTool allows you to configure the controller quickly and easily. Plant macros are set to configure the
BMR410 completely, set the associated BMR software objects, configure the parameters and assign the input
and output signals.
■ Simple turn-knob operation with illuminated display
■ Weekly schedule and annual schedule
■ Trend data can be saves and visualized
■ Code keys for quick display and adjustment of plant values at different access levels;
customer-specific plaintext for every parameter
■ Can be operated in 12 languages (Czech, Dutch, English, French, German, Hungarian, Italian, Latvian, Polish,
Russian, Spanish and Swedish)
■ 3 closed-loop control circuits for heating or 2 for ventilation, which can be extended by hardware and software
objects
■ Malfunction message logging with time and date
Content Page
Important Information Regarding Product Safety ..................................................................................................2
Item........................................................................................................................................................................3
Technical Data.....................................................................................................................................................3
Accessories (not included in delivery) .................................................................................................................4
Dimensions..........................................................................................................................................................5
Connectable fieldbus modules.............................................................................................................................6
Connection...........................................................................................................................................................6
Fieldbus Power Supply........................................................................................................................................8
Installation..............................................................................................................................................................9
Opening the Housing ...........................................................................................................................................9
Removal...............................................................................................................................................................10
Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications - Reservado el derecho a modificación - Wijzigingen
voorbehouden - Con riserva di modifiche - Innehåll som skall ändras - Změny vyhrazeny - Zmiany zastrzeżone - Возможны изменения
A változtatások jogát fenntartjuk -
Kieback&Peter GmbH & Co. KG
Tempelhofer Weg 50, 12347 Berlin/Germany
Telefon: +49 30 60095-0, Telefax: +49 30 60095-164
www.kieback-peter.de, info@kieback-peter.com
保留未经通知而改动的权力
A
-
![](/html/37/37bc/37bc5996452539916979c54e90aca36b295aeeb698ae8391c53e5f7ca96fffd6/bg2.png)
Datasheet 2.70-10.411-01-EN Issue 2011-04-27
Product DescriptionBMR410
Important Information Regarding Product Safety
Safety Instructions
This data sheet contains information on installing and commissioning the product "BMR410". Each
person who carries out work on this product must have read and understood this data sheet. If you
have any questions that are not resolved by this data sheet, you can obtain further information from
the supplier or manufacturer.
If the product is not used in accordance with this data sheet, the protection provided will be impaired.
Applicable regulations must be observed when installing and using the device. Within the EU, these
include regulations regarding occupational safety and accident prevention as well as those from the
VDE (Association for Electrical, Electronic & Information Technologies). If the device is used in other
countries, it is the responsibility of the system installer or operator to comply with local regulations.
Mounting, installation and commissioning work on the devices may only be carried out by qualified
technicians. Qualified technicians are persons who are familiar with the described product and who
can assess given tasks and recognize possible dangers due to technical training, knowledge and
experience as well as knowledge of the appropriate regulations.
Legend
WARNING
Indicates a hazard of medium risk which can result in death or severe bodily injury if it is not avoided.
!
CAUTION
Indicates a hazard of low risk which can result in minor or medium bodily injury if it is not avoided.
NOTICE
Indicates a hazard of medium risk which can result in material damage or malfunctions if it is not
avoided.
NOTE
Indicates additional information that can simplify the work with the product for you.
Notes on Disposal
For disposal, the product is considered waste from electrical and electronic equipment (electronic
waste) and must not be disposed of as household waste. Special treatment for specific components
may be legally binding or ecologically sensible. The local and currently applicable legislation must be
observed.
A
Page 2 / 10
![](/html/37/37bc/37bc5996452539916979c54e90aca36b295aeeb698ae8391c53e5f7ca96fffd6/bg3.png)
Issue 2011-04-27
Item
BMR410 DDC controller with operating function and integrated Web server for
Technical Data
Nominal voltage AC 110 V to 230 V AC ± 10%; 50 Hz to 60 Hz; 10 VA
Fuse Fuse S1 630 mA (T) on the mains side
Inputs and outputs 5 binary outputs Voltage-free relay contact max. 5 (3) A; AC
Ports Ethernet RJ45 Data backup; WEB server communication;
Displays Backlit graphic display, LED for error message and bus operation
Operation Knob with confirmation key [SET] and backspace key [ESC]
RAM 8 MB dyn. RAM; 512 kB stat. RAM, 8 MB flash
Mains failure backup Buffered by lithium battery; up to 1 year mains failure; recommended
Degree of protection IP20 (when installed)
Ambient temperature 0 °C to 45 °C
Ambient humidity During operation: 20% to 80% r.h., non-condensing;
Mounting Standard rail EN 50022 in closed housing
Dimensions WxHxD mm 143.5 x 90 x 67
Weight 0.38 kg
Datasheet 2.70-10.411-01-EN
BMR410Product Description
remote control
250 V
2 binary inputs Also for pulse counting up to 80 Hz
8 universal inputs/outputs that can be independently configured as:
- Binary output
- Binary input
- Analog output
- Analog input See table "Sensor Types", page 4.
Cascade plug For connecting a BMF400 input/output module
CAN Fieldbus DC 12 V; 6 W (module power supply);
RS232 Modem connection for fax, SMS and BMS with
Additional keys: Info, alarm query, freely programmable key
maintenance interval: 5 years
■ Project planning
■ Data
■ Time
Out of operation: 5% to 90% r.h., non-condensing
This device is intended for installation in a wall-mounted enclosure/switch
cabinet having protection class II.
Transistor outputs DC 24 V, max. 40 mA
Contact input (voltage-free)
DC 0 V to 10 V; max. 2.5 mA
BACnet® in accordance with DIN EN ISO
16484-5
2,000 m; 20 kBd
BACnet® in accordance with DIN EN ISO
16484-5
Page 3 / 10
A