This conguration guide will help you
determine which performance options,
measurement applications, accessories,
and services to include with your new
multi-touch CXA or to add as upgrades to
This step-by-step process will help you congure your new CXA X-Series signal analyzer.
Tailor the performance to meet your requirements.
Included in base product
Standard options and accessories come with the CXA base model at no additional
charge and do not need to be ordered. They include:
– Spectrum analyzer measurement application
– Dual-core, high-performance processor, 8 GB RAM, removable solid-state drive
– Frequency reference
– 10 MHz analysis bandwidth
– Enhanced phase noise
– Windows Embedded Standard 7
– Benchtop conguration
– Mouse
– User guide
– Power cord
– 3-year return-to-Keysight warranty
Step 1. Select maximum frequency range (required option; frequency range not upgradeable)
DescriptionOption numberAdditional information
Frequency range, 9 kHz to 3.0 GHzN9000B-503
Frequency range, 9 kHz to 7.5 GHzN9000B-507
Frequency range, 9 kHz to 13.6 GHzN9000B-513
Frequency range, 9 kHz to 26.5 GHzN9000B-526
Get More Information
For a summary of specications,
refer to the N9000B CXA data
sheet (literature number 59921274EN ).
A full set of specications are
available in the N9000B CX A
Signal Analyzer Specication
Guide at www.keysight.com/nd/
cxa_specications.
Step 2. Add a preamplier
DescriptionOption numberAdditional information: Preampliers improve the noise oor for low-level signal
detection; +20 dB: 100 kHz to 26.5 GHz
Preamplier, 100 kHz to 3.0 GHzN9000B-P03Compatible with N9000B-503, N9000B-507, N9000B-513,
and N9000B-526
Preamplier, 100 kHz to 7.5 GHz N9000B-P07Compatible with N9000B-507, N9000B-513, and N9000B-526
Preamplier, 100 kHz to 13.6 GHzN9000B-P13Compatible with N9000B-513 and N9000B-526
Preamplier, 100 kHz to 26.5 GHzN9000B-P26Compatible with N9000B-526
Step 3. Choose frequency reference
DescriptionOption numberAdditional information
Frequency referenceStandardAging rate: ± 1 x 10–6/year
Precision frequency referenceN9000B-PFR Reduces frequency drift for more accurate measurements; aging rate: ± 1 x 10–7 /year
Step 4. Choose an attenuator
DescriptionOption numberAdditional information
Mechanical attenuatorStandard10 dB steps, 0 to 50 dB, for N9000B-503 and N9000B-507
10 dB steps, 0 to 70 dB, for N9000B-513 and N9000B-526
Fine resolution step attenuatorN9000B-FSAAllows 2 dB steps for the full range of the attenuator
Step 5. Choose analysis bandwidth
DescriptionOption numberAdditional information
10 MHz analysis bandwidthStandardUseful for most 2G and 3G measurement applications
25 MHz analysis bandwidthN9000B-B25Extends the analysis (demod) bandwidth from 10 to 25 MHz; useful for most cellular
communications, wireless connectivity, and audio/video broadcasting measurement
applications
Congure Your Keysight CXA Signal Analyzer (Continued)
Step 6. Add a tracking generator
DescriptionOption numberAdditional information
Tracking generator, 9 kHz to 3.0 GHzN9000B-T03Compatible with N9000B-503, N9000B-507 only
Tracking generator, 9 kHz to 6.0 GHz N9000B-T06Compatible with N9000B-507 only
Step 7. Add a 75 Ω input connector
DescriptionOption numberAdditional information
Connector, 75 Ω additional RF input,
1.5 GHz
Step 8. Choose performance
DescriptionOption numberAdditional information
Enhanced phase noiseStandardInstalled as N9000B-EP4
Step 9. Add optional features
DescriptionOption numberAdditional information
Enhanced display packageN9000B-EDPIncludes spectrogram, trace zoom, and zone span
Basic precompliance EMIN9000B-EMCPerform EMI precompliance measurements with CISPR 16-1-1 detectors and
External source controlN9000B-ESCExternal source control for Keysight EXG, MXG, and PSG signal generaters; includes
N9000B-C75Not compatible with Options T03 or T06; compatible with N9000B-503 and
N9000B-507 only
bandwidths; tune and listen, and measure at marker are also available
3 BNC cables and 1 cross-over L AN cable; compatible with N9000B-503 and
N9000B-507 only
Step 10. Choose operating system
DescriptionOption numberAdditional information
Windows Embedded Standard 7StandardInstalled as N9000B-W7X
Step 11. Add security features
DescriptionOption numberAdditional information
Additional, removable
solid-state drive
Exclude launch programN9000B-SF1Prevents the launching of Windows programs from the instrument application
Prohibit saving results N9000B-SF2Prevents the saving/recall of measurement results or user congurations to/from
Step 12. Add rear panel output utilities
DescriptionOption numberAdditional information
Second IF outputN9000B-CR3 Wideband IF out; output on Aux IF connector at rear panel; compatible with N9000B-503
N9000B-SSD Provides a fully-imaged, removable solid-state drive in addition to the one installed in the
Congure Your Keysight CXA Signal Analyzer (Continued)
Step 13. Choose measurement application or software and license type
Note: The last two letters of the ordering numbers indicate the license type—FP stands for xed perpetual, TP for transportable perpetual; it is
recommended that you congure each application with the same license type; visit www.keysight.com/nd/X-series_transportable for more information
N6171A-M02Not availableStandard signal analysis package; includes basic package and adds Communications
N6171A-M03Not availableAdvanced signal analysis package; includes standard package and adds Filter Design
(requires
preamplier)
(transportable
license is
standard)
Additional information
N9080C-1FP/1TP
N9082C-1FP/1T P
measurements based on industry specications
measurement for AM/FM/PM demodulation with metrics, tune and listen, and AF
spectrum; supports audio output (output voltage proportional to frequency deviation).
