Keysight Technologies M9037A Startup Manual

Page 1

Startup Guide

Keysight M9037A PXIe Embedded Controller

Page 2
Page 3
Notices
© Keysight Technologies, Inc. 2014
No part of this manual may be repro­duced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written con­sent from Keysight Technologies, Inc. as governed by United States and interna­tional copyright laws.
Manual Part Number
M9037-90001
Edition
Third Edition, September 2014 Printed in Malaysia
Keysight Technologies, Inc. 1400 Fountaingrove Parkway Santa Rosa, CA 95403 USA
Trademarks
AXIe is a registered trademark of the AXIe Consortium.
PXI is a registered trademark of the PXI Systems Alliance.
®
PICMG AdvancedTCA marks of the PCI Industrial Computer Manufacturers Group.
PCI-SIG registered trademarks of PCI-SIG.
, Compact PCI®, and
®
are registered trade-
®
, PCI Express®, and PCIe
®
are
Sales and Technical Support
To contact Keysight for sales and techni­cal support, refer to the support links on the following Keysight websites:
www.keysight.com/find/M9037A (prod-
uct-specific information and support, software and documentation updates)
www.keysight.com/find/assist (world-
wide contact information for repair and service)
Information on preventing damage to your Keysight equipment can be found at
www.keysight.com/find/tips.
Declaration of Conformity
Declarations of Conformity for this prod­uct and for other Keysight products may be downloaded from the Web. Go to
http://keysight.com/go/conformity and
click on “Declarations of Conformity.” You can then search by product number to find the latest Declaration of Conformity.
T
echnology Licenses
The hard ware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.
Warranty
THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED “AS IS,” AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDI­TIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WAR­RANTIES, EITHER EXPRESS OR IMPLIED, WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MER­CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCUMENT OR OF ANY INFOR­MATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEP­ARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT SHALL CONTROL.
Keysight Technologies does not warrant third-party system-level (combination of chassis, controllers, modules, etc.) per­formance, safety, or regulatory compli­ance unless specifically stated.
DFARS/Restricted Rights Notices
If software is for use in the performance of a U.S. Government prime contract or subcontract, Software is delivered and licensed as “Commercial computer soft­ware” as defined in DFAR 252.227-7014 (June 1995), or as a “commercial item” as defined in FAR 2.101(a) or as “Restricted computer software” as defined in FAR
52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Keysight Technologies’ stan­dard commercial license terms, and non­DOD Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR
52.227-19(c)(1-2) (June 1987). U.S. Gov­ernment users will receive no greater than Limited Rights as defined in FAR
52.227-14 (June 1987) or DFAR 252.227­7015 (b)(2) (November 1995), as applica­ble in any technical data.
Page 4
Safety Information
The following general safety precau­tions must be observed during all phases of operation of this instrument. Failure to comply with these precau­tions or with specific warnings or oper­ating instructions in the product manuals violates safety standards of design, manufacture, and intended use of the instrument. Keysight Technolo­gies assumes no liability for the cus­tomer's failure to comply with these requirements.
General
Do not use this product in any manner not specified by the manufacturer. The protec­tive features of this product must not be impaired if it is used in a manner specified in the operation instructions.
Before Applying Power
Verify that all safety precautions are taken. Make all connections to the unit before applying power. Note the external markings described under “Safety Symbols”.
Ground the Instrument
Keysight chassis’ are provided with a grounding-type power plug. The instrument chassis and cover must be connected to an electrical ground to minimize shock hazard. The ground pin must be firmly connected to an electri­cal ground (safety ground) terminal at the power outlet. Any interruption of the protective (grounding) conductor or disconnection of the protective earth terminal will cause a potential shock hazard that could result in per­sonal injury.
Do Not Operate in an Explosive Atmosphere
Do not operate the module/chassis in the presence of flammable gases or fumes.
Do Not Operate Near Flammable Liquids
Do not operate the module/chassis in the presence of flammable liquids or near containers of such liquids.
Cleaning
Clean the outside of the Keysight mod­ule/chassis with a soft, lint-free, slightly dampened cloth. Do not use detergent or chemical solvents.
Do Not Remove Instrument Cover
Only qualified, service-trained person­nel who are aware of the hazards involved should remove instrument covers. Always disconnect the power cable and any external circuits before removing the instrument cover.
Keep away from live circuits
