duced in any form or by any means
(including electronic storage and
retrieval or translation into a foreign
language) without prior agreement and
written consent from Keysight Technologies as governed by United States and
international copyright laws.
Manual Part Number
M9260-90000
Edition
Edition 3, May 2018
Printed in:
Printed in Malaysia
Published by:
Keysight Technologies
Bayan Lepas Free Industrial Zone,
11900 Penang, Malaysia
Technology Licenses
The hard ware and/or software
described in this document are furnished under a license and may be
used or copied only in accordance with
the terms of such license.
Declaration of Conformity
Declarations of Conformity for this
product and for other Keysight products may be downloaded from the
Web. Go to http://www.keysight.com/
go/conformity. You can then search by
product number to find the latest Declaration of Conformity.
U.S. Government Rights
The Software is “commercial computer
software,” as defined by Federal Acquisition Regulation (“FAR”) 2.101. Pursuant to FAR 12.212 and 27.405-3 and
Department of Defense FAR Supplement (“DFARS”) 227.7202, the U.S.
government acquires commercial computer software under the same terms
by which the software is customarily
provided to the public. Accordingly,
Keysight provides the Software to U.S.
government customers under its standard commercial license, which is
embodied in its End User License
Agreement (EULA), a copy of which can
be found at http://www.keysight.com/
find/sweula. The license set forth in the
EULA represents the exclusive authority
by which the U.S. government may use,
modify, distribute, or disclose the Software. The EULA and the license set
forth therein, does not require or permit, among other things, that Keysight:
(1) Furnish technical information
related to commercial computer software or commercial computer software
documentation that is not customarily
provided to the public; or (2) Relinquish
to, or otherwise provide, the government rights in excess of these rights
customarily provided to the public to
use, modify, reproduce, release, perform, display, or disclose commercial
computer software or commercial computer software documentation. No
additional government requirements
beyond those set forth in the EULA
shall apply, except to the extent that
those terms, rights, or licenses are
explicitly required from all providers of
commercial computer software pursuant to the FAR and the DFARS and are
set forth specifically in writing elsewhere in the EULA. Keysight shall be
under no obligation to update, revise or
otherwise modify the Software. With
respect to any technical data as
defined by FAR 2.101, pursuant to FAR
12.211 and 27.404.2 and DFARS
227.7102, the U.S. government
acquires no greater than Limited Rights
as defined in FAR 27.401 or DFAR
227.7103-5 (c), as applicable in any
technical data.
Warranty
THE MATERIAL CONTAINED IN THIS
DOCUMENT IS PROVIDED “AS IS,”
AND IS SUBJECT TO BEING
CHANGED, WITHOUT NOTICE, IN
FUTURE EDITIONS. FURTHER, TO THE
MAXIMUM EXTENT PERMITTED BY
APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRANTIES, EITHER
EXPRESS OR IMPLIED, WITH REGARD
TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. KEYSIGHT
SHALL NOT BE LIABLE FOR ERRORS
OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION
WITH THE FURNISHING, USE, OR
PERFORMANCE OF THIS DOCUMENT
OR OF ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT
AND THE USER HAVE A SEPARATE
WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT
CONFLICT WITH THESE TERMS, THE
WARRANTY TERMS IN THE SEPARATE
AGREEMENT SHALL CONTROL.
Safety Information
A CAUTION notice denotes a hazard. It
calls attention to an operating procedure, practice, or the like that, if not
correctly performed or adhered to,
could result in damage to the product
or loss of important data. Do not proceed beyond a CAUTION notice until
the indicated conditions are fully
understood and met.
A WARNING notice denotes a hazard. It
calls attention to an operating procedure, practice, or the like that, if not
correctly performed or adhered to,
could result in personal injury or death.
Do not proceed beyond a WARNING
notice until the indicated conditions are
fully understood and met.
2Keysight M9260A Startup Guide
Safety Symbols
WARNING
The following symbol on the instrument and in the documentation indicate
precautions which must be taken to maintain safe operation of the instrument.