FM Stereo and RDS are included.
(spot frequency)
Installed as N9069C-1FP or -1TP and N9069C-2FP or -2TP. Adds one-button
measurements for noise gure, gain, and related metrics; requires preamplier to
meet specications; works with Keysight N400xA Series smart noise sources and 346
Series noise sources; supports U7227 Series USB external preampliers; includes the
advanced NF measurement features including external LO control over GPIB/LAN/USB,
multi-stage converter tests with system LO, and manual mode to simulate the legacy NF
meter.
Control Toolbox (not upgradeable)
Toolbox and Signal Processing Toolbox (not upgradeable)
Toolbox, RF Toolbox, and System Test (not upgradeable)
analysis of large pulse sets.
Industry-leading measurement software for evaluating and troubleshooting signals in
R&D; PC-based software supporting more than 40 measurement platforms, plus more
than 75 signal standards and modulation types including MIMO analysis;
Congure Your Keysight CXA Signal Analyzer (Continued)
Step 14. Choose physical instrument conguration
DescriptionOption numberAdditional information
Bench top congurationStandardProvides two side carrying straps, four rear feet, and four bottom feet with a tilt stand
Portable congurationN9000B-PRCProvides a convenient, pivoting carrying handle as well as rubber protective corners and end
guards; this conguration is intended for applications requiring more rugged packaging, such as
in the eld
Step 15. Choose accessories
DescriptionOption numberAdditional information
Mouse, USB interface Standard Every CXA is shipped with a USB mouse which enhances the usability of the
Windows operating system
User guideStandard – US – English localization
– All user documentation is included in the CXA’s embedded, context-
sensitive help system and on a CD that is shipped with the instrument
– User documentation can be downloaded from:
www.keysight.com/nd/cxa_manuals
Power cord StandardDependent upon region of use
Rack mount
Front handles 1CN103AAdds front handles to the CXA
Rack mount with handles1CP105AAdds rack mount anges and handles to the CX A
Rack slide1CR013AAdds a non-tilting rack slide to the CX A
USB DVD-ROM/CD-R/RW drive1DV R001AEnhances the usability of the Windows operating system
Mouse, USB interface1MSE001A
US 65-key USB keyboard1KBD001ASmaller keyboard
Front panel protection coverN9000B-CVR
Minimum loss pad, 50 to 75 Ω (type-N to BNC)MLP0 01A– 50 Ω type-N male to 75 Ω BNC female adapter
USB external preamplier, 10 MHz to 4 GHz
USB external preamplier, 0.1 to 26.5 GHzU7227C
USB external preamplier, 2 to 50 GHzU7227F
1CM113AAdds rack mount anges to the CXA
– Frequency range: 9 MHz to 2 GHz– Input/output return loss: 20 and 11 dB– Insertion loss: 5.7 dB
U7227A
For more information on accessories go to: www.keysight.com/nd/accessories
Congure Your Keysight CXA Signal Analyzer (Continued)
Step 16. Choose warranty length
DescriptionOption numberAdditional information
Return-to-Keysight warranty, 3 yearsStandard3-year warranty is included at no additional charge
Warranty Assurance Plan,
Return-to-Keysight, 5 years
Warranty Assurance Plan,
Return-to-Keysight, 7 years
Warranty Assurance Plan,
Return-to-Keysight, 10 years
Step 17. Add calibration, technical training, support, and upgrade services
DescriptionOption numberAdditional information
Commercial calibration
certicate with test data
Keysight Cal + uncertainties
+ guardbanding (accredited cal)
ANSI Z 5 4 0-1-19 94 calibr ationN9000B-A6JProvides ANSI Z540 compliant calibration from factory
Calibration Assurance Plan,
Return-to-Keysight, 3 years
Calibration Assurance Plan,
Return-to-Keysight, 5 years
Calibration Assurance Plan,
Return-to-Keysight, 7 years
Calibration Assurance Plan,
Return-to-Keysight, 10 years
Service: remote scheduled
productivity assistance
Service: 1-day start-up assistance PS-S20-01 Training on how to operate your instrument effectively (recommended)
Service: productivity assistance PS- S 2 0 -100 Daily instrument and application consulting using your equipment and
Service: custom engineering service PS-X10-100 Application-specic technical assistance
R-51B-001-5Z
R-51B -001-7Z
R-51B-001-10Z
N9000B-UK6Calibration certicate only available at time of instrument purchase; only
provides measurement results