Operating personnel must not remove equipment covers or shields. Proce­dures involving the removal of covers and shields are for use by service­trained personnel only. Under certain conditions, dangerous voltages may exist even with the equipment switched off. To avoid dangerous elec­trical shock, DO NOT perform proce­dures involving cover or shield removal unless you are qualified to do so.
DO NOT operate damaged equipment
Whenever it is possible that the safety protection features built into this prod­uct have been impaired, either through physical damage, excessive moisture, or any other reason, REMOVE POWER and do not use the product until safe operation can be verified by service­trained personnel. If necessary, return the product to an Keysight Technolo­gies Sales and Service Office for ser­vice and repair to ensure the safety features are maintained.
DO NOT block the primary disconnect
The primary disconnect device is the appliance connector/power cord when a chassis used by itself, but when installed into a rack or system the dis­connect may be impaired and must be considered part of the installation.
Do Not Modify the Instrument
Do not install substitute parts or per­form any unauthorized modification to the product. Return the product to an Keysight Sales and Service Office to ensure that safety features are main­tained.
In Case of Damage
Instruments that appear damaged or defective should be made inoperative and secured against unintended oper­ation until they can be repaired by qualified service personnel
Do NOT block vents and fan exhaust: To ensure adequate cooling and venti­lation, leave a gap of at least 50mm (2") around vent holes on both sides of the chassis.
Do NOT operate with empty slots: To ensure proper cooling and avoid dam­aging equipment, fill each empty slot with an AXIe filler panel module.
Do NOT stack free-standing chassis: Stacked chassis should be rack­mounted.
All modules are grounded through the chassis: During installation, tighten each module's retaining screws to secure the module to the chassis and to make the ground connection.
Operator is responsible to maintain safe operating conditions. To ensure safe operating conditions, modules should not be operated beyond the full temperature range specified in the Environmental and physical specifica­tion. Exceeding safe operating condi­tions can result in shorter lifespan, improper module performance and user safety issues. When the modules are in use and operation within the specified full temperature range is not maintained, module surface tempera­tures may exceed safe handling condi­tions which can cause discomfort or burns if touched. In the event of a module exceeding the full temperature range, always allow the module to cool before touching or removing modules from the chassis.
iv
Page 5
Safety Symbols
A CAUTION denotes a hazard. It calls attention to an operating pro­cedure or practice, that, if not cor­rectly performed or adhered to could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated condi­tions are fully understood and met.
A WARNING denotes a hazard. It calls attention to an operating pro­cedure or practice, that, if not cor­rectly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indi­cated conditions are fully under­stood and met.
Products display the following sym­bols:
Warning, risk of electric shock
Refer to manual for addi­tional safety information.
Earth Ground.
Chassis Ground.
Alternating Current (AC).
Standby Power. Unit is not completely disconnected from AC mains when switch is in standby.
Antistatic precautions should be taken.
The CSA mark is a registered trade­mark of the Canadian Standards Asso­ciation and indicates compliance to the standards laid out by them. Refer to the product Declaration of Confor­mity for details.
Notice for European Community: This product complies with the relevant European legal Directives: EMC Direc­tive (2004/108/EC) and Low Voltage Directive (2006/95/EC).
The Regulatory Compliance Mark (RCM) mark is a registered trademark. This signifies compliance with the Aus­tralia EMC Framework regulations under the terms of the Radio Commu­nication Act of 1992.
ICES/NMB-001 indicates that this ISM device complies with the Canadian ICES-001.
This symbol represents the time period during which no hazardous or toxic substance elements are expected to leak or deteriorate during normal use. Forty years is the expected useful life of this product.
South Korean Class A EMC Declara­tion. this equipment is Class A suitable for professional use and is for use in electromagnetic environments outside of the home.
Waste Electrical and
Electronic Equipment (WEEE) Directive 2002/96/EC
This product complies with the WEEE Directive (2002/96/EC) marking requirement. The affixed product label (see below) indicates that you must not discard this electrical/electronic prod­uct in domestic household waste.
Product Category: With reference to the equipment types in the WEEE directive Annex 1, this product is clas­sified as a “Monitoring and Control instrumentation” product.
Do not dispose in domestic household waste.
To return unwanted products, contact your local Keysight office, or see
www.keysight.com/environment/prod­uct for more information.
CAT I CAT II CAT III CAT IV
For localized Safety Warnings, Refer to Keysight Safety document (p/n 9320-6792).
IEC Measurement Cate­gory I, II, III, or IV
v
Page 6
vi
Page 7