Caution, risk of danger (refer to this manual for specific Warning or Caution information)
Safety Considerations
Read the information below before using this instrument.
The following general safety precautions must be observed during all phases of
operation, service, and repair of this instrument. Failure to comply with these
precautions or with specific warnings elsewhere in this manual violates safety
standards for design, manufacture, and intended use of the instrument. Keysight
Technologies assumes no liability for the customer’s failure to comply with these
requirements.
Keysight M9260A Startup Guide3
– If this product is not used as specified, the protection provided by the
equipment could be impaired. This product must be used in a normal
condition (in which all means for protection are intact) only.
– No operator serviceable inside. Refer servicing to qualified personnel. To
prevent electrical shock do not remove covers.
– To prevent electrical shock, disconnect the Keysight Technologies
instrument from mains before cleaning. Use a dry cloth or one slightly
dampened with water to clean the external case parts. Do not attempt to
clean internally. To clean the connectors, use alcohol in a well ventilated
area. Allow all residual alcohol moisture to evaporate, and the fumes to
dissipate prior to energizing the instrument.
CAUTION
– To maintain protection from electric shock and fire, replacement
components in mains circuits - including the power transformer, test
leads, and input jacks - must be purchased from Keysight. Standard fuses
with applicable national safety approvals may be used if the rating and
type are the same. Other components that are not safety-related may be
purchased from other suppliers as long as they are equivalent to the
original component (note that selected parts should be purchased only
through Keysight to maintain accuracy and functionality of the product).
If you are unsure about the applicability of a replacement component, call
a Keysight office for information.
– The maximum working voltage for the
M9260A input port is ±46 Vp while
the output port can only source up to ±10 Vp. Do not exceed the
maximum
M9260A input voltage to prevent damage to the module.
4Keysight M9260A Startup Guide
Environmental Conditions
The M9260A is designed for indoor use and in an area with low condensation. The
table below shows the general environmental requirements for this instrument.
Environmental conditionRequirement
Temperature
Humidity
AltitudeUp to 3000 m
Pollution degree2
Operating condition
– 0 °C to 55 °C
Storage condition
– –40 °C to 71 °C
Operating condition
– Up to 95% RH at 40 °C (non-condensing)
Storage condition
– Up to 90% RH at 65 °C (non-condensing)
Keysight M9260A Startup Guide5
Regulatory Information
The M9260A complies with the following safety and Electromagnetic
Compatibility (EMC) compliances:
Safety compliance
IEC 61010-1/EN 61010-1
EMC compliance
– IEC 61326-1/EN 61326-1 (Immunity for industrial electromagnetic
environment)
– Canada: ICES/NMB-001: Issue 4, June 2006
– Australia/New Zealand: AS/NZS CISPR 11
Supplementary information:
– The product was tested in a typical configuration with Keysight Technologies
test systems.
– This is a sensitive measurement apparatus by design and may have some
performance loss when exposed to ambient continuous electromagnetic
phenomenon.
6Keysight M9260A Startup Guide
South Korean Class A EMC declaration:
Information to the user:
This equipment has been conformity assessed for use in business environments. In
a residential environment this equipment may cause radio interference.
– This EMC statement applies to the equipment only for use in business
environment.
사 용 자 안 내 문
이 기기는 업무용 환경에서 사용할 목적으로 적합성평가를 받은 기기로서 가
정용 환경에서 사용하는 경우 전파간섭의 우려가 있습니다 .
– 사용자 안내문은 “ 업무용 방송통신기자재 ” 에만 적용한다 .
For Class B equipment there is no current statement required.
Keysight M9260A Startup Guide7
Regulatory Markings
The CE mark is a registered trademark
of the European Community. This CE
mark shows that the product complies
with all the relevant European Legal
Directives.
ICES/NMB-001 indicates that this ISM
device complies with the
Canadian ICES-001.
Cet appareil ISM est conforme a la
norme NMB-001 du Canada.
ISM GRP.1 Class A indicates that this
is an Industrial Scientific and Medical
Group 1 Class A product.
