Keysight Technologies Infiniium 9000 Series, MSO9064A, DSO9064A, MSO9254A, MSO9104A User Manual

...
Keysight Infiniium 9000 Series Oscilloscopes
Distributed by:
dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ info@datatec.de ▪ www.datatec.de
User’s Guide
Notices
CAUTION
WARNING
© Keysight Technologies 2009, 2012, 2016, 2017
No part of this manual may be reproduced in any form or by any means (including elec­tronic storage and retrieval or translation into a foreign language) without prior agree­ment and written consent from Keysight Technologies as governed by United States and international copyright laws.
Manual Part Number
54904-97020
Edition
Fifth Edition, January 2017 Available in electronic format only
Published by:
Keysight Technologies 1900 Garden of the Gods Rd. Colorado Springs, CO 80907 USA
Warranty
The material contained in this docu­ment is provided “as is,” and is subject to being changed, without notice, in future editions. Further, to the maxi­mum extent permitted by applicable law, Keysight disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a par­ticular purpose. Keysight shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or perfor­mance of this document or of any infor­mation contained herein. Should Keysight and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the war­ranty terms in the separate agreement will control.
Technology Licenses
The hardware and/or software described in this document are furnished under a license and may be used or copied only in accor­dance with the terms of such license.
U.S. Government Rights
The Software is “commercial computer software,” as defined by Federal Acquisition Regulation (“FAR”) 2.101. Pursuant to FAR
12.212 and 27.405-3 and Department of Defense FAR Supplement (“DFARS”)
227.7202, the U.S. government acquires commercial computer software under the same terms by which the software is customarily provided to the public. Accordingly, Keysight provides the Software to U.S. government customers under its standard commercial license, which is embodied in its End User License Agreement (EULA), a copy of which can be found at
www.keysight.com/find/sweula. The
license set forth in the EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight: (1) Furnish technical information related to commercial computer software or commercial computer software documentation that is not customarily provided to the public; or (2) Relinquish to, or otherwise provide, the government rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, perform, display, or disclose commercial computer software or commercial computer software documentation. No additional government requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial computer software pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR
12.211 and 27.404.2 and DFARS 227.7102, the U.S. government acquires no greater
than Limited Rights as defined in FAR 27.401 or DFAR 227.7103-5 (c), as applicable in any technical data.
Safety Notices
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAU- TION notice until the indicated con­ditions are fully understood and met.
A WARNING notice denotes a haz­ard. It calls attention to an operat­ing procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.
For more safety information, refer to the For Your Safety booklet included with your
Infiniium oscilloscope.
Infiniium 9000 Series Oscilloscopes—At a Glance
Table 1 9000 Series oscilloscope models
Model Analog
bandwidth
DSO/MSO9064A 600 MHz 40 Mpts/20 Mpts
DSO/MSO9104A 1 GHz 40 Mpts/20 Mpts
DSO/MSO9254A 2.5 GHz 40 Mpts/20 Mpts
DSO/MSO9404A 4 GHz 40 Mpts/20 Mpts
DSO9024H 250 MHz 100 Mpts/50 Mpts
DSO9054H 500 MHz 100 Mpts/50 Mpts
DSO9104H 1 GHz 100 Mpts/50 Mpts
DSO9204H 2 GHz 100 Mpts/50 Mpts
DSO9024H, DSO9054H, DSO9104H, and DSO9204H models have up to 12 bits of high resolution.
Standard memory depth (2/4-channel mode)
Keysight Infiniium 9000 Series Oscilloscopes User’s Guide 3
Ease of use with high performance
The Keysight Technologies Infiniium oscilloscopes combine unprecedented ease-of-use with high-performance digitizing oscilloscope functionality to simplify your design and analysis measurement tasks.
Traditional oscilloscope front-panel interface provides direct access to the controls needed for most troubleshooting tasks.
Graphical user interface with menus, windows, dialog boxes, and toolbars provides easy access to dozens of configuration and analysis tools, ensuring you can set up and make the most complex measurements.
Models with bandwidths from 250 MHz to 4 GHz.
Display shows waveforms and graphical user interface
Graphical interface allows direct interaction with waveforms, including drag-and-drop positioning and instant waveform zoom.
Touchscreen display allows oscilloscope operation without an external pointing device.
