Solar-powered room control module with LCD and controls, with intelligent communication management for measuring room temperature
and for wireless transmission of measured values, occupancy, setpoint
and weekly schedule.
For direct communication with the technoLink® MD15-FTL-315 wireless
small actuator, the RBW322-FTL-315 supports the non-proprietary
EnOcean wireless protocol A5-20-01 (Battery Powered Actuator) using
an integrated wireless interface.
Together with the MD15-FTL-315 function units, the RBW322-FTL-315
constitutes a functional unit for easy room temperature control.
The user manual of the RBW322-FTL-315 and the MD15-FTL-315 are
valid related closely. Follow the instructions and explanations in both
user manuals.
RBW322-FTL-315
ContentPage
General Information ...............................................................................................................................................2
Information about the Manual..............................................................................................................................2
Symbol Declaration..............................................................................................................................................3
Operation Elements and Display .........................................................................................................................7
Operations and Settings ........................................................................................................................................9
Maintenance and Cleaning ..................................................................................................................................14
System Malfunction .............................................................................................................................................15
Operating and Malfunctioning Messages ..........................................................................................................15
Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications -Reservado el derecho a modificación- Wijzigingen
voorbehouden - Con riserva di modifiche - Innehåll som skall ändras - Změny vyhrazeny - Zmiany zastrzeżone - Возможны изменения
A változtatások jogát fenntartjuk -
Kieback&Peter GmbH & Co. KG
Tempelhofer Weg 50, 12347 Berlin/Germany
Telefon: +49 30 60095-0, Telefax: +49 30 60095-164
www.kieback-peter.de, info@kieback-peter.com
保留未经通知而改动的权力
A
-
Datasheet 1.10-60.315-09-ENIssue 2012-08-16
User ManualRBW322-FTL-315
General Information
Information about the Manual
This manual contains information on the product RBW322-FTL-315 and its operation. Each person
who carries out work on this product must have read and understood this manual. If you have any
questions that are not resolved by this manual, you can obtain further information from your service
technician.
If the product is not used in accordance with this data sheet, the intended protection will be impaired.
Therefore, please observe the following items without fail:
► This manual is an integral part of the device. Please keep it in the immediate vicinity of the device.
► The manual must be retained throughout the entire service life of the device.
► The manual must be passed along to any subsequent owner or user.
NOTE
This manual describes the specific settings and functions of the RBW322-FTL-315. In addition to
these instructions, the product description of the MD15-FTL-315 wireless partner must also be
observed.
Copyright
Reproduction (including excerpts), recovery or transfer of any content without a written declaration of
the manufacturer is not allowed.
Notes on Disposal
The product is considered waste from electrical and electronic equipment (electronic waste) and may
not be disposed of as household waste. Special treatment for specific components may be legally
binding or ecologically sensible. The local and currently applicable legislation must be observed.
A
Page 2 / 22
Issue 2012-08-16
Symbol Declaration
Safety Instructions
Hazardous situations during installation, commissioning and operating the device are indicated by
safety instructions. They are indicated by signal words which express the severity of the hazard.
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Datasheet 1.10-60.315-09-EN
RBW322-FTL-315User Manual
DANGER!
WARNING
CAUTION
Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury.
NOTICE
Warns against a possible hazardous situation that could lead to property and environmental
damage.
Notes
Supplementary information can be found in the notes:
NOTE
Indicates additional information and important details that can simplify working with the product.
Enumeration Signs
There are two other signs which make this manual easier to use:
Page 3 / 22
■ Indicates a list point.
► Indicates an activity you have to do.
A
Datasheet 1.10-60.315-09-ENIssue 2012-08-16
User ManualRBW322-FTL-315
Safety
Safety Instructions
To minimize hazards to life and limb, the environment and the machine safety, please observe the
following items:
► Read all safety instructions in this manual in order to prevent injuries and damage to the device
or any equipment connected to it.
► To avoid potential hazards, only operate the product according to its intended use.
► Observe these notes as well as the safety instructions in the following sections of this manual.
Intended Use
Together with the MD15-FTL-315, the RBW322-FTL-315 constitutes a functional unit for easy room
temperature control.
Only the MD15-FTL-315 actuator is authorized for use.
Modifications to and retrofitting of the device could result in unforeseeable dangers and are thus
prohibited.
Please also observe the following items:
► Do not operate the device under wet or moist ambient conditions.
► Do not operate the device in a potentially explosive atmosphere.
► Keep the product surface clean and dry.
As an Operator, What May You Do?
You may only perform the following settings on the device:
■ Setting the setpoint. (See “Setting Setpoint” on page 9.)
■ Set the party mode. (See “Setting Party Mode (Usage Time Extension)” on page 10.)
■ Setting the vacation mode. (See “Setting Vacation Mode” on page 10.)
■ Setting the weekly schedule. (See “Setting the Weekly Schedule” on page 11.)
■ Delete usage time. (See “Delete usage time” on page 12.)
■ Setting the setpoints for comfort mode and reduced temperature mode. (See “Setting the Setpoints
for Comfort Mode and Reduced Temperature Mode” on page 12.)
■ Setting the time and date. (See “Setting the Time and Date” on page 13.)
■ Setting the 12/24 hour display. (See “Setting the 12/24 Hour Display” on page 13.)
■ Switching the temperature unit to °C/°F. (See “Switching the Temperature Units °C/°F” on
page 14.)
■ Maintenance and cleaning. (See “Maintenance and Cleaning” on page 14.)
■ Information about contacting customer service in case of operating and malfunction messages.
(See “Operating and Malfunctioning Messages” on page 15.)
NOTE
Mounting, installation, commissioning and troubleshooting may only be performed by a service
technician. Improper changes by the operator can lead to malfunction and impairment of the service
life.
Customer Service
For technical information or in the case of problems, please contact your service technician. You can
find the contact information on the back of the manual.
A
Page 4 / 22
Issue 2012-08-16
03
04
07
01
02
05
06
Equipment Description
Along with the MD15-FTL-315 units, the RBW322-FTL-315 constitutes a functional unit for room
temperature control. It is used for controlling the temperature in residential and commercial areas
(households, office buildings, hotels, school buildings under specific circumstances).
Before both wireless partners can communicate with each other, the MD15-FTL-315 must be
teached-in on the RBW322-FTL-315. This procedure only needs to be performed once. Generally,
both wireless partners can be automatically synchronized with each other after a connection failure,
e.g. as caused by malfunctions (See “System Malfunction” on page 15.).
Control of the RBW322-FTL-315/MD15-FTL-315 controller set is assumed by the RBW322-FTL-315.
Components
Datasheet 1.10-60.315-09-EN
RBW322-FTL-315User Manual
01DisplayDisplays information on the current status of controller
set RBW322/MD15.
02Rotary knobWhen switching on the device for the first time and to
select values.
03Solar cellGenerates energy for internal energy storage units
04Occupancy buttonSelect between “Present” and “Absent”
05Holding plateFastens the RBW322-FTL-315 operator panel
06BarFastens the RBW322-FTL-315 operator panel to the
holding plate
07Adhesive padBonds the holding plate to even surfaces
Page 5 / 22
A
Datasheet 1.10-60.315-09-ENIssue 2012-08-16
User ManualRBW322-FTL-315
Operating Modes
Because different rooms are used in different ways, temperature control based on use is more
energy-efficient. Rooms that are used in different ways need different temperature profiles.
In order to maintain a desired a temperature in a room, two different operating modes can be used:
Comfort Mode:Operating mode for a room that is in use (“present” mode). The controller
operates with the specified comfort setpoint. The room temperature remains
set in a comfortable range.
Reduced Temperature Mode:
Configurations
These operating modes are determined by following configurations, which can be set in the configuration level of the room control module:
Energy-saving operating mode (“absent”/economy mode) for a room that is
not in use. The controller operates with a reduced setpoint.
Weekly Schedule
MOFR:
Weekly Schedule
SASU:
Weekly Schedule
MOSU:
Party Mode:You can use the comfort mode longer than registered in the timetable for a
Vacation Mode:If you do not use the room for a longer period of time you can set the days in
The timetable with comfort mode or reduced temperature mode is set from
Monday to Friday.
The timetable with comfort mode or reduced temperature mode is set for
Saturday and Sunday
The timetable with comfort mode or reduced temperature mode is set from
Monday to Sunday
maximum of 8 hours after the comfort mode ends.
which you are not present. The room control module will use the reduced
temperature mode on these days.
A
Page 6 / 22
Issue 2012-08-16
1
2
3
Operation Elements and Display
The RBW322-FTL-315 and MD15-FTL-315 operate automatically. Basic settings are performed on
the RBW322-FTL-315 operator panel.
Datasheet 1.10-60.315-09-EN
RBW322-FTL-315User Manual
1[Rotary knob]
+
[Confirmation button]
2Occupancy button: Switch between “Present” (comfort mode) and
3DisplayDisplays the most current information of the room control module.
NOTE
If the occupancy button is switched to “absent” (reduced temperature mode) during an active usage
time, the reduced temperature mode is active until the next switching point (start time) for “comfort
mode”.
Turn: Set value (e.g. setpoint).
Turn counter-clockwise: Reduce value.
Turn clockwise: Increase value.
Press: Change levels or confirm display setting.
“Absent” (reduced temperature mode).