Keysight U1701B Dual
Display Handheld
Capacitance Meter
Quick Start
Guide

ENGLISH
Contacting Keysight
www.keysight.com/find/assist
(worldwide contact information for
repair and service)
Safety and EMC Information
The Keysight U1701B is
safety-certified in compliance with
the following safety and EMC
requirements:
– IEC 61010-1:2001/EN
61010-1:2001 (2nd Edition)
– CISPR 11:2003+A1:2004
– IEC 61000-4-2:1995+
A1:1998 +A2:2000
– IEC 61000-4-3:2006
– IEC 61000-4-4:2004
– IEC 61000-4-5:2005
– IEC 61000-4-6:2003+
A1:2004+A2:2006
A WARNING notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly
performed or adhered to, could
result in personal injury or
death. Do not proceed beyond a
WARNING notice until the
indicated conditions are fully
understood and met.
Safety symbols
Earth (ground) terminal
Equipment protected
throughout by double
insulation or reinforced
insulation
– IEC 61000-4-11:2004
– Canada: ICES-001:2004
– Australia/New Zealand:
AS/NZS CISPR11:2004
Safety Notices
A CAUTION notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly
performed or adhered to, could
result in damage to the product or
loss of important data. Do not
proceed beyond a CAUTION notice
until the indicated conditions are
fully understood and met.
Caution, risk of electric
shock
Caution, risk of danger
(refer to this manual for
specific Warning or Caution
information)
For further safety information details, refer to the
Keysight U1701B Dual Display Handheld Capacitance Meter User’s Guide.
2 Keysight U1701B Quick Start Guide

The following items are included with your
capacitance meter:
✔ Alligator clip leads
✔ Printed Quick Start Guide
ENGLISH
✔ 9 V Alkaline battery
✔ Certificate of Calibration
If anything is missing or damaged, please contact
the nearest Keysight Sales Office.
For more detailed information, please refer to the
Keysight U1701B Dual Display Handheld
Capacitance Meter User’s Guide on Keysight Web
site (www.keysight.com/find/handheld-tools).
To avoid damage to the device, do not exceed the input
limit. Do not apply voltage to input terminals.
Discharge the capacitor before testing.
Keysight U1701B Quick Start Guide 3

ENGLISH
Capacitance Measurement
Procedure:
1 Press to power-on the meter.
2 To test for capacitance, keep an open circuit on
the test leads and press to subtract the
residual capacitance of the meter and leads.
3 Insert the capacitor legs into + and – input
terminals respectively. Ensure that the polarity
of the capacitor’s leg are correct.
4 Remove your hands from capacitor to allow it
to be tested.
5 Read the measurement on the display.
To avoid possible damage to the meter or the
equipment under test, disconnect circuit power and
discharge the capacitor before measuring
capacitance.
4 Keysight U1701B Quick Start Guide