Keysight Technologies U5855A, U5856A, U5857A User Manual

Keysight U5850 Series TrueIR Thermal Imager
User’s Guide
Distribution in the UK & Ireland
Lambda Photometrics Limited
Lambda House Batford Mill Harpenden Herts AL5 5BZ United Kingdom
E: info@lambdaphoto.co.uk W: www.lambdaphoto.co.uk T: +44 (0)1582 764334
F: +44 (0)1582 712084
2 Keysight U5850 Series User’s Guide
Notices
Copyright Notice
© Keysight Technologies 2014–2016 No part of this manual may be repro-
duced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Keysight Technol­ogies as governed by United States and international copyright laws.
Manual Part Number
U5857-90000
Edition
Edition 4, September 9, 2016
Printed in:
Printed in Malaysia
Published by:
Keysight Technologies Bayan Lepas Free Industrial Zone, 11900 Penang, Malaysia
Technology Licenses
The hardware and/or software described in this document are fur­nished under a license and may be used or copied only in accordance with the terms of such license.
Declaration of Conformity
Declarations of Conformity for this product and for other Keysight prod­ucts may be downloaded from the Web. Go to http://www.keysight.com/
go/conformity. You can then search by
product number to find the latest Dec­laration of Conformity.
U.S. Government Rights
The Software is “commercial computer software,” as defined by Federal Acqui­sition Regulation (“FAR”) 2.101. Pursu­ant to FAR 12.212 and 27.405-3 and Department of Defense FAR Supple­ment (“DFARS”) 227.7202, the U.S. government acquires commercial com­puter software under the same terms by which the software is customarily provided to the public. Accordingly, Keysight provides the Software to U.S. government customers under its stan­dard commercial license, which is embodied in its End User License Agreement (EULA), a copy of which can be found at http://www.keysight.com/
find/sweula. The license set forth in the
EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Soft­ware. The EULA and the license set forth therein, does not require or per­mit, among other things, that Keysight: (1) Furnish technical information related to commercial computer soft­ware or commercial computer software documentation that is not customarily provided to the public; or (2) Relinquish to, or otherwise provide, the govern­ment rights in excess of these rights customarily provided to the public to use, modify, reprod uce, release, per­form, display, or disclose commercial computer software or commercial com­puter software documentation. No additional government requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial computer software pursu­ant to the FAR and the DFARS and are set forth specifically in writing else­where in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR
12.211 and 27.404.2 and DFARS
227.7102, the U.S. government acquires no greater than Limited Rights as defined in FAR 27.401 or DFAR
227.7103-5 (c), as applicable in any technical data.
Warranty
THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED “AS IS,” AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DIS­CLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, WITH REGARD TO THIS MANUAL AND ANY INFORMA­TION CONTAINED HEREIN, INCLUD­ING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MER­CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSE­QUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCUMENT OR OF ANY INFORMATION CON­TAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WAR­RANTY TERMS COVERING THE MATE­RIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT SHALL CONTROL.
Safety Information
CAUTION
A CAUTION notice denotes a hazard. It calls attention to an operating proce­dure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not pro­ceed beyond a CAUTION notice until the indicated conditions are fully understood and met.
WARNING
A WARNING notice denotes a hazard. It calls attention to an operating proce­dure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.
Keysight U5850 Series User’s Guide 3
Safety Symbols
The following symbols on the instrument and in the documentation indicate precautions which must be taken to maintain safe operation of the instrument.
Caution, risk of danger (refer to this manual for specific Warning or Caution information)
Laser radiation
4 Keysight U5850 Series User’s Guide
Safety Considerations
Read the information below before using this instrument.
The following general safety precautions must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards for design, manufacture, and intended use of the instrument. Keysight Technologies assumes no liability for the customer’s failure to comply with these requirements.
WARNING
– Do not use the U5850 Series if it is damaged. Before you use the U5850
Series, inspect the casing. Look for cracks or missing plastic. Do not operate the U5850 Series around explosive gas, vapor, or dust.