•Waveforms displayed in color, making correlations easy.
Current configuration parameters displayed near the waveform display and are color-coded to make identification easy.
Graphical interface menus and toolbars simplify complex measurement setups.
Horizontal controls set sweep speed and position
Main sweep speeds from 5 ps/div to 20 s/div.
Intensified waveforms on main sweep window make it easy to see what will appear in the zoom window.
Acquisition and general controls start and stop the scope and do basic setup
Run and stop controls for continuous or single acquisitions.
•Clear display before one or more acquisitions.
Default setup and Autoscale set initial configuration.
Hard disk drive and USB 2.0 port for saving and restoring setups and measurement results
•Store measurement displays for inclusion in reports and test setup guides.
Store oscilloscope setups to repeat tests another time.
Hard disk stores oscilloscope operating system.
Trigger setup controls set mode and basic parameters
Select Edge, Glitch, or Advanced Modes.
Choose input source and slope.
4 Keysight Infiniium 9000 Series Oscilloscopes User’s Guide
Use graphical user interface to simplify configuration of pattern, state, delay, and violation trigger modes.
Vertical controls set attenuation and position
Input attenuation adjustable from 1 mV/div to 1 V/div.
Color-coded knobs make it easy to find the controls that affect each waveform.
Marker and quick measurements help measure waveform parameters
Use waveform markers 1 and 2 to check voltage or Δ-time at any point on the displayed waveform.
For more information about Infiniium oscilloscopes, see
www.keysight.com/find/scope.
Keysight Infiniium 9000 Series Oscilloscopes User’s Guide 5
In This Guide
This guide provides the information you need to begin using the Infiniium 9000 Series oscilloscope.
Chapter 1, “Setting Up the Oscilloscope,” starting on page 9 includes power and
air flow requirements, plus other setup information.
Chapter 2, “Using the Oscilloscope,” starting on page 27 gives an overview of the
front and side panel inputs and outputs, front-panel controls, and user interface, and tells you how to perform basic operations with the oscilloscope.
Chapter 3, “Online Help and Other Information,” starting on page 47 describes the
Infiniium oscilloscope application’s online help contents and online demos. The online help describes how to use the Infiniium oscilloscope application in detail.
For More Information
For detailed information on how the oscilloscope makes measurements and how to use the oscilloscope, see the Infiniium oscilloscope application’s online help.
For information on controlling the oscilloscope from a remote computer, see the Keysight Infiniium Oscilloscopes Programmer’s Guide found in the Infiniium oscilloscope application’s online help.
For information on testing and servicing the oscilloscope, see the Service Guide found in the Infiniium oscilloscope application’s online help.
6 Keysight Infiniium 9000 Series Oscilloscopes User’s Guide
Contents
Infiniium 9000 Series Oscilloscopes—At a Glance / 3
In This Guide / 6
1 Setting Up the Oscilloscope
Safety / 10
Symbols / 11
Inspecting Package Contents / 12
Environmental Characteristics / 13
Ventilation / 14
Connecting Accessories and Cables / 16
Connecting Power / 18
Connecting Oscilloscope Probes / 20
Tilting the Oscilloscope for Easier Viewing / 21
Turning On the Oscilloscope / 22
Verifying Basic Oscilloscope Operation / 23
Installing Application Programs on Infiniium / 24
Changing Windows Operating System Settings / 25
Turning Off the Oscilloscope / 26
Cleaning the Oscilloscope / 26
2 Using the Oscilloscope
Front Panel Controls (Keys and Knobs) Overview / 28
User Interface Overview / 29
Using the Setup and Display Controls / 32
Starting and Stopping Waveform Acquisitions / 33
Adjusting the Horizontal Time Scale and Trigger Position / 34
Adjusting the Vertical Settings / 36
Setting Up Triggers / 38
Keysight Infiniium 9000 Series Oscilloscopes User’s Guide 7
Using Markers and Making a Measurement / 40
Saving and Printing Data / 44
Forcing a Default Setup / 45
3 Online Help and Other Information
Accessing the Online Help / 47
Navigating the Online Help / 49
Using the Demo Wizard / 50
8 Keysight Infiniium 9000 Series Oscilloscopes User’s Guide
Keysight Infiniium 9000 Series Oscilloscopes User’s Guide
1 Setting Up the Oscilloscope
Safety 10 Inspecting Package Contents 12 Environmental Characteristics 13 Ventilation 14 Connecting Accessories and Cables 16 Connecting Power 18 Connecting Oscilloscope Probes 20 Tilting the Oscilloscope for Easier Viewing 21 Turning On the Oscilloscope 22 Verifying Basic Oscilloscope Operation 23 Installing Application Programs on Infiniium 24 Changing Windows Operating System Settings 25 Turning Off the Oscilloscope 26 Cleaning the Oscilloscope 26
This chapter shows how to set up your Infiniium oscilloscope, connect power and accessories, and verify general operation.
