Keysight Technologies N9000B Configuration Manual

Keysight Technologies
CXA X-Series Signal Analyzer, Multi-touch N9000B
Configuration Guide
This conguration guide will help you determine which performance options, measurement applications, accessories, and services to include with your new multi-touch CXA or to add as upgrades to
an existing CXA.
02 | Keysight | N9000B CXA X-Series Signal Analyzer, Multi-touch - Configuration Guide
Congure Your Keysight CXA Signal Analyzer
This step-by-step process will help you congure your new CXA X-Series signal analyzer. Tailor the performance to meet your requirements.
Included in base product
Standard options and accessories come with the CXA base model at no additional charge and do not need to be ordered. They include:
Spectrum analyzer measurement applicationDual-core, high-performance processor, 8 GB RAM, removable solid-state driveFrequency reference10 MHz analysis bandwidthEnhanced phase noiseWindows Embedded Standard 7Benchtop conguration – Mouse – User guide – Power cord3-year return-to-Keysight warranty
Step 1. Select maximum frequency range (required option; frequency range not upgradeable)
Description Option number Additional information
Frequency range, 9 kHz to 3.0 GHz N9000B-503 Frequency range, 9 kHz to 7.5 GHz N9000B-507 Frequency range, 9 kHz to 13.6 GHz N9000B-513 Frequency range, 9 kHz to 26.5 GHz N9000B-526
Get More Information
For a summary of specications,
refer to the N9000B CXA data
sheet (literature number 5992­1274EN ).
A full set of specications are available in the N9000B CX A Signal Analyzer Specication
Guide at www.keysight.com/nd/ cxa_specications.
Step 2. Add a preamplier
Description Option number Additional information: Preampliers improve the noise oor for low-level signal
detection; +20 dB: 100 kHz to 26.5 GHz
Preamplier, 100 kHz to 3.0 GHz N9000B-P03 Compatible with N9000B-503, N9000B-507, N9000B-513,
and N9000B-526
Preamplier, 100 kHz to 7.5 GHz N9000B-P07 Compatible with N9000B-507, N9000B-513, and N9000B-526 Preamplier, 100 kHz to 13.6 GHz N9000B-P13 Compatible with N9000B-513 and N9000B-526 Preamplier, 100 kHz to 26.5 GHz N9000B-P26 Compatible with N9000B-526
Step 3. Choose frequency reference
Description Option number Additional information
Frequency reference Standard Aging rate: ± 1 x 10–6/year Precision frequency reference N9000B-PFR Reduces frequency drift for more accurate measurements; aging rate: ± 1 x 10–7 /year
Step 4. Choose an attenuator
Description Option number Additional information
Mechanical attenuator Standard 10 dB steps, 0 to 50 dB, for N9000B-503 and N9000B-507
10 dB steps, 0 to 70 dB, for N9000B-513 and N9000B-526
Fine resolution step attenuator N9000B-FSA Allows 2 dB steps for the full range of the attenuator
Step 5. Choose analysis bandwidth
Description Option number Additional information
10 MHz analysis bandwidth Standard Useful for most 2G and 3G measurement applications 25 MHz analysis bandwidth N9000B-B25 Extends the analysis (demod) bandwidth from 10 to 25 MHz; useful for most cellular
communications, wireless connectivity, and audio/video broadcasting measurement applications
03 | Keysight | N9000B CXA X-Series Signal Analyzer, Multi-touch - Configuration Guide
Congure Your Keysight CXA Signal Analyzer (Continued)
Step 6. Add a tracking generator
Description Option number Additional information
Tracking generator, 9 kHz to 3.0 GHz N9000B-T03 Compatible with N9000B-503, N9000B-507 only Tracking generator, 9 kHz to 6.0 GHz N9000B-T06 Compatible with N9000B-507 only
Step 7. Add a 75 Ω input connector
Description Option number Additional information
Connector, 75 Ω additional RF input,
1.5 GHz
Step 8. Choose performance
Description Option number Additional information
Enhanced phase noise Standard Installed as N9000B-EP4
Step 9. Add optional features
Description Option number Additional information
Enhanced display package N9000B-EDP Includes spectrogram, trace zoom, and zone span Basic precompliance EMI N9000B-EMC Perform EMI precompliance measurements with CISPR 16-1-1 detectors and
