Select M9037A for the best performance if you have
memory intensive applications, multiple applications
running in parallel, or if a lot of data is sent to the
PC from the PXIe chassis. Features removable SSD
drive for security and x8 connector from front for
connection to second chassis
Step 2. Upgrade from standard memory size (Optional)
M9037A-M16Memory upgrade to 16 GB RAM
16 GB RAM is required for 5G NR measurement
Step 3. Select an operating system
M9037A-WE6
M9037A-W16
1
Microsoft Windows Embedded
Standard 7 (64-bit)
Microsoft Windows 10 IoT
Enterprise LTSB (64-bit)
To use your desktop PC as a controller
2, 3
M9048APCIe Host Adapter: Gen 2, x8
M9048B
M9049A
PCIe Host Adapter: Single Port (x8),
Gen 3
PCIe Host Adapter: Dual Port (x16),
Gen 3
Y1202APCIe cable
M9021A 4PCIe Cable Interface: Gen 2, x8
M9022A
M9023A
PXIe System Module: Single Port
(x8), Gen 3
PXIe System Module: Dual Port
(x16), Gen 3
PXIe System Module with
M9024A
Connectivity Expansion: Dual Port
(x16) Gen 3
1. The M9018B or M9019A 18-slot chassis includes empty space to the left of the 1st functional slot.
The embedded controller occupies that empty space and the 1st functional slot.
2. For list of qualified external controllers, please see Test Computer List Technical Note literature
no. 5990-7632EN.
3. For more detailed chassis configuration information including multi-chassis, see Interface Modules
and Adapters for PXIe and AXIe Systems literature no. 5992-0377EN.
4. The M9021A can only be used with the Keysight M9018B.
Page 3Find us at www.keysight.com
C. Select controller (Either embedded controller or via PC) (Continued)
PC requirements for M9410A and M9411A VXT PXIe vector transceivers control
FunctionsDescription
Operating system
Processor speed1.86 GHz dual core minimum
Available memory
Available disk space on Drive C8 GB
Windows 7 (64 bit)
Windows 10 (64 bit)
8 GB minimum
16 GB recommended
D. Select a chassis and accessories
Step 1. Select a chassis
M9010A10-slot PXIe chassis
M9018B18-slot PXIe chassis Gen 2
M9019A18-slot PXIe chassis Gen 3
Step 2. Choose enough slot blocker kits and EMC filler panels to fill every open slot
Recommended to achieve data sheet specifications
1
Y1212ASlot blocker kit: 5 slots
PXI EMC filler panel kit: 5 slots
Y1213A
Non-EMC filler panels are included
with the M9018B or M9019A PXIe
18-slot chassis.
1. For list of qualified external controllers, please see Test Computer List Technical Note literature
no. 5990-7632EN.
Page 4Find us at www.keysight.com
D. Select a chassis and accessories (Continued)
Step 3. Choose a rack mount kit ¹ (Optional)
Y1271A
Y1215C
Rack mount kit for M9010A and
Y1217A rail kit
Rack mount kit for M9018B or
M9019A 18-slot PXIe chassis
Y1216B
Rack mount kit for M9018B or
M9019A 18-slot PXIe chassis
Step 4. Choose an air inlet kit 2 (Optional)
Recommended for rack mounted systems with less than 1U space below chassis.
Y1214B
Air inlet kit: M9018B or M9019A
18-slot chassis
1
Step 5. Choose connecting cable
Y1810ACable, MMPX male to SMB male, 260 mm
Y1811ACable, MMPX male to MMPX male, 200 mm
Y1812ACable, MMPX male to SMB male, 500 mm
Y1813ACable, MMPX male to SMB male, 1000 mm
Y1814ACable, SMA male to SMA male, 1220 mm
1. For more information on the rack mount kit, see the chassis data sheet, literature number
5992-1481EN.
2. For more information, please visit www.keysight.com/find/m9018b and
www.keysight.com/find/m9019a.