9
1 Setting Up the Oscilloscope
WARNING
WARNING
WARNING
Safety
This product has been designed and tested in accordance with accepted industry standards, and has been supplied in a safe condition. The documentation contains information and warnings that must be followed by the user to ensure safe operation and to maintain the product in a safe condition.
Safety Compliance
This product complies with the current editions of the following standards:
CAN/CSA-C22.2 No. 61010-1-12
UL Std. No. 61010-1 (3
Acoustic Statement
This is to declare that this instrument is in conformance with the German Regulation on Noise Declaration for Machines (Laermangabe nach der Maschinenlaermrerordnung -3.GSGV Deutschland).
rd
edition)
LpA < 70 dB
Operator position
Normal position per ISO 7779
General Safety Notices
This is a Safety Protection Class I Product (provided with a protective earthing ground incorporated in the power cord). The mains plug shall only be inserted in a socket outlet provided with a protective earth contact. Any interruption of the protective conductor inside or outside of the product is likely to make the product dangerous. Intentional interruption is prohibited.
If this product is not used as specified, the protection provided by the equipment could be impaired. This product must be used in a normal condition (in which all means for protection are intact) only.
No operator-serviceable parts inside. Refer servicing to qualified personnel. To prevent electrical shock, do not remove covers.
10 Keysight Infiniium 9000 Series Oscilloscopes User’s Guide
Symbols
Setting Up the Oscilloscope 1
These symbols are used on the Infiniium oscilloscope.
Symbol Description
The C-Tick mark is a registered trademark of the Australian Spectrum Management Agency.
The CE mark is a registered trademark of the European Community.
ICES / NMB-001 Cet appareil ISM est conforme a la norme NMB du Canada. This is a marking to indicate product compliance with the Industry Canadian Interference-Causing Equipment Standard (ICES-001). This is also a symbol of an Industrial Scientific and Medical Group 1 Class A product (CISPR 11, Clause 4).
This symbol indicates separate collection for electrical and electronic equipment mandated under EU law as of August 13, 2005. All electric and electronic equipment are required to be separated from normal waste for disposal (Reference WEEE Directive 2002/96/EC).
Indicates the time period during which no hazardous or toxic substance elements are expected to leak or deteriorate during normal use. Forty years is the expected useful life of the product.
The symbol on all primary and secondary packaging indicates compliance to China standard GB 18455-2001.
To return unwanted products, contact your local Keysight office.
The CSA mark is a registered trademark of the CSA International.
Keysight Infiniium 9000 Series Oscilloscopes User’s Guide 11
1 Setting Up the Oscilloscope
Inspecting Package Contents
Inspect the shipping container for damage.
Keep the shipping container or cushioning material until you have inspected
the contents of the shipment for completeness and have checked the oscilloscope mechanically and electrically.
If the shipping container is damaged, or the cushioning materials show signs
of stress, notify the carrier and your Keysight Technologies Sales Office. Keep the shipping materials for the carrier’s inspection. The Keysight Technologies Sales Office will arrange for repair or replacement at Keysight’s option without waiting for claim settlement.
Inspect the oscilloscope.
If there is mechanical damage or a defect, or if the oscilloscope does not operate properly or does not pass performance tests, notify your Keysight Technologies Sales Office.
Verify that you received the following items in the Infiniium oscilloscope
packaging.
Infiniium oscilloscope
Localized power cord
Keyboard
Mouse
Touch screen stylus
Accessory pouch (mounts on rear of oscilloscope)
Front panel cover
N2873A 10:1 divider passive probe per scope channel
Channel flying lead set logic probe, MSO cable, and calibration fixture (MSO
models only)
If anything is missing, contact your nearest Keysight Technologies Sales Office.