Contents

Documentation Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
M9037A at a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Front panel LED indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
LAN RST Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Step 1: Unpack and Inspect the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ESD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Inspect for damage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
If you need to return the module for service . . . . . . . . . . . . . . . . . . . . . . . . 10
Step 2: Verify Shipment Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Step 3: Install the M9037A Embedded Controller . . . . . . . . . . . . . . . . . . . . . . 12
Removing the M9037A from the chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Power On Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Power Off Sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Power Down Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Activating Microsoft Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
How to verify Windows Activation?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Controller and Chassis Drivers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Windows Security. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
User data backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
System Backup and Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Step 4: Run Keysight IO Libraries Suite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Step 5. Verify Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Step 6: Install User Application Modules in the PXIe Chassis . . . . . . . . . . . . . 20
Install application module drivers (if necessary) . . . . . . . . . . . . . . . . . . . . . 20
Upgrading from the M9036A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Controller Operating System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Windows security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
User data backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Chassis shutdown. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
M9018A PCIe Link Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Using LabVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
M9037A Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Environmental Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Keysight M9037A PXIe Embedded Controller Startup Guide iv
Page 8

Documentation Map

Product theory of operation Configuration Self test Field calibration Error reports
IVI-COM and IVI-C driver programmer’s reference
LabVIEW driver programmer’s reference
Detailed config\ operating instructions
SFP help system
CD
IVI Driver help system
with link to detailed VI
information
Description Technical specifications
Install software
hardware Verify operation
Service Guide
x Security Guide x Specification
Pres
s
ith
focus on Metho
d
Product
Product web
Startup Guide
site
Access to all DOCUMENTATION noted below
Startup Guide
x x Install & connect
x
Soft Front Panel (SFP) user interface
Visual Studio
Press F1 with
F1w
focus on Method
LabVIEW
User Guide
x
Data Sheet
x Product
x
x
x x x x
LabVIEW Driver help system
Other Manuals
x
Guide
x
x
Context Help
v Keysight M9037A PXIe Embedded Controller Startup Guide
Page 9

Introduction

M9037A PXIe Embedded Controller Startup Guide
Keysight’s M9037A is a 3U, 4-slot PXIe Embedded Controller providing:
- Intel Haswell Core
- 4 GB standard (or optional 8 or 16 GB) 1600 MHz DDR3 Memory
- 240 GB SATA 2.5 inch solid state drive (SSD) front panel removable
TM
i7-4700EQ quad-core, 2.4 GHz processor
*
- Integrated IO on the front panel includes two Gigabit Ethernet ports, four USB
2.0 ports
, two USB 3.0 ports, GPIB connector, two DisplayPort video ports
(also known as DisplayPort++), one PCIe x8 connector
- Front Panel SMB Trigger Connector used to route an external trigger signal (TTL level) to/from the PXI backplane with software trigger
- Preloaded with Keysight IO Libraries and your choice of either Microsoft Windows Embedded Standard 7 (WES7) 32-bit or 64-bit Operating System
- Pre-installed IVI drivers for the Keysight M9018A 18-slot PXIe chassis

Related Documentation

A Windows Embedded Standard 7 (WES7) Operating System and all M9037A drivers were installed at the factory, no additional drivers are required. This Startup Guide and an M9037A User Guide are also found on the Product Information CD supplied with the controller.
Complete M9037A documentation, as well as the M9018A PXIe chassis documentation, is available preinstalled on the M9037A SSD. From the Windows Start button, select All Programs > Keysight > M9037A or M9018A.
Adobe Reader is required to view the documentation supplied on the M9037A and product CD. It is available free at: http://www.adobe.com. You should instal l this on your M9037A prior to attempting to open a .PDF file.
For the latest M9037A specifications, go to: www.keysight.com/find/M9037A.
For the IVI trigger driver, help file, program examples, etc. go to:
C:\ProgramFiles\IVI Foundation\IVI\Drivers\AgPxiPc or C:\ProgramFiles x86\IVI Foundation\IVI\Drivers\AgPxiPc
For the Soft Front Panel interface: from the Window’s Start menu, select:
Start > All Programs > Keysight > PXIe Embedded Controller >
Embedded Controller SFP
* The M9037A has two 240-pin, RDIMM sockets that support DDR3-1600 REG/ECC RAM sticks. The standard
M9037A configuration is a single 4 GB memory module with a factory option to provide either 8 or 16 GB memory. A 32-bit OS system may not be able to address 4GB memory space. To use the full 16GB memory, a 64-bit OS must be used. The M9037A can address up to 32 GB total memory.
† The USB 2.0 and 3.0 ports do not support the USB Battery Charging specification. Do not connect
non-standard or defective USB devices
6
Page 10

M9037A at a Glance

DisplayPort Connectors
GPIB
USB 2.0 Ports*
SMB Trigger
LED Indicators
Connector
USB 3.0 Ports
PCIe Connector
Handle for
LAN (GbE) Port #1
LAN (GbE) Port #2
LAN Reset
PCIe Link Speed
Connector
(supports multiple monitors
Indicator
removing
button
The following figure shows the front panel for the M9037A. Detailed information about the module follows in this manual.
M9037A at a Glance
* The USB 2.0 and 3.0 ports do not support the USB Battery Charging specification. Do not connect non-standard or defective USB devices.
7 Keysight M9037A PXIe Embedded Controller Startup Guide
Page 11
M9037A at a Glance
Speed and Link 10Mbps: off 100Mbps: Green 1000Mbps: Amber
Active Blinks when accessing IO
RJ-45 connector

Front panel LED indicators

The following table lists the LEDs on the front panel and a brief description of their use and what they indicate.
LED Indicator Color Description
PWR Green If the LED is on, the power supply to the controller is good
and the system should boot.
SSD Amber When the Solid State Drive (SSD) is active, the LED will
flash.
LAN N/A These two LEDS and the LAN RST switch are reserved for
USB N/A
PCIe Link Green Indicates PCIe Link Status:
Keysight use only. The LEDs should never turn on or flash. Depressing the LAN RST switch has no effect.
Off = no link; blinking @ 1 Hz rate = Gen1 speed blinking @ 2 Hz = Gen2 speed LED on steady = Gen3 speed
Gigabit Ethernet (GbE) LEDs
Status Speed LED
Network link is not established or system is powered off
Link Off ON
10 Mbps
100 Mbps
1000 Mbps
Active Off Blinking
Link Green ON
Active Green Blinking
Link Amber ON
Active Amber Blinking
LAN RST Switch
Activity LED
(Green/Amber)
OFF OFF
(Yellow)
The LAN RST switch is reserved for Keysight use only. Depressing the LAN RST switch has no effect.
Keysight M9037A PXIe Embedded Controller Startup Guide 8
Page 12