This symbol is a South Korean Class A
EMC Declaration. This is a Class A
instrument suitable for professional
use and in electromagnetic
environment outside of the home.
This symbol indicates the time period
during which no hazardous or toxic
substance elements are expected to
leak or deteriorate during normal use.
Forty years is the expected useful life
of the product.
The RCM mark is a registered
trademark of the Australian
Communications and Media Authority.
This instrument complies with the
WEEE Directive (2002/96/EC) marking
requirement. This affixed product label
indicates that you must not discard
this electrical or electronic product in
domestic household waste.
8Keysight M9260A Startup Guide
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/
96/EC
This instrument complies with the WEEE Directive (2002/96/EC) marking
requirement. This affixed product label indicates that you must not discard this
electrical or electronic product in domestic household waste.
Product category
With reference to the equipment types in the WEEE directive Annex 1, this
instrument is classified as a “Monitoring and Control Instrument” product.
The affixed product label is as shown below.
Do not dispose in domestic household waste.
To return this unwanted instrument, contact your nearest Keysight Service Center,
or visit http://about.keysight.com/en/companyinfo/environment/takeback.shtml
for more information.
Sales and Technical Support
To contact Keysight for sales and technical support, refer to the support links on
the following Keysight websites:
– www.keysight.com/find/M9260A
(product-specific information and support, software and documentation
updates)
– www.keysight.com/find/assist
(worldwide contact information for repair and service)
Step 5: Verify the Operation of the M9260A Module 34
This chapter describes the inspection, installation, and verification of the M9260A
PXIe Audio Analyzer.
17
1Inspection, Installation, and Verification
Introduction
The purpose of this Startup Guide is to describe the processes of inspecting and
setting up the Keysight M9260A PXIe Audio Analyzer, installing the required
software, and verifying the basic operation of the M9260A module.
If you have any questions after reviewing this information, please contact your
local Keysight Technologies representative or contact us through our website at
http://www.keysight.com/find/M9260A.
Related documentation
The Keysight M9260A PXIe Audio Analyzer documentation listed below can be
downloaded for free through our website at http://www.keysight.com/find/
M9260A. You can check the manual revision on the second page of each manual.
– Keysight M9260A PXIe Aud io Analyzer Data Sheet.
– Keysight M9260A PXIe Aud io Analyzer Service Guide.
18Keysight M9260A Startup Guide
Inspection, Installation, and Verification1
CAUTION
Step 1: Unpack and Inspect the Module
The M9260A PXIe Audio Analyzer is shipped in materials which prevent
damage from static. The module should only be removed from the packaging
in an anti-static area after ensuring that correct anti-static precautions are
taken. Store all modules in anti-static envelopes when not in use.
ESD precaution
Electrostatic discharge (ESD) can damage or destroy electronic components. All
work on electronic assemblies should be performed at a static-safe work station.
The following are the recommended ESD accessories and can be purchased from
your local supplier.
– Conductive table mat with wrist-strap combination.
– Conductive floor mat with heel-strap combination.
Both types, when used together, provide a significant level of ESD protection. Of
the two, only the table mat with wrist-strap combination provides adequate ESD
protection when used alone. To ensure user safety, the static-safe accessories
must provide at least 1 Ω of isolation from ground.
Figure 1-1 shows an example of a static-safe work station using both types of ESD
protection: conductive table mat with wrist-strap combination, and conductive
floor mat with heel-strap combination.
Keysight M9260A Startup Guide19
1Inspection, Installation, and Verification
WARNING
Figure 1-1Example of a static-safe work station
These techniques for a static-safe work station should not be used when
working on circuitry with a voltage potential greater than 500 V.
20Keysight M9260A Startup Guide
Inspect the module for damage
CAUTION
NOTE
Unpack the M9260A module from the shipping container. Keep the plastic port
protectors and the shipping container for possible reuse.
After unpacking the M9260A module, carefully inspect the unit for any shipping
damage. Report any damage to the shipping agent immediately, as such damage
is not covered by the warranty.