– Always use the U5850 Series with the cables provided.
– Observe all markings on the U5850 Series before establishing any
connection.
– Turn off the U5850 Series before removing the battery cover.
– When servicing the U5850 Series, use only the specified replacement
parts.
– Do not operate the U5850 Series with the battery cover or portions of the
cover removed or loosened.
– Use only the designated AC/DC power adapter or charger provided by the
manufacturer to avoid any unexpected hazards.
– Use only the battery pack supplied with the U5850 Series. Do not
disassemble/modify the battery pack or leave it under direct heat/ sunlight.
– Keep the battery pack away from water, fire, or heat.
– Avoid any contact with battery leakage to prevent personal injuries. If
there is leakage or strange smell, remove the battery pack immediately from the U5850 Series or the external battery charger.
Keysight U5850 Series User’s Guide 5
WARNING
– Do not connect the positive terminal and the negative terminal of the
battery pack (metallic part) to each other with any metal objects, such as wires.
– Do not continue to charge the battery pack if it does not become charged
within the specified charging time.
– Do not apply impact to or insert foreign objects into the battery pack.
– Do not use the camera on a tripod in an area with large vibration or shock.
– Do not use the U5850 Series under water or with conductive gloves or
cloths worn or in a strong electromagnetic field.
– Do not stare into the torch light.
CAUTION
– Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
– The U5850 Series uses a highly-sensitive infrared detector. Ensure to
comply with the requirements in “Environmental Conditions” on page 8 when using the U5850 Series.
– Do not apply excessive stress to the LCD screen, the focus adjustment
ring, or the camera lens to avoid damages.
– Avoid direct rays or shock to the visible or infrared camera lens of the
U5850 Series.
– Do not perform image acquisition directly at the sun or objects with
extremely high temperature over a long period of time to avoid damage to the infrared detector.
6 Keysight U5850 Series User’s Guide
CAUTION
– The following condition may be observed when the U5850 Series
acquires or saves a visible image. This condition is not a device failure.
– The color of the visible image changes periodically or may be different
from the real target object when the image is replayed in the freeze mode.
To avoid this condition, perform image acquisitions by changing the camera angle. In this case, it is recommended to acquire visible images by observing the image on the screen.
– The following condition may be observed in outdoor data acquisitions.
This condition is not a device failure.
– If the contrast is great (e.g., due to backlight), the object may appear
darker on the camera display as compared to the brightness of the background.
To avoid this condition, control the frame so that it covers only the target object.
– If bright sunlight enters the visible camera, the entire picture may
become reddish. To avoid this, shield the camera from bright sunlight.
– When the U5850 Series is moved from objects with large temperature
differences, “ghost” image may be present on the display. This condition is not a device failure. It may take several minutes to dissipate the “ghost” image. You can automatically dissipate the “ghost” image by switching to the freeze mode and back to the run mode (refer to “Image Playback” on page 56).
Do not input laser beam (CO
2
laser, etc.) to avoid damage to the infrared
detector.
– If the U5850 Series is used in a manner not specified by the manufacturer,
the U5850 Series protection may be impaired.
– Always use a dry cloth to clean the U5850 Series. Do not use ethyl
alcohol or any other volatile liquid to clean the U5850 Series.
Keysight U5850 Series User’s Guide 7
WARNING
Laser pointer precautions:
– This laser pointer is a Class 2 laser product.
– Laser beam contact with the eyes may cause visual impairment.
– Do not point the laser beam towards people.
– Do not stare into the laser beam.
– The U5850 Series is intended for professional use and is not suitable for
general use.
Video
DC 12V
RAYONNEMENT LASER
PRODUIT LASER DE CLASSE 2
LONGUEUR D'ONDE :655nm
PUISSANCE DE SORTIE MAXI :1mW
NE PAS REGARDER LE FAISCEAU
IEC60825-1/2007
U5857A
Laser beam
Laser control key
8 Keysight U5850 Series User’s Guide
Environmental Conditions
The U5850 Series TrueIR Thermal Imager is designed for indoor use and in an area with low condensation. The table below shows the general environmental requirements for this instrument.