Page 5Find us at www.keysight.com
Software
E. Select measurement applications or software and license type for VXT PXIe vector
transceiver
Step 1. Start with M9410A and M9411A base configuration
The VXT comes standard with the following software:
• Keysight IO Libraries Suite including Connection Expert
• Drivers for use with Matlab, Visual Studio (including VB Net, C#, C/C++), Keysight
VEE
Measurement applications that start with the prefix “N” are measurement only
applications and require waveform pack licenses for waveform playback. Applications
that start with the prefix “Y” combine measurement applications with unlimited
waveform playback capability.
Keysight offers 4 license types for the measurement applications. Each of the following
license types are offered as perpetual or time-based. Visit www.keysight.com/find/
X-Series_apps for more information.
• Node-locked: Allows you to use the license on one specified instrument or
computer.
• Transportable: Allows you to move the license from one instrument or computer to
another using Keysight’s online tool.
1
• USB portable: Allows you to move the license from one instrument or computer to
another with a certified USB dongle.
• Floating: Allows you to access the license on networked instruments or computers
from a server, one at a time.
1. Both IO library (version 18.1 or newer) and Connection Expert software need to be installed on the
PC controlling the PXI instruments. To download, visit www.keysight.com/find/iosuite.
Page 6Find us at www.keysight.com
E. Select measurement applications or software and license type for VXT PXIe vector
transceiver (Continued)
Y9077EM1EWLAN 802.11ac/ax Waveform and Measurement Application
N9080EM0ELTE and LTE-Advanced FDD Measurement Application
Y9080EM0E
N9080EM3ENB-IoT and eMTC FDD Measurement Application
Y9080EM3ENB-IoT and eMTC FDD Waveform and Measurement Application
N9082EM0ELTE and LTE-Advanced TDD Measurement Application
Y9082EM0E
N9085EM0E5G NR Measurement Application
Y9085EM0E5G NR Waveform and Measurement Application
WLAN 802.11a/b/g/j/p/n/af/ah Waveform and Measurement
Application
LTE and LTE-Advanced FDD Waveform and Measurement
Application
LTE and LTE-Advanced TDD Waveform and Measurement
Application
Step 3. Add Signal Studio software 1 (Optional)
Generate standard-compliant test signals validated by Keysight for receiver and
component test.
N7600EMBCSignal Studio for W-CDMA/HSPA+, waveform playback
N7602EMBCSignal Studio for GSM/EDGE/Evo, waveform playback
N7624EMBC
N7625EMBCSignal Studio for LTE/LTE-Advanced TDD, waveform playback
N7617EMBCSignal Studio for WLAN 802.11, waveform playback
N7608EMBCSignal Studio Pro for Custom Modulation, waveform playback
N7630EMBCSignal Studio Pro for Pre-5G, waveform playback
N7631EMBCSignal Studio Pro for 5G NR, waveform playback
N7609EMBC
N7614EMBCSignal Studio for Power Amplifier Test, waveform playback
N7650B5/50 pack Signal Studio Waveform Licenses
1. For more information, see Signal Studio brochure, literature number 5989-6448EN or Signal
Studio configuration assistant at http://rfmw.em.keysight.com/wireless/helpfiles/all-in-one_ config_asst/ssconfig.html.
Signal Studio for LTE/LTE-Advanced/LTE-A Pro FDD, waveform
playback
Signal Studio for Global Navigation Satellite System (GNSS),
waveform playback
Page 7Find us at www.keysight.com
E. Select measurement applications or software and license type for VXT PXIe vector
transceiver (Continued)
Step 4. Add 89600 VSA software (Optional)
89600 vector
signal analysis
(VSA) software
89601B
(transportable
license is standard)
Industry-leading measurement software for
evaluating and troubleshooting signals in R&D;
PC-based software supporting more than
30 measurement platforms, plus more than
75 signal standards and modulation types
including MIMO analysis; www.keysight.