External source control N9000B-ESC External source control for Keysight EXG, MXG, and PSG signal generaters; includes
N9000B-C75 Not compatible with Options T03 or T06; compatible with N9000B-503 and
N9000B-507 only
bandwidths; tune and listen, and measure at marker are also available
3 BNC cables and 1 cross-over L AN cable; compatible with N9000B-503 and N9000B-507 only
Step 10. Choose operating system
Description Option number Additional information
Windows Embedded Standard 7 Standard Installed as N9000B-W7X
Step 11. Add security features
Description Option number Additional information
Additional, removable solid-state drive Exclude launch program N9000B-SF1 Prevents the launching of Windows programs from the instrument application Prohibit saving results N9000B-SF2 Prevents the saving/recall of measurement results or user congurations to/from
Step 12. Add rear panel output utilities
Description Option number Additional information
Second IF output N9000B-CR3 Wideband IF out; output on Aux IF connector at rear panel; compatible with N9000B-503
N9000B-SSD Provides a fully-imaged, removable solid-state drive in addition to the one installed in the
instrument
instrument’s data storage
and N9000B-507 only
04 | Keysight | N9000B CXA X-Series Signal Analyzer, Multi-touch - Configuration Guide
Congure Your Keysight CXA Signal Analyzer (Continued)
Step 13. Choose measurement application or software and license type
Note: The last two letters of the ordering numbers indicate the license type—FP stands for xed perpetual, TP for transportable perpetual; it is recommended that you congure each application with the same license type; visit www.keysight.com/nd/X-series_transportable for more information
about transportable licenses.
Description Fixed license Transportable
license
Cellular communications
LTE/LTE-Advanced FDD
LTE/LTE-Advanced TDD
W-CDMA/HSPA+ N9073C-1FP N9073C-1TP Standard-based, one-button W-CDMA measurements
General purpose
Spectrum analyzer Standard Not available Traditional spectrum analysis plus many new and enhanced functions; power
Analog demodulation N9063C-1FP N906 3C-1T P Installed as N9063C-2FP or -2TP and N9063C-3FP or -3TP. Adds one-button
Phase noise W9068C-2FP W9068C-2TP One-button phase noise measurements in frequency domain (log plot) and time domain
Noise gure N9069C-3FP
MATLAB software N6171A-M01 Not available Basic signal analysis package; adds MATLAB software environment and the Instrument
Pulse N9 067C-1FP Not available Characterize pulsed RF signals in the time domain, with phase, frequency and statistical
89600 VSA software Not available 89601B
N9080C-1FP N9080C-1TP Standard-based, one-button LTE-FDD measurements N9080C-2FP N9080C-2TP Standard-based, one-button LTE-Advanced FDD measurements; requires
N9082C-1FP N90 82C-1T P Standard-based, one-button LTE-TDD measurements N9082C-2FP N9082C-2TP Standard-based, one-button LTE-Advanced TDD measurements; requires
N9073C-2FP N9073C-2TP Adds HSPA measurements; requires 1FP/1TP N9073C-3FP N9073C-3TP Adds HSPA+ measurements; requires 1FP/1TP, 2FP/2TP
N9069C-3TP
(requires
preamplier)
N6171A-M02 Not available Standard signal analysis package; includes basic package and adds Communications
N6171A-M03 Not available Advanced signal analysis package; includes standard package and adds Filter Design
(requires
preamplier)
(transportable license is standard)
Additional information
N9080C-1FP/1TP
N9082C-1FP/1T P
measurements based on industry specications
measurement for AM/FM/PM demodulation with metrics, tune and listen, and AF spectrum; supports audio output (output voltage proportional to frequency deviation). FM Stereo and RDS are included.
(spot frequency) Installed as N9069C-1FP or -1TP and N9069C-2FP or -2TP. Adds one-button
measurements for noise gure, gain, and related metrics; requires preamplier to meet specications; works with Keysight N400xA Series smart noise sources and 346 Series noise sources; supports U7227 Series USB external preampliers; includes the
advanced NF measurement features including external LO control over GPIB/LAN/USB, multi-stage converter tests with system LO, and manual mode to simulate the legacy NF meter.