Step 1: Unpack and Inspect the Module

Keysight’s PXIe Modules are shipped in materials that prevent static electricity damage. The modules should only be removed from the packaging in an anti-static area ensuring that correct anti-static precautions are taken. Store all modules in anti-static envelopes when not in use.
ESD
Electrostatic discharge (ESD) can damage or destroy electronic components. All work on electronic assemblies should be performed at a static-safe work station. The following figure shows an example of a static-safe work station using two types of ESD protection. Purchase acceptable ESD accessories from your local supplier.
Step 1: Unpack and Inspect the Module
- Conductive table-mat and wrist-strap combination.
- Conductive floor-mat and heel-strap combination.
Both types, when used together, provide a significant level of ESD protection. Of the two, only the table-mat and wrist-strap combination provides adequate ESD protection when used alone. To ensure user safety, the static-safe accessories must provide at least 1 M of isolation from ground.

Inspect for damage

After unpacking the embedded controller, carefully inspect it for any shipping damage. Report any damage to the shipping agent immediately, as such damage is not covered by the warranty.
To avoid damage when handling a module; do not touch exposed connector pins.
Information on preventing damage to your Keysight equipment can be found at www.keysight.com/find/tips.
9 Keysight M9037A PXIe Embedded Controller Startup Guide
Page 13
Step 1: Unpack and Inspect the Module

If you need to return the module for service

Should it become necessary to return a Keysight module for repair or service, follow the steps below:
1 Review the warranty information shipped with your product.
2 Contact Keysight to obtain a return authorization and return address. If you
need assistance finding Keysight contact information go to
www.keysight.com/find/assist (worldwide contact information for repair and
service) or refer to the Support information on the product web page at:
www.keysight.com/find/M9037A.
3 Write the following information on a tag and attach it to the malfunctioning
equipment.
– Name and address of owner. A Post Office box is not acceptable as a return
address.
Product model number (for example, M9037A)
Product serial number (for example, TWXXXXXXXX). The serial number
label is located on the side of the module.
A description of failure or service required.
4 You should remove the SSD and RAM modules prior to returning the M9037A
for service. Refer to the M9037A User Guide for detailed instructions. The service center has its own SSD and RAM modules for testing purposes
5 Carefully pack the module in its original ESD bag and carton. If the original
carton is not available, use bubble wrap or packing peanuts, place the instrument in a sealed container and mark the container “FRAGILE”.
6 On the shipping label, write ATTENTION REPAIR DEPARTMENT and the
service order number (if known).
If any correspondence is required, refer to the product by model number and serial number.
Keysight M9037A PXIe Embedded Controller Startup Guide 10
Page 14

Step 2: Verify Shipment Contents

Your shipment should have included the following:
- The Keysight M9037A Embedded Controller module that you ordered.
- This printed manual (M9037A PXIe Embedded Controller Startup Guide).
- An Automation-Ready CD with Keysight IO Libraries Suite (version 16.3 or
later). (IO Libraries was installed at the factory)
- An M9037A Product Information CD with User Guide and specifications. Adobe Reader is required (http://www.adobe.com)
The operating system of your choice, either Microsoft Windows Embedded Standard 7 (WES7) 32-bit or 64-bit, the latest version of Keysight IO Libraries Suite, and all necessary driver software were installed for you at the factory.
The most current version of Keysight IO Libraries is required prior to installing and running any other software. The latest version can be downloaded from: www.keysight.com/find/iosuite.
Step 2: Verify Shipment Contents
No other drivers are required to operate the controller module. However, your application modules may require drivers. If possible, you should connect the M9037A to the internet and download drivers from the original source. Alternately, you can transfer the drivers on a USB memory stick and install them accordingly.
A GPIB cable is NOT supplied with the controller. Note that the GPIB cable is a standard micro type 2 GPIB cable with standard pin wiring and is not compatible with the M9036A Embedded Controller GP-IB cable. It is available from Keysight as an accessory cable, part number Y1260A.
11 Keysight M9037A PXIe Embedded Controller Startup Guide
Page 15