Regulatory Information
The U5850 Series TrueIR Thermal Imager complies with the following safety and Electromagnetic Compatibility (EMC) compliances:
Safety compliance
– Laser safety: IEC 60825-1/EN 60825-1 (Laser Class 2)
– IEC 61010-1/EN 61010-1
EMC compliance
– IEC 61326-1/EN61326-1
– CISPR11/EN55011, Group 1 Class A
– Canada: ICES/NMB-001: Issue 4, June 2006
– Australia/New Zealand: AS/NZS CISPR 11
Environmental condition Requirement
Temperature
Operating condition – –15 °C to 50 °C Storage condition – –40 °C to 70 °C
Humidity
Operating condition – 50% RH to 95% RH at 40 °C Storage condition – 95% RH at 40 °C
Altitude Up to 2000 m
Pollution degree 2
Keysight U5850 Series User’s Guide 9
Regulatory Markings
The CE marking is a legal compliance marking of the European Community. This CE marking shows that the product complies with all the relevant European Legal Directives.
The RCM mark is a registered trademark of the Spectrum Management Agency of Australia. This signifies compliance with the Australia EMC Framework regulations under the terms of the Radio Communication Act of 1992.
ICES/NMB-001 indicates that this ISM device complies with the Canadian ICES-001.
Cet appareil ISM est conforme a la norme NMB-001 du Canada.
This instrument complies with the WEEE Directive (2002/96/EC) marking requirement. This affixed product label indicates that you must not discard this electrical or electronic product in domestic household waste.
This symbol is a South Korean Class A EMC Declaration. This is a Class A instrument suitable for professional use and in electromagnetic environment outside of the home.
This symbol indicates the time period during which no hazardous or toxic substance elements are expected to leak or deteriorate during normal use. Forty years is the expected useful life of the product.
MSIP-REM-
ATi-THERMAL
10 Keysight U5850 Series User’s Guide
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/ 96/EC
This instrument complies with the WEEE Directive (2002/96/EC) marking requirement. This affixed product label indicates that you must not discard this electrical or electronic product in domestic household waste.
Product category:
With reference to the equipment types in the WEEE directive Annex 1, this instrument is classified as a “Monitoring and Control Instrument” product.
The affixed product label is as shown below.
Do not dispose in domestic household waste.
To return this unwanted instrument, contact your nearest Keysight Service Center, or visit http://about.keysight.com/en/companyinfo/environment/takeback.shtml for more information.
Sales and Technical Support
To contact Keysight for sales and technical support, refer to the support links on the following Keysight websites:
www.keysight.com/find/trueIRimager
(product-specific information and support, software and documentation updates)
www.keysight.com/find/assist
(worldwide contact information for repair and service)
Keysight U5850 Series User’s Guide 11
Table of Contents
Safety Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Safety Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Regulatory Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Safety compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
EMC compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Regulatory Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/
EC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Product category: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Sales and Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
1Introduction
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Documentation map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Safety notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Preparing the U5850 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Check the shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Standard shipped items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Install the hand strap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Install and charge the battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Insert the SD memory card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Turn on the U5850 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Set up the U5850 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
The U5850 Series in Brief . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
LED status indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Camera mode switching flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Display screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
2 Image Capture, Processing, and Measurement Functions
Camera Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
12 Keysight U5850 Series User’s Guide
Capture images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Image Saving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Preview and save an image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Add tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Edit tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Delete tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Save an image directly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Edit an image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Image Playback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Full screen/Thumbnail playback mode operation . . . . . . . . . . . . . . 56
Full screen playback mode overview . . . . . . . . . . . . . . . . . . . . . . . . 57
Thumbnail playback mode operation . . . . . . . . . . . . . . . . . . . . . . . . 58
Thumbnail playback mode overview . . . . . . . . . . . . . . . . . . . . . . . . . 59
Delete an image (full screen playback mode) . . . . . . . . . . . . . . . . . 60