Control Toolbox (not upgradeable)
Toolbox and Signal Processing Toolbox (not upgradeable)
Toolbox, RF Toolbox, and System Test (not upgradeable)
analysis of large pulse sets. Industry-leading measurement software for evaluating and troubleshooting signals in R&D; PC-based software supporting more than 40 measurement platforms, plus more than 75 signal standards and modulation types including MIMO analysis;
www.keysight.com/nd/89600vsa
05 | Keysight | N9000B CXA X-Series Signal Analyzer, Multi-touch - Configuration Guide
Congure Your Keysight CXA Signal Analyzer (Continued)
Step 14. Choose physical instrument conguration
Description Option number Additional information
Bench top conguration Standard Provides two side carrying straps, four rear feet, and four bottom feet with a tilt stand Portable conguration N9000B-PRC Provides a convenient, pivoting carrying handle as well as rubber protective corners and end
guards; this conguration is intended for applications requiring more rugged packaging, such as in the eld
Step 15. Choose accessories
Description Option number Additional information
Mouse, USB interface Standard Every CXA is shipped with a USB mouse which enhances the usability of the
Windows operating system
User guide Standard – US – English localization
– All user documentation is included in the CXA’s embedded, context-
sensitive help system and on a CD that is shipped with the instrument
– User documentation can be downloaded from:
www.keysight.com/nd/cxa_manuals
Power cord Standard Dependent upon region of use Rack mount Front handles 1CN103A Adds front handles to the CXA Rack mount with handles 1CP105A Adds rack mount anges and handles to the CX A Rack slide 1CR013A Adds a non-tilting rack slide to the CX A USB DVD-ROM/CD-R/RW drive 1DV R001A Enhances the usability of the Windows operating system Mouse, USB interface 1MSE001A US 65-key USB keyboard 1KBD001A Smaller keyboard Front panel protection cover N9000B-CVR
Minimum loss pad, 50 to 75 Ω (type-N to BNC) MLP0 01A – 50 Ω type-N male to 75 Ω BNC female adapter
USB external preamplier, 10 MHz to 4 GHz USB external preamplier, 0.1 to 26.5 GHz U7227C USB external preamplier, 2 to 50 GHz U7227F
1CM113A Adds rack mount anges to the CXA
– Frequency range: 9 MHz to 2 GHz – Input/output return loss: 20 and 11 dB – Insertion loss: 5.7 dB
U7227A
For more information on accessories go to: www.keysight.com/nd/accessories
CXA bench top conguration
06 | Keysight | N9000B CXA X-Series Signal Analyzer, Multi-touch - Configuration Guide
Congure Your Keysight CXA Signal Analyzer (Continued)
Step 16. Choose warranty length
Description Option number Additional information
Return-to-Keysight warranty, 3 years Standard 3-year warranty is included at no additional charge Warranty Assurance Plan, Return-to-Keysight, 5 years Warranty Assurance Plan, Return-to-Keysight, 7 years Warranty Assurance Plan, Return-to-Keysight, 10 years
Step 17. Add calibration, technical training, support, and upgrade services
Description Option number Additional information
Commercial calibration
certicate with test data
Keysight Cal + uncertainties + guardbanding (accredited cal) ANSI Z 5 4 0-1-19 94 calibr ation N9000B-A6J Provides ANSI Z540 compliant calibration from factory Calibration Assurance Plan, Return-to-Keysight, 3 years Calibration Assurance Plan, Return-to-Keysight, 5 years Calibration Assurance Plan, Return-to-Keysight, 7 years Calibration Assurance Plan, Return-to-Keysight, 10 years Service: remote scheduled productivity assistance
Service: 1-day start-up assistance PS-S20-01 Training on how to operate your instrument effectively (recommended) Service: productivity assistance PS- S 2 0 -100 Daily instrument and application consulting using your equipment and
Service: custom engineering service PS-X10-100 Application-specic technical assistance
R-51B-001-5Z
R-51B -001-7Z
R-51B-001-10Z
N9000B-UK6 Calibration certicate only available at time of instrument purchase; only
provides measurement results
N9000B-AMG Provides ISO 17025A accredited calibration from factory
R-50C-011-3
R-50C-011-5
R-50C-011-7
R-50C-011-10
PS-S10-100 Hourly phone-in technical support service designed to help you
Keysight tests your instrument against its original specications and automatically makes adjustments if outside of specied parameters;
pre- and post-adjustment measurement data reports also provided
understand and operate your equipment through convenient phone and Web access
device under test
Other calibration options may be available; for more information on calibration go to: www.keysight.com/nd/calibration For more information on training and application support services go to: www.keysight.com/nd/training
07 | Keysight | N9000B CXA X-Series Signal Analyzer, Multi-touch - Configuration Guide
Instrument Upgrades
Fast license-key upgrades for performance options that do not require additional hardware:
1. Place an order for the upgrade with Keysight and request to receive the option upgrade entitlement certicate and a one-time software upgrade license through
email
2. Redeem the certicate through the Web by following the instructions on the
certicate
3. Install the license le and latest sof tware in the CXA
4. Begin using the new capability
Installation and testing information is available at:
www.keysight.com/nd/cxa_upgrades
1, 2
You Can Upgrade!