Step 3: Install the M9037A Embedded Controller

Ensure the M9018A backplane switch is in the left position
Step 3: Install the M9037A Embedded Controller
The Keysight M9037A has been designed for easy installation. However, the following standard precautions, installation procedures, and general information must be observed to ensure proper installation and to prevent damage to the board, other system components, or injury to personnel.
Keysight’s M9037A can operate with all of the PCIe fabric configurations found on the M9018A chassis as well as the standard 4x4 fabric used on non-Keysight PXIe chassis.
The following safety precautions must be observed when installing or operating the Keysight M9037A. Exercise care when handling the mod ule as the heat sink can get very hot. Do not touch the heat sink when installing or removing the module. The board should not be placed on any surface or in any form of storage container until the board and heat sink have cooled to room temperature.
Embedded controllers, such as the M9037A, must be installed in System Controller slot (Slot 1) of the chassis.
M9018A PXIe Chassis Backplane Switch:
The default position of the chassis backplane switch is to the left. However, if a Keysight M9021A Cable Interface module was previously installed in the M9018A chassis, then the backplane switch was moved to the right. To use the M9037A Embedded Controller in the M9018A chassis, the slide switch should be in the left position before installing the controller. Refer to the M9018A chassis documentation for more information.
Keysight M9037A PXIe Embedded Controller Startup Guide 12
Page 16
Step 3: Install the M9037A Embedded Controller
Remove these
chassis stops
Follow these steps to install the M9037A Embedded Controller in a PXIe chassis.
1 Ensure the PXIe chassis is turned off. The chassis should be plugged into an
AC power source; the AC power cord grounds the chassis and protects it from electrical damage while modules are installed.
Some non-Keysight PXIe chassis manufacturers install small chassis stops just to the left of the slot 1 guide rails (both top and bottom). Refer to the photo below. These must be removed prior to installing the M9037A Embedded Controller. They snap in and are easily pulled out.
2 On the M9018A chassis, set the rear panel INHIBIT switch to DEF.
3 Remove the screw protection caps from the four M9037A retaining screws.
4 Push down on the controller’s ejector/injector handle. The red button on the
handle must be depressed to release it.
5 Carefully align the M9037A board edges with the chassis guide rails for slot 1
(red guide rails) and insert the controller into the guide rails.
6 Push inward on the module until it is firmly seated in the chassis. (Do not force
the handle if there is resistance; this may damage the connectors and/or backplane.)
7 Pull up on the ejector/injector handle to firmly seat the controller.
8 Tighten the module’s four (4) captive retaining screws.
9 A slot blocker should be installed immediately to the left of the M9037A to
ensure proper airflow.
10 Connect other peripherals (such as the keyboard, mouse, monitor, LAN cable
for remote access, etc.) to the Embedded Controller.
11 Power up the PXIe chassis. Verify that the chassis fans are operating and free
of obstructions that may restrict air flow.
13 Keysight M9037A PXIe Embedded Controller Startup Guide
Page 17
Step 3: Install the M9037A Embedded Controller

Removing the M9037A from the chassis

To remove the M9037A controller, reverse the previous procedure. Execute the Windows shut down process on the controller first. Then power down the chassis. Loosen the four captive screws, press down on the ejector/injector handle and pull outwards to release the module from the backplane. Pull the module towards you until it is free of the chassis.

Power On Sequence

The M9037A controller, like any PC, will boot with the installed operating system. Refer to the M9037A User Guide for detailed power on and configuration sequence information.
Depending on the system configuration, the BIOS may take 90 seconds (or longer) to boot. During this time, the Keysight splash screen (the Keysight logo) is present and it may appear that nothing is happening. This is generally caused by the inclusion of certain devices in the switch fabric (such as RAID controller) that require a longer time for PCI enumeration.
The first time the M9037A is powered up, it will prompt you to create a user password.

Power Off Sequence

As with any PC, Windows-based instruments should not be shutdown by either turning off the power via an external power source or by pulling the power plug out from the rear panel. This could corrupt the operating system. The approved way to shut down the controller is to execute the Windows shutdown process which shuts down the M9037A controller then turns off the M9018A chassis. If the M9018A chassis rear panel INHIBIT switch is set to DEF then momentarily pressing the front panel button shuts down the M9037A safely.
Keysight M9037A PXIe Embedded Controller Startup Guide 14
Page 18

Power Down Modes

Keysight’s M9037A defaults to the Windows High Performance Power Plan. This plan does not allow the controller display to shut off or the controller to enter a sleep mode.
Step 3: Install the M9037A Embedded Controller
You should not enable the Microsoft Windows Sleep mode. It is possible that the M9037A controller could go into Sleep mode while it is running a user test program. The controller may not have proper chassis enumeration when it wakes up.
If you have a USB keyboard with a Sleep button (sometimes this is a key with a crescent moon logo), do not use it.
Do not use the Sleep or Hibernate modes from the Startup Button as shown in the following graphic.

Activating Microsoft Windows

Keysight ensures that your copy of Microsoft Windows Embedded Standard 7 (WES7) Operating System is activated at the time it ships from the factory. However, the first time you install and turn on the M9037A and Windows starts, you must accept the End User License Agreement (EULA). A copy of the EULA was included in your controller shipment. A copy of the EULA is included on your controller in the folder:
C:Windows\System32\en-US\Licenses\OEM\Professional\license.rtf
For information about Windows EULA, go to www.microsoft.com.
15 Keysight M9037A PXIe Embedded Controller Startup Guide
Page 19
Step 3: Install the M9037A Embedded Controller
How to verify Windows Activation?
To verify Windows Activation, do the following:
1 Open the System by clicking the Windows Start button. Click Control Panel,
then System.
2 Scroll down to the bottom of the screen. Under Windows Activation, you can
view the activation status.
By Keysight’s agreement with Microsoft, Windows Automatic Update is turned off at installation. You may choose to turn Windows Automatic Update on after starting the operating system. However, Keysight cannot be held responsible for changes to the system caused by the automatic update process. Enabling automatic Windows updates exposes the controller to periodic OS changes and possible new system behaviors.
Make certain the caps lock and num lock keys are off when entering passwords (especially for the first time). It is possible for these keys to be on when the controller powers on.

