KI WireWorks PWCT, WireWorks PW90, WireWorks PWCTW, WireWorks PWCTW90 Installation Manual

Countertop Installation Manual
WireWorks™ Countertops
Table of Contents
Model PWCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Straight Countertop
Model PW90 . . . . . . . . . . . . . . . . . . . . . . . . . .4
Model PWCTW . . . . . . . . . . . . . . . . . . . . . . . .6
Straight Wheelchair Height Countertop
Model PWCTW90 . . . . . . . . . . . . . . . . . . . . . .8
90˚ Wheelchair Height Countertop
1
Model PWCT Straight Countertop
2
Single piece rectangular surface. To be used with 36” or 42” high panels. Countertop extends no more than 4" over the top of the panel to comply with ADA guideline 4.4.1. Brackets, which are mounted on inside of station, include steel locking clips to prevent dislodgement. Countertop accepts task light on receptionist side.
Note: If countertop is installed adjacent to an in-
line height change full post, a notch must be specified on the left, right or both sides of the work surface. Figure 2.
Width: 24", 30", 36", 42", 48", 54", 60", 66", 72", 78", 84"
Depth: 16" Note: WireWorks Countertops can be installed
on top of any height panel. Countertops add 3" to the stated height of the panel; i.e. a 30" high panel supports a countertop such that the top of the countertop is 33" above the floor (assuming that the glides are turned out 1/2”).
Note: Brackets are positioned on the receptionist
side of the panel. The aisle side of the panel remains clear of brackets (except for wheelchair height countertops).
1. Ensure that countertop is the same width as the panel(s) to which it will be attached.
2. Ensure that the panel top cap and related trim is installed prior to attaching the countertop. Top cap cannot be installed after countertop is installed.
3. Position the brackets such that the top of the bracket is slightly (1/8") above the panel top cap. Note: Brackets are handed and "L" and "R" are stamped into the top flange of the brackets.
Figure 1.
Countertop support lock (L)
Countertop support bracket (L)
Countertop support bracket (R)
Countertop support lock (R)
Figure 1
Panel
Lock
Bracket
Aisle
Receptionist
Model PWCT Straight Countertop
3
4. Brackets are engaged into the panel by inserting teeth of bracket into slots of vertical post and then pushing down to seat. Check for proper engagement by pulling firmly straight out.
Note: Countertops over 60" use three brackets.
5. Locate predrilled holes on underside of countertop.
6. Place countertop over brackets (installed on panel). Position countertop such that greatest amount of overhang is on receptionist side of panel. Figure 1.
7. Install one screw in the left and right brackets in holes closest to receptionist.
8. Insert locking bracket so that the long finger of the bracket engages into slot of vertical post of panel and that the hole in the top flange of locking bracket aligns with the hole in the countertop bracket (closest to the panel).
Figure 1.
9. Drive in screw through flanges of both brackets and into pilot hole of countertop.
10. Tighten all four screws.
Countertop used with change of height trim
When the countertop is located next to a taller panel(s) the countertop must be ordered with one or two notches to accommodate the end of run trim of the taller panel(s). Figure 2.
Note: To finish the cutout in the countertop, use
the C-shaped grommet. A filler is provided to cap the grommet if the countertop is reconfigured to a location without a taller adjacent panel.
C-shaped grommet
Filler
Notch
Figure 2
Aisle
Receptionist
Loading...