N9000B-AMGProvides ISO 17025A accredited calibration from factory
R-50C-011-3
R-50C-011-5
R-50C-011-7
R-50C-011-10
PS-S10-100 Hourly phone-in technical support service designed to help you
Keysight tests your instrument against its original specications and
automatically makes adjustments if outside of specied parameters;
pre- and post-adjustment measurement data reports also provided
understand and operate your equipment through convenient phone and
Web access
device under test
Other calibration options may be available; for more information on calibration go to: www.keysight.com/nd/calibration
For more information on training and application support services go to: www.keysight.com/nd/training
Fast license-key upgrades for performance options that do not require additional
hardware:
1. Place an order for the upgrade with Keysight and request to receive the option
upgrade entitlement certicate and a one-time software upgrade license through
email
2. Redeem the certicate through the Web by following the instructions on the
certicate
3. Install the license le and latest sof tware in the CXA
4. Begin using the new capability
Installation and testing information is available at:
www.keysight.com/nd/cxa_upgrades
1, 2
You Can Upgrade!
Options can be added af ter your
initial purchase.
Most X-Series
options are licensekey upgradeable.
UP
GRADE
DescriptionUpgrade
number
Increase analysis bandwidth
from 10 to 25 MHz
Add preamplier, 3 GHzN9000BU-P03None
Add preamplier, 7.5 GHzN9000BU-P07507, 513 or 526Not compatible with Option 503
Add preamplier, 13.6 GHz N9000BU-P13513 or 526Not compatible with Option 503 or 507
Add preamplier, 26.5 GHzN9000BU-P26
Add ne resolution
step attenuator
Upgrade to the precision
frequency reference
Add tracking generator, 3 GHzN9000BU-T03NoneRequires hardware and license key; not compatible with Options 513
Add tracking generator, 6 GHzN9000BU-T06NoneRequires hardware and license key; not compatible with Options 503,
Add basic EMI
precompliance features
Add external source controlN9000BU-ESCNoneAdds feature to control the Keysight EXG, MXG, and PSG signal
Add second IF output N9000BU-CR3 NoneRequires hardware and license key; not compatible with Options 513
N9000BU-SF1NonePrevents the launching of Windows programs from
N9000BU-SF2NonePrevents the saving/recall of measurement results or user
N9000BU-SSDNoneProvides a fully-imaged, removable solid-state drive
Requirements CXA must
already include the
following)
526
Additional information
Not compatible with Option 503, 507, or 513
or 526
513, or 526
generators; includes 3 BNC cables and 1 cross-over LAN cable; not
compatible with Options 513 or 526
or 526
the instrument application
congurations to/from instrument’s data storage
1. At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was veried to be within its
warranted specications. Within one year of the initial calibration date of the analyzer, this option is fully calibrated with no further adjustment or
verication testing.
2. If this analyzer has been adjusted as part of a repair or calibration during its rst year, or if the analyzer is more than one year old, additional adjustment and
performance verication tests are required to ensure that some newly installed options are functioning properly. However, the completion of these tests
does not guarantee that the analy zer meets all warranted specications.
For more information on accessories go to: www.keysight.com/nd/accessories
N9000B CXA X-Series Signal Analyzer, Multi-touch, Data Sheet5992-1274 EN
X-Series Signal Analyzers - Brochure5992-1316EN
X-Series Measurement Applications, Brochure5989-8019EN
For more than 75 years, we‘ve been helping you unlock measurement insights. Our
unique combination of hardware, software and people can help you reach your next
breakthrough. Unlocking measurement insights since 1939.
1939 THE FUTURE
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s committed to superior product quality and lower total cost of
ownership. Keysight is the only test and measurement company with a
three-year warranty standard on all instruments, worldwide. And, we provide
a one-year warranty on many accessories, calibration devices, systems and
custom products.
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus