Keysight Technologies M9410A, M9411A Configuration Manual

380 MHz to 6 GHz
M9410A and M9411A VXT PXIe Vector Transceivers
Overview
This configuration guide contains information to help you configure your M9410A
optional capabilities at time of purchase provides the lowest overall cost.
CONFIGURATION
GUIDE
Page 1Find us at www.keysight.com
Included in base product
Standard options and accessories come with the VXT base model at no additional
charge and do not need to be ordered. They include:
• Option F06: Frequency range, 380 MHz to 6 GHz
• Option B3X: 300 MHz modulation and analysis bandwidth
• Option M02: Memory, 256 MSa
• N9060EM0E I/Q analyzer
• Cable, MMPX male to SMB male, 260 mm
• Getting Started Guide
Hardware
A. Select options for VXT PXIe vector transceiver
Step 1. Choose your module
M9410A-001 VXT PXIe vector transceiver, 2-slot
M9411A-001
VXT PXIe vector transceiver, 3-slot, supporting Keysight PathWave FPGA Programming Environment Software
Step 2. Choose modulation and analysis bandwidth
Option B3X 300 MHz Included in base configuration
Option B6X 600 MHz
Option B12 1.2 GHz
Step 3. Choose memory size
Option M02 256 MSa Included in base configuration
Option M05 512 MSa
Step 4. Add high output power
Option 1EA High output power
Step 5. Add duplex port
Option HDX Half duplex port
Step 6. Add measurement capability
Option MMO Timing synchronization for MIMO
Option PHC Phase Coherence; requires Option MMO
Option MTS Multi-tester synchronization across chassis; requires Option MMO
B. Add M9300A PXIe frequency reference
Step 1. Add an M9300A PXIe frequency reference (Occupies 1 slot) One frequency reference required per system to meet data sheet specifications.
M9300A
PXIe frequency reference
Five 100 MHz outputs
One 10 MHz output
Internal 10 MHz OCXO timebase output
Page 2Find us at www.keysight.com
C. Select controller (Either embedded controller or via PC)
Step 1. Select embedded controller
M9037A-M08 High-performance embedded controller Intel i7-4700EQ quad-core processor,
2.4 GHz, 8-thread, 8 GB RAM
Select M9037A for the best performance if you have memory intensive applications, multiple applications running in parallel, or if a lot of data is sent to the PC from the PXIe chassis. Features removable SSD drive for security and x8 connector from front for connection to second chassis
Step 2. Upgrade from standard memory size (Optional)
M9037A-M16 Memory upgrade to 16 GB RAM
16 GB RAM is required for 5G NR measurement
Step 3. Select an operating system
M9037A-WE6
M9037A-W16
1
Microsoft Windows Embedded Standard 7 (64-bit)
Microsoft Windows 10 IoT Enterprise LTSB (64-bit)
To use your desktop PC as a controller
2, 3
M9048A PCIe Host Adapter: Gen 2, x8
M9048B
M9049A
PCIe Host Adapter: Single Port (x8), Gen 3
PCIe Host Adapter: Dual Port (x16), Gen 3
Y1202A PCIe cable
M9021A 4PCIe Cable Interface: Gen 2, x8
M9022A
M9023A
PXIe System Module: Single Port (x8), Gen 3
PXIe System Module: Dual Port (x16), Gen 3
PXIe System Module with
M9024A
Connectivity Expansion: Dual Port (x16) Gen 3
1. The M9018B or M9019A 18-slot chassis includes empty space to the left of the 1st functional slot. The embedded controller occupies that empty space and the 1st functional slot.
2. For list of qualified external controllers, please see Test Computer List Technical Note literature no. 5990-7632EN.
3. For more detailed chassis configuration information including multi-chassis, see Interface Modules and Adapters for PXIe and AXIe Systems literature no. 5992-0377EN.
4. The M9021A can only be used with the Keysight M9018B.
Page 3Find us at www.keysight.com
C. Select controller (Either embedded controller or via PC) (Continued)
PC requirements for M9410A and M9411A VXT PXIe vector transceivers control
Functions Description
Operating system
Processor speed 1.86 GHz dual core minimum
Available memory
Available disk space on Drive C 8 GB
Windows 7 (64 bit)
Windows 10 (64 bit)
8 GB minimum
16 GB recommended
D. Select a chassis and accessories
Step 1. Select a chassis
M9010A 10-slot PXIe chassis
M9018B 18-slot PXIe chassis Gen 2
M9019A 18-slot PXIe chassis Gen 3
Step 2. Choose enough slot blocker kits and EMC filler panels to fill every open slot Recommended to achieve data sheet specifications
1
Y1212A Slot blocker kit: 5 slots
PXI EMC filler panel kit: 5 slots
Y1213A
Non-EMC filler panels are included with the M9018B or M9019A PXIe 18-slot chassis.
1. For list of qualified external controllers, please see Test Computer List Technical Note literature no. 5990-7632EN.
Page 4Find us at www.keysight.com
D. Select a chassis and accessories (Continued)
Step 3. Choose a rack mount kit ¹ (Optional)
Y1271A
Y1215C
Rack mount kit for M9010A and Y1217A rail kit
Rack mount kit for M9018B or M9019A 18-slot PXIe chassis
Y1216B
Rack mount kit for M9018B or M9019A 18-slot PXIe chassis
Step 4. Choose an air inlet kit 2 (Optional) Recommended for rack mounted systems with less than 1U space below chassis.
Y1214B
Air inlet kit: M9018B or M9019A 18-slot chassis
1
Step 5. Choose connecting cable
Y1810A Cable, MMPX male to SMB male, 260 mm
Y1811A Cable, MMPX male to MMPX male, 200 mm
Y1812A Cable, MMPX male to SMB male, 500 mm
Y1813A Cable, MMPX male to SMB male, 1000 mm
Y1814A Cable, SMA male to SMA male, 1220 mm
1. For more information on the rack mount kit, see the chassis data sheet, literature number 5992-1481EN.
2. For more information, please visit www.keysight.com/find/m9018b and
www.keysight.com/find/m9019a.
Page 5Find us at www.keysight.com
Software
E. Select measurement applications or software and license type for VXT PXIe vector transceiver
Step 1. Start with M9410A and M9411A base configuration
The VXT comes standard with the following software:
• Keysight IO Libraries Suite including Connection Expert
• Drivers for use with Matlab, Visual Studio (including VB Net, C#, C/C++), Keysight VEE
• Sample waveforms and programming examples
Step 2. Add X-Series Measurement Applications (Optional)
Measurement applications that start with the prefix “N” are measurement only applications and require waveform pack licenses for waveform playback. Applications that start with the prefix “Y” combine measurement applications with unlimited waveform playback capability.
Keysight offers 4 license types for the measurement applications. Each of the following license types are offered as perpetual or time-based. Visit www.keysight.com/find/
X-Series_apps for more information.
• Node-locked: Allows you to use the license on one specified instrument or
computer.
• Transportable: Allows you to move the license from one instrument or computer to another using Keysight’s online tool.
1
• USB portable: Allows you to move the license from one instrument or computer to another with a certified USB dongle.
• Floating: Allows you to access the license on networked instruments or computers from a server, one at a time.
1. Both IO library (version 18.1 or newer) and Connection Expert software need to be installed on the
PC controlling the PXI instruments. To download, visit www.keysight.com/find/iosuite.
Page 6Find us at www.keysight.com
E. Select measurement applications or software and license type for VXT PXIe vector transceiver (Continued)
Model name Description
N9054EM0E VMA Vector Modulation Analysis Measurement Application
N9054EM1E Vector Modulation Analysis Custom OFDM Application
N9071EM0E GSM/EDGE/Evo Measurement Application
Y9071EM0E GSM/EDGE/Evo Waveform and Measurement Application
N9073EM0E W-CDMA/HSPA+ Measurement Application
Y9073EM0E W-CDMA/HSPA+ Waveform and Measurement Application
N9077EM0E WLAN 802.11a/b/g/j/p/n/af/ah Measurement Application
Y9077EM0E
N9077EM1E WLAN 802.11ac/ax Measurement Application
Y9077EM1E WLAN 802.11ac/ax Waveform and Measurement Application
N9080EM0E LTE and LTE-Advanced FDD Measurement Application
Y9080EM0E
N9080EM3E NB-IoT and eMTC FDD Measurement Application
Y9080EM3E NB-IoT and eMTC FDD Waveform and Measurement Application
N9082EM0E LTE and LTE-Advanced TDD Measurement Application
Y9082EM0E
N9085EM0E 5G NR Measurement Application
Y9085EM0E 5G NR Waveform and Measurement Application
WLAN 802.11a/b/g/j/p/n/af/ah Waveform and Measurement Application
LTE and LTE-Advanced FDD Waveform and Measurement Application
LTE and LTE-Advanced TDD Waveform and Measurement Application
Step 3. Add Signal Studio software 1 (Optional) Generate standard-compliant test signals validated by Keysight for receiver and
component test.
N7600EMBC Signal Studio for W-CDMA/HSPA+, waveform playback
N7602EMBC Signal Studio for GSM/EDGE/Evo, waveform playback
N7624EMBC
N7625EMBC Signal Studio for LTE/LTE-Advanced TDD, waveform playback
N7617EMBC Signal Studio for WLAN 802.11, waveform playback
N7608EMBC Signal Studio Pro for Custom Modulation, waveform playback
N7630EMBC Signal Studio Pro for Pre-5G, waveform playback
N7631EMBC Signal Studio Pro for 5G NR, waveform playback
N7609EMBC
N7614EMBC Signal Studio for Power Amplifier Test, waveform playback
N7650B 5/50 pack Signal Studio Waveform Licenses
1. For more information, see Signal Studio brochure, literature number 5989-6448EN or Signal
Studio configuration assistant at http://rfmw.em.keysight.com/wireless/helpfiles/all-in-one_ config_asst/ssconfig.html.
Signal Studio for LTE/LTE-Advanced/LTE-A Pro FDD, waveform playback
Signal Studio for Global Navigation Satellite System (GNSS), waveform playback
Page 7Find us at www.keysight.com
E. Select measurement applications or software and license type for VXT PXIe vector transceiver (Continued)
Step 4. Add 89600 VSA software (Optional)
89600 vector signal analysis (VSA) software
89601B (transportable license is standard)
Industry-leading measurement software for evaluating and troubleshooting signals in R&D; PC-based software supporting more than 30 measurement platforms, plus more than 75 signal standards and modulation types including MIMO analysis; www.keysight.
com/find/89600_VSA
Step 5. Add MATLAB software 1 (Optional)
MATLAB software
N6171A Create arbitrary waveforms, customize
measurement and data analysis routines, create your own instruments applications and test systems, automate measurements, signal generation, and report generation
F. Calibration, start-up assistance
Model name Description
M9410A-UK6
M9411A-UK6
M9300A-UK6
PS-S20-01
R-50C-011-3 Calibration Assurance Plan - Return to Keysight, 3 years
R-50C-011-5 Calibration Assurance Plan - Return to Keysight, 5 years
R-50C-011-7 Calibration Assurance Plan - Return to Keysight, 7 years
R-50C-011-10 Calibration Assurance Plan - Return to Keysight, 10 years
Commercial calibration certificate with test data
Commercial calibration certificate with test data for M9300A
Service: 1-day start-up assistance
Calibration certificate with measurement results available only at time of purchase.
Calibration certificate with measurement results available only at time of purchase.
Training on how to operate your instrument effectively
Global warranty
Keysight provides the peace of mind that today’s high tech industry requires. Your
investment is protected by Keysight’s global reach in more than 100 countries (either
directly or through distributors). The warranty gives you convenient standard coverage
for the country in which the product is used, eliminating the need to ship equipment
back to the country of purchase. Keysight’s warranty service provides:
• All parts and labor necessary to return your investment to full specified performance
• Recalibration for products supplied originally with a calibration certificate
• Return shipment
1. For more information on MATLAB software, visit www.keysight.com/find/n6171a.
Page 8Find us at www.keysight.com
One day start-up assistance
A Keysight Technologies applications engineer will get you started quickly by helping
you install the modules in a chassis, configure the controller, load software and start
making measurements.
Calibration services
The modular products are factory calibrated and shipped with an ISO-9002, NIST-
traceable calibration certificate. A one year calibration cycle is recommended.
Upgrading Your System
Your product can be easily upgraded after the initial purchase. Fast license-key
upgrades for performance options that do not require additional hardware:
1. Contact your Keysight representative to place an order for an option upgrade.
2. You will receive your hardware entitlement certificate via email.
3. Redeem the certificate online by following the instructions provided to receive a license key file.
4. Install the license key file using the Keysight License Manager.
5. Begin using the new capability
1, 2
.
Description Upgrade number (x = 0 or 1)
Bandwidth upgrade, 300 MHz to 600 MHz M941xAU-B6X
Bandwidth upgrade, 300 MHz to 1.2 GHz M941xAU-B12
Bandwidth upgrade, 600 MHz to 1.2 GHz M941xAU-BU1
Memory upgrade, 256 MSa to 512 MSa M941xAU-M05
Add high output power M941xAU-1EA
Add half duplex port M941xAU-HDX
Timing synchronization for MIMO M941xAU-MMO
Multi-tester synchronization across chassis M941xAU-MTS
Phase coherence M941xAU-PHC
1. At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was verified to be within its warranted specifications. Within one year of the initial calibration date of the analyzer, this option is fully calibrated with no further adjustment or verification testing.
2. If this transceiver has been adjusted as part of a repair or calibration during its first year, or if the transceiver is more than one year old, additional adjustment and performance verification tests are required to ensure that some newly installed options are functioning properly. However, the completion of these tests does not guarantee that the transceiver meets all warranted specifications.
Page 9Find us at www.keysight.com
Using a Non-Keysight Chassis
The M9410A and M9411A VXT PXIe vector transceiver can be successfully installed in a
non-Keysight PXI chassis. Please use the following guidelines.
• Ensure that the chassis has enough consecutive PXIe or PXI-H slots to accommodate the M9410A or M9411A.
• Ensure that the chassis and controller support peer-to-peer PXI Express I/O switch topology.
• Ensure that controller selected is compatible with chassis.
Please contact your Keysight representative for more detailed information. For technical
assistance with non-Keysight equipment, please refer to the equipment manufacturer’s
website.
Related Literature
For more detailed product and specification information refer to the following literature
and web pages:
Publication title Publication number
M9018B and M9019A PXIe 18-slot chassis - Data Sheet 5992-1481EN
M9037A PXIe Embedded Controller - Data Sheet 5991-3661EN
X-Series Measurement Applications - Brochure 5989-8019EN
Simplify Signal Creation with Signal Studio Software ­Brochure
5989-6448EN
Learn more at: www.keysight.com
For more information on Keysight Technologies’ products, applications or services,
please contact your local Keysight office. The complete list is available at:
www.keysight.com/find/contactus
Find us at www.keysight.com
This information is subject to change without notice. © Keysight Technologies, 2018, Published in USA, September 19, 2018, 5992-3303EN
Page 10