A WARNING notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly
performed or adhered to, could
result in personal injury or
death. Do not proceed beyond a
WARNING notice until the
indicated conditions are fully
understood and met.
Safety symbols
Earth (ground) terminal
Equipment protected
throughout by double
insulation or reinforced
insulation
A CAUTION notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly
performed or adhered to, could
result in damage to the product or
loss of important data. Do not
proceed beyond a CAUTION notice
until the indicated conditions are
fully understood and met.
Caution, risk of electric
shock
Caution, risk of danger
(refer to this manual for
specific Warning or Caution
information)
For further safety information details, refer to the
Keysight U1701B Dual Display Handheld Capacitance Meter User’s Guide.
2Keysight U1701B Quick Start Guide
Page 3
The following items are included with your
WARNING
capacitance meter:
✔Alligator clip leads
✔Printed Quick Start Guide
ENGLISH
✔9 V Alkaline battery
✔Certificate of Calibration
If anything is missing or damaged, please contact
the nearest Keysight Sales Office.
For more detailed information, please refer to the
Keysight U1701B Dual Display Handheld
Capacitance Meter User’s Guide on Keysight Web
site (www.keysight.com/find/handheld-tools).
To avoid damage to the device, do not exceed the input
limit. Do not apply voltage to input terminals.
Discharge the capacitor before testing.
Keysight U1701B Quick Start Guide3
Page 4
ENGLISH
CAUTION
Capacitance Measurement
Procedure:
1Press to power-on the meter.
2To test for capacitance, keep an open circuit on
the test leads and pressto subtract the
residual capacitance of the meter and leads.
3Insert the capacitor legs into + and – input
terminals respectively. Ensure that the polarity
of the capacitor’s leg are correct.
4Remove your hands from capacitor to allow it
to be tested.
5Read the measurement on the display.
To avoid possible damage to the meter or the
equipment under test, disconnect circuit power and
discharge the capacitor before measuring
capacitance.
4Keysight U1701B Quick Start Guide
Page 5
Features and Functions
8
5
4
1
2
3
9
7
6
ENGLISH
No.KeysFunctions
1PowerTo turn ON/OFF the instrument
2SETSet high/low limits for compare mode
3RECStatic recording mode
4Compare mode
5TOLTolerance mode
6RELRelative mode
7HOLD
SAVE
Data hold
To store the setting value into the memory
8RANGE
AUTO
Manual range
Auto range
9HI/LOHigh/Low limits
Backlight display
Keysight U1701B Quick Start Guide5
Page 6
ENGLISH
How to Enter Setup Mode
Press and hold and power on the
instrument from OFF status.
Release when you hear a beep, the
instrument will then enter setup mode. These
parameters will be remained in the non-volatile
memory even after the instrument is turned off.
To configure the related parameters on setup
mode, ensure that the following procedures are
followed:
1Press (Left) or (Right) to select the
menu item to be set.
2Press (Up) or (Down) to change the
parameter.
3Press to select the digit to be adjusted,
the selected digit will flash.
4Press and hold for more than 1 s to
save your setting.
5Press for more than 1 s to exit setup
mode.
6Keysight U1701B Quick Start Guide
Page 7
Features and Functions
ActionsSteps
ENGLISH
To power ON or OFF
To enable data hold function
To trigger holding next reading
To exit data hold mode
To enable recording function
– The beeper will beep when a new MAX or MIN
value has been recorded.
– The static recording captures stable values and
updates the memory. It will not record values that
are overloaded, OL or below 10 count value.
Press
Press
Press
momentarily
Press for more
than 1 s
Press
To cycle through maximum, minimum, average, and
present readings
– MAX, MIN, AVG or MAX AVG MIN annunciator will
be turned on respectively to indicate which value
is being displayed
To exit the recording mode
Press
momentarily
Press for
more than 1 s
Keysight U1701B Quick Start Guide7
Page 8
ENGLISH
ActionsSteps
To enable relative function
– Relative function shows the difference between
the measured value and the offset reference value.
The display may show a non-zero value due to the
presence of test leads. Use the relative function to
nullify the residual.