The warranty also does not cover:
– Damage from contamination
– Normal wear and tear of mechanical components
–Manuals or fuses
To avoid damage when handling the M9260A module, do not touch the
exposed connector pins.
Information on preventing damage to your Keysight equipment can be found at
www.keysight.com/find/tips.
Inspection, Installation, and Verification1
Keysight M9260A Startup Guide21
1Inspection, Installation, and Verification
NOTE
Return the module for service
Should it become necessary to return the M9260A for repair or service, follow the
steps below:
1 Review the warranty information shipped with your product.
2 Contact Keysight to obtain a Return Material Authorization (RMA) and return
address. If you need assistance finding Keysight’s contact information, go to
www.keysight.com/find/assist (worldwide contact information for repair and
service) or refer to the Support information on the product website at
www.keysight.com/find/M9260A.
3 Write the following information on a tag and attach it to the defective M9260A.
– Name and address of owner. A P.O. box is not acceptable as a return
address.
– Product model number (for example, M9260A).
– Product serial number (for example, MYXXXXXXXX). The serial number
label is located on the side panel of the module. The serial number can also
be read from the Soft Front Panel interface, but only after the software is
installed.
– Description of failure or service required.
4 Carefully pack the module in its original ESD bag and packing carton. If the
original carton is not available, use bubble wrap or packing peanuts and place
the instrument in a sealed container and mark the container “FRAGILE”.
5 On the shipping label, write “ATTENTION REPAIR DEPARTMENT” and the RMA
number.
Refer to the product by its serial number and model number if any
correspondence is required.
22Keysight M9260A Startup Guide
Inspection, Installation, and Verification1
NOTE
Step 2: Verify the Shipment Contents
The following items are included in the M9260A shipment:
– M9260A PXIe Audio Analyzer module
– Certificate of Calibration
All software and product information files can be downloaded for free at
www.keysight.com/find/M9260A.
Keysight M9260A Startup Guide23
1Inspection, Installation, and Verification
Step 3: Install the Controller and Software
System requirements
The following table lists the minimum system requirements for Keysight IO
Libraries Suite and controllers. In general, any x86 or x64 (except Itanium)
architecture should work but there may be a significant decrease in performance if
the processor speed is below the minimum requirements.
Tab le 1-1System requirements
Operating system
Processor speed
Available memory2 GB minimum
Available hard-disk
[a]
space
Display Resolution1024 × 768
Input DeviceMouse or a compatible pointing device
Browser
ChassisA PXIe or PXI-H chassis peripheral slot
Embedded Controller
Remote Controller
[a] Because of the installation procedures, less memory may be required for the operation than is required for the
installation.
Windows
– 1.5 GHz (x86 and x64) or higher
– Itanium 64 is not supported
2 GB available hard-disk space
Microsoft
A Keysight embedded controller running one of the above operating systems.
Note: The embedded controller must be compatible with the Keysight chassis.
A desktop/laptop PC running one of the above operating systems and a Keysight interface cable
(e.g. Y1202) with PCIe (desktop) or ExpressCard (laptop) interface card.
®
7 SP1 (32 or 64-bit) or higher
®
Internet Explorer 7 or greater
24Keysight M9260A Startup Guide
Set up the controller
CAUTION
NOTE
The following steps describe setting up the remote controller:
1 Install a compatible PCIe adapter in the PC.
2 Connect your I/O peripherals (mouse, keyboard, and monitor) to the PC.
3 Connect a compatible interface cable (e.g. Keysight Y1202) from the PC to the
PXIe chassis.
4 Power up the PXIe chassis.
5 Power up the PC and install the PCIe adapter drivers.
– During startup, power up the chassis before you power up the PC.
– During shutdown, power down the PC before you power down the
chassis.
The following steps describe setting up the embedded controller:
1 Install the embedded controller module into a compatible PXIe chassis.
2 Connect your I/O peripherals (mouse, keyboard, and monitor) to the
embedded controller module.
Inspection, Installation, and Verification1
3 Power up the PXIe chassis.
Do not install the M9260A module in the PXIe chassis yet. The software must be
installed first to allow the Keysight IO Libraries Connection Expert software to
detect the M9260A module.