Delete multiple images (thumbnail playback mode) . . . . . . . . . . . . 61
Measurement Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Set the temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Set the center spot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Set the max/min tracking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Set the moveable spots and boxes . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Set the delta temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Turn off all measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Imaging Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Set the color palette . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Load a custom color palette . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Set the color alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Digital Zoom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Set the zoom ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Pan (move) the zoom area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Disable zoom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Parameter Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Set the emissivity (ε) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Set the reflected temperature (RT) . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Set the object distance (OD), ambient temperature (AT), and
Keysight U5850 Series User’s Guide 13
humidity (Hum) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
Set the transmissivity (τ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94
3 Data Management and System-Related Functions
Data Management Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96
Perform image logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96
View the memory status of the SD memory card . . . . . . . . . . . . . .101
Manage image folders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102
Format the SD memory card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106
System-Related Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107
Configure the Quick Start Tutorial . . . . . . . . . . . . . . . . . . . . . . . . .107
Save/recall instrument setups . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110
Turn on/off visible image auto-save . . . . . . . . . . . . . . . . . . . . . . . .111
Configure the display items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112
Configure the main key press functions . . . . . . . . . . . . . . . . . . . . .114
Set the USB mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Set the power saving mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Set the LCD brightness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119
Set the temperature unit (°C or °F) . . . . . . . . . . . . . . . . . . . . . . . . .119
Set the date and time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119
Set the video out format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120
Set the language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120
Display the system and owner information . . . . . . . . . . . . . . . . . . .121
Reset the U5850 Series to factory default settings . . . . . . . . . . . .124
4 Characteristics and Specifications
14 Keysight U5850 Series User’s Guide
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
Keysight U5850 Series User’s Guide 15
List of Figures
Figure 1-1 The front and side panels at a glance . . . . . . . . . . . . .32
Figure 1-2 The rear panel at a glance . . . . . . . . . . . . . . . . . . . . . .33
Figure 1-3 The display at a glance . . . . . . . . . . . . . . . . . . . . . . . . 36
16 Keysight U5850 Series User’s Guide
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
Keysight U5850 Series User’s Guide 17
List of Tables
Table 1-1 Rear panel descriptions . . . . . . . . . . . . . . . . . . . . . . . .33
Table 1-2 LED status indication (power adapter connected) . . . 34
Table 1-3 Display descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Table 1-4 Battery status indication . . . . . . . . . . . . . . . . . . . . . . .37
Table 2-1 Emissivity table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
18 Keysight U5850 Series User’s Guide
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
Keysight U5850 Series TrueIR Thermal Imager User’s Guide
19
1 Introduction
About This Manual 20
Preparing the U5850 Series 21
The U5850 Series in Brief 32
This chapter guides you to set up the U5850 Series TrueIR Thermal Imager for the first time. A summary of all the U5850 Series TrueIR Thermal Imager features is also given.
1Introduction
20 Keysight U5850 Series User’s Guide
About This Manual
The descriptions and instructions in this manual apply to the Keysight U5855A, U5856A, and U5857A TrueIR Thermal Imager (hereafter referred to as the U5850 Series or the instrument).
The model U5857A appears in all illustrations.
Documentation map
The following manuals and software are available for your instrument. For the latest version, visit our website at: www.keysight.com/find/trueIRimager
Check the manual revision on the first page of each manual.
User’s Guide
This manual.
Quick Start Guide
Printed copy, included with shipment.
Service Guide
Free download at the Keysight website.
Keysight TrueIR Analysis and Reporting Tool software
Free download at the Keysight website: www.keysight.com/find/trueIR_ART
Safety notes
Safety notes are used throughout this manual (refer to the Safety Symbols section for format examples). Familiarize yourself with each of the notes and its meaning before operating your instrument.
More pertinent safety notes for using this instrument are located under the Safety
Considerations section.
