Kichler 300427 User Manual

 2*
TM
 2*
Leeds
A Kichler® Décor™ ceiling fan
Designed to coordinate with a popular Kichler Lighting collection.
Kichler® Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010
Customer Service
Includes our New Basic Function CoolTouch
Designed for use with Fluorescent Lighting
Looks Permanent, but goes wherever you go!
U.S. Patent Pending
TM
Control System
Instruction Manual
1
1. SAFETY RULES
1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.
2. All wiring must be in accordance with the National Electrical Code and local electrical codes. Electrical installation should be performed by a qualified licensed electrician.
3. WARNING: Suitable for use with solid­state speed controls.
4. WARNING: To reduce the risk of personal injury, use only the two steel screws (and lock washers) provided with the outlet box for mounting to the outlet box. Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced, consult a qualified electrician if in doubt.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR PERSONAL INJURY, MOUNT
FAN TO OUTLET BOX MARKED
"ACCEPTABLE FOR FAN SUPPORT".
5. The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 50 pounds. Use only CUL Listed outlet boxes marked "FOR FAN SUPPORT".
6. The fan must be mounted with a minimum of 7 feet clearance from the trailing edge of the blades to the floor.
10. Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable for most cleaning.
11. After making the electrical connections, spliced conductors should be turned upward and pushed carefully up into outlet box. The wires should be spread apart with the ground wire and white (common) wire to one side with the black (load) wire to the other side of the outlet box.
12. Electrical diagrams are reference only. Light kits that are not packed with the fan must be CUL Listed and marked suitable for use with the model fan you are installing. Switches must be CUL General Use Switches. Refer to the Instructions packaged with the light kits and switches for proper assembly.
WARNING
TO REDUCE THE RISK OF PERSONAL
INJURY, DO NOT BEND THE BLADE
BRACKETS (ALSO REFERRED TO AS
FLANGES) DURING ASSEMBLY OR AFTER
INSTALLATION. DO NOT INSERT OBJECTS
IN THE PATH OF THE BLADES.
Special Notice
This appliance is equipped with a "Wattage
Limiting Device" required by the United
States Department of Energy. The device
has been installed at the factory and can not
be removed.
7. Do not operate reversing switch while fan blades are in motion. Fan must be turned off and blades stopped before reversing blade direction.
8. Avoid placing objects in the path of the
blades.
9. To avoid personal injury or damage to the
fan and other items, be cautious when working around or cleaning the fan.
Installing Lamps in excess of 190 total watts
will disable the unit's light fixture. If this
should happen, you will need to reset the
lighting fixture by turning the power off to
the ceiling fan and/or light fixture,
reinstalling lamps totaling less that 190
watts and then turning the power back on.
2. TOOLS AND MATERIALS REQUIRED
Philips screw driver Blade screw driver 11 mm wrench Step ladder Wire cutters
3. PACKAGE CONTENTS
Leeds
TM
2
Unpack your fan and check the contents. You should have the following items:
a. Fan blades (5) b. Canopy & Ceiling mounting bracket c. Ball/downrod assembly d. Coupling cover e. Fan motor assembly f. Set of 5 blade brackets and Pre-Installed
mounting screws g. Light fixture h. Socket plate i. Glass shade j. 13W GU24 compact fluorescent lamps (2) k. CoolTouch™ Receiver l. Basic Function CoolTouch™ Control
System m. Part bag contents
1) Mounting hardware: wood screws (2), flat washers (2), star washers (2), wire nuts (3), screws (2)
2) Blade attachment hardware: screws (17), fiber washers (17)
3) Blade bracket attachment hardware: screws (2)
4) Safety cable hardware: wood screw, spring washer, flat washer
5) Balance Kit
b
a
c
j
k
d
l
e
m
f
g
h
i
3
4. MOUNTING OPTIONS
If there isn't an existing UL (cUL for Canadian Installation) listed mounting box, then read the following instructions. Disconnect the power by removing fuses or turning off circuit breakers.
Secure the outlet box directly to the building
Outlet box
Fig. 1
Outlet box
Fig. 2
structure. Use appropriate fasteners and building materials. The outlet box and its support must be able to fully support the moving weight of the fan (at least 50 lbs). Do not use plastic outlet boxes.
Figures 1, 2 and 3 are examples of different ways to mount the outlet box.
NOTE: If you are installing the ceiling fan on a sloped (vaulted) ceiling, you may need a longer downrod to maintain proper clearance between the tip of the blade and the ceiling. A minimum clearance of 12" is suggested for optimal operation.
ANGLED CEILING MAXIMUM 20° ANGLE
Recessed outlet box
Fig. 3
Outlet box
Fig. 4
Provide strong support
NOTE: Depending on the location you have selected for installation, you may need to purchase and install a "Joist Hanger" for the support of the outlet box. Make sure the joist hanger you purchase has been designed for use with ceiling fans. (Fig. 4)
Ceiling mounting plate
5. HANGING THE FAN
Leeds
TM
4
REMEMBER to turn off the power before you begin.
To properly install your ceiling fan, follow the steps below.
Step 1. Remove the decorative canopy bottom cover from the canopy by turning the cover counter clockwise. (Fig. 5)
Step 2. Remove the ceiling mounting bracket from the canopy by removing (and save) one of the two screws. Loosen the remaining screw by a half turn. (Fig. 5)
Step 3. Pass the 120 volt supply wires from the ceiling outlet box through the center of the ceiling mounting bracket. (Fig.6)
Step 4. Attach the ceiling mounting bracket to the outlet box using the screws and washers included with the outlet box. (Fig. 6)
UL Listed outlet box
Ceiling mounting bracket
Cross pin
Hook
Hanger ball
Fig. 5
120V Wires
Fig. 6
Ceiling mounting bracket
Canopy
Canopy cover
Washers
Mounting screws (supplied with electrical box)
Set screw
Step 5. Remove the hanger ball from the downrod assembly by loosening the set screw, removing the cross pin and sliding the ball off the rod. (Fig.7)
Step 6. Loosen the two set screws and remove the hitch pin and retaining clip from the coupling on top of the motor assembly. (Fig. 8)
Step 7. Carefully feed the electrical lead wires from the fan up through the downrod. Thread the downrod into the coupling until the Hitch pin holes are aligned.
Next, replace the hitch pin and retaining clip. Tighten both set screws. (Fig. 8)
Downrod
Fig. 7
Supply wires
Downrod
Coupling
Set screws
Hitch pin Retaining clip
Set screws
Fig. 8