Keysight M9260A Startup Guide25
1Inspection, Installation, and Verification
NOTE
Install the software
Install the software for the M9260A PXIe Audio Analyzer. The latest software
revision can be downloaded for free at www.keysight.com/find/M9260A.
The M9260A software consists of the following:
– Keysight IO Libraries Suite (IOLS), which includes the Keysight Connection
Expert.
– Soft Front Panel (SFP), device drivers (IVI-C,IVI-COM, LabVIEW G), and related
user documentation for the M9260A.
Every PXIe module comes with its own device driver (IVI-C, IVI-COM,
LabVIEW G), and soft front panel (SFP) software.
1 Download and launch the M9260A software installer.
2 Follow the installer prompts to install all software and documentation for the
M9260A PXIe Audio Analyzer.
26Keysight M9260A Startup Guide
Inspection, Installation, and Verification1
Figure 1-2InstallShield Wizard for Keysight M9260A
3 Once installation is complete, power down the PC and the PXIe chassis.
Keysight M9260A Startup Guide27
1Inspection, Installation, and Verification
CAUTION
NOTE
Step 4: Install the Module
– The PXIe hardware does not support “hot-swapping” capabilities
(changing modules while power is applied to the chassis).
– Before installing the
M9260A module into the chassis, ensure that the
chassis is powered off and unplugged to prevent damage to the module.
The M9260A module can be used in a chassis with a PXIe or PXI-H chassis
peripheral slot.
The module can be installed in any PXIe slot marked with a peripheral slot
compatibility image (a solid circle containing the slot number).
The module can also be installed in any hybrid PXI slot marked with a
peripheral slot compatibility image (the letter “H” and a solid circle containing
the slot number).
1 Ensure that the PXIe chassis power switch is at the Off (Standby) position and
the chassis power cable is unplugged.
2 If the chassis has multiple fan speed settings, ensure that the fans are set to
automatic. Do not set the fan speed to low or turn it off.
3 Position the chassis so that there is ample space between the chassis fan
intake and exhaust vents. Blockage by walls or obstructions affect the air flow
needed for cooling. (Refer to the chassis documentation for more information
about cooling).
28Keysight M9260A Startup Guide
Inspection, Installation, and Verification1
Figure 1-3Installing the module to the chassis
4 Hold the module by the injector/ejector handle, and slide it into an available
PXIe or hybrid slot, as shown in Figure 1-3.
– Install the module into the PXIe slot of the chassis by placing the module
card edges into the front module guides (top and bottom).
– Slide the module to the rear of the chassis and ensure that the injector/
ejector handle is pushed down in the unlatched (downward) position.
– Slide the module completely into the chassis.
– When you begin to feel resistance, push up on the injector/ejector handle
to fully seat the module into the chassis.
5 Latch the module by pulling up on the injector/ejector handle and secure the
front panel to the chassis using the module front-panel mounting screws.
6 Tighten the screws on the module front panel. Performance may suffer if the
screws are not tightened properly.
Keysight M9260A Startup Guide29
1Inspection, Installation, and Verification
WARNING
7 Verify that the PXIe chassis fans are operable and free of dust that may restrict
airflow.
8 Install all chassis covers and filler panels after installing the module. Missing
filler panels may disrupt necessary air circulation in the chassis.
9 Plug in the power cable and power up the PXIe chassis.
Tighten the screws on the module front panel. Protection provided by the
equipment could be impaired if the screws are not tightened properly.
30Keysight M9260A Startup Guide
Inspection, Installation, and Verification1
Module installation procedures
1 Press down the ejector.
2 Slide the M9260A module into any
slot until the backplane connectors
touch.
3 Seat the M9260A module into the
chassis by pulling up the ejector.
4 Tighten the top and bottom screws
to secure the M9260A module to the
chassis.