– Relative function can operate in both auto and
manual ranging mode but the function cannot be
set when an overload value exists.
– REL annuciator will be displayed.
To renew the relative value
To exit relative mode
To select manual range and to turn off the AUTO
annunciator
Press
Press again
Press for
more than 1 s
Press
To step up a range at a time
To select auto-range
– In auto range mode, the AUTO annunciator is
displayed and the instrument will select an
appropriate range for resolution if the reading is
greater than the maximum available range. OL will
be displayed.
– The instrument will select a lower range when the
reading is less than 9% of full scale.
To enable the tolerance mode and to set the display
value as a standard reference
– TOL annunciator will be displayed.
– The tolerance will be displayed on the secondary
display.
– The instrument range will be locked.
To exit tolerance mode
Press again
Press for
more than 1 s
Press
Press and
8Keysight U1701B Quick Start Guide
hold for more than 1 s
Page 9
ActionsSteps
ENGLISH
To cycle through 1%, 5%, 10% and 20% tolerance
– will be indicated.
– Beeper will beep once if the test value is within the
selected tolerance. If the test value is out of the
tolerance, the beeper will beep three times.
– This mode cannot be enabled under the following
conditions:
– After setting the recording mode
– After setting the compare mode
– Display showing either OL or below 10 counts
To enable compare mode
– Measuring range will be locked
– will be displayed and the secondary display
will indicate C # #, meaning which set has been
used for compare mode. The two right digits
indicate current compare set. The # # range from
01 to 25.
Press
momentarily
Press
– The primary display shows the present
measurement. In this state, it is ready for testing.
– If the reading is beyond the high limit, will be
indicated. will be indicated if the reading is
out of the low limit. The beeper will beep three
times and the secondary display will indicate nGo.
– If the reading is within the high and low limits, the
beeper will beep once, and the secondary display
will indicate Go. After three seconds or when the
reading is lower than 10 counts, the instrument
will return to its ready state.
– The secondary display will indicate C01 to C25
according to the comparison record that has been
selected.
To save comparison set for next entry
Press and
hold for more than 1 s
Keysight U1701B Quick Start Guide9
Page 10
ENGLISH
ActionsSteps
To exit compare mode
To view the High/Low limit value to be used as
compare mode
To cycle through HI limit, LO limit, and present values
on the primary display
– The secondary display showed as H # #, L # # and
C # # respectively.
– After three seconds without pressing this button
again, it will return to the present value display.
To toggle HI and LO limits for adjustment
To enter HI/LO limits setting mode
– The secondary display will flash H01 and the
primary display will indicate the value of HI limit.
– The following buttons will be used for this setting
mode:
Press
Press
momentarily
Press
Press
momentarily
Press for
more than 1 s
– To select which digit to be adjusted
– To increase or decrease the current digit’s
value
– To select High or Low limit to be set.
– To store the setting value in the memory. The
beeper will beep twice if the selected value has
been stored. If the current setting do not meet
the rule that the high limit must be equal or
greater than the low limit, the beeper will beep
three times.
– To select next compare setting. To cycle
through L01 (or H01) to L25 (or H25), then
return to L01 (H01) setting.
Press (Left) or
(Right)
Press (Up) or
(Down)
Press
Press for
more than 1 s
Press
momentarily
10Keysight U1701B Quick Start Guide
Page 11
ActionsSteps
CAUTION
ENGLISH
To exit the HI/LO limit setting mode
To toggle backlight ON/OFF
Backlight turns off automatically after setting period
by setup mode.
Degradation of some product specifications can
occur in the presence of ambient electromagnetic
(EM) fields and noise that affects the product’s
power line or I/O cables. The product self-recovers
and operates to all specifications when:
–the source of the ambient EM field and noise is
removed,
–the product is protected from the ambient EM
field, or
Press for
more than 1 s
Press and
hold for more than 1 s
–the product cabling is shielded from the
ambient EM noise.
Keysight U1701B Quick Start Guide11
Page 12
ENGLISH
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
12Keysight U1701B Quick Start Guide
Page 13
This information is subject to change
without notice. Always refer to the
Keysight website for the latest revision.