Controller and Chassis Drivers

All of the M9037A Controller and M9018A Chassis drivers were installed on your controller at the factory. You should not need to reinstall them. The M9037A Product Information CD you received as part of the initial shipment (see “Step 2:
Verify Shipment Contents” on page 11) provides a backup for the drivers.
However, you should periodically check the M9037A web page (www.keysight.com/find/M9037A) for the most current drivers. Instructions for updating the drivers are on the web.
If you already have a Keysight M9036A Embedded Controller and you want to upgrade to an M9037A, be aware that the IVI API drivers are not the same. You will need to update any programs/applications you have written and rebuild them.

Windows Security

If your system is connected to the internet, you should take the following steps to ensure the operating system is protected:
- Use an internet firewall
- Get the latest Windows updates
- Install and use up-to-date antivirus software.
Keysight M9037A PXIe Embedded Controller Startup Guide 16
Page 20
Step 3: Install the M9037A Embedded Controller
To check the status of, or make changes to, the security settings for your controller, open the Windows Security Center (Start > Control Panel > Security Center).
The default system setting is Windows Automatic Updates is turned off. You may want to manually update Windows OS by accessing Internet Explorer and from the Tools menu, select Windows Update.
Downloading and installing Windows Updates can be network and CPU intensive (impacting system performance) and some Windows Updates automatically reboot the controller. Therefore, Windows updates should be performed when the system is not in normal use.
There is no antivirus or spyware software included with your controller. Antivirus application software is the customer's responsibility. Having antivirus software installed my have a slight impact on system performance if your system uses intensive network data transfer.

User data backup

All user data should be regularly backed up to an external memory device. This can be done across a network or to a USB device. Your IT department may already have a backup strategy which is suitable for the system and data. Also, user data back up should be done just prior to sending the controller back to Keysight for service.

System Backup and Recovery

Microsoft Windows Embedded Standard 7 (WES7) 32-bit or 64-bit Operating System is the only operating system installed on your M9037A. There is a small system partition for the Keysight Recovery System on the SSD. During the boot process, you are given the choice to boot to Windows 7 normally or boot from the recovery partition. Refer to the M9037A User Guide for detailed information.
Some third-party disk backup utilities may destroy the Keysight backup partition. If this happens, the Keysight Recovery System will not work.
17 Keysight M9037A PXIe Embedded Controller Startup Guide
Page 21

Step 4: Run Keysight IO Libraries Suite

Step 4: Run Keysight IO Libraries Suite
Keysight IO Libraries Suite 16.3 Update 2 (or later) was installed at the factory in your embedded controller. If you need to re-install it or want to update to a later version, follow the instructions below. It includes the Keysight Connection Expert, the IVI Shared Components, and the VISA Shared Components.
IVI drivers are installed in:
C:\ProgramFiles\IVI Foundation\IVI\Drivers\AgPxiPc
or
C:\ProgramFiles x86\IVI Foundation\IVI\Drivers\AgPxiPc
Keysight IO Libraries version 16.3 Update 2 (or later) was pre-installed at the factory. The latest version can be downloaded from: www.keysight.com/find/iosuite.
Keysight IO Libraries installs the IVI Shared Components and VISA Shared Components on your controller.
If Connection Expert is not already running, run it now to verify your I/O configuration. From the Windows Start button, select All Programs > Keysight IO Libraries Suite > Keysight Connection Expert. Alternately, you can select the icon ( ) from the Windows messaging area.
Locate your interfaces and instruments in the Keysight Connection Expert Explorer Pane. The following graphic shows the Connection Expert screen.
All necessary drivers are pre-installed at the factory. These drivers include the mouse and keyboard drivers, video driver, GPIB driver, PXI trigger driver, etc.
Keysight M9037A PXIe Embedded Controller Startup Guide 18
Page 22

Step 5. Verify Operation

There are no actual verification procedures for the M9037A Embedded Controller. If it boots properly and the front panel status LEDs do not indicate an error (see “Front panel LED indicators” on page 8), then the controller is working normally.
Note that you can use Keysight’s Soft Front Panel (SFP) software to monitor and control the triggering and the M9018A chassis function. To start the SFP programs, Click the Windows Start button > All Programs > Keysight. Then select either the M9018A SFP or the Embedded Controller SFP. See the following screen capture.
Step 5. Verify Operation
19 Keysight M9037A PXIe Embedded Controller Startup Guide
Page 23