com/find/89600_VSA
Step 5. Add MATLAB software 1 (Optional)
MATLAB
software
N6171ACreate arbitrary waveforms, customize
measurement and data analysis routines,
create your own instruments applications and
test systems, automate measurements, signal
generation, and report generation
F. Calibration, start-up assistance
Model nameDescription
M9410A-UK6
M9411A-UK6
M9300A-UK6
PS-S20-01
R-50C-011-3Calibration Assurance Plan - Return to Keysight, 3 years
R-50C-011-5Calibration Assurance Plan - Return to Keysight, 5 years
R-50C-011-7Calibration Assurance Plan - Return to Keysight, 7 years
R-50C-011-10Calibration Assurance Plan - Return to Keysight, 10 years
Commercial calibration certificate
with test data
Commercial calibration certificate
with test data for M9300A
Service: 1-day start-up
assistance
Calibration certificate with
measurement results available
only at time of purchase.
Calibration certificate with
measurement results available
only at time of purchase.
Training on how to operate your
instrument effectively
Global warranty
Keysight provides the peace of mind that today’s high tech industry requires. Your
investment is protected by Keysight’s global reach in more than 100 countries (either
directly or through distributors). The warranty gives you convenient standard coverage
for the country in which the product is used, eliminating the need to ship equipment
back to the country of purchase. Keysight’s warranty service provides:
• All parts and labor necessary to return your investment to full specified performance
• Recalibration for products supplied originally with a calibration certificate
• Return shipment
1. For more information on MATLAB software, visit www.keysight.com/find/n6171a.
Page 8Find us at www.keysight.com
One day start-up assistance
A Keysight Technologies applications engineer will get you started quickly by helping
you install the modules in a chassis, configure the controller, load software and start
making measurements.
Calibration services
The modular products are factory calibrated and shipped with an ISO-9002, NIST-
traceable calibration certificate. A one year calibration cycle is recommended.
Upgrading Your System
Your product can be easily upgraded after the initial purchase. Fast license-key
upgrades for performance options that do not require additional hardware:
1. Contact your Keysight representative to place an order for an option upgrade.
2. You will receive your hardware entitlement certificate via email.
3. Redeem the certificate online by following the instructions provided to receive a
license key file.
4. Install the license key file using the Keysight License Manager.
5. Begin using the new capability
1, 2
.
DescriptionUpgrade number (x = 0 or 1)
Bandwidth upgrade, 300 MHz to 600 MHzM941xAU-B6X
Bandwidth upgrade, 300 MHz to 1.2 GHzM941xAU-B12
Bandwidth upgrade, 600 MHz to 1.2 GHzM941xAU-BU1
Memory upgrade, 256 MSa to 512 MSaM941xAU-M05
Add high output powerM941xAU-1EA
Add half duplex portM941xAU-HDX
Timing synchronization for MIMOM941xAU-MMO
Multi-tester synchronization across chassisM941xAU-MTS
Phase coherenceM941xAU-PHC
1. At the time of manufacture, the hardware related to many of these options was fully adjusted and
the option performance was verified to be within its warranted specifications. Within one year of
the initial calibration date of the analyzer, this option is fully calibrated with no further adjustment
or verification testing.
2. If this transceiver has been adjusted as part of a repair or calibration during its first year, or if
the transceiver is more than one year old, additional adjustment and performance verification
tests are required to ensure that some newly installed options are functioning properly. However,
the completion of these tests does not guarantee that the transceiver meets all warranted
specifications.
Page 9Find us at www.keysight.com
Using a Non-Keysight Chassis
The M9410A and M9411A VXT PXIe vector transceiver can be successfully installed in a
non-Keysight PXI chassis. Please use the following guidelines.
• Ensure that the chassis has enough consecutive PXIe or PXI-H slots to
accommodate the M9410A or M9411A.
• Ensure that the chassis and controller support peer-to-peer PXI Express I/O switch
topology.
• Ensure that controller selected is compatible with chassis.
Please contact your Keysight representative for more detailed information. For technical
assistance with non-Keysight equipment, please refer to the equipment manufacturer’s
website.
Related Literature
For more detailed product and specification information refer to the following literature
and web pages:
Publication titlePublication number
M9018B and M9019A PXIe 18-slot chassis - Data Sheet5992-1481EN
M9037A PXIe Embedded Controller - Data Sheet5991-3661EN