Verify that you received the options and accessories you ordered and that none
were damaged.
For a complete list of options and accessories available for the 9000 Series oscilloscopes, see the Infiniium 9000 Series Oscilloscopes Data Sheets.
12 Keysight Infiniium 9000 Series Oscilloscopes User’s Guide
Environmental Characteristics
Environment Indoor use only
Ambient temperature Operating: +5 °C to +40 °C
Non-operating: –40 °C to +65 °C
Humidity Operating: up to 95% relative humidity (non-condensing) at +40 °C
Non-operating: up to 90% relative humidity at +65 °C
Altitude Operating: up to 4,000 meters (13,123 feet)
Non-operating: up to 15,300 meters (50,000 feet)
Weight 26 lbs (11.8 kg)
Dimensions 16.8 in (43 cm) wide, 12.9 in (33 cm) tall, and 9 in (23 cm) deep
Safety UL61010-1 3
CAN/CSA-22.2 No. 61010-1-12
Installation category II
rd
edition
Setting Up the Oscilloscope 1
Voltage fluctuations The mains supply voltage fluctuations are not to exceed ±10% of the nominal
supply voltage.
Pollution degree The Infiniium 9000 Series oscilloscopes may be operated in environments of
Pollution Degree 2.
Pollution degree definitions
Pollution Degree 1: No pollution or only dry, non-conductive pollution occurs. The pollution has no influence. Example: A clean room or climate-controlled office environment. Pollution Degree 2. Normally only dry non-conductive pollution occurs. Occasionally a temporary conductivity caused by condensation may occur. Example: General indoor environment. Pollution Degree 3: Conductive pollution occurs, or dry, non-conductive pollution occurs which becomes conductive due to condensation which is expected. Example: Sheltered outdoor environment.
Keysight Infiniium 9000 Series Oscilloscopes User’s Guide 13
1 Setting Up the Oscilloscope
Minimum 0 mm
Minimum 0 mm
Front panel of oscilloscope
Minimum 25.4 mm
Minimum 25.4 mm
Minimum 75 mm
Top View
Rear Panel
Minimum bottom clearance: No intrusion into the space under the oscilloscope as defined by the feet. Feet must rest on hard surface.
CAUTION
Ventilation
1 Position the oscilloscope where it will have sufficient clearance for airflow
around the top, back, and sides.
Figure 1 Positioning the 9000 Series oscilloscope with sufficient clearance
VENTILATION REQUIREMENTS: When installing the instrument(s) into a cabinet, consider the convection flow into and out of the cabinet. Also consider the individual instruments, to avoid having the heated discharge of one instrument become the cooling intake air for another instrument.
14 Keysight Infiniium 9000 Series Oscilloscopes User’s Guide
Location
Setting Up the Oscilloscope 1
Install the oscilloscope so that the detachable power cord is readily identifiable and is easily reached by the operator.
The detachable power cord is the oscilloscope disconnecting device. It disconnects the mains circuits from the mains supply before other parts of the oscilloscope. (The front panel switch is only a standby switch and is not a LINE switch.)
Alternatively, an externally installed switch or circuit breaker (which is readily identifiable and is easily reached by the operator) may be used as a disconnecting device.
Keysight Infiniium 9000 Series Oscilloscopes User’s Guide 15
1 Setting Up the Oscilloscope
NOTE
Connecting Accessories and Cables
A mouse and keyboard can be plugged into either a USB port or a PS2 port. There are several USB connectors on the front panel or the side panel that can be used. When using the PS2 port, the keyboard must be plugged in prior to turning on power to the oscilloscope.
Connect your LAN cable to the RJ-45 connector on the side panel of the oscilloscope.
After you have connected to the LAN card, you must set up the network. Exit the oscilloscope application before you start setting up your network.
If you do not know how to set up a network in the Windows 7 operating system, see your network administrator or use the Windows 7 operating system’s online help.
Side panel USB connectors can be used for any USB devices. There are also three USB connectors in the lower right corner of the front panel.
If you have a parallel printer, you will need a parallel printer cable. Connect the cable to the parallel port on the side panel of the oscilloscope.
If you have a serial printer, you will need a 9-pin to 25-pin serial printer cable. Some printers may require other cable configurations, but the oscilloscope has a 9-pin serial connector. Connect the cable into the RS-232 port.