Step 6: Install User Application Modules in the PXIe Chassis

Step 6: Install User Application Modules in the PXIe Chassis
The PXIe chassis accepts modules conforming to the PXI standard, which can be installed in available slots in the chassis. These may include:
- PXI instrument or switch modules
- PXIe filler panel modules (PXIe chassis are shipped with filler panel modules in
all but Slot 1; you may need to remove filler panels from covered slots.)
Turn off the chassis prior to installing modules but do not unplug the chassis from the AC power source; the AC power cord grounds the chassis and protects it from electrical damage when modules are installed or removed.
- Static Electricity—The components and connectors on modules are sensitive to static electricity. To minimize electrostatic damage, take the necessary anti-static precautions. Both chassis provide a grounding terminal, to which you can connect a wrist strap.
- Empty Slots—Except for performing initial chassis verification or troubleshooting, do not operate the chassis with empty slots. Always insert a filler panel or instrument module into empty slots. This is especially important for the slots on either side of an instrument module. This allows proper air flow and cooling, and provides EMI shielding for the chassis and installed components. Leaving slots empty can increase fan speed, raise ambient noise, overheat components, and shut down modules.
- Hot Swap—PXIe does not explicitly support hot swap for instrument modules. Keysight recommends fully powering down the chassis before installing or removing modules

Install application module drivers (if necessary)

Installed application modules will typically require device drivers and control software. You need not install them to verify basic chassis or embedded controller operation, but would logically install them on the controller at this time. For others, consult the module provider for software requirements and instructions.
Connect the embedded controller to the internet to locate and install the necessary drivers.
Keysight M9037A PXIe Embedded Controller Startup Guide 20
Page 24

Upgrading from the M9036A

If you already have a Keysight M9036A Embedded Controller and you are upgrading to an M9037A, be aware of the following:
- The GPIB cables are not compatible.
- The video output and cables are not compatible.
- The IVI and LabVIEW API drivers and the Soft Front Panel software are not the
same. You will need to update any programs/applications you have written and rebuild them. The IVI Driver syntax (for the Trigger driver) M9036A used
AgM9036Trigger... (for example, AgM9036TriggerRouteTrigggerBusToExternal) but the M9037A
uses AgPxiPxTrigger.... Other than the prefix, the commands are
identical.
- The M9037A Trigger Output has a mild pull-down (via a 100 K resistor) to ~0 V. The M9036A Trigger output floated to ~3 V.
Upgrading from the M9036A
21 Keysight M9037A PXIe Embedded Controller Startup Guide
Page 25

Controller Operating System

Controller Operating System
Your M9037A comes with the Microsoft Windows Embedded Standard 7 (WES7) 32-bit or 64-bit Operating System preinstalled along with the latest version of Keysight's IO Libraries Suite (version 16.3 or later). This section provides some general system configuration and preventative maintenance procedures that you, the customer, are responsible for. In general, the M9037A operates as any other PC, including remote desktop access.

Windows security

If your system is connected to the internet, you should take the following steps to ensure the operating system is protected:
- Use an internet fire wall
- Get the latest Microsoft Windows updates
- Install and use up-to-date antivirus software.
To check the status of, or make changes to the security settings for your controller, open the Windows Security Center (Start > Control Panel > System & Security).
The default system setting for Windows Automatic Updates is turned off. If you want it turned on, you need to manually update your Windows OS by accessing Internet Explorer and from the Tools menu, select Windows Update.

User data backup

Downloading and installing Windows Updates can be network and CPU intensive (impacting system performance) and some Windows Updates automatically reboot the controller. Therefore, Windows Updates should be performed when the system is not in normal use.
There is no antivirus or spy ware software included with your controller. Antivirus application software is the customer's responsibility. Having antivirus software installed may have a slight impact on system performance if your system uses intensive network data transfer.
All user data should be regularly backed up to an external memory device. This can be done across a network or to a USB device. Your IT department may already have a backup strategy which is suitable for the system and data. Also, user data back up should be done just prior to sending the controller back to Keysight for service.
Keysight M9037A PXIe Embedded Controller Startup Guide 22
Page 26
The Windows operating system supplied with your M9037A is licensed for use on the hard drive mounted to the controller. If the hard drive is replaced, it may be your responsibility to purchase or relicense the operating system.

Chassis shutdown

As with any PC, Windows-based instruments should never be shutdown by either turning off the power via an external power source or by pulling the power plug out from the rear panel. This could corrupt the operating system. The approved way to shut down the controller is to execute the Windows shutdown process which shuts down the M9037A controller then turns off the M9018A chassis. If the M9018A chassis rear panel INHIBIT switch is set to DEF then momentarily pressing the front panel button shuts down the M9037A safely.
Controller Operating System
23 Keysight M9037A PXIe Embedded Controller Startup Guide
Page 27