Options can be added af ter your initial purchase.
Most X-Series
options are license­key upgradeable.
UP
GRADE
Description Upgrade
number
Increase analysis bandwidth from 10 to 25 MHz
Add preamplier, 3 GHz N9000BU-P03 None Add preamplier, 7.5 GHz N9000BU-P07 507, 513 or 526 Not compatible with Option 503 Add preamplier, 13.6 GHz N9000BU-P13 513 or 526 Not compatible with Option 503 or 507 Add preamplier, 26.5 GHz N9000BU-P26 Add ne resolution
step attenuator Upgrade to the precision frequency reference Add tracking generator, 3 GHz N9000BU-T03 None Requires hardware and license key; not compatible with Options 513
Add tracking generator, 6 GHz N9000BU-T06 None Requires hardware and license key; not compatible with Options 503,
Add basic EMI precompliance features Add external source control N9000BU-ESC None Adds feature to control the Keysight EXG, MXG, and PSG signal
Add second IF output N9000BU-CR3 None Requires hardware and license key; not compatible with Options 513
Add enhanced display package N9000BU-EDP None Add security features, exclude launch program Add security features, prohibit saving results Add removable solid state drive
N9000BU-B25 None
N9000BU-FSA None
N9000BU-PFR None
N9000BU-EMC None
N9000BU-SF1 None Prevents the launching of Windows programs from
N9000BU-SF2 None Prevents the saving/recall of measurement results or user
N9000BU-SSD None Provides a fully-imaged, removable solid-state drive
Requirements CXA must
already include the following)
526
Additional information
Not compatible with Option 503, 507, or 513
or 526
513, or 526
generators; includes 3 BNC cables and 1 cross-over LAN cable; not compatible with Options 513 or 526
or 526
the instrument application
congurations to/from instrument’s data storage
1. At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was veried to be within its warranted specications. Within one year of the initial calibration date of the analyzer, this option is fully calibrated with no further adjustment or verication testing.
2. If this analyzer has been adjusted as part of a repair or calibration during its rst year, or if the analyzer is more than one year old, additional adjustment and performance verication tests are required to ensure that some newly installed options are functioning properly. However, the completion of these tests does not guarantee that the analy zer meets all warranted specications.
For more information on accessories go to: www.keysight.com/nd/accessories
08 | Keysight | N9000B CXA X-Series Signal Analyzer, Multi-touch - Configuration Guide
Related Literature
Keysight CXA signal analyzers
Publication title Publication number
N9000B CXA X-Series Signal Analyzer, Multi-touch, Data Sheet 5992-1274 EN X-Series Signal Analyzers - Brochure 5992-1316EN X-Series Measurement Applications, Brochure 5989-8019EN
09 | Keysight | N9000B CXA X-Series Signal Analyzer, Multi-touch - Configuration Guide
From Hewlett-Packard through Agilent to Keysight
For more than 75 years, we‘ve been helping you unlock measurement insights. Our unique combination of hardware, software and people can help you reach your next breakthrough. Unlocking measurement insights since 1939.
1939 THE FUTURE
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with a three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products.
Keysight Assurance Plans www.keysight.com/find/AssurancePlans
Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate
measurements.
Keysight Infoline
www.keysight.com/find/service
Keysight’s insight to best in class information management. Free access to your Keysight equipment company reports and e-library.
Keysight Channel Partners www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience.
For more information on Keysight
Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus
Americas
Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444
Asia Pacic
Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626
Japan 0120 (421) 345
Korea 080 769 0800 Malaysia 1 800 888 848
Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100
Europe & Middle East
Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100
Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353
Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT)
United Kingdom 0800 0260637
For other unlisted countries: www.keysight.com/find/contactus
(BP -0 1-0 1-16)
www.keysight.com/find/cxa
www.keysight.com/go/quality
Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System
This information is subject to change without notice.
© Keysight Technologies, 2016
Published in USA, January 28, 2016 5992-1275EN
www.keysight.com
Loading...