Figure 1-4Module installation procedures
Keysight M9260A Startup Guide31
1Inspection, Installation, and Verification
M9260A front panel
Figure 1-5M9260A PXIe Audio Analyzer front panel
32Keysight M9260A Startup Guide
Inspection, Installation, and Verification1
M9260A audio analyzer functional block diagram
Figure 1-6M9260A functional block diagram
Keysight M9260A Startup Guide33
1Inspection, Installation, and Verification
Step 5: Verify the Operation of the M9260A Module
The purpose of the verification procedure for the M9260A is to ensure that the
module is operating within its specifications.
The verification procedure is run using the M9260A Soft Front Panel (SFP)
software included with this product. Launch the M9260A SFP by clicking its
desktop shortcut icon or by clicking:
The M9260 SFP module selection interface will display all modules that are
connected and installed. Review the configuration data and launch the M9260A
SFP.
The M9260A SFP will provide control over the module for operational verification
procedures. A screen capture of the SFP interface is shown in Figure 1-7.
Figure 1-7M9260A SFP interface
34Keysight M9260A Startup Guide
Inspection, Installation, and Verification1
NOTE
– The SFP can be used as a learning tool to help you experience the module's
capability and behavior through an easy-to-use GUI.
– Refer to the Keysight M9260A Soft Front Panel Help for details on how to use
the SFP software.
Conduct operational verification (optional)
The verification procedure in this section helps to ensure the M9260A module is
operational. No external equipment is required except for two BNC to BNC cables
to enable loopback configuration from the audio generator outputs to the audio
analyzer inputs.
M9260A operational verification procedure
The M9260A verification procedure involves measuring the Vac, Frequency,
THD+N, and THD parameters. The average value from the measured data samples
will then be calculated. The measurement results (average) are then compared to
the known values output from the audio generator.
1 Launch the M9260A Soft Front Panel (SFP).
2 Connect the Generator CH1 output to the Analyzer CH1 input, and the
Generator CH2 output to the Analyzer CH2 input using BNC cables as shown
in Figure 1-8.
Keysight M9260A Startup Guide35
1Inspection, Installation, and Verification
Figure 1-8Connecting the BNC-BNC cables from the generator outputs to
the analyzer inputs
3 Configure the M9260A PXIe Audio Analyzer using the SFP based on the
settings in the following table and figures.
36Keysight M9260A Startup Guide
Inspection, Installation, and Verification1
Table 1-2Configuration for M9260A audio analyzer
FunctionParameterSetting
Analog Generator
Analog Analyzer
Channels
Impedance50 Ω
OutputDifferential
WaveformSine
Amplitude1 Vp
Frequency1 kHz
DC Offset0 V
Channels
Range1 Vp
ConnectionBNC
InputDifferential
Impedance1 MΩ
CouplingDC
Sample Size32768
Sampling Rate192 kHz
Function 1AC
1 & 2 (Configure one channel at a
time)
1 & 2 (Configure one channel at a
time)
Function 2Frequency
Function 3THDN-Ratio
Measurement
Function 4THD-Ratio
Low Pass Filter (LPF)20 kHz
High Pass Filter (HPF)20 Hz
WeightingNone
Keysight M9260A Startup Guide37
1Inspection, Installation, and Verification
Figure 1-9Configuring the Analog Generator
Figure 1-10Configuring the Analog Analyzer
38Keysight M9260A Startup Guide
Inspection, Installation, and Verification1
Figure 1-11Configuring the Measurement
4 On the Analog Generator tab, turn on the generator by clicking Generator: Off
so that it becomes Generator: On.
5 On the Acquire section, select Continuous to initiate the audio analyzer to
acquire data and perform the measurement. The results will be displayed
under the Measurement Function Result section. Figure 1-12 shows the
Acquire and Measurement Function Result section.
Figure 1-12Initiating M9260A audio analyzer data acquisition
Keysight M9260A Startup Guide39
1Inspection, Installation, and Verification
6 Compare the measured values to the accuracy values as stipulated in
Tabl e 1-3.
7 Repeat Step 3 to Step 6 using different output amplitude and input range
values for all voltage ranges and channels. Refer to Tab le 1-3 for the
suggested output amplitude and input range values.