M9018A PCIe Link Configuration

M9018A PCIe Link Configuration
PCIe link configuration refers to how the PXIe chassis (such as the M9018A) PCIe Switch Fabric is configured to connect PCI Express signals between slot 1, the system controller slot, and the other chassis slots. For a review of the supported PCIe link configurations, please refer to the M9018A User Guide (available from the Windows Start button, select All Programs > Keysight > M9018A).
Keysight’s M9037A can operate with all of the PCIe fabric configurations found on the M9018A chassis. Although the default M9018A PCIe chassis fabric is “2-Link Configuration: 1x8” (this configuration, referred to as 1x8, provides one x8 PCIe link from the system controller slot to the PCIe Switch Fabric) you should reconfigure it to either 2x8 or 4x4 fabric.
The other supported PCIe link configurations are:
- 2-Link Configuration: 2x8 — Referred to as 2x8, this configuration provides two x8 links from the system controller slot to the PCIe Switch Fabric. Link 1 can be routed by the PCIe Switch Fabric to slots 2-9, while Link 2 can be routed to slots 10-18. This fabric provides a pair of x8 links for high data IO performance. This is the recommended configuration for most applications.
- 4-Link Configuration: 4x4 — Referred to as 4x4, this configuration provides four x4 links from the system controller slot to the PCIe Switch Fabric. Link 1 can be routed by the PCIe Switch Fabric to slots 10-14, Link 2 can be routed to slots 15-18, Link 3 can be routed to slots 2-5, and Link 4 can be routed to slots 6-9. This fabric is more compatible with other non-Keysight system modules.
If your system design requires another PCIe link configuration, such as 2x8, use the chassis Configurator utility to change the PCIe Switch Fabric.
The Configurator utility program is available from the Windows Start button; select All Programs > Keysight > M9018A. Instructions for using the Configurator program are provided in the M9018A Chassis User Guide.
For more detailed information, refer to the M9037A User Guide and the M9018A 18-Slot PXIe Chassis User Guide.
Keysight M9037A PXIe Embedded Controller Startup Guide 24
Page 28

Using LabVIEW

The Keysight LabVIEW G driver version 1.0.x or later is required for LabVIEW programmatic control of the M9037A trigger subsystem.
National Instrument's LabVIEW is not preinstalled on the M9037 controller, only the trigger driver is preinstalled. Consequently, the LabVIEW trigger driver and help files exist only in either the:
(8.x represents LabVIEW version 8.5) and 20xx represents LabVIEW 2009, 2010, etc.).
Open the appropriate folder (8.x or 20xx) for the version of LabVIEW you installed on the M9037A. Copy the folder named Keysight M9037 (this contains three subfolders and other files) and paste it in the directory:
Using LabVIEW
Program Files\Keysight\M9037\LabVIEW Driver\8.x or \20xx folder or the Program Files (x86)\Keysight\M9037\LabVIEW Driver\8.x or \20xx folder.
Program Files\National Instruments\LabVIEW <your version>\instr.lib or Program Files (x86)\National Instruments\LabVIEW <your version>\instr.lib
You also need to copy the associated LabVIEW help file, AgPxiPc_LabVIEW_Help.chm from the
Program Files\Keysight\M9037\LabVIEW Driver Help folder or the Program Files (x86)\Keysight\M9037\LabVIEW Driver Help folder
to the directory:
Program Files\National Instruments\LabVIEW <your version> \help or Program Files (x86)\National Instruments\LabVIEW <your version> \help
25 Keysight M9037A PXIe Embedded Controller Startup Guide
Page 29

M9037A Accessories

M9037A Accessories
Accessory
Description
Number
Y1206A Keyboard and optical mouse
Y1260A GPIB Cable
*
Y1262A DisplayPort cable
Y1264A Spare SSD with Carrier, WES7, 32-bit preinstalled
Y1265A Spare SSD with Carrier, WES7, 64-bit preinstalled
Y1212A Slot Blocker Kit (5 single slot blockers)
Y1213A EMI Filler Panel Kit (5 single slot panels)
Y1214A Air Inlet Kit (one 3-slot, two 1-slot)
* This is not the same GPIB cable used on the Keysight M9036A PXIe Controller, they are not
compatible.
† Spare SSDs will not work with M9036A Embedded Controller
Keysight M9037A PXIe Embedded Controller Startup Guide 26
Page 30

Environmental Operating Conditions

The Keysight M9037A PXIe Embedded Controller is designed to operate in a temperature range of 0 maximum humidity is 95% at +40 (10,000 ft). The module should be operated in an indoor environment where temperature and humidity are controlled. Condensation can pose a potential shock hazard.
Condensation can occur when the module is moved from a cold to a warm environment, or if the temperature and/or humidity of the environment change quickly.
Samples of this product have been type tested in accordance with the Keysight Environmental Test Manual and verified to be robust against the environmental stresses of storage, transportation and end-use. Those stresses include but are not limited to temperature, humidity, shock, vibration, altitude and power line conditions. For complete specifications, check the Keysight web site at:
www.keysight.com/find/M9037A. Test methods are aligned with IEC 60068-2
and levels are similar to MIL-PRF-28800F Class 3.
°C to +55 °C with non-condensing humidity. The
Environmental Operating Conditions
°C. The maximum operating altitude is 3048 m
27 Keysight M9037A PXIe Embedded Controller Startup Guide
Page 31
Keysight M9037A PXIe Embedded Controller Startup Guide 28
Page 32
This information is subject to change without notice © Keysight Technologies, Inc. 2014 Edition 3 September 2014
*M9037-90001*
M9037-90001
www.keysight.com
Loading...