Do not proceed beyond a safety notice until the indicated conditions are fully understood and met.
Introduction 1
Keysight U5850 Series User’s Guide 21
Preparing the U5850 Series
Check the shipment
When you receive your instrument, check the shipment according to the following procedure.
1 Inspect the shipping container for damage. Signs of damage may include a
dented or torn shipping container or cushioning material that indicates signs
of unusual stress or compacting. Save the packaging material in case the
instrument needs to be returned.
2 Carefully remove the contents from the shipping container, and verify that the
standard items are included in the shipment according to the standard shipped
items list shown in “Standard shipped items” on page 22.
3 For any enquiries, refer to the Keysight contact numbers on the back of this
manual.
If any item is found missing or damaged, contact your nearest Keysight Sales Office.
Keep the original packaging in case the U5850 Series has to be returned to Keysight in the future. If you return the U5850 Series for service, attach a tag identifying the owner and model number. Include also a brief description of the problem.
1Introduction
22 Keysight U5850 Series User’s Guide
Standard shipped items
Keysight U5850 Series TrueIR Thermal Imager
Quick Start Guide
Keysight U5850 Series TrueIR Thermal Imager
Hard carrying case Power adapter Power cord Li-Ion rechargeable
battery
SD memory card
USB Standard-A to Mini
Type-B interface cable, 2 m
Video RCA to RCA
interface cable, 2 m
Keysight U5850 Series
Quick Start Guide
Certificate of
Calibration
Certificate of
Calibration
Introduction 1
Keysight U5850 Series User’s Guide 23
Install the hand strap
Video
DC 12V
1Introduction
24 Keysight U5850 Series User’s Guide
Install and charge the battery
NOTE
It is recommended to store the battery in a cool, dry place at normal room temperature. Remove the battery from the device if the device is stored for extended periods.
Video
DC 12V
Press to lock firmly in place.
1
Introduction 1
Keysight U5850 Series User’s Guide 25
Allow at least 4 hours for the battery to fully charge.
2
Indicates charging status
2a
NOTE
Refer to “LED status indication” on page 34 and “Battery status indication” on page 37 for more details.
1Introduction
26 Keysight U5850 Series User’s Guide
Insert the SD memory card
Turn on the U5850 Series
CAUTION
DO NOT REMOVE the battery or the SD memory card before power is turned off and the LED light goes off entirely. Otherwise it may damage the U5850 Series or destroy files saved in the SD memory card.
Introduction 1
Keysight U5850 Series User’s Guide 27
Set up the U5850 Series
Press for 1 seconds to turn on/off.
1
When you turn on the U5850 Series for the first time or after a factory reset, you will be prompted to perform initial setups. Refer to
“Set up the U5850 Series” on page 27.
2
Quick start tutorial:
3
To navigate the tutorial pages:
To exit:
OR
4
5
Ready to take measurements with specified accuracy after warm-up.
6
NOTE
– If Auto Off is enabled, the U5850 Series will automatically turns off if idle for
20 minutes (default). Pressing the power key will turn it back on.
– If Auto Sleep is enabled, the U5850 Series will automatically goes to sleep if
idle for 10 minutes (default). Pressing any key will turn it back on.
– Refer to “Set the USB mode” on page 115 for more details.
1Introduction
28 Keysight U5850 Series User’s Guide
Set the language
NOTE
This is only applicable when you turn on the U5850 Series for the first time, or after restoring the factory settings.
Introduction 1
Keysight U5850 Series User’s Guide 29
Set the date, time, and temperature unit
1
2
3
1Introduction
30 Keysight U5850 Series User’s Guide
Push left/right to move the indicator.
Push up/down to increase/decrease the digits.
–Year: 00 to 99 (00: year 2000) – Month: 01 to 12 – Date: 01 to 31
4
5
–Hour: 00 to 23 – Minute: 00 to 59 – Second: 00 to 59
Push left/right to move the indicator.
Push up/down to increase/decrease the digits.
6
Loading...
+ 97 hidden pages